Investigation of the explosion hazard of contaminated diffusion pump fluids Final report, 1 Jul. 1965 - 1 Jun. 1966
Effect of fluid contaminants on explosion hazard potential of space simulation type diffusion pumps
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Effect of fluid contaminants on explosion hazard potential of space simulation type diffusion pumps
The manner in which a trace contaminant diffuses through an accretion disk is calculated. For a steady disk in which the ratio of diffusivity to viscosity, zeta, is taken to be constant through the disk and for which the surface density distribution is taken to be a power law, analytic solutions to the time-dependent equations governing contaminant evolution are presented. The amount of contaminant which can diffuse its way outwards against the bulk inward accretion flow is calculated, and it is shown that this is a sensitive function of a and zeta.
Contamination on bonding surfaces has been determined to be a primary cause for degraded bond strength in certain solid rocket motor bondlines. Hydrocarbon and silicone based organic contaminants that are airborne or directly introduced to a surface are a significant source of contamination. Diffuse infrared (IR) reflectance has historically been used as an effective technique for detection of organic contaminants, however, common laboratory methods involving the use of a Fourier transform IR spectrometer (FTIR) are impractical for inspecting the large bonding surface areas found on solid rocket motors. Optical methods involving the use of acousto-optic tunable filters and fixed bandpass optical filters are recommended for increased data acquisition speed. Testing and signal analysis methods are presented which provide for simultaneous measurement of contamination concentration and roughness level on rough metal surfaces contaminated with hydrocarbons.
The complex problem of why large space simulation chambers do not realize true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance were identified, and some advances in vacuum distillation-fractionation technology were achieved which resulted in a two-decade-or-more lower ultimate pressure. Data are presented to show the overall or individual contaminating effects of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and for reclaiming contaminated oil by high-vacuum molecular distillation are described. Conceptual self-cleansing designs and operating procedures are proposed for modifying large diffusion pumps into high-efficiency distillation devices. The potential exists for application of these technological advancements to other disciplines, such as medicine, biomedical materials, metallurgy, refining, and chemical (diffusion-enrichment) processing.
The complex problem why large space simulation chambers do not realize the true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance have been identified and some advances in vacuum/distillation/fractionation technology have been achieved which resulted in a two decade or more lower ultimate pressure. Data are presented to show the overall or individual contaminating effect of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and reclaiming contaminated oil by high vacuum molecular distillation are described.
Not Available
Contaminants in the deep vadose zone (DVZ) pose a long-term threat to groundwater, human health, and the environment. Polyurethane grouting is a type of chemical grouting that is potentially advantageous in immobilizing contaminants in DVZs. Polyurethane resin has low viscosity that makes it feasible to penetrate and fill the pore space between fine particles. Here, in this study a series of laboratory pressure grouting and leaching tests were conducted to simulate and assess the effectiveness of polyurethane grouting for immobilizing contaminants in DVZs. Soil with fine particles was prepared with 127 I (as iodide) that served as a non-radioactive surrogate for radioactive 129 I. After grouting and curing, leaching tests were used to measure and compare contaminant diffusivity and leachability index values. Additionally, changes in porosity and saturated hydraulic conductivity of grouted soil were measured. X-Ray Computer Tomography (XCT) results showed that the cured polyurethane was distributed nearly homogeneously and approximately half of the voids were filled with cured polyurethane. Grouting reduced the saturated hydraulic conductivity of soil by 37 %. The effective diffusivity decreased by more than 80 % as compared with the ungrouted soil. The leachability index of the grouted soil was 6.5; meeting the criteria established by the U.S. Nuclear Regulatory Commission (NRC) standard. The results obtained in this study provide a valuable assessment of polyurethane grouting for iodide immobilization in the DVZ and indicate this approach may be a viable method for contaminant remediation in DVZ soils.
High vacuum centrifugal molecular distillation system rapidly reclaims contaminated diffusion pump oil in continuous operation and restores it to high level of purity.
The science objectives of increasingly ambitious space missions require meeting stringent contamination requirements. Contamination transport models are based on established principles such as Fick’s law for contamination diffusion within the source material, Arrhenius factors to account for temperature variations and free molecular transport for spacecraft operating in vacuum. In addition to the science principles, empirical data obtained from ASTM E1559 testing is used for engineering contamination modeling. The ASTM E1559 test provides outgassing rate data for materials at expected spacecraft temperatures during a mission. Multiple quartz crystal microbalances (QCMs) can be operated at different temperatures to measure the amount of contamination condensation that can occur on various spacecraft surfaces. At the conclusion of the ASTM E1559 test a thermo-gravimetric assessment (TGA) can be performed by heating the QCMs at a linear rate to obtain contamination desorption data. This TGA data provides a wealth of information that can be incorporated into contamination models. A method for applying this data is presented.
