Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Uniform apparent contrast noise: A picture of the noise of the visual contrast detection system

A picture which is a sample of random contrast noise is generated. The noise amplitude spectrum in each region of the picture is inversely proportional to spatial frequency contrast sensitivity for that region, assuming the observer fixates the center of the picture and is the appropriate distance from it. In this case, the picture appears to have approximately the same contrast everywhere. To the extent that contrast detection thresholds are determined by visual system noise, this picture can be regarded as a picture of the noise of that system. There is evidence that, at different eccentricities, contrast sensitivity functions differ only by a magnification factor. The picture was generated by filtering a sample of white noise with a filter whose frequency response is inversely proportional to foveal contrast sensitivity. It was then stretched by a space-varying magnification function. The picture summmarizes a noise linear model of detection and discrimination of contrast signals by referring the model noise to the input picture domain.

Ahumada, A. J., Jr.↗

High Contrast Vacuum Nuller Testbed (VNT) Contrast, Performance and Null Control

Herein we report on our Visible Nulling Coronagraph high-contrast result of 109 contrast averaged over a focal planeregion extending from 14 D with the Vacuum Nuller Testbed (VNT) in a vibration isolated vacuum chamber. TheVNC is a hybrid interferometriccoronagraphic approach for exoplanet science. It operates with high Lyot stopefficiency for filled, segmented and sparse or diluted-aperture telescopes, thereby spanning the range of potential futureNASA flight telescopes. NASAGoddard Space Flight Center (GSFC) has a well-established effort to develop the VNCand its technologies, and has developed an incremental sequence of VNC testbeds to advance this approach and itsenabling technologies. These testbeds have enabled advancement of high-contrast, visible light, nulling interferometry tounprecedented levels. The VNC is based on a modified Mach-Zehnder nulling interferometer, with a W configurationto accommodate a hex-packed MEMS based deformable mirror, a coherent fiber bundle and achromatic phase shifters.We give an overview of the VNT and discuss the high-contrast laboratory results, the optical configuration, criticaltechnologies and null sensing and control.

visible nulling coronagraph↗

Contrasting effects of glutamate and branched-chain amino acid metabolism on acid tolerance in a Castellaniella isolate from acidic groundwater

Groundwater acidification co-occurring with nitrate pollution is a common, global environmental health hazard. Denitrifying bacteria have been leveraged for the in situ removal of nitrate in groundwater. However, co-existing stressors—such as low pH—reduce the efficacy of biological removal processes. Castellaniella sp. str. MT123 is a complete denitrifier that was isolated from acidic, nitrate-contaminated groundwater. The strain grows robustly by nitrate respiration at pH < 6.0, completely reducing nitrate to dinitrogen gas. Genomic analyses of MT123 revealed few previously characterized acid tolerance genes. Thus, we utilized a combination of proteomics, metabolomics, and competitive mutant fitness to characterize the genetic mechanisms of MT123 acclimation to growth under mildly acidic conditions. We found that glutamate accumulation is critical in the acid acclimation of MT123, possibly through consumption of intracellular protons via glutamate decarboxylation to GABA. This is despite the fact that MT123 lacks the canonical glutamate decarboxylase-glutamate/GABA antiporter system implicated in acid tolerance in other bacteria. In contrast, branched-chain amino acid (BCAA) accumulation was detrimental to cell growth at lower pHs, possibly through indirect mechanisms impacting the cellular glutamate pool. Genetic analysis previously linked MT123 to a population of Castellaniella that bloomed—concurrent to nitrate removal—during a biostimulation effort to reduce groundwater nitrate concentrations at MT123’s location of origin. Thus, our analyses provide novel insight into mechanisms of acclimation to acidic conditions in a strain with significant potential for nitrate bioremediation.

59 BASIC BIOLOGICAL SCIENCES↗

The Safety of Contrast Echocardiography: Report of the Committee on Contrast Echocardiography for the American Society of Echocardiography

The results of a survey of 363 physicians performing were evaluated to assess the relative safety of contrast echocardiography. Fifteen physicians reported a variety of transient side effects, including neurologic and respiratory symptoms. Although contrast echocardiography appeared to carry some risk for side effects, that risk was low (0.062%) and no residual side effects or complications were observed.

