Highly Loaded Composite Strut Test Results

Highly loaded composite struts from a proposed truss-based Altair lunar lander descent stage concept were selected for development under NASA's Advanced Composites Technology program. Predicted compressive member forces during launch and ascent of over -100,000 lbs were much greater than the tensile loads. Therefore, compressive failure modes, including structural stability, were primary design considerations. NASA's industry partner designed and built highly loaded struts that were delivered to NASA for testing. Their design, fabricated on a washout mandrel, had a uniform-diameter composite tube with composite tapered ends. Each tapered end contained a titanium end fitting with facing conical ramps that are overlaid and overwrapped with composite materials. The highly loaded struts were loaded in both tension and compression, with ultimate failure produced in compression. Results for the two struts tested are presented and discussed, along with measured deflections, strains and observed failure mechanisms.

Wu, K. C.↗

Highly Loaded Composite Strut Test Development

Highly loaded composite struts, representative of structural elements of a proposed truss-based lunar lander descent stage concept, were selected for design, development, fabrication and testing under NASA s Advanced Composites Technology program. The focus of this paper is the development of a capability for experimental evaluation of the structural performance of these struts. Strut lengths range from 60 to over 120 inches, and compressive launch and ascent loads can exceed -100,000 lbs, or approximately two times the corresponding tensile loads. Allowing all possible compressive structural responses, including elastic buckling, were primary considerations for designing the test hardware.

Wu, K. Chauncey↗

Real Time Detection of Damage During Quasi-Static Loading of a Single Stringer Panel Using Passive Thermography

Real time nondestructive evaluation is required for composites load testing. The early detection and measurement of damage progression is important to understand failure modes. A single stringer panel was subjected to quasi-static loading to induce deformation which can result in the formation of delamination damage between the stiffener flange and skin. Passive thermography was used to detect damage in real time as a function of the applied load. The loading was stopped when damage growth was detected. Of particular interest was the early detection of damage formation which can be challenging, as compared to cyclic fatigue loading. Passive thermography data were acquired and processed in real time and revealed damaged areas due to heating from fiber breakage and delamination formation. The processed thermal imagery was also compared to acoustic emission and ultrasound data.

Zalameda, Joseph N.↗

Bearing-bypass loading in composite joints - Testing and stress analysis

A combined experimental and analytical study of bearing and bypass loading on single-fastener specimens of a 16-ply, quasi-isotropic T300/5208 graphite/epoxy laminate with a centrally located hole is reported. The specimens were loaded in either tension or compression, and onset damage, ultimate strengths, and corresponding failure modes were determined. The tension data showed the expected linear interaction for combined bearing-bypass loading with damage developing in the net-section tension mode. However, the bearing-onset strengths showed an unexpected interaction of the bearing and compressive bypass loads in which the latter reduced the bearing-onset strength. A linear finite element analysis showed that bearing-bypass loading had a marked influence on the bolt-hole contact which in turn had a significant effect on local stresses.

Crews, John H., Jr.↗

Use of 3000 Bragg Grating Strain Sensors Distributed on Four Eight-meter Optical Fibers During Static Load Tests of a Composite Structure

This paper describes the use of a fiber optic system to measure strain at thousands of locations along optical fibers where weakly reflecting Bragg gratings have been photoetched. The optical fibers were applied to an advanced composite transport wing along with conventional foil strain gages. A comparison of the fiber optic and foil gage systems used for this test will be presented including: a brief description of both strain data systems; a discussion of the process used for installation of the optical fiber; comparative data from the composite wing test; the processes used for the location and display of the high density fiber optic data. Calibration data demonstrating the potential accuracy of the fiber optic system will also be presented. The opportunities for industrial and commercial applications will be discussed. The fiber optic technique is shown to be a valuable augmentation to foil strain gages providing insight to structural behavior previously requiring reliance on modeling.

Childers, Brooks A.↗

Acoustic emission testing of composite vessels under sustained loading

Acoustic emission (AE) tests have been conducted on small-diameter Kevlar 49/epoxy pressure vessels subjected to long-term sustained load-to-failure tests. Single-cycle burst tests were used as a basis for determining the test pressure in the sustained-loading tests. AE data from two vessel locations were compared. The data suggest that AE from vessel wall-mounted transducers is quite different for identical vessels subjected to the same pressure loading. AE from boss-mounted transducers yielded relatively consistent values. These values were not a function of time for vessel failure. The development of an AE test procedure for predicting the residual service life or integrity of composite vessels is discussed.

