An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compound refractive lenses as prefocusing optics for X-ray FEL radiation

The performance of X-ray free-electron laser beamlines may be limited by the angular aperture. Compound refractive lenses (CRLs) can be employed to prefocus the X-ray beam, thereby increasing the beamline transmission. A prefocusing CRL was implemented in the X-ray transport of the Matter under Extreme Conditions Instrument at the Linac Coherent Light Source. A significant improvement in the beamline transmission was calculated over the 3–10 keV photon energy range. At 5 keV, the relative X-ray intensity was measured and a factor of four increase was seen in the beamline transmission. As a result, the X-ray focus was also determined by the ablation imprint method.

43 PARTICLE ACCELERATORS↗

NSLS-II X-Ray Diagnostics Development

NSLS-II x-ray diagnostics will provide continuous online data of electron beam dimensions, which will be used to derive electron beam emittance and energy spread. It will also provide information of electron beam tilt for coupling evaluation. X-ray diagnostics will be based on imaging of bending magnet and three-pole wiggler synchrotron radiation sources. Diagnostics from three-pole wiggler source will be used to derive particles energy spread. Beta and dispersion functions will have to be evaluated for emittance and particles energy spread calculations. Due to small vertical source sizes imaging need to be performed in x-ray energy range. X-ray optics with high numerical aperture, such as compound refractive lens, will be used to achieve required spatial resolution. Optical setups with different magnifications in horizontal and vertical directions fill be employed to deal with large aspect ratio of the source. X-ray diagnostics setup will include x-ray imaging optics, monochromatization, x-ray imaging and recording components.

43 PARTICLE ACCELERATORS↗

A Dynamic Amplitude-Correcting Gradient Estimation Technique to Align X-ray Focusing Optics

High-brightness X-rays, as produced at synchrotrons and X-ray free electron laser (XFEL) facilities, are used to characterize materials in a variety of scientific experiments. In most cases, effective use of the high-energy light requires precisely-aligned focusing optics; one example being a compound refractive lens (CRL). To align a CRL, the position and rotation must be optimized along four axes. In practice, this is a labor-intensive, time-consuming manual process that can monopolize scarce experimental time at the necessary X-ray facilities. Models of the expected Xray transmission function suggest that this task can be automated; however, the temporally-varying intensity at X-ray free electron laser facilities preclude the direct use of standard implementations of optimization solvers such as steepest descent algorithms. In this paper, we propose a novel technique to estimate the gradient of noisy functions with temporally-varying amplitudes. We construct this dynamicamplitude correction by systematically sampling a fixed central location within the standard finite difference stencil, accounting for the observed changes in time, and normalizing the difference quotients against those fluctuations. In addition to a rigorous error analysis of the sampling technique, we demonstrate its efficacy in stochastic descent optimization methods. Further, we demonstrate how this approach may be implemented to optimize X-ray focusing optics at synchrotrons or XFEL facilities

97 MATHEMATICS AND COMPUTING↗

Application of small-angle neutron scattering to the study of forces between magnetically chained monodisperse ferrofluid emulsion droplets

The optical magnetic chaining technique (MCT) developed by Leal-Calderon, Bibette and co-workers in the 1990 s allows precise measurements of force profiles between droplets in monodisperse ferrofluid emulsions. However, the method lacks an in-situ determination of droplet size and therefore requires the combination of separately acquired measurements of droplet chain periodicity versus an applied magnetic field from optical Bragg scattering and droplet diameter inferred from dynamic light scattering (DLS) to recover surface force-distance profiles between the colloidal particles. Compound refractive lens (CRL) focussed small-angle scattering (SANS) MCT should result in more consistent measurements of droplet size (form factor measurements in the absence of field) and droplet chaining period (from structure factor peaks when the magnetic field is applied); and, with access to shorter length scales, extend force measurements to closer approaches than possible by optical measurements. We report on CRL-SANS measurements of monodisperse ferrofluid emulsion droplets aligned in straight chains by an applied field perpendicular to the incident beam direction. Analysis of the scattering from the closely spaced droplets required algorithms that carefully treated resolution and its effect on mean scattering vector magnitudes in order to determine droplet size and chain periods to sufficient accuracy. At lower applied fields scattering patterns indicate structural correlations transverse to the magnetic field direction due to the formation of intermediate structures in early chain growth.

Colloid↗

Secondary concentrators for parabolic dish solar thermal power systems

A variety of different concepts are currently being studied with the objective to lower the cost of parabolic mirrors and to provide alternatives. One of the considered approaches involves the use of compound concentrators. A compound solar concentrator is a concentrator in which the sunlight is reflected or refracted more than once. It consists of a primary mirror or lens, whose aperture determines the amount of sunlight gathered, and a smaller secondary mirror or lens. Additional small optical elements may also be incorporated. The possibilities and problems regarding a use of compound concentrators in parabolic dish systems are discussed. Attention is given to concentrating secondary lenses, secondary imaging and concentrating mirrors, conical secondary mirrors, compound elliptic secondary concentrating mirrors, and hyperbolic trumpet secondary concentrating mirrors.

