Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contrast Sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gain, noise, and contrast sensitivity of linear visual neurons

Contrast sensitivity is a measure of the ability of an observer to detect contrast signals of particular spatial and temporal frequencies. A formal definition of contrast sensitivity that can be applied to individual linear visual neurons is derived. A neuron is modeled by a contrast transfer function and its modulus, contrast gain, and by a noise power spectrum. The distributions of neural responses to signal and blank presentations are derived, and from these, a definition of contrast sensitivity is obtained. This formal definition may be used to relate the sensitivities of various populations of neurons, and to relate the sensitivities of neurons to that of the behaving animal.

Watson, Andrew B.↗

Transfer of contrast sensitivity in linear visual networks

Contrast sensitivity is a useful measure of the ability of an observer to distinguish contrast signals from noise. Although usually applied to human observers, contrast sensitivity can also be defined operationally for individual visual neurons. In a model linear neuron consisting of a filter and noise source, this operational measure is a function of filter gain, noise power spectrum, signal duration, and a performance criterion. This definition allows one to relate the sensitivities of linear neurons at different levels in the visual pathway. Mathematical formulas describing these relationships are derived, and the general model is applied to the specific problem of relating the sensitivities of parvocellular LGN neurons and cortical simple cells in the primate.

Watson, Andrew B.↗

Motion-Contrast Sensitivity: Visibility of Motion Gradients of Various Spatial Frequencies

The purpose of our experiments was to estimate basic sensitivity to motion gradients and to evaluate the evidence for second-order integration and differentiation of motion signals. We measured sensitivity to spatially sinusoidal contrast modulation between two oppositely moving bandpass-filtered noise images. The motion-contrast sensitivity function, defined as the inverse of threshold modulation amplitude as a function of modulation spatial frequency, was bandpass in shape with declines at both highest and lowest frequencies. The functions for three noise spatial frequencies had approximately the same shape when modulation frequency was expressed as a fraction of noise frequency. We compared the data with a model in which linear motion filters, whose outputs are squared or rectified, are followed by a second stage of excitatory or inhibitory pooling. The data are consistent with a model in which (1) all excitatory pooling occurs at the linear stage and (2) the second stage contains a large inhibitory pooling area, with a radius approximately eight times that of the linear receptive field.

Watson, Andrew B.↗

Spatial covert attention increases contrast sensitivity across the CSF: support for signal enhancement

This study is the first to report the benefits of spatial covert attention on contrast sensitivity in a wide range of spatial frequencies when a target alone was presented in the absence of a local post-mask. We used a peripheral precue (a small circle indicating the target location) to explore the effects of covert spatial attention on contrast sensitivity as assessed by orientation discrimination (Experiments 1-4), detection (Experiments 2 and 3) and localization (Experiment 3) tasks. In all four experiments the target (a Gabor patch ranging in spatial frequency from 0.5 to 10 cpd) was presented alone in one of eight possible locations equidistant from fixation. Contrast sensitivity was consistently higher for peripherally- than for neutrally-cued trials, even though we eliminated variables (distracters, global masks, local masks, and location uncertainty) that are known to contribute to an external noise reduction explanation of attention. When observers were presented with vertical and horizontal Gabor patches an external noise reduction signal detection model accounted for the cueing benefit in a discrimination task (Experiment 1). However, such a model could not account for this benefit when location uncertainty was reduced, either by: (a) Increasing overall performance level (Experiment 2); (b) increasing stimulus contrast to enable fine discriminations of slightly tilted suprathreshold stimuli (Experiment 3); and (c) presenting a local post-mask (Experiment 4). Given that attentional benefits occurred under conditions that exclude all variables predicted by the external noise reduction model, these results support the signal enhancement model of attention.

