Search NASA⌕ Search

SEARCH · Search NASA

Results for “Composite Infrared Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Propyne: Determination of Physical Properties and Unit Cell Parameters under Titan-Relevant Conditions

With its large size, dense atmosphere, methane-based hydrological-like cycle, and diverse surface features, the Saturnian moon Titan is one of the most unique of the outer Solar System satellites. Study of the photochemically produced molecules in Titan’s atmosphere is critical in order to understand the mechanics of the atmosphere and, by extension, the interactions between atmosphere, surface, and subsurface water ocean. One example is propyne vapor, a photochemically produced species in Titan’s upper atmosphere expected to condense in Titan’s stratosphere at lower altitudes. Propyne may also be a trace species in Titan’s stratospheric co-condensed ice clouds detected by the Cassini Composite InfraRed Spectrometer. Bulk structural characterization of propyne ice is currently incomplete and is lacking in published laboratory Raman spectra and X-ray diffraction data. Here, we present a laboratory characterization of propyne ice, including the first published X-ray diffraction and Raman spectroscopy results for propyne ice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Jupiter in the Ultraviolet: Acetylene and Ethane Abundances in the Stratosphere of Jupiter from Cassini Observations between 0.15 and 0.19 μm

At wavelengths between 0.15 and 0.19 μm, the far-ultraviolet spectrum of Jupiter is dominated by the scattered solar spectrum, attenuated by molecular absorptions primarily by acetylene and ethane, and to a lesser extent ammonia and phosphine. We describe the development of our radiative transfer code that enables the retrieval of abundances of these molecular species from ultraviolet reflectance spectra. As a proof-of-concept we present an analysis of Cassini Ultraviolet Imaging Spectrograph (UVIS) observations of the disk of Jupiter during the 2000/2001 flyby. The ultraviolet-retrieved acetylene abundances in the upper stratosphere are lower than those predicted by models based solely on infrared thermal emission from the mid-stratosphere observed by the Composite Infrared Spectrometer (CIRS), requiring an adjustment to the vertical profiles above 1 mbar. We produce a vertical acetylene abundance profile that is compatible with both CIRS and UVIS, with reduced abundances at pressures <1 mbar: the 0.1 mbar abundances are 1.21 ± 0.07 ppm for acetylene and 20.8 ± 5.1 ppm for ethane. Finally, we perform a sensitivity study for the JUICE ultraviolet spectrograph, which has extended wavelength coverage out to 0.21 μm, enabling the retrieval of ammonia and phosphine abundances, in addition to acetylene and ethane.

79 ASTRONOMY AND ASTROPHYSICS↗

C{sub 2}N{sub 2} Vertical Profile in Titan’s Stratosphere

In this paper, we present the first measurements of the vertical distribution of cyanogen (C{sub 2}N{sub 2}) in Titan’s lower atmosphere at different latitudes and seasons, using Cassini’s Composite Infrared Spectrometer far-infrared data. We also study the vertical distribution of three other minor species detected in our data: methylacetylene (C{sub 3}H{sub 4}), diacetylene (C{sub 4}H{sub 2}), and H{sub 2}O, in order to compare them to C{sub 2}N{sub 2}, but also to get an overview of their seasonal and meridional variations in Titan’s lower stratosphere from 85 km to 225 km. We measured an average volume mixing ratio of C{sub 2}N{sub 2} of 6.2±0.8×10{sup −11} at 125 km at the equator, but poles exhibit a strong enrichment in C{sub 2}N{sub 2} (up to a factor 100 compared to the equator), greater than what was measured for C{sub 3}H{sub 4} or C{sub 4}H{sub 2}. Measuring C{sub 2}N{sub 2} profiles provides constraints on the processes controlling its distribution, such as bombardment by Galactic Cosmic Rays which seem to have a smaller influence on C{sub 2}N{sub 2} than predicted by photochemical models.