Jaffe, L. D.↗

Single-crystal diamond refractive lens for focusing X-rays in two dimensions

The fabrication and performance evaluation of single-crystal diamond refractive X-ray lenses of which the surfaces are paraboloids of revolution for focusing X-rays in two dimensions simultaneously are reported. The lenses were manufactured using a femtosecond laser micromachining process and tested using X-ray synchrotron radiation. Such lenses were stacked together to form a standard compound refractive lens (CRL). Owing to the superior physical properties of the material, diamond CRLs could become indispensable wavefront-preserving primary focusing optics for X-ray free-electron lasers and the next-generation synchrotron storage rings. They can be used for highly efficient refocusing of the extremely bright X-ray sources for secondary optical schemes with limited aperture such as nanofocusing Fresnel zone plates and multilayer Laue lenses.

Antipov, S.↗

Characterization of a one dimensional focusing compound refractive lens using the rotating shearing interferometer technique

A one dimensional (1D) compound refractive lens (CRL) has been characterized using the grating based rotating shearing interferometer technique. The method is based on the calculation of moire fringes orientation to sense wavefront information. The phase shift and the optical aberration introduced by the 1D CRL on an X-ray beam were retrieved from a single moire fringe image. The radius of curvature of the lens at the apex was derived. This physical radius of the CRL, which is also closely related to the focal length of the 1D CRL, was shown to vary with the incident angle of the incoming X-ray beam onto the CRL. The experimental measurement agreed very well with the theoretical expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the X-ray coherence properties of an undulator beamline at the Advanced Photon Source

In anticipation of the increased use of coherent X-ray methods and the need to upgrade beamlines to match improved source quality, here the coherence properties of the X-rays delivered by beamline 12ID-D at the Advanced Photon Source have been characterized. The measured X-ray divergence, beam size, brightness and coherent flux at energies up to 26 keV are compared with the calculated values from the undulator source, and the effects of beamline optics such as a mirror, monochromator and compound refractive lenses are evaluated. Diffraction patterns from slits as a function of slit width are analyzed using wave propagation theory to obtain the beam divergence and thus coherence length. Imaging of the source using a compound refractive lens was found to be the most accurate method for determining the vertical divergence. While the brightness and coherent flux obtained without a monochromator (`pink beam') agree well with those calculated for the source, those measured with the monochromator were a factor of three to six lower than the source, primarily because of vertical divergence introduced by the monochromator. The methods described herein should be widely applicable for measuring the X-ray coherence properties of synchrotron beamlines.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are thus a key element of many beamlines at X-ray facilities, used to either to focus a beam or image a sample. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam; aligning CRLs is thus typically treated as a time-consuming manual process. Many groups circumvent day-to-day realignment by using engineering controls (e.g. mounting optics) that sacrifice some of the beam’s focusing characteristics, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. Our approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder-Mead (SNM) simplex method. We demonstrate the efficacy of this method by numerical simulation and then extend this test to real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron X-ray beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

97 MATHEMATICS AND COMPUTING↗

Refractive Optics for Hard X-ray Transmission Microscopy

For hard x-ray transmission microscopy at photon energies higher than 15 keV we design refractive condenser and imaging elements to be used with synchrotron light sources as well as with x-ray tube sources. The condenser lenses are optimized for low x-ray attenuation--resulting in apertures greater than 1 mm--and homogeneous intensity distribution on the detector plane, whereas the imaging enables high-resolution (<100 nm) full-field imaging. To obtain high image quality at reasonable exposure times, custom-tailored matched pairs of condenser and imaging lenses are being developed. The imaging lenses (compound refractive lenses, CRLs) are made of SU-8 negative resist by deep x-ray lithography. SU-8 shows high radiation stability. The fabrication technique enables high-quality lens structures regarding surface roughness and arrangement precision with arbitrary 2D geometry. To provide point foci, crossed pairs of lenses are used. Condenser lenses have been made utilizing deep x-ray lithographic patterning of thick SU-8 layers, too, whereas in this case, the aperture is limited due to process restrictions. Thus, in terms of large apertures, condenser lenses made of structured and rolled polyimide film are more attractive. Both condenser types, x-ray mosaic lenses and rolled x-ray prism lenses (RXPLs), are considered to be implemented into a microscope setup. The x-ray optical elements mentioned above are characterized with synchrotron radiation and x-ray laboratory sources, respectively.

