Search NASA⌕ Search

SEARCH · Search NASA

Results for “Container System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Integrating PCTRAN with AI-Driven Host-Intrusion Detection and Secured Container Systems for Advanced Malware Analysis (Summer Internship Report)

This study presents a solution for enhancing the security of the Personal Computer Transient Analyzer (PCTRAN) PC-based Nuclear Power Plant Simulator by integrating the software with an artificial intelligence (AI)-driven host-intrusion detection system (HIDS), in addition to a secured container system, for malware analysis. PCTRAN is a Windows XP-based software package that has the ability to simulate a variety of accident and transient conditions for nuclear power plants (NPPs). It offers a high-resolution replica of the Nuclear Steam Supply System (NSSS) and displays the status of important parameters allowing for operator interaction. By including AI-driven HIDS for the NSSS, the framework can identify security threats in real-time, ensuring the integrity of the nuclear simulation environment. Additionally, the secured container system offers the ability to isolate and analyze malware, preventing potential threats from affecting core systems. The integration process involves extensive testing and validation in order to ensure accuracy, reliability, and compliance with security policies. This framework sets a new precedent for secure simulation and training in NPP operations, and offers insight for future advancements in cybersecurity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiolytic Gas Generation and Pressure Buildup in a Closed System Containing Mo-99 Solution

This study measured radiolytic gas generation and pressure buildup in a sealed stainless-steel system containing alkaline Mo-99 solution with added sodium nitrate as a hydrogen suppressant. In each of two experiments, approximately 200 Ci of Mo-99 solution was transferred into a closed experimental vessel inside a hot cell, isolated, and monitored for pressure rise caused by gas generation during radioactive decay. After pressure buildup, headspace gas samples were collected and analyzed by mass spectrometry to determine hydrogen and oxygen concentrations. The purpose was to quantify the magnitude of pressure buildup in a closed system and to characterize the gas composition produced by radiolysis of the Mo-99 target solution under representative handling and storage conditions. The two experiments used similar total Mo-99 activity but differed in solution volume, headspace volume, and leak integrity. In the first experiment, 197.5 Ci of Mo-99 in 16.92 mL of solution was loaded into a vessel with a 31.1-mL headspace; a small leak was later identified, and the measured peak pressure of 46 psig was extrapolated to about 70 psig in the absence of leakage. The headspace gas from this experiment contained about 21.4% H2 and 63.4% O2, but the composition was influenced by preferential hydrogen loss through the leak. In the second experiment, 193 Ci of Mo-99 in 5.41 mL of solution with 0.46 g NaNO3 was loaded into a vessel with a larger 42.61 mL headspace, and no detectable leak was observed. This experiment reached a peak pressure of 38 psig, and the measured gas composition was approximately 28.2% H2 and 51.5% O2. Because the second experiment was leak-free, it is considered the more reliable indicator of the true pressure buildup and intrinsic radiolytic gas composition of the Mo-99 solution.

Chemerisov, Sergey D.↗

Intubation Containment System for Improved Protection From Aerosolized Particles During Airway Management

Worldwide efforts to protect front line providers performing endotracheal intubation during the COVID-19 pandemic have led to innovative devices. Authors evaluated the aerosol containment effectiveness of a novel intubation aerosol containment system (IACS) compared with a recently promoted intubation box and no protective barrier. In a simulation center at the authors’ university, the IACS was compared to no protective barrier and an intubation box. Aerosolization was simulated using a commercial fog machine and leakage of aerosolize mist was visually assessed. The IACS appeared to contain the aerosolized mist, while the intubation box allowed for mist to contact the laryngoscopist and contaminate the clinical space through arm port holes and the open caudal end. Both devices protected the laryngoscopist better than no protective barrier. The IACS with integrated sleeves and plastic drape appears to offer superior protection for the laryngoscopist and assistant providers from aerosolized particles.

aerosols↗

Pilot-pressure-controlled flow valve and fluid system containing same

In a thermal fluid system, a control valve includes a flow valve and a solenoid pilot valve. The flow valve has an inlet and an outlet; a control chamber for receiving a pilot pressure; and a valve member operable by the pilot pressure to selectively open and close a fluid path from the inlet to the outlet. The pilot pressure acts in a closing direction of the flow valve. The pilot valve provides the pilot pressure to the control chamber and is a 3/2 way valve with a first port in fluid communication with the control chamber, a second port to be connected to a pressure source, and a third port. The pilot valve has a first position connecting the first port with the second port and a second position connecting the first port with the third port.