Non-NASA Center↗

High Accuracy Coronagraph Flight Model For WFIRST–CGI Raw Contrast Sensitivity Analysis

A high-accuracy high-fidelity flight wavefront control (WFC) model is developed for detailed raw contrast sensitivity analysis of WFIRST-CGI. Built upon features of recently testbed validated model, it is further refined to combine a full Fresnel propagation diffraction model for high accuracy contrast truth evaluation, and an economical compact model for WFC purposes. Extensive individual raw contrast error sensitivities are evaluated systematically, both as known imperfections and as unknown calibration errors, for both spectroscopy mode and wide field-of-view mode with shaped pupil coronagraph. More than 90 distinct error items were identified, including system aberrations, optical misalignment, component manufacturing error, telescope interface related errors, etc. The result forms the basis for raw contrast error budget flow down to a sub-system level, where detailed specifications needed to aid in component design and manufacturing, mechanical alignment and instrument integration, and verification and validation operations. Evaluations are mostly automated, making it relatively easy for repeat runs of revised design or at new desired error quantity. Top error sensitivities and contrast floor contributors are discussed and several observations are noted.

Poberezhskiy, Ilya↗

Spatial contrast sensitivity - Effects of age, test-retest, and psychophysical method

Two different psychophysical methods were used to test the spatial contrast sensitivity in normal subjects from five age groups. The method of adjustment showed a decline in sensitivity with increasing age at all spatial frequencies, while the forced-choice procedure showed an age-related decline predominantly at high spatial frequencies. It is suggested that a neural component is responsible for this decline.

Higgins, Kent E.↗

Evaluation of Tablet-Based Methods for Assessment of Contrast Sensitivity

Some astronauts have suffered degradation of vision during long-duration space flight, suffering from a condition that has come to be known as Spaceflight Associated Neuro-ocular Syndrome (SANS). While related morphological changes can be observed with imaging technologies such as optical coherence tomography (OCT), it may be useful to have a rapid method for functional vision assessment. In this paper, we compare three tablet-based methods for rapid assessment of contrast sensitivity. First, a relatively novel method developed expressly for touch screens, in which the subject ”swipes” a frequency/contrast sweep grating to indicate the boundary between visible and invisible patterns; second, a method-of-adjustment task in which the subject adjusts the contrast of a grating patch up and down to bracket the visual threshold; and third, a traditional temporal two-alternative forced choice (2AFC) task, in which the subject is presented with a near-threshold stimulus in one of two intervals, and must report the interval containing the stimulus. The swipe method shows variability comparable to the 2AFC method, and shows good agreement in estimates of the spatial frequency of peak sensitivity. The absolute sensitivity estimated with the swipe method is higher than that of the other methods, perhaps because subjects are biased to trace outside of the visible pattern region, or perhaps due to stimulus differences.

Mulligan, Jeffrey B.↗

Color matrix display simulation based upon luminance and chromatic contrast sensitivity of early vision

This paper describes the design and operation of a new simulation model for color matrix display development. It models the physical structure, the signal processing, and the visual perception of static displays, to allow optimization of display design parameters through image quality measures. The model is simple, implemented in the Mathematica computer language, and highly modular. Signal processing modules operate on the original image. The hardware modules describe backlights and filters, the pixel shape, and the tiling of the pixels over the display. Small regions of the displayed image can be visualized on a CRT. Visual perception modules assume static foveal images. The image is converted into cone catches and then into luminance, red-green, and blue-yellow images. A Haar transform pyramid separates the three images into spatial frequency and direction-specific channels. The channels are scaled by weights taken from human contrast sensitivity measurements of chromatic and luminance mechanisms at similar frequencies and orientations. Each channel provides a detectability measure. These measures allow the comparison of images displayed on prospective devices and, by that, the optimization of display designs.

Martin, Russel A.↗

Rapid Assessment of Contrast Sensitivity with Mobile Touch-screens

The availability of low-cost high-quality touch-screen displays in modern mobile devices has created opportunities for new approaches to routine visual measurements. Here we describe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. We will demonstrate a prototype for Apple Computer's iPad-iPod-iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing,

mobile devices↗

A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

contrast sensitivity↗

Optimizing coronagraph designs to minimize their contrast sensitivity to low-order optical aberrations

The presence of optical aberrations in the entrance pupil of a coronagraph causes the stellar light to scatter about the occulting spot, reducing the effective contrast achievable. Even if these aberrations are sufficiently corrected with a deformable mirror to enable planet detection, small drifts in the optical alignment of the telescope introduce additional low-order aberrations.