Bommer, W. J.↗

High Contrast Vacuum Nuller Testbed (VNT) Contrast, Performance and Null Control

Herein we report on our contrast assessment and the development, sensing and control of the Vacuum Nuller Testbed to realize a Visible Nulling Coronagraphy (VNC) for exoplanet detection and characterization. Tbe VNC is one of the few approaches that works with filled, segmented and sparse or diluted-aperture telescope systems. It thus spans a range of potential future NASA telescopes and could be flown as a separate instrument on such a future mission. NASA/Goddard Space Flight Center has an established effort to develop VNC technologies, and an incremental sequence of testbeds to advance this approach and its critical technologies. We discuss the development of the vacuum Visible Nulling Coronagraph testbed (VNT). The VNT is an ultra-stable vibration isolated testbed that operates under closed-loop control within a vacuum chamber. It will be used to achieve an incremental sequence of three visible-light nulling milestones with sequentially higher contrasts of 10(exp 8), 10(exp 9) and ideally 10(exp 10) at an inner working angle of 2*lambda/D. The VNT is based on a modified Mach-Zehnder nulling interferometer, with a "W" configuration to accommodate a hex-packed MEMS based deformable mirror, a coherent fiber bundle and achromatic phase shifters. We discuss the laboratory results, optical configuration, critical technologies and the null sensing and control approach.

Lyon, Richard G.↗

Effect of contrast on human speed perception

This study is part of an ongoing collaborative research effort between the Life Science and Human Factors Divisions at NASA ARC to measure the accuracy of human motion perception in order to predict potential errors in human perception/performance and to facilitate the design of display systems that minimize the effects of such deficits. The study describes how contrast manipulations can produce significant errors in human speed perception. Specifically, when two simultaneously presented parallel gratings are moving at the same speed within stationary windows, the lower-contrast grating appears to move more slowly. This contrast-induced misperception of relative speed is evident across a wide range of contrasts (2.5-50 percent) and does not appear to saturate (e.g., a 50 percent contrast grating appears slower than a 70 percent contrast grating moving at the same speed). The misperception is large: a 70 percent contrast grating must, on average, be slowed by 35 percent to match a 10 percent contrast grating moving at 2 deg/sec (N = 6). Furthermore, it is largely independent of the absolute contrast level and is a quasilinear function of log contrast ratio. A preliminary parametric study shows that, although spatial frequency has little effect, the relative orientation of the two gratings is important. Finally, the effect depends on the temporal presentation of the stimuli: the effects of contrast on perceived speed appears lessened when the stimuli to be matched are presented sequentially. These data constrain both physiological models of visual cortex and models of human performance. We conclude that viewing conditions that effect contrast, such as fog, may cause significant errors in speed judgments.

Stone, Leland S.↗

Infrared Contrast Analysis Technique for Flash Thermography Nondestructive Evaluation

The paper deals with the infrared flash thermography inspection to detect and analyze delamination-like anomalies in nonmetallic materials. It provides information on an IR Contrast technique that involves extracting normalized contrast verses time evolutions from the flash thermography infrared video data. The paper provides the analytical model used in the simulation of infrared image contrast. The contrast evolution simulation is achieved through calibration on measured contrast evolutions from many flat bottom holes in the subject material. The paper also provides formulas to calculate values of the thermal measurement features from the measured contrast evolution curve. Many thermal measurement features of the contrast evolution that relate to the anomaly characteristics are calculated. The measurement features and the contrast simulation are used to evaluate flash thermography inspection data in order to characterize the delamination-like anomalies. In addition, the contrast evolution prediction is matched to the measured anomaly contrast evolution to provide an assessment of the anomaly depth and width in terms of depth and diameter of the corresponding equivalent flat-bottom hole (EFBH) or equivalent uniform gap (EUG). The paper provides anomaly edge detection technique called the half-max technique which is also used to estimate width of an indication. The EFBH/EUG and half-max width estimations are used to assess anomaly size. The paper also provides some information on the "IR Contrast" software application, half-max technique and IR Contrast feature imaging application, which are based on models provided in this paper.