Chowdhury, Sourav↗

Analysis and Thermal Property Investigations into Ternary Actinide Chloride Salt Systems Containing UCl3 and PuCl3

While regulators, the scientific community, and MSR developers still lack access to literature data on the thermal properties of clean fuel salts, even less information is available on the properties of fuel salts containing impurities. It is essential to understand, benchmark, and predict crucial data on the changes in thermal properties of fuel salt systems due to impurities arising from moisture, corrosion, and reactor operation (i.e., fission products). This research focuses on two actinide fuel salts (1) to investigate a worst-case scenario buildup of actinide fission product in a NaCl-UCl3 eutectic fuel salt and (2) to investigate NaCl-PuCl3 eutectic salt after 1000 hours of operation in a natural circulation flow loop flow to determine if corrosion or atmospheric (moisture/oxygen) products are present. For the first salt, a conservative assumption or worst-case scenario, for fission product buildup in a fuel salt was investigated by adding PuCl3 to eutectic 67 mol% NaCl – 33 mol% UCl3 salt resulting in a ternary salt having a composition of 61 mol% NaCl – 30 mol% UCl3 – 9mol% PuCl3. Addition of PuCl3 to eutectic NaCl-UCl3 resulted in a ternary salt that had a higher melting temperature than either the NaCl-PuCl3 or NaCl-UCl3 binary eutectic mixture. Addition of PuCl3 also resulted in an increase in density which was expected. The second salt was extracted from a micro loop. The composition of the fuel (primary) salt prior to flow loop operations was determined to be 64 mol% NaCl – 36 mol% PuCl3, however, the post-flow loop salt showed increased levels of MgCl2 and NaCl changing the salt composition to 10 mol% MgCl2 – 63mol% NaCl – 26mol% PuCl3) indicating the primary salt interacted with the rinse salt. Analysis of the post flow loop salt detected low concentrations of Al, Ni, Co, Nb, and Zr, most likely corrosion products from the flow loop material of construction. Contamination of the fuel salt (with the rinse salt NaCl-MgCl2) decreased the density by approximately 10% and reduced the onset of melting temperature by 50 °C, from 451 °C to approximately 400 °C. Results from the fission product simulated salt (61 mol% NaCl – 30 mol% UCl3 – 9mol% PuCl3) and the corrosion product salt (10 mol% MgCl2 – 63mol% NaCl – 26mol% PuCl3) will be included in two separate manuscripts for submission to peer-reviewed journals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Historic Context and Mitigation Documentation for a Portion of the U12n Tunnel Ventilation and Containment Systems, Area 12, Nevada National Security Site, Nye County, Nevada

The National Nuclear Security Administration Nevada Field Office (NNSA/NFO) has proposed repurposing the U12n Vent Hole #2 (SHPO Resource S2488) and the U12n.10 Vent Hole (S2489) for water sampling in the U12n Tunnel. The vent holes are part of the historic ventilation system for the tunnel and are contributing elements to the U12n Tunnel Historic District (D84). In consultation with the SHPO, NNSA/NFO determined the undertaking will have an adverse effect on the vent holes. The NNSA/NFO and the SHPO negotiated a memorandum of (MOA) with stipulations to mitigate adverse effects. This submission is to comply with the stipulations in the executed Memorandum of Agreement Between the National Nuclear Security Administration Nevada Field Office, Environmental Management Nevada Program Office, and the Nevada State Historic Preservation Officer Regarding Repurposing of Portions of the Ventilation System of the U12n Tunnel Complex Located in Area 12 at the Nevada National Security Site. In accordance with the MOA, the manuscript provides a historic context that describes the development and functioning of the historic U12n Tunnel ventilation system for underground nuclear tests (Stipulation III.C). High resolution digital color images of the vent hole containment doors, nearby elements, and overviews were obtained and keyed to a map and a photo index (Stipulation III.A) (Appendix A). Lastly, Architectural Resource Assessment (ARA) forms were completed for each of the vent holes and Historic District D84 (Stipulation III.B) (Appendix B). The documentation including the historic context report, photographs, image files, and resource forms produced to fulfill the terms of the MOA will be archived with the Nuclear Testing Archive in Las Vegas (Stipulation III.D).

54 ENVIRONMENTAL SCIENCES↗

A new hypothesis for air loss in cement systems containing fly ash

Although there are many benefits gained from incorporating fly ash into concrete, carbon contamination in the fly ash has been shown to interfere with the efficacy of organic additives in an unpredictable manner. This work uses surface tension measurements to quantify the adsorption of air-entraining agents (AEA) onto cement and fly ash. Both the adsorption capacity of the adsorbents and the adsorption isotherms indicate that the fly ash particles, rather than the carbon itself, dominate adsorption in a carbon-contaminated ash in cement pore solution. We propose that adsorption onto fly ash particles and cement actually improve air entrainment via Pickering stabilization. While the carbon is still expected to contribute to air loss via hydrophobic adsorption of the surfactants, we suggest that the primary way in which the carbon interferes is by shielding surfactant-coated fly ash particles from participating in air development and Pickering stabilization during mixing.

