Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compressor Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial Design and Experimental Results of a Novel Near-Isothermal Compressor for Heat Pump Applications

In efforts to increase the efficiency of residential and commercial air conditioners and heat pumps, it is found that the compressor has the highest electrical energy usage of the system. Therefore, it is appropriate to try to increase the efficiency of this component to reduce its energy usage. Another challenge with heat pump design is that some compressor types have drawbacks that make modulation difficult. To answer these challenges, we are developing an isothermal liquid compressor. The compressor uses propylene glycol to compress carbon dioxide. In the compression chamber the propylene glycol can enter either from the bottom to create a liquid piston for compression or it can enter through a spray nozzle at the top of the chamber. In the latter case, heat transfer from the gas to be compressed to the liquid droplets is high. This allows near isothermal operation of the compressor, which increases the efficiency by 17% to 30%, compared to adiabatic compression. In addition, the isothermal liquid compressor enables very efficient and simple part load modulation.Experimental results demonstrating the operation of the liquid compressor are presented. Initial data demonstrated a temperature rise of 7 K at pressure ratios of almost 4. For comparison at the same initial pressure, temperature, and pressure ratio, adiabatic compression would result in a temperature increase of approximately 70 K. Plotting data on a P-h diagram demonstrates that the compression started at superheated state and ended in supercritical state. Testing was later performed with repeated compressions in the superheated region of the P-h diagram at liquid flow rates of 2 x 10-3 m3/min and 2 x 10-3 m3/min to understand the limitations of the prototype for use with an actual heat pump system. This work demonstrated a novel cycle on a T-s diagram. Results from this work will be used to develop a second-generation prototype where more rapid cycling is possible.

Kowalski, Steve↗

Compressor system with heat recovery

A system includes a first working fluid compressor configured to pressurize a working fluid, and a prime mover coupled to the first working fluid compressor and configured to provide a mechanical input into the first working fluid compressor. An exhaust assembly is coupled to the prime mover and is configured to receive exhaust heat from the prime mover, the exhaust assembly including a generator configured to generate electric current based on the exhaust heat received by the exhaust assembly. A second working fluid compressor includes an electric motor electrically and synchronously coupled to the generator and configured to pressurize the working fluid.

Torrey, David Allan↗

Understanding airflow pattern and temperature distribution in domestic refrigerators – A review analyzing recent developments and bridging knowledge gaps

Refrigerators have become an essential appliance in every household, and they consume approximately 30% of total electricity among other domestic appliances such as clothes washers, dryers, and air conditioners. With the refrigerator’s comparatively high energy consumption compared with other appliances, existing research has mainly focused on improving the energy efficiency of refrigerators by changing the design of the compressor, heat exchanger, refrigerant, and insulation. However, previous studies have paid very little attention to the research and development of the temperature distribution in the refrigerator, which is a key parameter in determining energy consumption and food safety. Therefore, this review aims to present an overview of recent design developments to improve the temperature distribution and air circulation in domestic refrigerators, including static refrigerators and no-frost refrigerators. Herein, this review article discusses the various operation and design factors that can affect the air circulation and temperature uniformity of the refrigerator, including shelf arrangement, the compressor on/off cycle, thermostat settings, evaporator design, ambient conditions, door opening frequency, and product loading temperatures. Additionally, this review provides a summary of the advanced vapor compression cycle based refrigerators that are expected to provide better energy efficiency and independent temperature control in freezer and refrigerator compartments. This review elaborates on the significance of improving the performance of the domestic refrigerator in terms of temperature distribution and air circulation.

42 ENGINEERING↗

Preliminary Design of Nuclear Reactor Heat Delivery Systems: Integration with Reference Oil Refinery, Methanol Synthesis, and Hydrogen Production