Koshti, Ajay↗

Effect of contrast on the active control of a moving line

In many passive visual tasks, human perceptual judgments are contrast dependent. To explore whether these contrast dependencies of visual perception also affect closed-loop manual control tasks, we examined visuomotor performance as humans actively controlled a moving luminance-defined line over a range of contrasts. Four subjects were asked to use a joystick to keep a horizontal line centered on a display as its vertical position was perturbed by a sum of sinusoids under two control regimes. The total root mean square (RMS) position error decreased quasi-linearly with increasing log contrast across the tested range (mean slope across subjects: -8.0 and -7.7% per log2 contrast, for the two control regimes, respectively). Frequency-response (Bode) plots showed a systematic increase in open-loop gain (mean slope: 1.44 and 1.30 dB per log2 contrast, respectively), and decrease in phase lag with increasing contrast, which can be accounted for by a decrease in response time delay (mean slope: 32 and 40 ms per log2 contrast, respectively). The performance data are well fit by a Crossover Model proposed by McRuer and Krendel, which allowed us to identify both visual position and motion cues driving performance. This analysis revealed that the position and motion cues used to support manual control under both control regimes appear equally sensitive to changes in stimulus contrast. In conclusion, our data show that active control of a moving visual stimulus is as dependent on contrast as passive perception and suggest that this effect is attributed to a shared contrast sensitivity early in the visual pathway, before any specialization for motion processing.

Contrast Sensitivity/physiology↗

Flash Infrared Thermography Contrast Data Analysis Technique

This paper provides information on an IR Contrast technique that involves extracting normalized contrast versus time evolutions from the flash thermography inspection infrared video data. The analysis calculates thermal measurement features from the contrast evolution. In addition, simulation of the contrast evolution is achieved through calibration on measured contrast evolutions from many flat-bottom holes in the subject material. The measurement features and the contrast simulation are used to evaluate flash thermography data in order to characterize delamination-like anomalies. The thermal measurement features relate to the anomaly characteristics. The contrast evolution simulation is matched to the measured contrast evolution over an anomaly to provide an assessment of the anomaly depth and width which correspond to the depth and diameter of the equivalent flat-bottom hole (EFBH) similar to that used as input to the simulation. A similar analysis, in terms of diameter and depth of an equivalent uniform gap (EUG) providing a best match with the measured contrast evolution, is also provided. An edge detection technique called the half-max is used to measure width and length of the anomaly. Results of the half-max width and the EFBH/EUG diameter are compared to evaluate the anomaly. The information provided here is geared towards explaining the IR Contrast technique. Results from a limited amount of validation data on reinforced carbon-carbon (RCC) hardware are included in this paper.

Koshti, Ajay↗

Normalized Temperature Contrast Processing in Infrared Flash Thermography

The paper presents further development in normalized contrast processing used in flash infrared thermography method. Method of computing normalized image or pixel intensity contrast, and normalized temperature contrast are provided. Methods of converting image contrast to temperature contrast and vice versa are provided. Normalized contrast processing in flash thermography is useful in quantitative analysis of flash thermography data including flaw characterization and comparison of experimental results with simulation. Computation of normalized temperature contrast involves use of flash thermography data acquisition set-up with high reflectivity foil and high emissivity tape such that the foil, tape and test object are imaged simultaneously. Methods of assessing other quantitative parameters such as emissivity of object, afterglow heat flux, reflection temperature change and surface temperature during flash thermography are also provided. Temperature imaging and normalized temperature contrast processing provide certain advantages over normalized image contrast processing by reducing effect of reflected energy in images and measurements, therefore providing better quantitative data. Examples of incorporating afterglow heat-flux and reflection temperature evolution in flash thermography simulation are also discussed.