36 MATERIALS SCIENCE↗

A reactive molecular dynamics model for uranium/hydrogen containing systems

Uranium-based materials are valuable assets in the energy, medical, and military industries. However, understanding their sensitivity to hydrogen embrittlement is particularly challenging due to the toxicity of uranium and the computationally expensive nature of quantum-based methods generally required to study such processes. In this regard, we have developed a Chebyshev Interaction Model for Efficient Simulation (ChIMES) that can be employed to compute energies and forces of U and UH3 bulk structures with vacancies and hydrogen interstitials with accuracy similar to that of Density Functional Theory (DFT) while yielding linear scaling and orders of magnitude improvement in computational efficiency. Here, we show that the bulk structural parameters, uranium and hydrogen vacancy formation energies, and diffusion barriers predicted by the ChIMES potential are in strong agreement with the reference DFT data. We then use ChIMES to conduct molecular dynamics simulations of the temperature-dependent diffusion of a hydrogen interstitial and determine the corresponding diffusion activation energy. Our model has particular significance in studies of actinides and other high-Z materials, where there is a strong need for computationally efficient methods to bridge length and time scales between experiments and quantum theory.

36 MATERIALS SCIENCE↗

Combinatorial investigation of the Mn–Ge–N chemical system containing ternary nitrides Mn 3 GeN and MnGeN 2

By changing nitrogen chemical potential during synthesis of Mn–Ge–N ternary nitrides, both wurtzite MnGeN 2 and antiperovskite Mn 3 GeN ternary phases are prepared. Antiperovskite films are optically opaque and conductive, while wurtzite films with Mn/(Mn + Ge) ≤ 0.5 transmit light above ~ 2 eV. Alloys of Mn 3 GeN with Si and Al are also investigated. Mn 3 (Ge 1−x Al x )N alloys with 0.07 ≤ x ≤ 0.16 exhibit a cubic (rather than tetragonal) structure. Mn 3 (Ge 1−x Si x )N with x ≤ 0.05 maintains the tetragonal structure but becomes cubic when x > 0.05. This study shows that care must be taken in the synthesis of Mn–Ge–N and similar nitrides, especially when materials are integrated into devices not amenable to structural and chemical probing.

36 MATERIALS SCIENCE↗

RFA-17-14597, Methodology for Meeting Containment System Principal Design Criteria to Maximize the Passive Safety Value in Advanced Nuclear Energy Economic Competitiveness

Advanced (Non-Light Water) Reactors are being designed with Passive Safety as an essential and integral feature. To help streamline the licensing of advanced reactors, the DOE and the NRC have drafted Principal Design Criteria (PDCs) for advanced reactors. A question that remains to be answered is: how an Advanced Reactor take credit for passive safety features inherent in certain advanced reactors while at the same time complying the evolving PDC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Process to produce 5-hydroxymethylfurfural (HMF) from carbohydrates using a solvent system containing water and a polar aprotic solvent

A method to produce 5-hydroxymethylfurfural (HMF) from C6 carbohydrates. The method includes the steps of reacting a reactant comprising at least one C6 carbohydrate, in a reaction mixture comprising at least about 5% (v/v) water, a polar, aprotic solvent, and an acid, for a time, at a temperature, and at a hydrogen ion concentration wherein at least a portion of the C6 carbohydrate present in the reactant is converted to 5-hydroxymethyl furfural (“HMF”).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Stretchable electronic systems with containment chambers

The present invention provides electronic systems, including device arrays, comprising functional device(s) and/or device component(s) at least partially enclosed via one or more containment chambers, such that the device(s) and/or device component(s) are at least partially, and optionally entirely, immersed in a containment fluid. Useful containment fluids for use in containment chambers of electronic devices of the invention include lubricants, electrolytes and/or electronically resistive fluids. In some embodiments, for example, electronic systems of the invention comprise one or more electronic devices and/or device components provided in free-standing and/or tethered configurations that decouple forces originating upon deformation, stretching or compression of a supporting substrate from the free standing or tethered device or device component.

Rogers, John A.↗

Evaluating integration and performance of containerized climate applications on a Hewlett Packard Enterprise Cray system

Containers have taken over large swaths of cloud computing as the most convenient way of packaging and deploying applications. The features that containers offer for packaging and deploying applications translate to high performance computing (HPC) as well. At The National Oceanic and Atmospheric Administration, containers provide an easy way to build and distribute complex HPC applications, allowing faster collaboration, portability, and experiment computer environment reproducibility amongst the scientific community. The challenge arises when applications rely on message passing interface (MPI). This necessitates investigation into how to properly run these applications with their own unique requirements and produce performance on par with native runs. We investigate the MPI performance for benchmarks and containerized climate models for various containers covering selection of compiler and MPI library combinations from the Cray provided programming environments on the Cray XC supercomputer GAEA. Performance from the benchmarks and the climate models shows that for the most part containerized applications perform on par with the natively built applications when the system optimized Cray MPICH libraries are bound into the container, and the hybrid model containers have poor performance in comparison. We also describe several challenges and our solutions in running these containers, particularly challenges with heterogeneous jobs for the containerized model runs.