Shaklan, Stuart B.↗

Contrast-Sensitivity Research

Report presents study of visual effects of frequencies of luminance patterns and particularly how frequency components affect visibilty of spatial phase differences over several octaves. Of interest to researchers engaged in development of algorithms relating to visual processing in robots, incorporation of human factors in design of visual displays, and development of set of rules visual system uses to reconstruct three-dimensional perception from two-dimensional neural representation.

Lawton, T. A.↗

DCT quantization matrices visually optimized for individual images

This presentation describes how a vision model incorporating contrast sensitivity, contrast masking, and light adaptation is used to design visually optimal quantization matrices for Discrete Cosine Transform image compression. The Discrete Cosine Transform (DCT) underlies several image compression standards (JPEG, MPEG, H.261). The DCT is applied to 8x8 pixel blocks, and the resulting coefficients are quantized by division and rounding. The 8x8 'quantization matrix' of divisors determines the visual quality of the reconstructed image; the design of this matrix is left to the user. Since each DCT coefficient corresponds to a particular spatial frequency in a particular image region, each quantization error consists of a local increment or decrement in a particular frequency. After adjustments for contrast sensitivity, local light adaptation, and local contrast masking, this coefficient error can be converted to a just-noticeable-difference (jnd). The jnd's for different frequencies and image blocks can be pooled to yield a global perceptual error metric. With this metric, we can compute for each image the quantization matrix that minimizes the bit-rate for a given perceptual error, or perceptual error for a given bit-rate. Implementation of this system demonstrates its advantages over existing techniques. A unique feature of this scheme is that the quantization matrix is optimized for each individual image. This is compatible with the JPEG standard, which requires transmission of the quantization matrix.

Watson, Andrew B.↗

HCIT Broadband Contrast Performance Sensitivity Studies

The High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Laboratory employs a broadband wavefront correction algorithm called Electric Field Conjugation (EFC) to obtain the required 10-10 contrast. This algorithm works with one deformable mirror (DM) to estimate the electric-field to be controlled, and with one or multiple DM's to create a "darkhole" in a predefined region of the image plane where terrestrial planets would be found. We have investigated the effects of absorbing dust particles on a flat optic, absorbing spots on the occulting mask, dead actuators on the DM, and the effects of control bandwidth on the efficiency of the EFC algorithm in a Lyot coronagraph configuration. The structural design of the optical system as well as the parameters of various optical elements used in the analysis is drawn from those of the HCIT system that have been implemented with one DM. The simulation takes into account the surface errors of various optical elements. Results of some of these studies have been verified by actual measurements.

Coronagraphy↗

WFIRST/AFTA Coronograph Contrast Performance Sensitivity Studies: Simulation Versus Experiment

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory, we have investigated through modeling and simulations the sensitivity of dark hole contrast in a Hybrid Lyot Coronagraph (HLC) for several error cases, including lateral and longitudinal translation errors of two deformable mirrors, DM1 and DM2, lateral and/or longitudinal translation errors of an occulting mask and a Lyot-Stop, clocking errors of DM1 and DM2, and the mismatch errors between the testbed and the model sensitivity matrices. We also investigated the effects of a control parameter, namely the actuator regularization factor, on the control efficiency and on the final contrast floor. We found several error cases which yield contrast results comparable to that observed on the HLC testbed. We present our findings in this paper.

Coronagraphy↗

WFIRST/AFTA coronograph contrast performance sensitivity studies: simulation versus experiment

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory, we have investigated through modeling and simulations the sensitivity of dark hole contrast in a Hybrid Lyot Coronagraph (HLC) for several error cases, including lateral and longitudinal translation errors of two deformable mirrors, DM1 and DM2, lateral and/or longitudinal translation errors of an occulting mask and a Lyot-Stop, clocking errors of DM1 and DM2, and the mismatch errors between the testbed and the model sensitivity matrices. We also investigated the effects of a control parameter, namely the actuator regularization factor, on the control efficiency and on the final contrast floor. We found several error cases which yield contrast results comparable to that observed on the HLC testbed. We present our findings in this paper.

Nemati, Bijan↗