Lark, R. F.↗

Thermography Inspection for Detection and Tracking of Composite Cylinder Damage During Load Testing

Two thermography techniques, passive and active, are used to detect damage initiation and progression in a cyclically loaded composite cylinder. The passive thermography tracks damage progression in real time during cyclic loading. Active flash thermography, using a flash tube enclosed within the cylinder, images delaminations in a cylinder under different loads. A differential thermography processing technique eliminates normal material variations and improves sensitivity to and sizing of delaminations. The thermography results were compared to nonimmersion ultrasonic results.

Zalameda, J. N.↗

A test method to measure the response of composite materials under reversed cyclic loads

A test method to measure the response of composite materials under reversed cyclic loads is described. The method approximates the long-term response of a component by permitting the composite specimen to respond to the imposed loads and fail in an unconstrained mode rather than in a constrained mode. The method has been successfully used for the reversed cyclic loading of unnotched and notched graphite/epoxy and graphite/PEEK laminates of various stacking sequences. Included in the paper are monotonic tensile and compressive stiffness and strength data at several points in the fatigue lifetime, and damage development information obtained via X-ray radiography for quasi-isotropic T300/5208 and AS4/PEEK laminates with unloaded circular holes.

Bakis, Charles E.↗

Acoustic emission testing of composite vessels under sustained loading

Acoustic emissions (AE) generated from Kevlar 49/epoxy composite pressure vessels subjected to sustained load-to-failure tests were studied. Data from two different transducer locations on the vessels were compared. It was found that AE from vessel wall-mounted transducers showed a wide variance from those for identical vessels subjected to the same pressure loading. Emissions from boss-mounted transducers did, however, yield values that were relatively consistent. It appears that the signals from the boss-mounted transducers represent an integrated average of the emissions generated by fibers fracturing during the vessel tests. The AE from boss-mounted transducers were also independent of time for vessel failure. This suggests that a similar number of fiber fractures must occur prior to initiation of vessel failure. These studies indicate a potential for developing an AE test procedure for predicting the residual service life or integrity of composite vessels.

Lark, R. F.↗

Effect of load introduction in compression testing of composite laminates

Compression testing of composite materials is affected by the manner in which the compressive load is introduced. Two such effects are studied in this paper: (a) the constrained edge effect, in which transverse expansion of the edges is prevented while the axial load is introduced, and (b) nonuniform gripping, as manifested by inplane bending of the test specimen. The principle of minimum complementary energy is used to develop an analytical model that quantifies these two effects upon the measured elastic properties of laminated composites. Numerical results are presented for selected high-strength graphite/epoxy composites.

Reiss, R.↗

Thermal loading in the laser holography nondestructive testing of a composite structure

A laser holographic interferometry method that has variable sensitivity to surface deformation was applied to the investigation of composite test samples under thermal loading. A successful attempt was made to detect debonds in a fiberglass-epoxy-ceramic plate. Experimental results are presented along with the mathematical analysis of the physical model of the thermal loading and current conduction in the composite material.

Liu, H. K.↗

Testing and Analysis of Composite Skin/Stringer Debonding Under Multi-Axial Loading

Damage mechanisms in composite bonded skin/stringer constructions under uniaxial and biaxial (in-plane/out- of-plane) loading conditions were examined. Specimens consisted of a tapered composite flange bonded onto a composite skin. Tests were performed under monotonic loading conditions in tension, three-point bending, and combined tension/bending . For combined tension/bending testing, a unique servohydraulic load frame was used that was capable of applying both in-plane tension and out-of-plane bending loads simultaneously. Specimen edges were examined on the microscope to document the damage occurrence and to identify typical damage patterns. The observations showed that, for all three load cases, failure initiated in the flange, near the flange tip, causing the flange to almost fully debond from the skin. A two-dimensional plane-strain finite element model was developed to analyze the different test cases using a geometrically nonlinear solution. For all three loading conditions, principal stresses exceeded the transverse strength of the material in the flange area. Additionally, delaminations of various lengths were simulated in two locations where delaminations were observed. The analyses showed that unstable delamination propagation is likely to occur in one location at the loads corresponding to matrix ply crack initiation for all three load cases.

Krueger, Ronald↗

Fatigue-Testing Apparatus for Metal Matrix Composites

Thermal and mechanical load cycling simulated in realistic fatigue tests. Efficient joining of metal matrix composite components to supporting structures is major concern facing users of these materials. Lewis Research Center designed and developed two thermal/mechancical fatigue test facilities, one to test metal matrix composite specimens and another to test compostite/metal attachment bond joints. Thermal/mechanical fatigue facility designed for testing metal matrix composites permits specimen-temperature excursions with controlled heating and loading rates. Second facility designed to test composite/metal attachment bond joints and to permit heating to maximum temperature of 1,400oC (760oC) within 10 min and cooling to 300oF (150oC) within 3 min. Facility has unique capabilities not found in other laboratories.