79 ASTRONOMY AND ASTROPHYSICS↗

A Performance Comparison of Low-Cost Near-Infrared (NIR) Spectrometers to a Conventional Laboratory Spectrometer for Rapid Biomass Compositional Analysis

The performance of a conventional laboratory near-infrared (NIR) spectrometer and two NIR spectrometer prototypes (a Texas Instruments NIRSCAN Nano evaluation model (EVM) and an InnoSpectra NIR-M-R2 spectrometer) are compared by collecting reflectance spectra of 270 well-characterized herbaceous biomass samples, building calibration models using the partial least squares (PLS-2) algorithm to predict five constituents of the samples from the reflectance spectra, and comparing the resulting model statistics. The prediction models developed using spectra from the Foss XDS spectrometer were slightly better than the prediction models developed using spectra from either the TI NIRSCAN Nano EVM and the InnoSpectra NIR-M-R2 as measured by the root mean square error (RMSECV) and the correlation coefficient (R 2 _cv) for “leave-one-out” cross-validation (CV). The models built from the two prototype units were not statistically significantly different from each other (p = 0.05). The Foss spectrometer has a larger wavelength range (400–2500 nm) compared with the two prototypes (900–1700 nm). When the spectra from the Foss XDS spectrometer were truncated so their wavelength range matched the wavelength range of the two prototype units, the resulting model was not statistically significantly different from the models from either prototype.

47 OTHER INSTRUMENTATION↗

Near-Infrared Spectroscopy can Predict Anatomical Abundance in Corn Stover

Feedstock heterogeneity is a key challenge impacting the deconstruction and conversion of herbaceous lignocellulosic biomass to biobased fuels, chemicals, and materials. Upstream processing to homogenize biomass feedstock streams into their anatomical components via air classification allows for a more tailored approach to subsequent mechanical and chemical processing. Here, we show that differing corn stover anatomical tissues respond differently to pretreatment and enzymatic hydrolysis and therefore, a one-size-fits-all approach to chemical processing biomass is inappropriate. To inform on-line downstream processing, a robust and high-throughput analytical technique is needed to quantitatively characterize the separated biomass. Predictive correlation of near-infrared spectra to biomass chemical composition is such a technique. Here, we demonstrate the capability of models developed using an “off-the-shelf,” industrially relevant spectrometer with limited spectral range to make strong predictions of both cell wall chemical composition and the relative abundance of anatomical components of the corn stover, the latter for the first time ever. Gaussian process regression (GPR) yields stronger correlations (average R 2 v = 88% for chemical composition and 95% for anatomical relative abundance) than the more commonly used partial least squares (PLS) regression (average R 2 v = 84% for chemical composition and 92% for anatomical relative abundance). In nearly all cases, both GPR and PLS outperform models generated using neural networks. These results highlight the potential for coupling NIRS with predictive models based on GPR due to the potential to yield more robust correlations.

09 BIOMASS FUELS↗

Integrating Very-High-Resolution UAS Data and Airborne Imaging Spectroscopy to Map the Fractional Composition of Arctic Plant Functional Types in Western Alaska: Supporting Data

Remote sensing maps of plant functional type (PFT) fractional cover (FCover), dominant PFT, and FCover uncertainty derived from NASA's Airborne Visible / Infrared Imaging Spectrometer - Next Generation (AVIRIS-NG). The AVIRIS-NG imaging spectroscopy data (380-2510 nm) was collected as a part of the collaboration between NASA's Arctic-Boreal Vulnerability Experiment (ABoVE; Miller et al., 2019) and DOE's Next Generation Ecosystem Experiment in the Arctic (NGEE-Arctic). This package includes maps of the NGEE-Arctic Council watershed on the Seward Peninsula, Alaska, created using AVIRIS-NG imagery collected on July 9th, 2019. The map data and metadata are provided as GeoTIFF (*.tif), ENVI image (*.dat), and text (*.txt, *hdr) formats. Additional map quicklooks are provided as *.pdf files and GIS *.kml files. These datasets are provided in support of Yang et al., (2023), "Integrating Very-High-Resolution UAS Data and Airborne Imaging Spectroscopy to Map the Fractional Composition of Arctic Plant Functional Types in Western Alaska".The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

New Insights into the Chemical Composition of Five Oort Cloud Comets after Re-analysis of Their Infrared Spectra