The Department of Energy’s (DOE) Integrated Energy Systems (IES) program is generating comprehensive analyses validating the opportunity for using nuclear energy in a variety of applications including future clean grids, providing heat for direct use, and providing heat to help reduce emissions in chemical commodities. This work focuses on the preliminary designs of thermal delivery systems that can integrate heat produced from a nuclear core to industrial processes. The key research question that needs to be answered is: what is the prospective method for integrating nuclear generated heat energy into non-electric applications that can facilitate combined heat and power operations by advanced nuclear reactor systems? This research is a composition of case studies showing preliminary conceptual designs for thermal delivery systems integrating advanced nuclear systems with a few industrial systems including high temperature steam electrolysis, a reference oil refinery, and potential future methanol systems that supplant some natural gas use with nuclear energy. Piping and instrumentation diagrams have been developed to show the conceptual integration of nuclear systems with representative industrial systems. Different features of the configurations are dependent on the specific integration requirements including energy source conditions, demand quantity, and require energy application conditions. Design concepts are validated using thermodynamic balance calculations to verify system performance including calculating system losses during transport. Key components: pumps and compressors, heat exchangers, and network piping are reported with key design information and sizing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a reservoir having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to reservoirs and pump hydrogen back and forth to form a heat transfer device. A heat exchange device may be coupled with the reservoir or may comprise the outer surface of the reservoir to transfer heat to an object or to the surroundings. A closed loop may be configured having two reservoirs and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a reservoir having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to reservoirs and pump hydrogen back and forth to form a heat transfer device. A heat exchange device may be coupled with the reservoir or may comprise the outer surface of the reservoir to transfer heat to an object or to the surroundings. A closed loop may be configured having two reservoirs and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device for a hot water tank utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a tank having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to tanks and pump hydrogen back and forth to form a heat transfer device, such as a hot water heater. A heat transfer device may be coupled with the tank or may comprise the outer surface of the tank to transfer heat to an object or to the surroundings. A closed loop may be configured having two tanks and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

High‑performance cold‑climate heat pump using tandem compressors with and without vapor injection: Laboratory investigation and field demonstration

Cold‑climate air‑source heat pumps must maintain heating capacity and stable operation at low ambient temperatures for residential applications. This study adapts tandem single-speed compressors—proven in commercial systems —for residential CCHPs, integrating VI and validating performance across laboratory and extreme field conditions to achieve cold-climate targets. That is to achieve ≥75% of the rated heating capacity at −25.0 °C relative to 8.3 °C and heating coefficient of performance (COP) greater than 4.0 at 8.3 °C. Laboratory testing confirmed that both configurations met these targets while operating within acceptable discharge‑temperature limits. Relative to the non‑VI configuration, the VI system provided up to 15% higher heating capacity and up to 9% higher heating COP under identical conditions, yielding a 5.6–9.1% increase in heating seasonal performance factor (HSPF). Field tests in Ohio and Alaska, with minimum outdoor temperatures of −25.0 °C and −34.0 °C, respectively, showed stable operation, minimal supplemental heating (<3.2%), low defrost penalties, and consistent output. Tandem‑compressor architectures proves promising for cold-climate residential heating.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat↗

Study of Energy Saving Analysis for Different Industries

This study analyzes the energy consumption and saving performance in the industries in the U.S.A. All energy assessments implemented were for facilities whose annual energy consumptions were less than 9,000,000 kWh (small- and medium-sized industries) that belong to the manufacturing industries with Standard Industrial Classification (SIC) codes ranging from 2000 to 3999 in addition to SIC codes starting with 49. In this study, assessments are classified based on the SIC codes with recommendations analysis for each classification to get a better idea of what recommendations were suggested in each major industrial sector, knowing that 68 assessments were made, and their SIC ranged from 14 to 49. In addition, this study could be considered as a guide for energy engineers and other personnel involved in the energy assessment process. The information investigated can give a better prediction for composing better energy-demanding industries and minimizing energy consumption. More than 61 energy assessments were conducted for manufacturing facilities and analyzing the data gathered and processed. Through the research, the Fabricated Metal industry achieved the highest average kWh savings and cost savings within the industries studied in this study. According to the average gigajoule (GJ) savings, the fabricated metal industry ranked second within the studied industries. Conversely, Food and Kindred Products achieved the highest GJ energy savings within the studied industries. Overall, lighting, motors, compressors, and heating, ventilation, and air conditioning (HVAC) were the most contributing industries in a total of 547 recommendations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗

Development of a near-isothermal transcritical CO 2 compression system with a liquid piston compressor

