Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contact angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Interference fringe (IF) technique for droplet contact angle and thickness measurements: Ultralow contact angle and nanoscale thickness measurement

Recently, reflection interference fringe (RIF) and transmission fringe (TIF) techniques have been introduced to investigate the origin of far-field interference fringe (IF) formation and to determine a droplet's contact angle and thickness by measuring the fringe radius. In this study, characteristics of the IF technique are analyzed based on the RIF and TIF by varying the schematics, such as configuration (transmission/reflection), the droplet's side (left-hand side/right-hand side), and the substrate types (flat/prism). The analysis also investigates the refraction effect at the droplet edge and the maximum incidence and contact angles. The schematic variation shows that the widest contact angle range can be measured in a transmission configuration with droplet's right-hand side, and that the fringe radius decreases with incidence angles on a prism substrate, consistent with the recent observation. Refraction at the droplet edge causes the fringe radius to increase or decrease depending on the degree of refraction. Based on the characteristics study, it is revealed that the IF technique can determine nanometer-scale thicknesses below 100 nm on droplets, corresponding to ultra-small contact angles of less than 0.01°, with an extended working distance of 3000 mm and an optimized incidence angle, assuming a spherical profile. This finding is significant, as it demonstrates that the nanoscale thickness can be determined in situ under ambient conditions using a simple optical configuration, without requiring a sophisticated setup, such as a microscope. It is anticipated that the IF technique can be combined with other nanoscale thickness measurement techniques to enhance its measurement reliability.

36 MATERIALS SCIENCE↗

Hydrodynamics of countercurrent flows in a structured packed column: effects of initial wetting and dynamic contact angle

The structured packed column has gained considerable attention as a prospective technology to mitigate carbon dioxide emissions from thermal power plants. The computational flow investigation of such systems is a multiscale problem, and local hydrodynamics plays a key role in overall column efficiency. Accordingly, multiphase flow studies in the representative elementary unit (REU) of a packed column can offer insights into the local flow behavior such as flow pattern, interfacial area, etc. The interfacial area plays a key role in the overall interphase mass transfer and thereby in separation efficiency. The predicted effective area matches well with corresponding ones in experiments for Mellapak 250.Y packings. The contact angle (i.e., solid substrate behavior) is one of the critical factors that dictates wettings, and thereby the interfacial area. The dynamic contact angle (DCA) was considered in order to explore the effects of contact angle hysteresis on the interfacial area. DCA has more pronounced impact on the interfacial area for a solvent possessing a higher value of surface tension and equilibrium contact angle. The interfacial area shows temporal undulation and does not achieve a pseudo steady state due to the capillary force. In contrary, the interfacial area gets a net value for a solvent having low surface tension value. Further, specification of the static contact angle at the solid substrate shows the least value of the interfacial area. We also extensively studied the effect of the initial sheet condition (dry vs wet) on the interfacial area. The initially wetted sheets show slightly higher value of the interfacial area as compared to the initially dry sheets at a fixed flow rate for a solvent having high surface tension value. Wetting hysteresis decreases with increasing liquid loads. On the other hand, wetting hysteresis does not occur for a solvent having value of low surface tension and equilibrium contact angle.

structured packings, dynamic contact angle, interf↗

Systematic Oxidation of Polystyrene by Ultraviolet-Ozone, Characterized by Near-Edge X-ray Absorption Fine Structure and Contact Angle

The process of implanting oxygen in polystyrene (PS) via exposure to ultraviolet-ozone (UV-O) was systematically investigated using the characterization technique of near-edge X-ray absorption fine structure (NEXAFS). Samples of PS exposed to UV-O for 10-300 s and washed with isopropanol were analyzed using the carbon and oxygen K-edge NEXAFS partial electron yields, using various retarding bias voltages to depth-profile the oxygen penetration into the surface. Evaluation of reference polymers provided a scale to quantify the oxygen concentration implanted by UV-O treatment. We find that ozone initially reacts with the double bonds on the phenyl rings, forming carbonyl groups, but within 1 min of exposure, the ratio of double to single oxygen bonds stabilizes at a lower value. Oxygen penetrates the film with relative ease, creating a fairly uniform distribution of oxygen within at least the first 4 nm (the effective depth probed by NEXAFS here). Before oxygen accumulates in large concentrations, however, it preferentially degrades the uppermost layer of the film by removing oxygenated low-molecular-weight oligomers. The failure to accumulate high concentrations of oxygen is seen in the nearly constant carbon edge jump, the low concentration of oxygen even at 5 min exposure (58% of that in poly(4-acetoxystyrene), the polymer with the most similarities to UV-O-treated PS), and the relatively high contact angles. At 5 min exposure the oxygen concentration contains ca. 7 atomic % oxygen. The oxygen species that are implanted consist predominantly of single O-C bonds and double OC bonds but also include a small fraction of O-H. UV-O treatment leads a plateau after 2 min exposure in the water contact angle hysteresis, at a value of 67 {+-} 2, due primarily to chemical heterogeneity. Annealing above Tg allows oxygenated species to move short distances away from the surface but not diffuse further than 1-2 nm.