Koshti, Ajay M.↗

A Method to Measure and Estimate Normalized Contrast in Infrared Flash Thermography

The paper presents further development in normalized contrast processing used in flash infrared thermography method. Method of computing normalized image or pixel intensity contrast, and normalized temperature contrast are provided. Methods of converting image contrast to temperature contrast and vice versa are provided. Normalized contrast processing in flash thermography is useful in quantitative analysis of flash thermography data including flaw characterization and comparison of experimental results with simulation. Computation of normalized temperature contrast involves use of flash thermography data acquisition set-up with high reflectivity foil and high emissivity tape such that the foil, tape and test object are imaged simultaneously. Methods of assessing other quantitative parameters such as emissivity of object, afterglow heat flux, reflection temperature change and surface temperature during flash thermography are also provided. Temperature imaging and normalized temperature contrast processing provide certain advantages over normalized image contrast processing by reducing effect of reflected energy in images and measurements, therefore providing better quantitative data. Examples of incorporating afterglow heat-flux and reflection temperature evolution in flash thermography simulation are also discussed.

Koshti, Ajay M.↗

The Path Towards High-Contrast Imaging with the VLTI: The Hi-5 Project

The development of high-contrast capabilities has long been recognized as one of the top priorities for the VLTI (Very Large Telescope Interferometer). As of today, the VLTI routinely achieves contrasts of a few 103 in the near-infrared with PIONIER (Precision Integrated-Optics Near-infrared Imaging ExpeRiment) (H band) and GRAVITY (K band). Nulling interferometers in the northern hemisphere and non-redundant aperture masking experiments have, however, demonstrated that contrasts of at least a few 10 (sup -3) are within reach using specific beam combination and data acquisition techniques. In this paper, we explore the possibility to reach similar or higher contrasts on the VLTI. After reviewing the state-of-the-art in high-contrast infrared interferometry, we discuss key features that made the success of other high-contrast interferometric instruments (e.g., integrated optics, nulling, closure phase, and statistical data reduction) and address possible avenues to improve the contrast of the VLTI by at least one order of magnitude. In particular, we discuss the possibility to use integrated optics, proven in the near-infrared, in the thermal near-infrared (L and M bands, 3-5 microns), a sweet spot to image and characterize young extra-solar planetary systems. Finally, we address the science cases of a high-contrast VLTI imaging instrument and focus particularly on exoplanet science (young exoplanets, planet formation, and exozodiacal disks), stellar physics (fundamental parameters and multiplicity), and extragalactic astrophysics (active galactic nuclei and fundamental constants). Synergies and scientific preparation for other potential future instruments such as the Planet Formation Imager are also briefly discussed. This project is called Hi-5 for High-contrast Interferometry up to 5 microns.

PIONIER (H band)↗

Speed estimates from grating patches are not contrast-normalized

We have previously shown that the perceived speed of a moving grating depends upon its contrast, with lower-contrast patterns appearing to move more slowly than otherwise identical higher-contrast patterns. To explain this finding while remaining consistent with the findings of McKee, Silverman and Nakayama [(1986) Vision Research, 26, 609-619], we proposed that this misperception might arise from a modified version of the contrast-normalization procedure, envisaged by Adelson and Bergen [(1986) The extraction of spatio-temporal energy in human and machine vision (pp. 135-139). Charleston, S.C.: IEEE Computer Society] as a necessary second stage of motion-energy models of human motion processing. Specifically, our previous results might be explained if the two gratings to be compared interfered with each other's normalization. To test this hypothesis we performed two experiments. Experiment 1 demonstrates that the contrast effects persist even when two grating patches to be compared are presented up to 5 sec apart so that they would not be expected to bias each other's normalization. Experiment 2 shows that the contrast effects are unchanged when the two grating patches are surrounded by a range of patterns whose contrast would be expected to interfere with any normalization process. These two results allow the rejection of the contrast-normalized motion-energy hypothesis as an explanation of human speed perception. We discuss the consequences of these results on models of speed processing in the human visual system.

NASA Center ARC↗

Human speed perception is contrast dependent

When two parallel gratings moving at the same speed are presented simultaneously, the lower-contrast grating appears slower. This misperception is evident across a wide range of contrasts (2.5-50 percent) and does not appear to saturate (e.g. a 50 percent contrast grating appears slower than a 70 percent contrast grating moving at the same speed). On average, a 70 percent contrast grating must be slowed by 35 percent to match a 10 percent contrast grating moving at 2 deg/sec (N = 6). Furthermore, the effect is largely independent of the absolute contrast level and is a quasi-linear function of log contrast ratio. A preliminary parametric study shows that, although spatial frequency has little effect, relative orientation is important. Finally, the misperception of relative speed appears lessened when the stimuli to be matched are presented sequentially.

