Search NASA⌕ Search

SEARCH · Search NASA

Results for “Conductivity and Viscosity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Density, Electrical Conductivity and Viscosity of Hg(0.8)Cd(0.2)Te Melt

The density, viscosity, and electrical conductivity of Hg(0.8)Cd(0.2)Te melt were measured as a function of temperature. A pycnometric method was used to measure the melt density in the temperature range of 1072 to 1122 K. The viscosity and electrical conductivity were determined using a transient torque method from 1068 to 1132 K. The density result from this study is within 0.3% of the published data. However, the current viscosity result is approximately 30% lower than the existing data. The electrical conductivity of Hg(0.8)Cd(0.2)Te melt as a function of temperature, which is not available in the literature, is also determined. The analysis of the temperature dependent electrical conductivity and the relationship between the kinematic viscosity and density indicated that the structure of the melt appeared to be homogeneous when the temperature was above 1090 K. A structural transition occurred in the Hg(0.8)Cd(0.2)Te melt as the temperature was decreased to below 1090 K

Li, C.↗

Density, Electrical Conductivity and Viscosity of Hg(sub 0.8)Cd(sub 0.2)Te Melt

The density, viscosity, and electrical conductivity of Hg(sub 0.8)Cd(sub 0.2)Te melt were measures as a function of temperature. A pycnometric method was used to measure the melt density in the temperature range of 1072 to 1122 K. The viscosity and electrical conductivity were determined using a transient torque method from 1068 to 1132 K. The density result from this study is within 0.3% of the published data. However, the current viscosity result is approximately 30% lower than the existing data. The electrical conductivity of Hg(sub 0.8)Cd(sub 0.2)Te melt as a function of temperature, which is not available in the literature, is also determined. The analysis of the temperature dependent electrical conductivity and the relationship between the kinematic viscosity and density indicated that the structure of the melt appeared to be homogeneous when the temperature was above 1090 K. A structural transition occurred in the Hg(sub 0.8)Cd(sub 0.2)Te melt as the temperature was decreased to below 1090 K.

Li, C.↗

A Model for Hydrogen Thermal Conductivity and Viscosity Including the Critical Point

In order to conduct a thermal analysis of heat transfer to liquid hydrogen near the critical point, an accurate understanding of the thermal transport properties is required. A review of the available literature on hydrogen transport properties identified a lack of useful equations to predict the thermal conductivity and viscosity of liquid hydrogen. The tables published by the National Bureau of Standards were used to perform a series of curve fits to generate the needed correlation equations. These equations give the thermal conductivity and viscosity of hydrogen below 100 K. They agree with the published NBS tables, with less than a 1.5 percent error for temperatures below 100 K and pressures from the triple point to 1000 KPa. These equations also capture the divergence in the thermal conductivity at the critical point

Wagner, Howard A.↗

Thermophysical Properties of Liquid Te: Density, Electrical Conductivity, and Viscosity

The thermophysical properties of liquid Te, namely, density, electrical conductivity, and viscosity, were determined using the pycnometric and transient torque methods from the melting point of Te (723 K) to approximately 1150 K. A maximum was observed in the density of liquid Te as the temperature was increased. The electrical conductivity of liquid Te increased to a constant value of 2.89 x 10(exp 5 OMEGA-1m-1) as the temperature was raised above 1000 K. The viscosity decreased rapidly upon heating the liquid to elevated temperatures. The anomalous behaviors of the measured properties are explained as caused by the structural transitions in the liquid and discussed in terms of Eyring's and Bachiskii's predicted behaviors for homogeneous liquids. The Properties were also measured as a function of time after the liquid was coded from approximately 1173 or 1123 to 823 K. No relaxation phenomena were observed in the properties after the temperature of liquid Te was decreased to 823 K, in contrast to the relaxation behavior observed for some of the Te compounds.