Abraham, Subil↗

A Complex Brownfields Case Study—The Former Bannister Federal Complex, Kansas City, Missouri

Abstract In November 2017, 225 acres (91 ha) of the former Bannister Federal Complex (BFC) in Kansas City, Missouri were transferred from the Federal Government to Bannister Transformation & Development, LLC (BTD), for demolition; environmental corrective measures; and preparation of the site for redevelopment. This presented a once‐in‐a‐lifetime opportunity to reconfigure groundwater remedies and address long‐standing soil contamination issues. The property included more than 40 previously‐identified Solid Waste Management Units, 3.9 million square feet (362,000 m 2 ) of buildings, subsurface utilities dating back to the 1940s, and an active groundwater containment system. Demolition of buildings and installation of an interim groundwater containment system began almost immediately after property transfer. In 2018, BTD substantially modified its project schedule to incorporate the construction of the first new buildings while demolition and remedial activities were ongoing. By October 2020, construction of the first new warehouse commenced while excavation and capping of contaminated soils, installation of a groundwater containment treatment systems, and abandonment of legacy utilities were still underway. Completion of this work, within the originally planned timeframe, was made possible by factors including up‐front multi‐year funding, early and ongoing engagement of regulators, an extended 3‐year due diligence program and planning stage, and establishment of well‐defined environmental targets. Both the soil and groundwater remedies were also designed with the flexibility needed to accommodate unknown conditions, changing schedules, and revisions to the regrading and redevelopment plans. This case study highlights key technical and management factors that led to the successful completion of this complex brownfields remediation project.

Water Resources↗

Development of an Innovative Inspection Tool for Superheater Tubes in Fossil Fuel Power Plants

Fossil fuel power plants are complex systems containing multiple components that require periodic health monitoring. Failures in these systems can lead to increased downtime for the plant, reduction of power, and significant cost for repairs. Inspections of the plant’s superheater tubes are typically manual, laborious, and extremely time-consuming. This is due to their small diameter size (between 1.3 and 7.6 cm) and the coiled structure of the tubing. In addition, the tubes are often stacked close to each other, limiting access for external inspection. This paper presents the development and testing of an electrically powered pipe crawler that can navigate inside 5 cm diameter tubes and provide an assessment of their health. The crawler utilizes peristaltic motion within the tubes via interconnected modules for gripping and extending. The modular nature of the system allows it to traverse through straight sections and multiple 90° and 180° bends. Additional modules in the system include an ultrasonic sensor for tube thickness measurements, as well as environmental sensors, a light detecting and ranging (LiDAR) sensor, and camera. Furthermore, these modules utilize a gear system that allows for 360° rotation and provides a means to inspect the entire internal circumference of the tubes.

36 MATERIALS SCIENCE↗

Unraveling the structural stability and the electronic structure of ThO 2 clusters

Unraveling the correlations between the geometry, the relative energy and the electronic structure of metal oxide nanostructures is crucial for a better control of their size, shape and properties. Here, we investigated these correlations for stoichiometric thorium dioxide clusters ranging from ThO 2 to Th 8 O 16 using a chemically-driven geometry search algorithm in combination with state-of-the-art first principles calculations. This strategy allows us to homogeneously screen the potential energy surface of actinide oxide clusters for the first time. It is found that the presence of peroxo and superoxo groups tends to increase the total energy of the system by at least 3.5 eV and 7 eV, respectively. For the larger clusters, the presence of terminal oxygen atoms increases the energy by about 0.5 eV. Regarding the electronic structure, it is found that the HOMO–LUMO gap is larger in systems containing only bridging oxygen atoms (~2–3.5 eV) than for systems containing oxo groups (~1–3 eV), peroxo groups (~0–2 eV), and superoxo groups (~0–1 eV). Furthermore, while the LUMO is always dominated by thorium orbitals, the composition of the HOMO changes in the presence or the absence of oxo, peroxo and/or superoxo groups: in the presence of peroxo groups, it is dominated by thorium orbitals, in all other cases, it is dominated by oxygen orbitals, and is rather localized in the presence of terminal oxo or superoxo groups. These correlations are of great interest for synthesizing clusters with tailored properties, especially for applications in the field of nuclear energy and heterogeneous catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