We present revised results for the main molecular species in five Oort Cloud comets observed with near-infrared echelle grating spectrometer (NIRSPEC) at the Keck Observatory between 1999 and 2012 (C/1999 S4 (LINEAR), C/2001 A2 (LINEAR), C/2007 W1 (Boattini), C/2012 F6 (Lemmon), and C/2012 S1 (ISON)). The re-evaluation of these data shows the improvement of results in some of the data sets, in particular for comets observed and analyzed before the advent of new and revised fluorescence models and terrestrial retrieval methods introduced since 2011. We observe significant improvements in the resulting rotational temperatures and the production rates for all species, and in mixing ratios of minor species (relative to water). The re-analysis also allowed us to quantify species not analyzed previously, mostly due to the lack of molecular models (e.g., ammonia and formaldehyde). We note, however, that the improvement of these revised values is less substantial for comets observed (and/or analyzed) since 2010.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty analysis of Raman spectra for measuring ortho-parahydrogen compositions

Determining ortho-parahydrogen compositions at cryogenic temperatures is an important quality control for liquid hydrogen custody exchange. High orthohydrogen compositions lead to an exothermic reaction resulting in increased boil off and increased venting losses of liquid hydrogen product by either the supplier or consumer. Traditional methods for measuring ortho-parahydrogen compositions such as hot-wire anemometry, nuclear magnetic resonance, and infrared spectroscopy are typically inconvenient at best. As the number of cryogenic hydrogen systems continue to increase, there is an increased need for flexible, standardized techniques for post processing composition measurements. A Raman spectrometer implemented in the Cryo-Catalysis Hydrogen Experimental Facility (CHEF) has demonstrated incredible flexibility for composition measurements of cryogenic hydrogen flows through a wide range of temperatures and pressures with the Raman probe in-situ at cryogenic temperatures. This article analyzes the uncertainty of Raman spectroscopy data of cryogenic hydrogen equilibrated at temperatures in IONEX catalyst. Spectra from hydrogen catalyzed to the equilibrium ortho-parahydrogen composition are processed and compared to expected statistical distributions for method verification.

08 HYDROGEN↗

Emissions Characterization for Ammonia Fuel Blends in an Enclosed Swirl-Stabilized Diffusion Burner

This study investigates ammonia flames using the enclosed Sydney swirl burner (ESSB), focusing on detailed global emissions measurements. Emissions were measured via Fourier-transform-infrared (FTIR) spectrometer, utilizing a heated, long-path absorption cell. Hot, wet measurements of pertinent species were collected, and concentrations were determined via lineshape fitting in conjunction with the HITRAN database. Results show that partially cracked ammonia compositions yield lower emissions compared to pure NH3/H2, and small amounts of NH3 addition to CH4-containing fuel blends exhibit high levels of NOx and CO, with measurable HCN and unburnt CH4. Equilibrium calculations suggest trade-offs between chemical timescale, heat loss, and mixing. Future work will explore emissions sampling procedures and expand analysis using chemical reactor network modelling.

ammonia combustion↗

Challenges in correlating oxygen stable isotope ratios of hydrates on uranium ore concentrates to process waters