Stone, Leland S.↗

Method and apparatus to characterize ultrasonically reflective contrast agents

A method and apparatus for characterizing the time and frequency response of an ultrasonically reflective contrast agent is disclosed. An ultrasonically reflective contrast agent is injected, under constant pressure, into a fluid flowing through a pump flow circuit. The fluid and the ultrasonically reflective contrast agent are uniformly mixed in a mixing chamber, and the uniform mixture is passed through a contrast agent chamber. The contrast agent chamber is acoustically and axially interposed between an ultrasonic transducer chamber and an acoustic isolation chamber. A pulse of ultrasonic energy is transmitted into the contrast agent chamber from the ultrasonic transducer chamber. An echo waveform is received from the ultrasonically reflective contrast agent, and it is analyzed to determine the time and frequency response of the ultrasonically reflective contrast agent.

Pretlow, Robert A., III↗

Precipitation of gadolinium from magnetic resonance imaging contrast agents may be the Brass tacks of toxicity

The formation of gadolinium-rich nanoparticles in multiple tissues from intravenous magnetic resonance imaging contrast agents may be the initial step in rare earth metallosis. The mechanism of gadolinium-induced diseases is poorly understood, as is how these characteristic nanoparticles are formed. Gadolinium deposition has been observed with all magnetic resonance imaging contrast agent brands. Aside from endogenous metals and acidic conditions, little attention has been paid to the role of the biological milieu in the degradation of magnetic resonance imaging contrast agents into nanoparticles. Herein, we describe the decomposition of the commercial magnetic resonance imaging contrast agents Omniscan and Dotarem in the presence of oxalic acid, a well-known endogenous compound. Omniscan dechelated rapidly and preluded measurement by the means available, while Dotarem underwent a two-step decomposition process. The decomposition of both magnetic resonance imaging contrast agents by oxalic acid formed gadolinium oxalate (Gd 2 [C 2 O 4 ] 3 , Gd 2 Ox 3 ). Furthermore, both observed steps of the Dotarem reaction involved the associative addition of oxalic acid. Adding protein (bovine serum albumin) increased the rate of dechelation. Displacement reactions could occur at lysosomal pH. Through these studies, we have demonstrated that magnetic resonance imaging contrast agents can be dissociated by endogenous molecules, thus illustrating a metric by which gadolinium-based contrast agents (GBCAs) might be destabilized in vivo.

Gadodiamide↗

Contrast affects flicker and speed perception differently

We have previously shown that contrast affects speed perception, with lower-contrast, drifting gratings perceived as moving slower. In a recent study, we examined the implications of this result on models of speed perception that use the amplitude of the response of linear spatio-temporal filters to determine speed. In this study, we investigate whether the contrast dependence of speed can be understood within the context of models in which speed estimation is made using the temporal frequency of the response of linear spatio-temporal filters. We measured the effect of contrast on flicker perception and found that contrast manipulations produce opposite effects on perceived drift rate and perceived flicker rate, i.e., reducing contrast increases the apparent temporal frequency of counterphase modulated gratings. This finding argues that, if a temporal frequency-based algorithm underlies speed perception, either flicker and speed perception must not be based on the output of the same mechanism or contrast effects on perceived spatial frequency reconcile the disparate effects observed for perceived temporal frequency and speed.

NASA Center ARC↗

The use of photographic methods in contrast enhancement of ERTS-1 images

The contrast of ERTS 70mm positive images can be enhanced to varying degrees by rephotographing the images with different types of negative films, and by overdeveloping the films with different developers. A combination of high contrast copy film (Kodak 5069) and a high energy developer (Kodak D-11) yields high contrast. Still greater contrast may be otbained by using a film of higher contrast capability and a developer of higher energy capability. Contrast can also be enhanced in the printing process with the use of highcontrast photographic papers, or with the use of polycontrast photographic paper and filters. Contrast enhancement by photocopying delineates topographic boundaries and may aid in the objective measurement of topographic parameters.

Harris, L. F.↗