36 MATERIALS SCIENCE↗

Multiscale water drop contact angles at selected silica surfaces

In this paper, multiscale advancing contact angles for glycerol/water drops at silica surfaces are reported for millidrops, submicron-drops, and nanodrops. Selected silica surfaces were muscovite, silicon, and talc. The contact angles for millidrops (1–2 mm) were determined by the traditional sessile drop technique. For submicron-drops (0.1–1.0 μm), a hollow tip Atomic Force Microscope (AFM) procedure was used. The contact angles for nanodrops (~7 nm) were examined from Molecular Dynamics (MD) simulation. The results were compared to evaluate the effect of drop size on the contact angle. In the case of the hydrophobic talc surface, the 75° advancing contact angle did not vary significantly with drop size. For the hydrophilic muscovite surface, the water drop wet the surface and an advancing contact angle of about 10° was found for the millidrops and submicron-drops. However, for the MD simulated nanodrops, attachment and spreading of the ~7 nm drop created a 2D film of molecular dimensions, the contact angle of which was difficult to define and varied from 0° to 17°. Perhaps of equal interest from the MD simulation results was that the spreading of the glycerol/water nanodrop at the muscovite surface resulted in crystallographic directional transport of water molecules to the extremities of the 2D film. Such separation and segregation left the center of the film with an increased concentration of glycerol. Based on these results, the line tension, which has been found in other investigations to account for contact angle decrease with a decrease in drop size, does not seem to be a significant factor in this study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient analysis of advancing contact angle measurements on polished rock surfaces

We report that contact angle measurements for gas-liquid-rock systems are important for modeling multi-phase flow and transport in the subsurface. These data are needed in applications such as the extraction of oil and gas resources, geologic sequestration of carbon dioxide, contaminant fate and transport, and aquifer recharge through the vadose zone. Contact angles are frequently measured with the sessile drop method. Previous research has largely ignored the dynamic behavior of sessile droplets on geologic materials. This study investigates the dynamic behavior of sessile water droplets on prepared rock surfaces in the presence of air. Droplet diameter and advancing contact angle were determined at 0.5 s intervals for ~90 s on flat polished disks of Burlington limestone, Crossville sandstone, Mancos shale, Sierra White granite, Vermilion Bay granite, and Westerly granite using a Krüss DSA 30 Drop Shape Analyzer. The droplet diameter and advancing contact angle data sets were nonlinearly regressed against time using two different two-parameter models. The median coefficients of determination for the fits were 0.85 and 0.96, respectively. The resulting parameter estimates were used to compute the apparent equilibrium contact angle, θ e , for each disk following droplet diameter stabilization. Estimates of θ e ranged from 37.2° for Mancos shale to 75.6° for Burlington limestone. Analysis of variance indicated statistically significant differences in θ e between the rock types at the 95% confidence level. The variability of θe on the polished rock surfaces, as quantified by the coefficient of variation (CV) for θ e , varied between ~3 and ~9%; there were no significant differences in CV between the rock types. Neutron radiography indicated changes droplet morphology over time were due to the spontaneous imbibition of water into the rock matrix. Finally, the transient analysis employed in this study permits a more meaningful estimate of the equilibrium contact angle for rocks than taking the initial value or averaging over time as is frequently done.