Exchange of oxygen stable isotopes (δ 18 O values) between precipitation waters and uranium oxides is governed by thermodynamics or kinetics. It has been assumed that meteoric waters can be related to precipitation waters in uranium ore concentrates and their calcination and reduced uranium oxide products. With this assumption, the δ 18 O values of uranium materials could provide forensic signatures that identify the production history and geolocation of nuclear materials. To further exploit the potential of δ 18 O values in nuclear material analysis, this study examines the oxygen stable isotope exchange in two UOCs, magnesium diuranate (MDU) and sodium diuranate (SDU). MDU and SDU were synthesized from solutions of uranyl nitrate hexahydrate using precipitation waters with unique oxygen isotope compositions. The structures of the MDU and SDU were analyzed using powder X-ray diffraction (p-XRD) and thermal mass loss curves, while the δ 18 O values of waters generated during thermal decomposition were analyzed using a thermogravimetric analyzer coupled to an isotope ratio infrared spectrometer (TGA-IRIS). By p-XRD, the MDU was uniform and amorphous across all syntheses with residual crystalline material incorporated as a minor component. Combined with the TGA results, all of the MDU is likely amorphous MgU 2 O 7 ·3H 2 O with MgO impurities present throughout. In contrast, the SDU synthesis resulted in multiple phases with many samples exhibiting crystalline phases including a combination of Na(UO 2 ) 4 O 2 (OH) 5 ·5H 2 O and Na 2 (UO2) 6 O 4 (OH) 6 ·8H 2 O with a Na 2 U 2 O 7 minor phase. A small fraction of the SDU samples were amorphous with no crystalline XRD peaks observed. Mass loss curves of the SDU samples revealed that the amorphous samples contained inclusions of similar crystalline phases compared to the crystalline materials. The uniformity of the MDU samples enabled highly reproducible measurements of δ 18 O values of the water vapor yielded for two dehydration events at 170 °C and 500 °C. In contrast, the multiphase composition of the SDU samples resulted in poor reproducibility in δ 18 O values. In conclusion, neither system revealed any correlation between the δ 18 O values of precipitation water, and the waters released during dehydration of the UOCs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comprehensive analysis of common polymers using hyphenated TGA-FTIR-GC/MS and Raman spectroscopy towards a database for micro- and nanoplastics identification, characterization, and quantitation

Environmental contamination by micro- and nanoplastics (MNPs) is well documented with potential for their increased accumulation globally. Growing public concern over environmental, ecological, and human exposure to MNPs has led to exponential increase in publications, news articles, and reports. Significant knowledge gap exists in standardized analytical methods for the identification and quantification of MNPs from real world environmental samples. Here, in this study, we report comprehensive datasets utilizing thermogravimetric analyzer (TGA) coupled to a Fourier transformed infrared spectrometer (FTIR) and a gas chromatography/mass spectrometer (GC/MS) with corresponding Raman spectral data for the most common polymers documented to be present in the environment (35 plastics of 12 polymer types), to serve as a base line reference for the identification and quantitation of MNPs. Various parameters for TGA-FTIR-GC/MS data acquisition were optimized. Commercial consumer plastic product compositions were identified using this analytical database. Case studies to showcase the utility of the method for polymer mixtures analysis is included. This dataset would serve towards the development of a collaborative, global, comprehensive, and curated public database for the identification of various MNPs and mixtures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

Application of a Chemical Index to Aerosol Mass Spectrometry: Delta Plots and Functional Group Distributions

A better understanding of the chemical properties of organic aerosol (OA) particles will improve our ability to characterize their sources and predict their lifetime. The high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA in real time using thermal vaporization followed by electron ionization (EI). EI creates fragment ions that can be assigned to functional groups using delta analysis, a method of classifying mass spectra according to the presence of different chemically related ion series. In this study, we demonstrate the application of delta analysis to characterize molecular structures using a new visualization method. We also use delta analysis to quantify the functional group distribution with an average absolute error of ∼5–6% for individual standard molecules, comparable to the error observed for OA mixtures from biomass and coal combustion fit with Fourier transform infrared spectroscopy. Finally, we apply delta functional group analysis to AMS positive matrix factorization (PMF) factors across seven different field campaigns and find a similar composition across the more oxidized factors with about 55% acid and 26% alcohol groups. The analysis method described here can be applied to any HR-ToF-AMS data set to provide quantitative relative functional group distributions for OA mixtures.

aerosol↗

Single-Cell Metabolomics with Rapid Determination of Chemical Formulas from Isotopic Fine Structures

