Understanding resistances in capacitive deionization devices
The desalination characteristics of capacitive deionization (CDI) are significantly impacted by the cell resistance. Here we apply electrochemical impedance spectroscopy (EIS) to analyze the resistive properties of a CDI device, which include EIS measurements on a complete assembled cell (in two wire mode) and EIS measurements with additional contacts to decouple electrode/electrolyte and contact impedances (four wire mode). These measurements shed light on the interface between current collector and electrode as well as the internal capacitive and resistive elements of the cell. With two-wire and four-wire EIS measurements, we find that the often observed high-frequency arc(s) in the impedance spectra can be due to contact effects and/or an internal ionic-transfer resistance that is locally in parallel with macropore wall capacitance. In some cases, the two associated arcs in the Nyquist plot are overlapping and present simultaneously, making their identification in the EIS spectra difficult unless both two-wire and four-wire measurements are made. Despite causing a large high-frequency arc in the Nyquist plot, we find that the apparent internal ionic-transfer resistance is negligible compared to the resistances of the electrode, separator, and external electronic components. Here, an investigation of the contact impedance between the electrode and current collector reveals a parallel RC arc that can grow over time if an improper material is used (e.g., titanium). In our system, the electrode ionic resistance dominates the total Ohmic power dissipation, which has implications for scale-up of CDI systems and future improvements of cell design.
An alternative electrode design for accurate spectral induced polarization measurements in variably saturated porous media
SUMMARY Applications of spectral induced polarization (SIP) require electrodes that maintain hydrologic contact with surrounding soils to capture small electrical responses, often observed as phase shifts in milliradians. For unsaturated soils, electrodes must overcome increased electrical contact impedance due to reduced pore fluid. Traditional designs use a ceramic membrane electrode (CME) with a water reservoir and metal conductor, requiring periodic maintenance to retain electrolytic solution. For field applications where maintenance is impractical, alternative designs are needed. This study evaluated a new electrode design (silica flour electrode, SFE) alongside a CME. SFEs use packed silica flour to store water via capillary forces against a metal conductor. This study examined both designs in three variably saturated soils at soil suctions up to 700 mbar and soil water contents below 1 percent, with SIP measurements across 0.01 to 10 000 Hz frequencies. SFEs match CMEs at high frequencies and perform better at lower frequencies, without requiring ongoing maintenance, making them ideal for field use. In water-only experiments, CMEs produced errors and high noise below 1.5 Hz, whereas SFEs were more accurate. However, CMEs performed better above 300 Hz. In fine sand, SFEs performed better due to the relatively lower contact impedance as compared to CMEs. Both electrode types performed comparably in silty sand and silt loam soils, although CMEs required ongoing maintenance, suggesting potential for long-term reliability issues.
An Ultra-Precise System for Electrical Resistivity Tomography Measurements
The objective of this research was to determine the feasibility of building and operating an ERT system that will allow measurement precision that is an order of magnitude better than existing systems on the market today and in particular if this can be done without significantly greater manufacturing or operating costs than existing commercial systems. Under this proposal, we performed an estimation of measurement errors in galvanic resistivity data that arise as a consequence of the type of electrode material used to make the measurements. In our laboratory, measurement errors for both magnitude and induced polarization (IP) were estimated using the reciprocity of data from an array of electrodes as might be used for electrical resistance tomography using 14 different metals as well as one non-metal - carbon. In a second phase of this study, using archival data from two long-term ERT surveys, we examined long-term survivability of electrodes over periods of several years. The survey sites were: the Drift Scale Test at Yucca Mountain, Nevada (which was sponsored by the U. S. Department of Energy as part of the civilian radioactive waste management program), and a water infiltration test at a site adjacent to the New Mexico Institute of Mines and Technology in Socorro, New Mexico (sponsored by the Sandia/Tech vadose program). This enabled us to compare recent values with historical values and determine electrode performance over the long-term as well as the percentage of electrodes that have failed entirely. We have constructed a prototype receiver system, made modifications and revised the receiver design. The revised prototype uses a new 24 bit analog to digital converter from Linear Technologies with amplifier chips from Texas Instruments. The input impedance of the system will be increased from 107 Ohms to approximately 1010 Ohms. The input noise level of the system has been decreased to approximately 10 Nanovolts and system resolution to about 1 Nanovolt at the highest gain range of 125 to 1. The receiver also uses very high precision and high temperature stability components. The goal is to improve the accuracy to better than 0.1%. The system has more receiver channels, eight, to allow efficient data collection at lower base frequencies. We are also implementing a frequency-domain acquisition mode in addition to the time-domain acquisition mode used in the earlier systems. Initial field tests were started in the fall of 2008. We conducted tests on a number of