JPL Contamination Control Engineering

JPL has extensive expertise fielding contamination sensitive missions-in house and with our NASA/industry/academic partners.t Development and implementation of performance-driven cleanliness requirements for a wide range missions and payloads - UV-Vis-IR: GALEX, Dawn, Juno, WFPC-II, AIRS, TES, et al - Propulsion, thermal control, robotic sample acquisition systems. Contamination control engineering across the mission life cycle: - System and payload requirements derivation, analysis, and contamination control implementation plans - Hardware Design, Risk trades, Requirements V-V - Assembly, Integration & Test planning and implementation - Launch site operations and launch vehicle/payload integration - Flight ops center dot Personnel on staff have expertise with space materials development and flight experiments. JPL has capabilities and expertise to successfully address contamination issues presented by space and habitable environments. JPL has extensive experience fielding and managing contamination sensitive missions. Excellent working relationship with the aerospace contamination control engineering community/.

Molecular Contamination Spectral Effects (MCSE) Ch

Contamination control engineering design guidelines for the aerospace community

Thermal control surfaces, solar arrays, and optical devices may be adversely affected by a small quantity of molecular and/or particulate contamination. What is rarely discussed is how one: (1) quantifies the level of contamination that must be maintained in order for the system to function properly, and (2) enforces contamination control to ensure compliance with requirements. This document is designed to address these specific issues and is intended to serve as a handbook on contamination control for the reader, illustrating process and methodology while providing direction to more detailed references when needed. The effects of molecular contamination on reflecting and transmitting surfaces are examined and quantified in accordance with MIL STD 1246C. The generation, transportation, and deposition of molecular contamination is reviewed and specific examples are worked to illustrate the process a design engineer can use to estimate end of life cleanliness levels required by solar arrays, thermal control surfaces, and optical surfaces. A similar process is used to describe the effect of particulate contamination as related to percent area coverage (PAC) and bi-directional reflectance distribution function (BRDF). Relationships between PAC and surface cleanliness, which include the effects of submicron sized particles, are developed and BRDF is related to specific sensor design parameters such as Point Source Transmittance (PST). The pros and cons of various methods of preventing, monitoring, and cleaning surfaces are examined and discussed.

Tribble, A. C.

Micro Raman Spectroscopy for Characterizing Molecular Contamination on Space Flight Hardware

In the field of contamination control,many unknowns exist. Often, contamination control engineers have to utilize multiple spectroscopic, macroscopic, and microscopic tools to identify contamination sources when there is a potential contamination exposure to space flight hardware. Understanding the chemical composition of the molecular contamination provides an opportunity for contamination control engineers to determine if this contamination is problematic or benign. In this study, an existing witness plate program for monitoring space flight hardware during the assembly, integration, and testing phases is coupled with micro Raman spectroscopy analysis. The main goal of this study is to determine the limitations, reproducibility, and throughput of micro Raman spectroscopy for characterizing molecular contamination. Micro Raman Spectroscopy will be an additional tool used by contamination control engineers to monitor the cleanliness of space flight hardware.

Microscope

Contamination Sources Effects Analysis (CSEA) - A Tool to Balance Cost/Schedule While Managing Facility Availability

A CSEA is similar to a Failure Modes Effects Analysis (FMEA). A CSEA tracks risk, deterrence, and occurrence of sources of contamination and their mitigation plans. Documentation is provided spanning mechanical and electrical assembly, precision cleaning, thermal vacuum bake-out, and thermal vacuum testing. These facilities all may play a role in contamination budgeting and reduction ultimately affecting test and flight. With a CSEA, visibility can be given to availability of these facilities, test sequencing and trade-offs. A cross-functional team including specialty engineering, contamination control, electrostatic dissipation, manufacturing, testing, and material engineering participate in an exercise that identifies contaminants and minimizes the complexity of scheduling these facilities considering their volatile schedules. Care can be taken in an efficient manner to insure correct cleaning processes are employed. The result is reduction in cycle time ("schedule hits"), reduced cost due to rework, reduced risk and improved communication and quality while achieving adherence to the Contamination Control Plan.

Wilcox, Margaret

Thinking Inside the Box: A Hands-On Student Activity for Building a Contamination Containment Glovebox to Encourage Problem Solving in a Collaborative Environment

Contamination containment gloveboxes are sealed containers where operators outside the glovebox can safely manipulate hazardous or contamination-sensitive materials inside the glovebox through glove ports on the container. Containment gloveboxes are used in the space industry to study sample materials returned from space such as lunar, asteroid, and comet materials, to manufacture sensitive instruments and space ight hardware, and to perform contamination-sensitive experiments. A hands-on activity has been developed by contamination control engineer and STEM education experts as part of the Virginia Earth System Science Scholars (VESSS) summer academy program to teach high school students about gloveboxes and about problem solving in a collaborative environment. In this activity, student teams are given a list of common household materials (e.g. plastic bags, plastic straws, aluminum foil, tape, disposable gloves, etc.) for building their own glovebox. Students work together to sketch and design their glovebox before being provided a kit of materials, which they must purchase along with any extra materials with a mock team budget. They are given 30 minutes to build their glovebox, however, they do not know what will be placed inside the glovebox or what operations they will need to perform within the glovebox. At the end of the build time, teams are given a small, sealed paper envelope which they place in the glovebox. Each team selects a team member to be designated as the operator, and the operator places their hands in the gloves of the glovebox. The operator uses their gloves to open the envelope in the glovebox, and they discover they have 20 minutes to assemble a jigsaw puzzle. However, the puzzle is \contaminated" with talcum powder. After the 20 minute time period, teams are judged on how well they completed and cleaned the contaminated puzzle. In a post-activity debrief, teams discuss lessons learned such as how the actual built box di ered from the sketched design, the challenge of managing a budget for materials, how the team dealt with surprises, and if their glovebox allowed enough room for the operator to perform the task. This activity has been part of the VESSS summer academy since 2016, and teaches students teamwork, creativity, hands-on experimentation, communication, and reasoning skills. In a demonstration at IAC, a volunteer from the audience will be chosen to assemble a glovebox during the presentation using the same kit of materials and will demonstrate handling puzzle pieces in the completed glovebox.