Metabolomic measurements can provide functional readouts of cellular states and phenotypes. Here, we present a protocol for single-cell metabolomics that permits direct untargeted detection of a broad number of metabolites under ambient conditions, without the need for sample processing, and with high confidence in the discovery and identification of the molecular formulas for detected metabolites. This protocol describes combining fiber-based laser ablation electrospray ionization (f-LAESI) with a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer (21T-FTICR-MS) to obtain high confidence molecular formula information about detected metabolites. The f-LAESI source utilizes mid-infrared laser ablation through a sharp optical fiber tip, affording direct ambient analysis of cells without the need for sample processing. Using the 21T-FTICR-MS as a mass analyzer enabled measurement of the isotopic fine structure (IFS) for numerous metabolites simultaneously from single cells, and the IFSs were in turn computationally processed to rapidly determine the corresponding elemental compositions. This metabolomics technique complements other single cell omics measurement methods, helping to resolve complex molecular interactions that take place within cells unattainable from single cell transcriptomic and proteomics methods.

mass spectrometry, FTICR, FTMS, ultrahigh mass res↗

Analysis of Hybrid Gas–Dust Outbursts Observed at 67P/Churyumov–Gerasimenko

Cometary outbursts offer a valuable window into the composition of comet nuclei with their forceful ejection of dust and volatiles in explosive events, revealing the interior components of the comet. Understanding how different types of outbursts influence the dust properties and volatile abundances, to better interpret what signatures can be attributed to primordial composition and what features are the result of processing, is an important task best undertaken with a multi-instrument approach. The European Space Agency Rosetta mission to 67P/Churyumov–Gerasimenko carried a suite of instruments capable of carrying out this task in the near-nucleus coma with unprecedented spatial and spectral resolution. In this work, we discuss two outbursts that occurred 2015 November 7 and were observed by three instruments on board: the Alice ultraviolet spectrograph, the Visual Infrared and Thermal Imaging Spectrometer, and the Optical, Spectroscopic, and Infrared Remote Imaging System. Together, the observations show that mixed gas and dust outbursts can have different spectral signatures representative of their initiating mechanisms, with the first outburst showing indicators of a cliff collapse origin and the second more representative of fresh volatiles being exposed via a deepening fracture. This analysis opens up the possibility of remote spectral classification of cometary outbursts with future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-dependent diffuse reflectance measurements of ceramic powders in the near- and mid-infrared spectra

Radiative properties are critical to quantify radiative energy fluxes between surfaces and in participating media. However, there is limited experimental data on temperature-dependent radiative properties of materials. Herein, this work focuses on experimentally measuring temperature-dependent diffuse reflectance in the near- and mid-infrared spectra (1–20 μm) for ceramic particles with applications as heat-transfer and thermal-storage media in concentrated solar power (CSP) plants. Specifically, a commercially available sintered bauxite proppant, ACCUCAST ID80, and its primary chemical constituents—alumina (Al 2 O 3 ) and silica (SiO 2 )—are measured in powder form using a Fourier transform infrared spectrometer (FTIR) coupled with a specialized diffuse reflectance accessory and a heated stage. Room-temperature diffuse reflectance measurements show increased absorption in tests with greater mass fractions of the ceramic samples. There is a strong correlation in the measured reflectance spectra of ACCUCAST with alumina and silica in the spectral range 2000–500 cm –1 (5–20 μm). Whereas, for shorter wavelengths (< 5 μm), the absorptance for ACCUCAST is greater than the absorptance for alumina and silica, indicating contributions from other chemical species present in the composite material. For the first time, temperature-dependent diffuse reflectance measurements are reported for ACCUCAST up to 1000 °C. These results are compared against those of alumina and silica through the calculation of a thermal emittance. All three materials exhibit a calculated emittance of ~0.9 at room temperature. However, this value decreases to ~0.6 for ACCUCAST and drops to less than 0.4 for alumina and silica at 1000 °C. Thermal cycling in air at 1000 °C resulted in a visible color change from dark grey to light orange for ACCUCAST and a subsequent larger increase in reflectance for wavelengths less than 5 μm as compared to ACCUCAST thermally cycled at 1000 °C in vacuum. Alumina and silica spectra proved to be largely unaffected by thermal cycling under atmospheric conditions. Overall, this study establishes a powerful technique for the characterization of radiative properties of particulate materials as a function of temperature and presents a detailed case study of ACCUCAST, a candidate for next-generation particle-based CSP.

14 SOLAR ENERGY↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