types of cable commonly used for resistivity surveys. A series of different tests were designed to determine if the couplings were primarily resistive, capacitive, or inductive in nature and to ascertain that the response was due to the cable cross-talk and did not depend on the receiver electronics. The results show that the problem appears to be primarily capacitive in nature and does not appear to be due to problems in the receiver electronics. Thus a great deal of emphasis has been placed on finding appropriate cables as well as stable electrodes that have low contact impedance at the very low current flows observed at the receiver. One of the issues in survey design and data collection has been determining how long one must wait before using the same electrode as a transmitter and as a receiver. A series of tests was completed in the laboratory sand tank where four-electrode measurements were made using the same dipole transmitters and dipole receivers (the dipoles used adjacent electrodes). For each data series, a single set of normal measurements were collected with no reciprocals and electrodes were never reused as a receiver after being used as a transmitter. After waiting a specified length of time, the reciprocal measurements were collected using a schedule of measurements. The order of this second schedule was rearranged such that if this second set of measurements were performed without first using the normal schedule, no electrode would be used as a receiver after being used as a transmitter. For this study, we cannot conclude that increasing the wait time increased or decreased the reciprocal errors, only that there was not a dramatic change in results with different wait times. Another issue in ERT data collection is the potential for the transmitter as well as the receiver end of an ERT system to create problems with reciprocity readings. Existing ERT systems typically use a constant voltage source. For the transmitter dipole, a constant voltage source has low output impedance, whereas a constant current source has high output impedance. Therefore, we devised an experiment to determine if a constant current source transmitter might produce smaller errors than a constant voltage source. These preliminary results suggest there is little or no difference in either resistivity or chargeability reciprocal errors using a constant voltage or constant current dipole drive source.
Estimation Of Charge Transport Parameters And Equivalent Circuit For Poly Alkyl Thiophene Field-Effect Transistors
The small signal ac response is measured across the source-drain terminals of organic field-effect transistors (OFET) under dc bias to obtain the equivalent circuit parameters of poly (2,5-bis(3-tetradecylthiophen-2-yl)thieno[3,2-b]thiophene)(PBTTT) and poly(3-hexyl thiophene)(P3HT) based devices. The numerically simulated response based on these parameters is in good agreement with the experimental data for PBTTT-FET except at low frequencies, while the P3HT-FET data show significant deviations. This indicates that the interface with the metal electrode is rather complex for the latter, involving additional circuit elements arising from contact impedance or charge injection processes. Such an investigation can help in identifying the operational bottlenecks and to improve the performance of OFETs.
Analytical modeling and simulation of electrical contact resistance for elastic rough electrode surface contact including frictional temperature rise
An improved electrical contact resistance (ECR) model for elastic rough electrode contact is proposed, incorporating the effects of asperity interactions and temperature rise by frictional and joule heating. The analytical simulation results show that the ECR decreases steeply at the beginning of the contact between Al and Cu. However, it becomes stabilized after reaching a specific contact force. It is also found that the longer elapsed sliding contact time, the higher ECR due to the increase in electrical resistivity of electrode materials by the frictional temperature rise at the interface. The effects of surface roughness parameters on ECR are studied through the 3 2 full-factorial design-of-experiment analysis. Based on the two representative roughness parameters, i.e., root-mean-square (rms) roughness and asperity radius, their individual and coupled effects on the saturated ECR are examined. The saturated ECR increases with the rms roughness for a rough machined surface condition, but it is hardly affected by the asperity radius. On the other hand, the saturated ECR increases with both the rms roughness and the asperity radius under a smooth thin film surface condition.
Extraction of intrinsic contact resistance in organic thin-film transistors with single channel length and high capacitance density
Accurate characterization of the intrinsic contact resistance is important for the optimization of organic thin-film transistors (OTFTs), especially in devices with high gate capacitance density. This study reports on a method for the extraction of the intrinsic, or gate-voltage independent, contact resistance from OTFTs. In contrast to the transfer length method (TLM), this method can be applied to devices with a single geometry. The method is an extension of the previously reported Y-function method and combines the model proposed by S. Luan et al. to analyze the effect of the gate voltage on the contact resistance. Here, this method is first applied to OTFTs with a bottom-gate top-contact geometry having varying gate capacitance density values. The intrinsic contact resistance is found to decrease with increased gate capacitance density with values ranging between 4 kΩcm and under 1 kΩcm when the gate capacitance is changed from 36.6 nF/cm 2 to 231.7 nF/cm 2 , respectively. These values are in good agreement with those obtained using TLM experiments. The new method is also shown to be applicable to OTFTs with top-gate bottom contact geometry.