Westfall, Leonard J.↗

Testing and Analysis of Composite Skin/Stringer Debonding Under Multi-Axial Loading

A consistent step-wise approach is presented to investigate the damage mechanism in composite bonded skin/stringer constructions under uniaxial and biaxial (in-plane/out-of-plane) loading conditions. The approach uses experiments to detect the failure mechanism, computational stress analysis to determine the location of first matrix cracking and computational fracture mechanics to investigate the potential for delamination growth. In a first step, tests were performed on specimens, which consisted of a tapered composite flange, representing a stringer or frame, bonded onto a composite skin. Tests were performed under monotonic loading conditions in tension, three-point bending, and combined tension/bending to evaluate the debonding mechanisms between the skin and the bonded stringer. For combined tension/bending testing, a unique servohydraulic load frame was used that was capable of applying both in-plane tension and out-of-plane bending loads simultaneously. Specimen edges were examined on the microscope to document the damage occurrence and to identify typical damage patterns. For all three load cases, observed failure initiated in the flange, near the flange tip, causing the flange to almost fully debond from skin. In a second step, a two dimensional plane-strain finite element model was developed to analyze the different test cases using a geometrically nonlinear solution. For all three loading conditions, computed principal stresses exceeded the transverse strength of the material in those areas of the flange where the matrix cracks had developed during the tests. In a third step, delaminations of various lengths were simulated in two locations where delaminations were observed during the tests. The analyses showed that at the loads corresponding to matrix ply crack initiation computed strain energy release rates exceeded the values obtained from a mixed mode failure criterion in one location, Hence. Unstable delamination propagation is likely to occur as observed in the experiments.

Krueger, Ronald↗

Testing and Analysis of Composite Skin/Stringer Debonding under Multi-Axial Loading

A consistent step-wise approach is presented to investigate the damage mechanism in composite bonded skin/stringer constructions under uniaxial and biaxial (in-plane/out-of-plane) loading conditions. The approach uses experiments to detect the failure mechanism, computational stress analysis to determine the location of first matrix cracking and computational fracture mechanics to investigate the potential for delamination growth. In a first step, tests were performed on specimens, which consisted of a tapered composite flange, representing a stringer or frame, bonded onto a composite skin. Tests were performed under monotonic loading conditions in tension, three-point bending, and combined tension/bending to evaluate the debonding mechanisms between the skin and the bonded stringer. For combined tension/bending testing, a unique servohydraulic load frame was used that was capable of applying both in-plane tension and out-of-plane bending loads simultaneously. Specimen edges were examined on the microscope to document the damage occurrence and to identify typical damage patterns. For all three load cases, observed failure initiated in the flange, near the flange tip, causing the flange to almost fully debond from the skin. In a second step, a two-dimensional plane-strain finite element model was developed to analyze the different test cases using a geometrically nonlinear solution. For all three loading conditions, computed principal stresses exceeded the transverse strength of the material in those areas of the flange where the matrix cracks had developed during the tests. In a third step, delaminations of various lengths were simulated in two locations where delaminations were observed during the tests. The analyses showed that at the loads corresponding to matrix ply crack initiation computed strain energy release rates exceeded the values obtained from a mixed mode failure criterion in one location. Hence, unstable delamination propagation is likely to occur as observed in the experiments.

Krueger, Ronald↗

Advanced composite aileron for L-1011 transport aircraft: Ground tests and flight evaluation

A composite aileron and a metal aileron were subjected to a series of comparative stiffness and vibration tests. These tests showed that the stiffness and vibration characteristics of the composite aileron are similar to the metal aileron. The first composite ground test article was statically tested to failure which occurred at 139 percent of design ultimate load. The second composite ground test article was tested to verify damage tolerance and fail-safe characteristics. Visible damage was inflicted to the aileron and the aileron was subjected to one lifetime of spectrum fatigue loading. After conducting limit load tests on the aileron, major damage was inflicted to the cover and the aileron was loaded to failure which occurred at 130 percent of design ultimate load. A shipset of composite ailerons were installed on Lockheed's L-1011 flight test aircraft and flown. The composite aileron was flutter-free throughout the flight envelope.

Griffin, C. F.↗