58 GEOSCIENCES↗

Technique to measure contact angle of micro/nanodroplets using atomic force microscopy

Contact angle is the primary parameter that characterizes wetting; however, the measurement techniques have been limited to droplets with a diameter as low as about 50 {mu}m. The authors developed an atomic force microscopy-based technique to measure the contact angle of micro- and nanodroplets deposited using a modified nanoscale dispensing tip. The obtained contact angle results were compared with those of a macrodroplet (2.1 mm diameter). It was found that the contact angle on various surfaces decreases with decreasing the droplet size.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental measurement of the effective contact angle for solvent/packing interactions in a structured packed column for CO 2 capture

The contact angle is a critical factor for determining the effective mass transfer area for carbon dioxide (CO 2 ) capture via the chemical absorption process in a packed column, and thus the overall capture efficiency of the packed column. Many widely used commercial packings involve microscale features (perforation, corrugation, etc.) that may also affect the wetting behavior. This study proposes a systematic method of using a modified Wilhelmy plate to measure the effective contact angle to characterize the solvent and featured packing interaction. In lieu of computational efforts relying on assumptions guided by semi-informed correlation, the proposed method directly measures the effective contact angle as a function of the solvent and packing thermophysical and hydrodynamic properties. The characterization of the effective contact angle is then integrated in the computational fluid dynamics modeling to reduce uncertainty in the prediction of effective mas transfer area. Experiments were conducted for stainless steel coupons using water and aqueous sodium hydroxide (NaOH) solvent for verification of the proposed experimental protocol. The surface tension of the aqueous NaOH solvent was altered using surfactant and antifoam. The effective contact angle increases with the increased value of the surface tension for flat stainless steel sheets. On the other hand, effective contact angles do not vary in Mellapak coupons for aqueous monoethanolamine (MEA) and NaOH solvent. In this case, surface textures and sheet design play a dominant role in the surface tension of solvents. Furthermore, CO 2 loading has a significant effect on the contact angle for Mellapak coupons. As expected, the contact angle decreases with the increasing temperature of CO 2 capture solvents (MEA, EEMPA). The effective contact angle measurement using the Wilhelmy plate method can provide more accurate and efficient solvents for characterizing the solvent-packing surface interactions. Subsequently, the present method enhances the accuracy of the prediction of the effective mass transfer area in carbon capture by solvent absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure of the surface microrelief of a droplet evaporating from a rough substrate as a possible cause of contact angle hysteresis

Based on the refraction images of a droplet evaporating on a rough substrate, we simultaneously observed the dynamics of its surface microrelief, contact angle, and contact line deformations along the entire perimeter of the contact line. This has led us conclude that the microrelief structure is directly related to the phenomenon of contact angle hysteresis and the jump-like pattern of contact line deformation. We suggest a possible mechanism for the occurrence of contact angle hysteresis during droplet evaporation and derive the relations that specify the range of possible contact angles at known microrelief parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice Boltzmann Modeling of Drying of Porous Media Considering Contact Angle Hysteresis

Drying of porous media is governed by a combination of evaporation and movement of the liquid phase within the porous structure. Contact angle hysteresis induced by surface roughness is shown to influence multi-phase flows, such as contact line motion of droplet, phase distribution during drainage and coffee ring formed after droplet drying in constant contact radius mode. However, the influence of contact angle hysteresis on liquid drying in porous media is still an unanswered question. Lattice Boltzmann model (LBM) is an advanced numerical approach increasingly used to study phase change problems including drying. In this paper, based on a geometric formulation scheme to prescribe contact angle, we implement a contact angle hysteresis model within the framework of a two-phase pseudopotential LBM. The capability and accuracy of prescribing and automatically measuring contact angles over a large range are tested and validated by simulating droplets sitting on flat and curved surfaces. Afterward, the proposed contact angle hysteresis model is validated by modeling droplet drying on flat and curved surfaces. Then, drying of two connected capillary tubes is studied, considering the influence of different contact angle hysteresis ranges on drying dynamics. Finally, the model is applied to study drying of a dual-porosity porous medium, where phase distribution and drying rate are compared with and without contact angle hysteresis. The proposed model is shown to be capable of dealing with different contact angle hysteresis ranges accurately and of capturing the physical mechanisms during drying in different porous media including flat and curved geometries.