Li, C.↗

Physics and Chemistry of Te and HgTe-based Ternary Melts

Historically, the theoretical treatment of the liquid phases has always been more difficult and complicated than that for solid and gas phases. A liquid has no lattice structure as crystalline solids and the atoms/molecules in the liquid can migrate through it relatively rapidly. On the other hand, it is also interacting with many other atoms/molecules so that the simplifications of the kinetic theory of gases cannot be employed. For more complicated liquids, such as the liquids of high ionicity and those containing hydrogen bonds and electric dipoles, the understanding is far from complete. At the same time, accurate information on the physics and chemistry of semiconductor melts is needed for the quantitative descriptions of the process of crystal growth from melt. The pre-crystallization phenomena in the liquid phase are critical because the properties of the grown crystals depend on the state and structure of the melt as well as the thermal history of the melt during solidification process. However, the data on the liquid phase, such as thermophysical properties of semiconductor melts are scarce, especially for the HgTe-based II-VI ternary compound semiconductors because of their high vapor pressure and extreme toxicity. Analysis of the thermophysical properties of the melt can provide information about structural transitions of the melt during the solidification process. From a broader point of view, the structure of liquids is much more complicated than the crystalline solids, especially the relaxation behavior through different thermal histories. The theory of hetero-phase fluctuations of liquids is applicable to any many-body systems including condensed-matter physics, field theory, physics of nuclear-matter, cosmology, biology and even sociology. This book summarizes the physics and chemistry from the experimental measurements and theoretical analyses of phase diagram, thermodynamic properties, density, thermal conductivity, viscosity, and electrical conductivity on the binary, pseudo-binary and ternary melts of the most advanced IR-detector material systems of HgCdTe and HgZnTe as well as the analyses of these results. The main objectives of this study are: (1) to provide the phase diagrams and thermodynamic properties of Hg-Cd-Te and Hg-Zn-Te systems through quantitatively fitting the experimental data by assuming an associated solution model for the liquid phase, (2) to experimentally measure the thermophysical properties of the Hg-Cd-Te and Hg-Zn-Te melts, including density, viscosity, electrical conductivity and thermal conductivity as functions of temperature and composition and (3) to enhance the fundamental knowledge of hetero-phase fluctuations and relaxation phenomena in the melts and extend our understanding of the solidification process in order to interpret the experimental results of crystal growth so as to improve the melt growth processes of the compound semiconductor. The physics and chemistry of Te and HgTe-based ternary melts were explored through the studies of the structural transformation during melting, the supercooling during solidification, the relaxation phenomena after rapid cooling of the melts and the metal-semiconductor transition in the melts through the analyses of electrical conductivity and Lorenz number. An in-depth study on the thermophysical properties and their time-dependent structural dynamic processes taking place in the vicinity of the solid-liquid phase transition of the narrow homogeneity range HgTe-based ternary semiconductors as well as the analysis of the homogenization process in the melt will also be presented.

Thermophysical properties↗

Role of Compressive Viscosity and Thermal Conductivity on the Damping of Slow Waves in Coronal Loops with and Without Heating–Cooling Imbalance

In the present article, we derive a new dispersion relation for slow magnetoacoustic waves invoking the effect of thermal conductivity, compressive viscosity, radiation, and an unknown heating term along with the consideration of heating–cooling imbalance from linearized MHD equations. We solve the general dispersion relation to understand the role of compressive viscosity and thermal conductivity in the damping of slow waves in coronal loops with and without heating–cooling imbalance. We have analyzed the wave damping for the range of loop length L=50--500 Mm, temperature T=5--30 MK, and density ρ=10^(−11)--10^(−9) kg/cu.m. It was found that the inclusion of compressive viscosity along with thermal conductivity significantly enhances the damping of the fundamental mode oscillations in shorter (e.g. L=50 Mm) and super-hot (T>10 MK) loops. However, the role of viscosity in the damping is insignificant in longer (e.g. L=500 Mm) and hot loops (T≤10 MK) where, instead, thermal conductivity along with the presence of heating–cooling imbalance plays a dominant role. For shorter loops at a super-hot regime of temperature, the increment in the loop density substantially enhances the damping of the fundamental modes due to thermal conductivity when viscosity is absent, however, when the compressive viscosity is added the increase in density substantially weakens the damping. Thermal conductivity alone is found to play a dominant role in longer loops at lower temperatures (T≤10 MK), while compressive viscosity dominates the damping at super-hot temperatures (T>10 MK) in shorter loops. The predicted scaling law between damping time (τ) and wave period (P) is found to better match the observed SUMER (Solar Ultraviolet Measurements of Emitted Radiation) oscillations when the heating–cooling imbalance is taken into account in addition to thermal conductivity and compressive viscosity for the damping of the fundamental slow mode oscillations.

Abhinav Prasad↗

Space-based laser-driven MHD generator: Feasibility study

The feasibility of a laser-driven MHD generator, as a candidate receiver for a space-based laser power transmission system, was investigated. On the basis of reasonable parameters obtained in the literature, a model of the laser-driven MHD generator was developed with the assumptions of a steady, turbulent, two-dimensional flow. These assumptions were based on the continuous and steady generation of plasmas by the exposure of the continuous wave laser beam thus inducing a steady back pressure that enables the medium to flow steadily. The model considered here took the turbulent nature of plasmas into account in the two-dimensional geometry of the generator. For these conditions with the plasma parameters defining the thermal conductivity, viscosity, electrical conductivity for the plasma flow, a generator efficiency of 53.3% was calculated. If turbulent effects and nonequilibrium ionization are taken into account, the efficiency is 43.2%. The study shows that the laser-driven MHD system has potential as a laser power receiver for space applications because of its high energy conversion efficiency, high energy density and relatively simple mechanism as compared to other energy conversion cycles.