A Multifunctional Double Pulse Tester for Cascode GaN Devices
Not provided.
High Fidelity Interface Modeling to Enable Enhanced Electromagnetics ModSim Capabilities
Years of work by 1350 and others has shown that the phenomenology behind EM penetration of joints and seams is a major driver in the shielding effectiveness of ND systems. Via analysis of a canonical cylindrical geometry and comparison against experimental data, we will provide evidence supporting the theory that proper treatment of contact phenomenology including joint deformation, asperity-induced contact impedance, and appropriate treatment of machining tolerance values is required to match electromagnetics modeling and simulation results to experimental data.
On the need for space tests of plasma contactors as electron collectors
An analysis is presented of laboratory experiments that have shown that hollow plasma sources can provide low-impedance contact with a background plasma. In particular, some experiments show an report an 'ignited mode' of electron collection using plasma sources where almost an ampere was collected at a potential of 100 volts. The experimental results are compared with theoretical and computational models of plasma layers. Preliminary results indicate that the measured potential profiles and collected currents during the 'ignited mode' correspond to an increase in the background plasma thermal current of more than an order of magnitude. The results imply that the 'ignited mode' results are substantially impacted by the laboratory electron source and the tank size. Only experiments performed in space will be able to provide the correct boundary conditions for reliably testing high electron collection by plasma contactors.
Double layers in contactor plasmas
The concept of using a hollow cathode to establish a low impedance contact between a spacecraft and the ambient plasma continues to gain in popularity, and is often then referred to as a plasma contactor. A growing number of studies indicate that large contact currents can be supported with small potential difference between the contactor and the ambient plasma. Results will be presented from a simple one-dimensional spherical model that obtains potentials from the solution of Poisson's equation, and particle densities from a turning point formalism that includes particle angular momentum. The neglect of collisions and magnetic field limits the realism. However, the results illustrate the effect of double layers that can form at the interface between contactor and ambient plasmas, when there is any voltage differential between the contactor and the ambient. The I-V characteristic of this model shows the usual space charge depends upon collection when the contactor flux is lower than some threshold; independence of I from variation in V when the flux is slightly greater than that threshold, and (numerical ?) instability for excessive flux suggesting the possibility of negative resistance. Even if a real I-V characteristic does not exhibit negative resistance, flat spots or high resistance regions may still be troublesome (or useful) to the total circuit.
GHz operation of a quantum point contact using stub-impedance matching circuit
Not Available
Measuring the Resistance and Impedance of the Welding Circuit in Contact Machines
Methods are proposed for measuring the resistance and impedance of the welding circuit in contact machines; the machine may be switched on in short-circuit mode. Methods are outlined for measuring and calculating the basic electrical parameters.
One-dimensional edge contact to encapsulated MoS 2 with a superconductor
Establishing ohmic contact to van der Waals semiconductors such as MoS 2 is crucial to unlocking their full potential in next-generation electronic devices. Encapsulation of few layer MoS 2 with hBN preserves the material’s electronic properties but makes electrical contacts more challenging. Progress toward high quality edge contact to encapsulated MoS 2 has been recently reported. Here, we evaluate a contact methodology using sputtered MoRe, a type II superconductor with a relatively high critical field and temperature commonly used to induce superconductivity in graphene. We find that the contact transparency is poor and that the devices do not support a measurable supercurrent down to 3 K, which has ramifications for future fabrication recipes.
Atomic layer etching (ALE) of III-nitrides
Atomic layer etching (ALE) was performed on (Al, In, Ga)N thin films using a cyclic process of alternating Cl 2 gas absorption and Ar + ion bombardment in an inductively coupled plasma etcher system. The etch damage was characterized by comparing photoluminescence of blue single quantum well light-emitting diodes before and after the etch as well as bulk resistivities of etched p-doped layers. It was found that etched surfaces were smooth and highly conformal, retaining the step-terrace features of the as-grown surface, thus realizing ALE. Longer exposures to the dry etching increased the bulk resistivity of etched surfaces layers slightly, with a damaged depth of ∼55 nm. With further optimization and damage recovery, ALE is a promising candidate for controlled etching with atomic accuracy. Finally, it was found that Al 0.1 Ga 0.9 N acts as an etch barrier for the ALE etch, making it a suitable etch to reveal buried V-defects in III-nitride light emitting diodes.
