Search NASA⌕ Search

SEARCH · Search NASA

Results for “Convective heat flux measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An Investigation of the Compatibility of Radiation and Convection Heat Flux Measurements

A method for determining time-resolved absorbed surface heat flux and surface temperature in radiation and convection environments is described. The method is useful for verification of aerodynamic, heat transfer and durability models. A practical heat flux gage fabrication procedure and a simple one-dimensional inverse heat conduction model and calculation procedure are incorporated in this method. The model provides an estimate of the temperature and heat flux gradient in the direction of heat transfer through the gage. This paper discusses several successful time-resolved tests of this method in hostile convective heating and cooling environments.

Liebert, Curt H.↗

Development of a laser-induced heat flux technique for measurement of convective heat transfer coefficients in a supersonic flowfield

A technique is developed to measure the local convective heat transfer coefficient on a model surface in a supersonic flow field. The technique uses a laser to apply a discrete local heat flux at the model test surface, and an infrared camera system determines the local temperature distribution due to heating. From this temperature distribution and an analysis of the heating process, a local convective heat transfer coefficient is determined. The technique was used to measure the load surface convective heat transfer coefficient distribution on a flat plate at nominal Mach numbers of 2.5, 3.0, 3.5, and 4.0. The flat plate boundary layer initially was laminar and became transitional in the measurement region. The experimental results agreed reasonably well with theoretical predictions of convective heat transfer of flat plate laminar boundary layers. The results indicate that this non-intrusive optical measurement technique has the potential to obtain high quality surface convective heat transfer measurements in high speed flowfields.

Porro, A. Robert↗

A laser-induced heat flux technique for convective heat transfer measurements in high speed flows

A technique is developed to measure the local convective heat transfer coefficient on a model surface in a supersonic flow field. The technique uses a laser to apply a discrete local heat flux at the model test surface, and an infrared camera system determines the local temperature distribution due to the heating. From this temperature distribution and an analysis of the heating process, a local convective heat transfer coefficient is determined. The technique was used to measure the local surface convective heat transfer coefficient distribution on a flat plate at nominal Mach numbers of 2.5, 3.0, 3.5, and 4.0. The flat plate boundary layer initially was laminar and became transitional in the measurement region. The experimentally determined convective heat transfer coefficients were generally higher than the theoretical predictions for flat plate laminar boundary layers. However, the results indicate that this nonintrusive optical measurement technique has the potential to measure surface convective heat transfer coefficients in high speed flow fields.

Porro, A. R.↗

A laser-induced heat flux technique for convective heat transfer measurements in high speed flows

A technique is developed to measure the local convective heat transfer coefficient on a model surface in a supersonic flow field. The technique uses a laser to apply a discrete local heat flux at the model test surface, and an infrared camera system determines the local temperature distribution due to the heating. From this temperature distribution and an analysis of the heating process, a local convective heat transfer coefficient is determined. The technique was used to measure the local surface convective heat transfer coefficient distribution on a flat plate at nominal Mach numbers of 2.5, 3.0, 3.5, and 4.0. The flat plate boundary layer initially was laminar and became transitional in the measurement region. The experimentally determined convective heat transfer coefficients were generally higher than the theoretical predictions for flat plate laminar boundary layers. However, the results indicate that this nonintrusive optical measurement technique has the potential to measure surface convective heat transfer coefficients in high-speed flowfields.

Porro, A. R.↗

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

Gas-Temperature Measurement With Minimal Perturbation

Method for measuring temperature of hot turbulent gases uses three heatflux calorimeters. One calorimeter measures radiative heat flux, while other two measure total heat flux (convective and radiative), at two different temperatures. Adapted for commercial uses in such operations as monitoring temperatures of flue gases, piped liquid or gaseous products, internal-combustion or jet engine exhausts.

Fu, T. S.↗

Corrections of Heat Flux Measurements on Launch Vehicles

Knowledge of aerothermally induced convective heat transfer is important in the design of thermal protection systems for launch vehicles. Aerothermal models are typically calibrated via the data from circular, in-flight, flush-mounted surface heat flux gauges exposed to the thermal and velocity boundary layers of the external flow. Typically, copper or aluminum Schmidt- Boelter gauges, which take advantage of the one-dimensional Fourier's law of heat conduction, are used to measure the incident heat flux. This instrumentation, when surrounded by low-conductivity insulation, has a wall temperature significantly lower than the insulation. As a result of this substantial disturbance to the thermal boundary layer, the heat flux incident on the gauge tends to be considerably higher than it would have been on the insulation had the calorimeter not been there. In addition, radial conductive heat transfer from the hotter insulation can cause the calorimeter to indicate heat fluxes higher than actual. An overview of an effort to develop and calibrate gauge correction techniques for both of these effects will be presented.