36 MATERIALS SCIENCE↗

Correlation of Oil-Water and Air-Water Contact Angles of Diverse Silanized Surfaces and Relationship to Fluid Interfacial Tensions

The use of air-water, {Theta}{sub wa}, or air-liquid contact angles is customary in surface science, while oil-water contact angles {Theta}{sub ow}, are of paramount importance in subsurface multiphase flow phenomena including petroleum reocovery, nonaqueous phase liquid fate and transport, and geological carbon sequestration. In this paper we determine both the air-water and oil-water contact angles of silica surfaces modified with a diverse selection of silanes, using hexadecane as the oil. The silanes included alkylsilanes, alkylarylsilanes, and silanes with alkyl or aryl groups that are functionalized with heteroatoms such as N, O, and S. These silanes yielded surfaces with wettabilities from water-wet to oil wet, including specific silanized surfaces functionalized with heteroatoms that yield intermediate wet surfaces. The oil-water contact angles for clean and silanized surfaces, excluding one partially fluorinated surface, correlate linearly with air-water contact angles with a slope of 1.41 (R = 0.981, n = 13). These data were used to examine a previously untested theoretical treatment relating air-water and oil-water contact angles in terms of fluid interfacial energies. Plotting the cosines of these contact angles against one another, we obtain a linear relationship in excellent agreement with the theoretical treatment; the data fit cos {Theta}{sub ow} = 0.667 cos {Theta}{sub ow} + 0.384 (R = 0.981, n = 13), intercepting cos {Theta}{sub ow} = -1 at -0.284. The theoretical slope, based on the fluid interfacial tensions {Theta}{sub wa}, {Theta}{sub ow}, and {Theta}{sub oa}, is 0.67. We also demonstrate how silanes can be used to alter the wettability of the interior of a pore network micromodel device constructed in silicon/silica with a glass cover plate. Such micromodels are used to study multiphase flow phenomena. The contact angle of the resulting interior was determined in situ. An intermediate wet micromodel gave a contact angle in excellent agreement with that obtained on an open planar silica surface using the same silane.

02 PETROLEUM↗

Beyond-Cassie Mode of Wetting and Local Contact Angles of Droplets on Checkboard-Patterned Surfaces

Droplet wetting and distortion on flat surfaces with heterogeneous wettability are studied using the 3D Shan–Chen pseudopotential multiphase lattice Boltzmann model (LBM). The contact angles are compared with the Cassie mode, which predicts an apparent contact angle for flat surfaces with different wetting properties, where the droplet size is large compared to the size of the heterogeneity. The surface studied consists in a regular checkboard pattern with two different Young’s contact angles (hydrophilic and hydrophobic) and equal surface fraction. The droplet size and patch size of the checkboard are varied beyond the limit where Cassie’s equation is valid. A critical ratio of patch size to droplet radius is found below which the apparent contact angle follows the Cassie mode. Above the critical value, the droplet shape changes from a spherical cap to a more distorted form, and no single contact angle can be determined. The local contact angles are found to vary along the contact line between minimum and maximum values. The droplet is found to wet preferentially the hydrophilic region, and the wetted area fraction of the hydrophilic region increases quasi-linearly with the ratio between patch and droplet sizes. We propose a new equation beyond the critical ratio, defining an equivalent contact angle, where the wetted area fractions are used as weighting coefficients for the maximum and minimum local contact angles. This equivalent contact angle is found to equal Cassie’s contact angle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contact angles from Young’s equation in molecular dynamics simulations

In this work, we propose a method to calculate the equilibrium contact angle of heterogeneous 3-phase solid/fluid/fluid systems using molecular dynamics simulations. The proposed method, which combines the phantom-wall method [F. Leroy and F. Müller-Plathe, J. Chem. Phys. 133, 044110 (2010)] and Bennett’s acceptance ratio approach [C. H. Bennett, J. Comput. Phys. 22, 245 (1976)], is able to calculate the solid/fluid surface tension relative to the solid surface energy. The calculated relative surface tensions can then be used in Young’s equation to estimate the equilibrium contact angle. A fluid droplet is not needed for the proposed method, in contrast to the situation for direct simulations of contact angles. In addition, while prior free-energy based methods for contact angles mainly focused on the wetting of fluids in coexistence with their vapor on solid surfaces, the proposed approach was designed to study the contact angles of fluid mixtures on solid surfaces above the fluid saturation pressures. Using the proposed approach, the contact angles of binary Lennard-Jones fluid mixtures on a non-polar solid substrate were calculated at various interaction parameters and the contact angle of water in equilibrium with CO 2 on a hydrophilic polar silica surface was obtained. For both non-polar and polar systems, the calculated contact angles from the proposed method were in agreement with those obtained from the geometry of a cylindrical droplet. The computational cost of the proposed method was found to be comparable to that of simulations that use fluid droplets, but the new method provides a way to calculate the contact angle directly from Young’s equation without ambiguity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