Membrane-based air-to-air energy exchangers (M–AAEEs) transfer heat and moisture between building exhaust air and fresh ventilation air streams through a membrane, thereby reducing the energy required for conditioning the fresh ventilation air. Energy exchangers are typically used in buildings with relatively clean building exhaust air, such as office buildings and schools. Recently interest in using energy exchangers in a wider range of buildings has grown, to reduce the energy consumption associated with the heating, ventilating, and air-conditioning (HVAC) systems in these buildings. However, if the building exhaust air is not clean, as would be the case for laboratories or factories, new risks are encountered when using energy exchangers. It is possible that gaseous contaminants in the exhaust air may also transfer along with the moisture through the membranes, contaminating the incoming fresh ventilation air. Current test standards provide a test procedure to determine the contamination of the fresh ventilation air by measuring the transfer of an inert tracer gas in an energy exchanger. However, the tracer gas test may not represent the transfer of common indoor air contaminants due to differences in their transport properties. Therefore, in this study, an experimental facility is developed to determine the transfer of seven different contaminants through two membranes (porous and dense) at different flow rates. Contaminant transfer is quantified using a parameter called the exhaust contaminant transfer ratio (ECTR), which gives the fraction of the contaminants transferred from the exhaust air to the fresh ventilation air. A theoretical model based on the effectiveness-number of transfer units (ε-NTU) correlation and moisture transfer resistance of the membrane is presented to determine transfer through porous membranes and validated with experimental results. The major contribution of this paper is that it presents a simple method to predict the transfer of different contaminants through a porous membrane based on the moisture transfer resistance of the membrane at different operating conditions. It is found that as contaminant diffusivity decreases, ECTR generally also decreases, and as the flow rate increases, ECTR decreases, which is consistent with the predictions from the correlation.
Sediments in aquatic systems often act as a major sink for contaminants. Diffusive gradient in thin films (DGTs) and in situ equilibrium dialysis samplers (peepers) are two major in situ pore water sampling devices that overcome the problems associated with conventional pore water sampling methods. In the present study, DGTs and peepers were used to study the spatial and seasonal effects (cool months, October–February; warm months, May–September) on metal bioavailability in the H‐02 constructed wetland and the sink versus source role of the sediments by calculating the metal resupply capacity. Data showed similar seasonal trends in metal concentrations using passive samplers, peepers, and DGTs. Pooled Cu and Zn concentrations measured using DGTs were lower in warm months (1.67 ± 1.50 and 2.62 ± 0.68 μg L –1 , respectively, p < 0.001) versus in cool months (2.12 ± 0.65 and 5.58 ± 1.33 μg L –1 , respectively, p < 0.001; mean ± 95% confidence interval). Sulfate (SO 4 2− ) concentrations were significantly (p = 0.0139) lower in warm months (averaged at 0.22 ± 0.05 mg L –1 ) compared to in cool months (0.16 ± 0.05 mg L –1 ). The increase in SO 4 2− concentration is an indicator of the lower activity of sulfate‐reducing bacteria, which need SO 4 2− during anaerobic respiration, in which SO 4 2− is reduced to sulfide (S 2– ) that forms insoluble salts with Cu and Zn, which could partially explain the higher bioavailability of these metals in the cool season. Metal resupply capacity of the sediments was mostly <0.2 for Cu and Zn. Taken together, the H0‐2 wetland sediments mostly acted as a sink to both Cu and Zn over the course of the present study. Environ Toxicol Chem 2023;42:2726–2736. © 2023 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals LLC on behalf of SETAC.
Polymer electrolyte membrane fuel cells provide an alternative option to fossil fuel-based energy conversion devices. However, the corrosion of fuel cell components, specifically the bipolar plates, introduces contaminants (e.g., Fe, Ni) into the membrane electrode assembly (MEA). These contaminants accelerate the ionomer degradation by acting as a Fenton’s reagent, decreasing the fuel cell’s durability. This study presents the mechanism and the diffusion media properties affecting the transport of cation contaminants into the MEA. Cation contaminant transport was studied after altering the gas diffusion layers (GDLs) wettability, emulating the GDL properties after prolonged operation, by ex situ hydrogen peroxide treatment or in situ electrochemical potential cycling. A GDL with crack-free microporous layer (MPL) showed a lower cation transport rate to the catalyst layer than MPL with cracks after both ex situ and in situ treatment. A novel GDL was developed from modification of the conventional GDL via the addition of a hydrophobic layer to the GDL substrate, which suppressed the contaminant cation transport significantly. This novel GDL also showed improved fuel cell performance.
Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)
A detailed chemical analysis was carried out on Spectralon, a highly Lambertian, diffuse reflectance material. Results of this investigation unambiguously identified the presence of an organic (hydrocarbon) impurity intrinsic to the commercial material. This impurity could be removed by a vacuum bake-out procedure and was identified as the cause of optical changes (degradation) that occur in the material when exposed to UV light. It was found that when this impurity was removed, the Spectralon material was photochemically stable and maintained its reflectance properties even after extensive solar UV exposure.
The blowoff/restore characteristics for jets of various H2/N2 mixtures opposed to jets of air contaminated by N2, CO, and CO2 have been determined using a counterflow diffusion flame formed by a tubular opposed jet burner. Both blowoff and restore limits are found to be sensitive to fuel and air composition. Empirically derived variations in the limits of the average mass flux of incoming H2 with percent contaminant, at fixed incoming fuel and H2/O2 inputs, are used to quantify the effects of oxygen dilution, flame augmentation, and flame retardation by N2, CO, and CO2 contaminants. The implications of the results are discussed.
This research was to advance the understanding of diffusion mechanisms in liquid metals and alloys through accurate diffusivity measurements over a wide range of temperatures, including the proximity of the materials melting points. Specifically, it was driven towards developing a methodology (and subsequent flight hardware) to enable several diffusion coefficient measurements (i.e., at several different temperatures) to be performed using a single sample. The Liquid Metal Diffusion (LMD) was funded as a Flight Definition Project in February 1993 in response to NRA 91-OSSA-20 (Microgravity Science and Applications Division). The Science Concept Review for LAID was held during April 1994. In January 1995 we were informed that we had failed this review and the project was change to ground-based activities only. A new proposal was submitted for the next NRA addressing the panels concerns. As part of NASA's Risk Mitigation program, a scaled-down version of the hardware was funded in July of 1995 for a flight opportunity utilizing experiment on the Microgravity Isolation Mount. This experiment was to determine the self-diffusivity of indium at 185 C. The LMD was transferred to the Mir Space Station in STS-81 and returned on STS-84 (January - May 1997). Three, out of five, self-diffusion data sets were returned. A description of this experiment/hardware is included below. This summary is only intended to give the reader an overview of the results obtained for the tasks outlined in the original proposal. Research that was not published is explained in more detail. At the end of this report is a list of refereed publications and invited talks that were given as a result of this work. The reader is directed to these for further details. Attachment: Real-time diffusivity measurements in liquids at several temperatures with one sample, On the insensitivity of liquid diffusivity measurements to deviations from 1D transport, and Numerical simulations of the convective contamination of diffusivity measurements in liquids.
We present the angular power spectrum derived from the first-year Wilkinson Microwave Anisotropy Probe (WMAP) sky maps. We study a variety of power spectrum estimation methods and data combinations and demonstrate that the results are robust. The data are modestly contaminated by diffuse Galactic foreground emission, but we show that a simple Galactic template model is sufficient to remove the signal. Point sources produce a modest contamination in the low frequency data. After masking approximately 700 known bright sources from the maps, we estimate residual sources contribute approximately 3500 mu sq Kappa at 41 GHz, and approximately 130 mu sq Kappa at 94 GHz, to the power spectrum [iota(iota + 1)C(sub iota)/2pi] at iota = 1000. Systematic errors are negligible compared to the (modest) level of foreground emission. Our best estimate of the power spectrum is derived from 28 cross-power spectra of statistically independent channels. The final spectrum is essentially independent of the noise properties of an individual radiometer. The resulting spectrum provides a definitive measurement of the CMB power spectrum, with uncertainties limited by cosmic variance, up to iota approximately 350. The spectrum clearly exhibits a first acoustic peak at iota = 220 and a second acoustic peak at iota approximately 540, and it provides strong support for adiabatic initial conditions. Researchers have analyzed the CT(sup Epsilon) power spectrum, and present evidence for a relatively high optical depth, and an early period of cosmic reionization. Among other things, this implies that the temperature power spectrum has been suppressed by approximately 30% on degree angular scales, due to secondary scattering.
The capability of molecular beam scattering from a solid surface is analyzed for identification of molecular contamination of the surface. The design and setup of the molecular beam source and the measuring setup for the application of a phase sensitive measuring technique for the determination of the scattered beam intensity are described. The scattering distributions of helium and nitrogen molecular beams interacting with a platinum surface were measured for different amounts of contamination from diffusion pump oil for surface temperatures ranging from 30 to 400 C. The results indicate the scattering of molecular beams from a platinum surface is a very sensitive method for detecting surface contamination.