Bio-Inspired Energy-Efficient Nanofabricated Electrical Contacts
Nanoscale electrical contacts, especially those between materials of dissimilar electronic properties, often represent one of the main causes of drops in energy transfer efficiency. They are also among the sources of above-threshold noise, and their performance often decreases over the lifetime of the nanodevices. Scale-down limitations from mesoscopic to nanoscale devices, and likewise, of nanoscale to quantum-scale devices are also impeded by contacts’ quality. Making more reliable, energy-efficient electrical contacts is among the goals of the nanoelectronics research within the framework of energy-efficient electronic systems. This report focuses on the design, nanofabrication, and testing of novel shapes of electrical contacts. Lithography and nanofabrication were utilized to mimic the approximate shape of insect setae for mesoscale contacts design. The contacts are tested for elementary charge transport via I–V curves and for the broadband, 1/f noise. Tests show that contacts design leads to a measurable decrease in the energy necessary to operate a contact as a switch by at least 12–20%, depending on temperature, while broadband noise shows measurably lower power spectra, for bio-inspired contacts. The proposed method is open to modifications and improvements as required by various on-chip applications.
Noise processes in InAs/Ga(In)Sb Corbino structures
Two-dimensional topological insulators are of great interest, with predicted topological protection of one-dimensional helical edge states at their boundaries. Shot noise, the fluctuations in driven current due to the discreteness of charge carriers, has been proposed as a way of distinguishing between trivial and nontrivial edge state conduction, as well as a means of assessing back-scattering mechanisms in the latter. Such measurements require an understanding of possible contributions to the noise from contacts and conduction in the 2D bulk. We present noise measurements in Corbino structures based on InAs/Ga(In)Sb quantum well interfaces over a broad temperature and applied current range. As the temperature is lowered and the bulk transport is gapped out, shot noise becomes detectable in these two-terminal devices, in both high- and low-frequency measurement techniques. Quantitative comparison with a noise model shows that the total applied voltage drop is split among the contacts and the bulk and that the devices have some intrinsic asymmetry. Within that model, the magnitude of the shot noise appears to be anomalously large, implying the contacts to the 2D bulk are nontrivial in this system.
Passivation, conductivity, and selectivity in solar cell contacts: Concepts and simulations based on a unified partial-resistances framework
Passivation, conductivity, and selectivity are often acknowledged as the three requirements for optimal contacts to photovoltaic solar cells. Although there are generally accepted definitions and metrics for passivation and conductivity, a common understanding of the concept of selectivity is emerging only now. In this contribution, we present a generalized model of solar cell contacts based on the distinct lumped resistances encountered by electrons and holes traversing a contact, which we refer to as partial specific contact resistances. The relations between electron and hole partial current densities, quasi-Fermi level separation, and external voltage are derived from these partial specific contact resistances, leading to simple metrics for the aforementioned contact properties: the sum of the electron and hole resistances is a metric for passivation, their ratio is a metric for selectivity, and the majority-carrier resistance is a metric for conductivity. Using PC1D, we validate our model by simulating 10 500 cases of homojunction contacts to crystalline silicon solar cells, although our framework is material agnostic and can be equally applied to any other type of absorber. In these simulations, the hole contact and absorber are assumed to be ideal, whereas we vary the partial specific contact resistances in the electron contact by orders of magnitude by adjusting the electron and hole mobilities, their densities (through variations of the donor doping density), and the contact thickness. The simulations confirm the finding of the model that, when the contact fraction cannot be adjusted—as is the case with full-area contacts—combined passivation and conductivity are necessary and sufficient for optimal solar cell performance, and they imply selectivity. However, the reciprocal is not true: contacts can be selective but lack conductivity—causing a deleterious drop in fill factor—or can be selective but provide poor passivation—leading to a reduction in implied open-circuit voltage and, hence, actual open-circuit voltage. Furthermore, selectivity is a meaningful metric in the sole case of partial-area contacts, where the contact fraction can be adjusted arbitrarily.