07 ISOTOPE AND RADIATION SOURCES↗

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Controllable Sonar Lenses and Prisms Based on ERFs

Sonar-beam-steering devices of the proposed type would contain no moving parts and would be considerably smaller and less power-hungry, relative to conventional multiple-beam sonar arrays. The proposed devices are under consideration for installation on future small autonomous underwater vehicles because the sizes and power demands of conventional multiple-beam arrays are excessive, and motors used in single-beam mechanically scanned systems are also not reliable. The proposed devices would include a variety of electrically controllable acoustic prisms, lenses, and prism/lens combinations both simple and compound. These devices would contain electrorheological fluids (ERFs) between electrodes. An ERF typically consists of dielectric particles floating in a dielectric fluid. When an electric field is applied to the fluid, the particles become grouped into fibrils aligned in rows, with a consequent increase in the viscosity of the fluid and a corresponding increase in the speed of sound in the fluid. The change in the speed of sound increases with an increase in the applied electric field. By thus varying the speed of sound, one varies the acoustic index of refraction, analogously to varying the index of refraction of an optical lens or prism. In the proposed acoustic devices, this effect would be exploited to control the angles of refraction of acoustic beams, thereby steering the beams and, in the case of lenses, controlling focal lengths.

Bar-Cohen, Yoseph↗

Etched Silicon Planar CRL Optics for the High-Energy X-ray Diffraction Beamlines 11-ID-B and 11-ID-C at the APS

We report the focusing of high-energy X-rays is most commonly achieved by commercially available compound refractive lenses (CRL), which are added together in larger structures. There is a need for high-energy X-ray beamlines to enable focusing in only one dimension down to a few micrometers to study layered materials and thin films. High-energy X-rays above 50 keV require often 100 lenses or more, therefore it is more efficient to etch the complete arrays of lenses into a monolithic substrate like a silicon wafer. Custom lens arrays were fabricated for the high-energy x-ray beamlines 11-ID-B, and 11-ID-C at the Argonne National Laboratory. The fabrication required tuning parameters of the Bosch process to optimize the etching of deep vertical sidewalls at a reasonable speed without overheating. The beamline 11-ID-B is equipped with lens arrays of 85-110 lenses for 59 keV and 190-250 lenses for 87 keV photon energy, focusing the beam vertically below 5.0 µm at the sample positions between 1600 mm to 2100 mm. 11-ID-C has received arrays of 435 lenses that focus 106 keV X-rays to a vertical height of 2.0 µm at the sample position. In both cases, the flux density gain in the focal spot is larger than a factor of 20, relative to using slits to cut the beam size. The lens setup is permanently installed and can be moved in and out of the beam during the experiment without further alignment. The lenses have enabled operando diffraction studies on interfaces in batteries and the development of pair distribution function (PDF) analysis using grazing incidence geometry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two-dimensional single crystal diamond refractive x-ray lens

The next generation light sources such as diffraction-limited storage rings and high repetition rate x-ray free-electron lasers will generate x-ray beams with significantly increased brilliance. These future machines will require X-ray optical components that are capable of handling higher instantaneous and average power densities while tailoring the properties of the x-ray beams for a variety of scientific experiments. Single crystal diamond is one of the best bulk materials for this application, because it is radiation hard, has a suitable uniform index of refraction and the best available thermal properties. In this paper we report on fabrication and experimental testing of a two-dimensional (2D) single crystal diamond compound refractive X-ray lenses (CRL). These lenses were manufactured using femto-second laser cutting and tested at the Advanced Photon Source of Argonne National Laboratory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Improved Refractive Focusing Optic

A diamond optic that can both dissipate the heat load while reducing phase profile errors of the beam will allow a more full realization of the benefits of the previous investments in light sources by allowing experiments that depend on high resolution imaging or spacial resolution. Reducing the x-ray spot size on samples will improve the quality of this information leading to better understanding of materials properties. During Phase I, we explored techniques for characterizing and improving the accuracy of the shape of diamond lenses, particularly in the apex of the parabolic curve, in order to make an optic whose optical performance exceeds what is currently available. We made efforts to reduce the lens surface roughness through a variety of dry etching methods. Additional work sought to make compound lenses with shorter focal lengths and to mount the lenses on copper supports by a variety of methods. Lastly, lenses were made and tested on the 1-BM beamline at APS.

42 ENGINEERING↗

Polished diamond X-ray lenses

High-quality bi-concave 2D focusing diamond X-ray lenses of apex-radius R = 100 µm produced via laser-ablation and improved via mechanical polishing are presented here. Both for polished and unpolished individual lenses and for stacks of ten lenses, the remaining figure errors determined using X-ray speckle tracking are shown and these results are compared with those of commercial R = 50 µm beryllium lenses that have similar focusing strength and physical aperture. For two stacks of ten diamond lenses (polished and unpolished) and a stack of eleven beryllium lenses, this paper presents measured 2D beam profiles out of focus and wire scans to obtain the beam size in the focal plane. These results are complemented with small-angle X-ray scattering (SAXS) measurements of a polished and an unpolished diamond lens. Again, this is compared with the SAXS of a beryllium lens. The polished X-ray lenses show similar figure errors to commercially available beryllium lenses. While the beam size in the focal plane is comparable to that of the beryllium lenses, the SAXS signal of the polished diamond lenses is considerably lower.

47 OTHER INSTRUMENTATION↗