Choi, S. H.↗

Morphological controls on flow conductivity and viscosity of bentonite–polymer composites

In this study, the authors investigate the morphological organisation of polymers in bentonite–polymer composites (BPCs) used in geosynthetic clay liners and controls on hydraulic conductivity and viscosity. A limited understanding of the relationship between the microstructure of BPCs and their macroscopic engineering behaviour motivates this study. The polymer resides in the inter-granular pores of bentonite based on synchrotron-based small-angle X-ray scattering measurements, scanning electron microscopy imaging and pore size analyses. On wetting, the polymer swells to produce a swollen hydrogel residing in the inter-granular pores. Enhanced tortuosity arising from hydrogel formation reduces the hydraulic conductivity of BPCs. The higher viscosity of the BPC slurry is attributed to the higher shear resistance emerging from swelling of the polymer fraction on wetting. These findings link the morphological features of BPCs to the observed hydraulic conductivity and viscosity of these materials.

Engineering↗

FY23 Progress Report on Viscosity and Thermal Conductivity Measurements of Molten Salts

As presented in this report, thermal conductivity and viscosity measurements were performed on key chloride pseudo-binary molten salt systems of relevance to molten salt reactor developers. Thermal conductivity measurements were conducted with a variable gap technique, in which a known heat flux is driven across a molten salt specimen and the temperature difference is measured, allowing calculation of the thermal conductivity. This is achieved by establishing a small gap between the bottom of a cylindrical inner containment, which houses electrical heating elements, and an outer containment, which houses cooling channels; the gap size can be varied by compression of a formed bellows. A new calibration scheme was developed herein, involving a correction factor to the heat flux based on He measurements at various temperatures. Furthermore, the data processing methodology was improved to minimize the impact of radiative heat transfer in the calculation of salt specimen thermal conductivity from the temperature difference measurements. Viscosity measurements were conducted with a rolling ball viscometer, in which a ball rolls some known distance in an angled tubular crucible, and the terminal velocity can be used to calculate the viscosity of the salt. The measurement can be performed in a quartz crucible, with which a standard camera can be used to track the ball, or in a metal crucible, with which x-ray radiography is required to track the ball. A new custom x-ray system was made and dedicated to the rolling ball viscometer to enable high throughput automated measurements with salts which require containment with metal. Both systems have been integrated with a ventilation stack which allows for off-gassing of radioactive material, enabling future measurements with U-bearing salts. The thermal conductivity measurements performed herein were with NaCl-KCl (44 mol% NaCl). This salt system was measured in the previous fiscal year, however the thermal conductivity values obtained were comparatively low, and so the system was remeasured with the aforementioned calibration scheme and improved post-processing techniques. The newly obtained thermal conductivity values for NaCl-KCl (44 mol% NaCl) indicate good agreement with kinetic theory and ab-initio models (within 5–10 %). The viscosity measurements performed herein were with three different compositions of NaCl-KCl: 75, 50, and 25 mol% NaCl; a new calibration scheme was applied to account for variable flow effects in the laminar regime. The results show reasonable agreement with literature (5–20 %, depending on the temperature, composition, and study); however, literature values are likely higher than true values based on pure end-member measurements performed in the comparative studies. The measurements conducted herein do show a trend such that viscosity increases with increasing NaCl concentration, which agrees well with one of two comparative studies. In general, the measurements conducted herein gives confidence in the capability to use these systems to accurately measure thermal conductivity and viscosity of actinide-bearing salts within the next fiscal year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Alignment Charts for Transport Properties Viscosity, Thermal Conductivity, and Diffusion Coefficients for Nonpolar Gases and Gas Mixtures at Low Density

Alignment charts (nomographs) designed to permit rapid calculations of the low-pressure transport properties of nonpolar gases and gas mixtures are presented. Calculations for pure gases are based on the rigorous kinetic theory of gases as applied to a realistic intermolecular force law. Mixture viscosities and conductivities are calculated from good approximations derived from rigorous theory. The properties are calculable with a precision of 2 percent or better. Accuracy depends on how well the constants characterizing the Intermolecular force law are known; if constants are derived from experimental data, results should be accurate to 5 percent or better. Force constants are tabulated for 65 gases.