Elaine Seasly

Costs and Risks of Continuous Purges for Instruments

As instruments are built, tested, and launched, they are exposed to environments that have various levels of cleanliness. Often, Scientists and Contamination Control Engineers specify a purge to mitigate the instrument's exposure to a non-clean environment, protect sensitive optics from a specific threat, such as water, or as insurance against things going wrong in a clean environment. The cost of the purge, in effort, dollars and risk, is often understated when the requirements are being established, and the need for purge is not clearly justifiable. This paper will more clearly define some of the costs and risks associated with the continuous purging of instruments during the course of building, testing and launching instruments.

Secunda, M.

Contamination Control for Thermal Engineers

The presentation will be given at the 26th Annual Thermal Fluids Analysis Workshop (TFAWS 2015) hosted by the Goddard Spaceflight Center (GSFC) Thermal Engineering Branch (Code 545). This course will cover the basics of Contamination Control, including contamination control related failures, the effects of contamination on Flight Hardware, what contamination requirements translate to, design methodology, and implementing contamination control into Integration, Testing and Launch.

Design

Shuttle primary reaction control system engine exhaust plume contamination effects

Space Shuttle proximity operations constitute an important part of the SSF induced external environment. The impingement of primary reaction control system (PRCS) engine plumes on SSF functional surfaces during docking or berthing and separation leads to concerns about molecular contamination and high speed particle impact. The Shuttle Plume Impingement flight Experiment (SPIE) was designed to provide a direct measure of both the molecular contamination and particle impact rates produced by Shuttle PRCS engines in the LEO environment. The measured permanent deposition produced by PRCS engine firings was less than that assumed in current SSF programatic assessments. Only two to three possible high velocity particle impact pits were observed on the RMS end effector hardware.

Koontz, Steve

Thermal Vacuum Chamber Repressurization with Instrument Purging

At the conclusion of cryogenic vacuum testing of the James Webb Space Telescope Optical Telescope Element Integrated Science Instrument Module (JWST-OTIS) in NASA Johnson Space Center’s (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are postulating that chamber particulate material stirred up by the repressurization process may be kept from falling into the Integrated Science Instrument Module (ISIM) interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This manuscript describes development of a series of models designed to describe this process. The models are strung together in tandem with a fictitious set of conditions to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

Repressurization

Thermal Vacuum Chamber Repressurization with Instrument Purging

At the end of James Webb Space Telescope (JWST) OTIS (Optical Telescope Element-OTE-Integrated Science Instrument Module-ISIM) cryogenic vacuum testing in NASA Johnson Space Centers (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are mooting the idea that chamber particulate material stirred up by the repressurization process may be kept from falling into the ISIM interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This memo describes development of a series of models designed to describe this process. These are strung together in tandem to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

Venting

Establishing and Monitoring an Aseptic Workspace for Building the MOMA Mass Spectrometer

Mars Organic Molecule Analyzer (MOMA) is an instrument suite on the ESA ExoMars 2018 Rover, and the Mass Spectrometer (MOMA-MS) is being built at Goddard Space Flight Center (GSFC). As MOMA-MS is a life-detection instrument and it thus falls in the most stringent category of Planetary Protection (PP) biological cleanliness requirements. Less than 0.03 sporem2 is allowed in the instrument sample path. In order to meet these PP requirements, MOMA-MS must be built and maintained in a low bioburden environment. The MOMA-MS project at GSFC maintains three cleanrooms with varying levels of bioburden control. The Aseptic Assembly Cleanroom has the highest level of control, applying three different bioburden reducing methods: 70 IPA, 7.5 Hydrogen Peroxide, and Ultra-Violet C light. The three methods are used in rotation and each kills microbes by a different mechanism, reducing the likelihood of microorganisms developing resistance to all three. The Integration and Mars Chamber Cleanrooms use less biocidal cleaning, with the option to deploy extra techniques as necessary. To support the monitoring of cleanrooms and verification that MOMA-MS hardware meets PP requirements, a new Planetary Protection lab was established that currently has the capabilities of standard growth assays for spore or vegetative bacteria, rapid bioburden analysis that detects Adenosine Triphosphate (ATP), plus autoclave and DHMR verification. The cleanrooms are monitored both for vegetative microorganisms and by rapid ATP assay, and a clear difference in bioburden is observed between the aseptic the other cleanroom.

Contamination Control Engineering