Compressors are critical components in vapor compression cycle systems, significantly contributing to energy consumption. As global demand for HVAC&R systems rises, enhancing compressor efficiency becomes increasingly vital. This paper introduces a novel liquid piston compressor integrated with a gas cooler for the transcritical CO 2 refrigeration cycle. The liquid piston enables CO 2 refrigerant compression within various types of heat exchangers, facilitating the transfer of compression heat to the heat transfer fluid. By releasing significant heat, this compressor allows for removing or downsizing the traditional gas cooler in the refrigeration system. This paper presents the experimental performance of the first near-isothermal compressor utilizing a liquid piston in a vapor compression cycle. The critical parameters affecting heat transfer are analyzed by using a 1-D simulation model to achieve a near-isothermal compression process. The results show that the developed prototype successfully reduced the compression temperature increase from 95 K to 10 K, achieving 90 % isothermal efficiency. Furthermore, the 1-D simulation results suggest the smaller internal diameter tubes benefit the isothermal efficiency the most.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method and device for controlling heat pump

A method for controlling a heat pump is provided. A working mode of the heat pump is determined. Based on a determination that the working mode of the heat pump is a heating mode, an ambient temperature of the heat pump is determined. Based on a determination that the ambient temperature of the heat pump is higher than a first predetermined temperature, a first compressor of the heat pump is operated. Based on a determination that the ambient temperature of the heat pump is lower than the first predetermined temperature, both the first compressor and a second compressor of the heat pump are enabled to operate, in response to a two-stage thermostat. The first compressor and the second compressor are coupled in parallel. The method allows the heat pump to be suitable for a cold climate.

42 ENGINEERING↗

Multi-stage heat pump with two-phase injection for cold climate applications implementing natural refrigerants

Heat pump adoption in cold climates is limited by various technical challenges, including heat capacity degradation, compressor deterioration, and frost accumulation on the outdoor heat exchanger. Furthermore, wide-spread adoption of heat pumps with high global warming potential presents a possible environmental concern. Thus, we present a heat pump concept termed the “saturation cycle,” which uses numerous compression stages to improve energy efficiency and injects two-phase refrigerant between compression stages to dramatically reduce compressor discharge temperatures. Given the growing interest in heat pumps, there is a need for a straightforward framework for parametric evaluation of natural refrigerants in high-efficiency heat pump cycle architectures, like the saturation cycle, in adverse climates. This work develops a thermodynamic modeling framework and focuses on the application of natural refrigerants to explore the performance trends at extremely cold climates down to −25 °C. This study shows that a two-stage saturation cycle and four-stage saturation cycle can reduce the compressor discharge superheating by up to 51–57 % or 73–80 %, respectively, depending on the refrigerant. Furthermore, at −25 °C, a two-stage R-290 saturation cycle heat pump theoretically can use 25 % less power than a single-stage heat pump or can provide up to 59 % more heating capacity when using the same compressor power as the baseline single-stage heat pump. The exergetic parametric analyses show that two-phase refrigerant injection fundamentally improves the thermodynamic performance of the heat pump, reducing overall exergy destruction by 10 % compared to a vapor-injection heat pump, compared at −25 °C. Thus, the saturation cycle is a promising heat pump cycle architecture for cold climate applications due to its superior energy savings (or capacity improvement) and substantial de-superheating capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity Analysis Tool for Electrochemical Conversion of CO 2 To CO: User Guide

This is the user guide for the tool described here: Development of technologies that convert carbon dioxide (CO 2 ) into products is part of the U.S. Department of Energy's Office of Fossil Energy and Carbon Management Carbon Conversion Program portfolio. One such technology under development converts CO 2 to value-added products via electrochemical reduction, where catalysts are used on the cathode to promote CO 2 conversion across the electrochemical catalyst (ECC) cell. Broadly, the ECC is integrated with balance of plant (BOP) equipment (e.g., compressors, pumps, heat exchangers, purification units) in system configurations to produce the desired product. To guide research and development (R&D) toward advancements that may make such conversion technologies economically competitive, researchers may use sensitivity analyses related to the ECC system cost and performance, including that of the cathodic and anodic catalysts. This tool is intended to inform developers and Program in assessing proposed R&D on ECC systems early in the development process. Results will guide researchers on where efforts would be best directed. The tool may be accessed here: https://www.netl.doe.gov/energy-analysis/details?id=55293cb1-6881-4181-a2b0-d00b711ce74b.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