Brokaw, Richard S.↗

FY2022 Progress Report on Viscosity and Thermal Conductivity Measurements of Molten Salts

This report describes the development of and experimental measurements made with the thermal conductivity and viscosity measurement systems for molten salts at Oak Ridge National Laboratory. The thermal conductivity system is based on a steady-state measurement technique in which a heat flux is driven across a variable gap, and the changes in temperature difference across the gap are measured as the gap size is varied. The system comprises an inner containment, which possesses the heating element, and an outer containment, which possesses the salt specimen and cooling channels. The gap is formed between the outer bottom of the inner containment and the inner bottom of the outer containment. The viscosity system is based on the falling-ball technique in which a salt-filled tubular crucible is fixed at an angle and a ball rolls through the salt. The terminal velocity of the ball can be converted into viscosity via a calibration factor calculated for crucible-ball combinations which account for thermal expansion and flow characteristics. Modifications were made to both systems this fiscal year. Modifications to the thermal conductivity system included adding guard heaters to prevent axial heating losses, and modifications to the viscosity system included changing the crucible design to prevent air pocket formation and providing the ability to conduct measurements with a glass or steel crucible.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of eddy viscosity and thermal conduction and Coriolis force in the dynamics of gravity wave driven fluctuations in the OH nightglow

The chemical-dynamical model of Walterscheid et al. (1987), which describes wave-driven fluctuations in OH nightglow, was modified to include the effects of both eddy thermal conduction and viscosity, as well as the Coriolis force (with the shallow atmosphere approximation). Using the new model, calculations were performed for the same nominal case as used by Walterscheid et al. but with only wave periods considered. For this case, the Coriolis force was found to be unimportant at any wave period. For wave periods greater than 2 or 3 hours, the inclusion of thermal conduction alone greatly modified the results (in terms of a complex ratio 'eta' which expresses the relationship between the intensity oscillation about the time-averaged intensity and the temperature oscillation about the time-averaged temperature); this effect was reduced with the further inclusion of the eddy viscosity.

Hickey, M. P.↗

Transient Torque Technique for Viscosity and Electrical Conductivity Determination of Semiconducting Liquids

A novel apparatus based on transient torque technique is constructed in MSFC/NASA. The apparatus uses a 125um diameter quartz fiber as torsion wire. A high sensitive angular detector is implemented to measure the deflection angle of the crucible containing the liquid. A rotating magnetic field (RMF) is used to induce a rotating flow of a conducting or semiconducting melts. By measuring the magnitude and transient behavior of the induced deflection angle, the electrical conductivity and viscosity of the melt can be measured simultaneously. High purity elements namely Hg, Ga, Zn and Te are tested at room temperature and high temperature up to 900 C.

Li, C.↗

Electrochemical, thermodynamic, and physical properties of tetradecyltrihexylphosphonium ([P 6,6, 6,14 ] + ) and methyl-propyl piperidinium containing ionic liquids and their propylene carbonate solutions

Here, the viscosity, conductivity, electrochemical window and related thermodynamic properties such as excess volume and dynamic viscosity deviation of two phosphonium ionic liquids were measured and calculated for “as-supplied” and dried neat liquids and also v/v mixtures of 99/1, 95/5, 90/10, 75/25, and 50/50 of the ionic liquids with propylene carbonate (PC). Tetradecyltrihexylphosphonium dicyanamide ([P 6,6,6,14 ] + dicyanamide), Cyphos 105, and tetradecyltrihexylphosphonium bis(trifluororomethanesulfonyl)imide (called bistriflimide) ([P 6,6,6,14 ] + bistriflimide), Cyphos 109, ionic liquids were studied. Generally speaking, there were slight differences in the measured properties of the wet and dried IL solutions which were reflected in differences if the calculated properties. The measured and calculated properties were compared with those collected and derived from a piperidinium-based ionic liquid, methyl-propyl piperidinium bistriflimide. Arrhenius plots for both the viscosity and conductivity were linear, with the linearity of the Litovitz plots being slightly higher. The viscosity and conductivity of the phosphonium solutions yielded Walden Plots that differed from Walden plots of piperidinium solutions and other ionic liquid solutions. For the phosphonium based ionic liquids, the ionicity was found to increase with increasing dilution in propylene carbonate. The electrochemical windows of the ionic liquids were determined as a function of the concentration of the ionic liquid present in the solution. The size of the window generally initially decreased and then increased with the addition of PC for the [P 6,6,6,14 ] + dicyanamide ionic liquid increasing from 3.4 V in the 95/5 v/v (volume Cyphos 105) to volume of PC solvent) to 3.7 in the 50/50 dried IL case. The electrochemical windows of the dried liquids were slightly larger 3.5 V for the 95/5 v/v and 4.2 V for the 50/50 v/v Cyphos 105/PC solutions. The electrochemical window was larger and the conductivity was higher for the piperidinium IL solutions, but since the ionicity increases with dilution, the phosphonium based IL solutions may prove favorable for processes such as electrochemical reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