Concentration measurements of an injected gas in a supersonic stream
Tracer gas technique use to measure concentration of gas injected into supersonic air stream
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Tracer gas technique use to measure concentration of gas injected into supersonic air stream
Despite intensive research over a number of years, an understanding of scalar mixing in turbulent flows remains elusive. An understanding is required because turbulent mixing has a pivotal role in a wide variety of natural and technologically important processes. As an example, the mixing and transport of pollutants in the atmosphere and in bodies of water are often dependent on turbulent mixing processes. Turbulent mixing is also central to turbulent combustion which underlies most hydrocarbon energy use in modern societies as well as in unwanted fire behavior. Development of models for combusting flows is therefore crucial, however, an understanding of scalar mixing is required before useful models of turbulent mixing and, ultimately, turbulent combustion can be developed. An important subset of turbulent flows is axisymmetric turbulent jets and plumes because they are relatively simple to generate, and because the provide an appropriate test bed for the development of general theories of turbulent mixing which can be applied to more complex geometries and flows. This paper focuses on a number of experimental techniques which have been developed at the National Institute of Standards and Development for measuring concentration in binary axisymmetric turbulent jets. In order to demonstrate the value of these diagnostics, some of the more important results from earlier and on-going investigations are summarized. Topics addressed include the similarity behavior of variable density axisymmetric jets, the behavior of absolutely unstable axisymmetric helium jets, and the role of large scale structures and scalar dissipation in these flows.
Ionospheric electron concentration measuring probe techniques compared based on rocket flight data, showing practicability of spherical probe HF capacitance utilization
A nonintrusive concentration measurement method is developed for determining the concentration distribution in a complex flow field. The measurement method consists of marking a liquid flow with a water soluble fluorescent dye. The dye is excited by a two dimensional sheet of laser light. The fluorescent intensity is shown to be proportional to the relative concentration level. The fluorescent field is recorded on a video cassette recorder through a video camera. The recorded images are analyzed with image processing hardware and software to obtain intensity levels. Mean and root mean square (rms) values are calculated from these intensity levels. The method is tested on a single round turbulent jet because previous concentration measurements have been made on this configuration by other investigators. The previous results were used to comparison to qualify the current method. These comparisons showed that this method provides satisfactory results. 'Me concentration measurement system was used to measure the concentrations in the complex flow field of a model gas turbine annular combustor. The model annular combustor consists of opposing primary jets and an annular jet which discharges perpendicular to the primary jets. The mixing between the different jet flows can be visualized from the calculated mean and rms profiles. Concentration field visualization images obtained from the processing provide further qualitative information about the flow field.
The effect of pressure on the laser-saturated fluorescence method for measuring OH concentration in high-pressure flames is studied using calculations for the burned-gas region of a stoichiometric H2-O2 flame at 2000 K. A numerical model of the excitation dynamics of OH is developed to explore the validity of the balanced cross-rate model at higher pressures. It is shown that depopulation of the laser-coupled levels is sensitive to collisions which depopulate v-double-prime (VDP) = 0 and to rate coefficients for rotational transfer in the ground state which are smaller than those in the excited state. In particular, it is shown that the depopulation of VDP = 0, and hence the laser-coupled levels, depends on the probability of electronic quenching to vibrational levels for which VDP is greater than 0 and vibrational relaxation to VDP = 0.
Hydrogen and ammonia represent two carbon-free fuel sources that could be used in place of current fossil energy sources in combustion systems. To develop optimized ammonia combustion systems, validated modeling tools are needed. In the open literature, it has been shown that the complex chemistry associated with fuel-bound nitrogen contained in ammonia differs greatly from natural gas or hydrogen combustion. As a result, several new chemical kinetic mechanisms have been developed. Many of these mechanisms have been validated experimentally, however this has primarily focused on bulk parameters such as laminar flame speed and ignition delay time. Critically, high quality measurements of species concentrations are needed under controlled conditions which are easily represented by simple models. In this paper, direct, in-situ measurements of species concentrations and gas temperature are performed in a laminar flat-flame burner. This arrangement enables comparison with 1D model predictions, better isolating chemical kinetics from the fluid dynamics. Quantitative species concentrations are determined by absorption spectroscopy using an FTIR spectrometer. Fuel compositions representative of cracked ammonia (NH 3 /H 2 ) and ammonia-natural gas (NH 3 /CH 4 ) are considered for rich and lean equivalence ratios. A major focus of the paper is on the selection of spectral features for nitric oxide and ammonia and correcting for large amounts of baseline H 2 O absorption.
A 2-micron pulsed, Integrated Path Differential Absorption (IPDA) lidar instrument for ground and airborne atmospheric CO2 concentration measurements via direct detection method is being developed at NASA Langley Research Center. This instrument will provide an alternate approach to measure atmospheric CO2 concentrations with significant advantages. A high energy pulsed approach provides high-precision measurement capability by having high signal-to-noise level and unambiguously eliminates the contamination from aerosols and clouds that can bias the IPDA measurement.
Airborne photometer measures absorption of ultraviolet. Automatically measures ozone concentrations in atmosphere to accuracy within 10 parts per billion. Air collected outside airplane enters photometer by way of transfer valve. Pressure and temperature of air measured simultaneously with transmissivity of air to ultraviolet light from lamp. Instrument has mass of 20.5 kg and fits in aluminum box measuring 78 by 58 by 25 cm. Compact, lightweight, low-power instrument developed for use on high-altitude research airplane.
Lower E-region positive ion concentrations measured at time of declining solar activity by rocket installed mass spectrometer
Mixing and combusting high enthalpy flows, similar to those encountered in scramjet engines, were investigated using a shock tunnel to produce the flow in conjunction with non-intrusive optical diagnostics which monitored the performance of two injector configurations. The shock tunnel is configured to produce Mach 3 flow and stagnation enthalpies corresponding to flight equivalent Mach numbers between 7 and 11. A pulsed hydrogen injection capability and interchangeable injector blocks provide a means of examining high speed, high enthalpy reacting flows. Planar laser induced fluorescence (PLIF) of OH molecules in the near injector region produced images which show the combusting and mixing zones for the reacting flow. Line-of-sight exit plane measurement of water concentration and temperature were used to provide a unique method of monitoring exit plane products. These results demonstrated that a velocity matched axial injection system produced a fuel jet that lifted off the floor of the duct. Mixing was observed to increase for this system as a velocity mismatch was introduced. Comparison of exit plane water concentrations for a wall jet injection system and a velocity matched injection system indicated similar mixing performance but an accurate pressure measurement is necessary to further validate the result. In addition, exit plane measurements indicated an approximate steady-state condition was achieved during the 1 to 2 ms test times.
A high speed two wavelength holographic interferometer is being used to simultaneously measure temperature and concentration distributions for ignition and flame spread. Lines from a cw CO2 laser were used and the holograms recorded on a movie at 500 frames per/sec, individual frames were digitized with a microdensitometer. The detection on the fringe center was a major problem.
Theoretical and experimental results for using the photothermal deflection technique to measure vapor species concentration, while minimizing the disturbance of the transport (material) parameters due to vapor heating, are developed and described. In contrast to common practice, the above constraints require using a pump-beam duty cycle of less than 50 percent. The theoretical description of the shortened heating time is based on a step-function formulation of the pumping cycle. The results are obtained as closed-form solutions of the energy equation for many chopping cycles until steady state is reached, by use of a Green's-function method. The Euler formulation of the Fermat principle is used to calculate the deflection angle. The equations are expanded to include the effects of vapor velocity on both the temperature and temperature gradient profiles. The effects of finite (unfocused) pump and probe beams and thermal (Soret) diffusion are also accounted for. Excellent agreement between theory and experiment is obtained.
The development of lab-on-a-chip devices for microscale biochemical assays has led to the need for microscale concentration measurements of specific analyses. While fluorescence methods are the current choice, this method requires developing fluorophore-tagged conjugates for each analyte of interest. In addition, fluorescent imaging is also a volume-based method, and can be limiting as smaller detection regions are required.
A Kalman filtering technique is applied to the simultaneous detection of NH3 and CO2 with a diode-laser-based sensor operating at 1.53 micrometers. This technique is developed for improving the sensitivity and precision of trace gas concentration levels based on direct overtone laser absorption spectroscopy in the presence of various sensor noise sources. Filter performance is demonstrated to be adaptive to real-time noise and data statistics. Additionally, filter operation is successfully performed with dynamic ranges differing by three orders of magnitude. Details of Kalman filter theory applied to the acquired spectroscopic data are discussed. The effectiveness of this technique is evaluated by performing NH3 and CO2 concentration measurements and utilizing it to monitor varying ammonia and carbon dioxide levels in a bioreactor for water reprocessing, located at the NASA-Johnson Space Center. Results indicate a sensitivity enhancement of six times, in terms of improved minimum detectable absorption by the gas sensor.
A holographic technique for the simultaneous measurement of temperature and concentration in solidifying transparent model alloy systems was developed. Its application to the study of the interactions between the temperature, concentration, and fluid flow fields in such systems at 1 g and micro-g conditions is discussed.
Atom concentrations produced by microwave discharge in nitrogen and hydrogen
Measurements of temperature and CO2 concentration using dual-pump coherent anti-Stokes Raman scattering, (CARS) are described. The measurements were performed in laboratory flames,in a room-temperature gas cell, and on an engine test stand at the U.S. Air Force Research Laboratory, Wright-Patterson Air Force Base. A modeless dye laser, a single-mode Nd:YAG laser, and an unintensified back-illuminated charge-coupled device digital camera were used for these measurements. The CARS measurements were performed on a single-laser-shot basis. The standard deviations of the temperatures and CO2 mole fractions determined from single-shot dual-pump CARS spectra in steady laminar propane/air flames were approximately 2 and 10% of the mean values of approximately 2000 K and 0.10, respectively. The precision and accuracy of single-shot temperature measurements obtained from the nitrogen part of the dual-pump CARS system were investigated in detail in near-adiabatic hydrogen/air/CO2 flames. The precision of the CARS temperature measurements was found to be comparable to the best results reported in the literature for conventional two-laser, single-pump CARS. The application of dual-pump CARS for single-shot measurements in a swirl-stabilized combustor fueled with JP-8 was also demonstrated.
Lower ionosphere electron concentration profiles, comparing rocket measurements on winter days of normal and anomalous absorption