Reinarts, Thomas R.↗

Numerical study of the effects of boundary conditions on the measurement and calibration of gardon type heat flux sensors

To monitor the high-intensity heat flux conditions that occur in the space shuttle main engine (SSME), it is necessary to use specifically designed heat flux sensors. These sensors, which are of the Gardon-type, are exposed on the measuring face to high-intensity radiative and convective heat fluxes and on the other face to convective cooling. To improve the calibration and measurement accuracy of these gauges, researchers are studing the effect that the thermal boundary conditions have on gauge performance. In particular, they are studying how convective cooling effects the field inside the sensor and the measured heat flux. The first phase of this study involves a numerical study of these effects. Subsequent phases will involve experimental verification. A computer model of the heat transfer around a Garden-type heat flux sensor was developed. Two specific geometries are being considered are: (1) heat flux sensor mounted on a flat-plate; and (2) heat flux sensor mounted at the stagnation point of a circular cylinder. Both of these configurations are representative of the use of heat flux sensors in the components of the SSME. The purpose of the analysis is to obtain a temperature distribution as a function of the boundary conditions.

Krane, M.↗

A Green’s Function Sensor Fusion Approach for Evaluating Spacecraft Entry Heating From on-Board Thermal Instrumentation

During atmospheric entry, distributed thermal measurements are critical to enable the evaluation of heat loads on spacecraft thermal protection systems (TPS). In recent space exploration missions, Schmidt-Boelter-type heat flux gauges have been integrated into the TPS alongside conventional temperature measurement instrumentation to measure total (convective and radiative) and radiative heat transfer rates1,2. While direct heat flux sensors (HFS) are able to provide valuable information detailing the thermal loads experienced by spacecraft, the interpretation of these measurements in unsteady, convective environments requires a correction factor to account for local heating augmentations at the cold wall HFS surface2,3. Current efforts to estimate cold wall correction factors, and thus recover the hot wall TPS heat flux, rely on time-marching computational fluid dynamics (CFD) simulations2. Simulation-based methods are susceptible to large uncertainties, however, as they require estimations of vehicle trajectory, gas kinetics, wall catalysis models, and other flight conditions as input parameters2,4. Furthermore, CFD simulations are computationally expensive and cannot efficiently survey all possible entry scenarios, exacerbating the uncertainty of reconstructed hot wall heat flux values. These drawbacks motivate the development of alternative hot wall heat flux reconstruction methods that are not reliant on CFD-based correction factors.

Kenneth McAfee↗

A Green’s Function Sensor Fusion Approach for Evaluating Spacecraft Entry Heating From on-Board Thermal Instrumentation

During atmospheric entry, distributed thermal measurements are critical to enable the evaluation of heat loads on spacecraft thermal protection systems (TPS). In recent space exploration missions, Schmidt-Boelter-type heat flux gauges have been integrated into the TPS alongside conventional temperature measurement instrumentation to measure total (convective and radiative) and radiative heat transfer rates1,2. While direct heat flux sensors (HFS) are able to provide valuable information detailing the thermal loads experienced by spacecraft, the interpretation of these measurements in unsteady, convective environments requires a correction factor to account for local heating augmentations at the cold wall HFS surface2,3. Current efforts to estimate cold wall correction factors, and thus recover the hot wall TPS heat flux, rely on time-marching computational fluid dynamics (CFD) simulations2. Simulation-based methods are susceptible to large uncertainties, however, as they require estimations of vehicle trajectory, gas kinetics, wall catalysis models, and other flight conditions as input parameters2,4. Furthermore, CFD simulations are computationally expensive and cannot efficiently survey all possible entry scenarios, exacerbating the uncertainty of reconstructed hot wall heat flux values. These drawbacks motivate the development of alternative hot wall heat flux reconstruction methods that are not reliant on CFD-based correction factors.

Kenneth McAfee↗

A Green’s Function Sensor Fusion Approach for Evaluating Spacecraft Entry Heating From on-Board Thermal Instrumentation

During atmospheric entry, distributed thermal measurements are critical to enable the evaluation of heat loads on spacecraft thermal protection systems (TPS). In recent space exploration missions, Schmidt-Boelter-type heat flux gauges have been integrated into the TPS alongside conventional temperature measurement instrumentation to measure total (convective and radiative) and radiative heat transfer rates1,2. While direct heat flux sensors (HFS) are able to provide valuable information detailing the thermal loads experienced by spacecraft, the interpretation of these measurements in unsteady, convective environments requires a correction factor to account for local heating augmentations at the cold wall HFS surface2,3. Current efforts to estimate cold wall correction factors, and thus recover the hot wall TPS heat flux, rely on time-marching computational fluid dynamics (CFD) simulations2. Simulation-based methods are susceptible to large uncertainties, however, as they require estimations of vehicle trajectory, gas kinetics, wall catalysis models, and other flight conditions as input parameters2,4. Furthermore, CFD simulations are computationally expensive and cannot efficiently survey all possible entry scenarios, exacerbating the uncertainty of reconstructed hot wall heat flux values. These drawbacks motivate the development of alternative hot wall heat flux reconstruction methods that are not reliant on CFD-based correction factors.

Kenneth McAfee↗

The Laser Enhanced Arc-Jet Facility (LEAF-Lite): Simulating Convective and Radiative Heating with Arc-Jets and Multiple 50-KW CW Lasers

LEAF-Lite (Laser Enhanced Arc-Jet Facility) is a radiative laser heating facility that has been added to the 60 MW Interaction Heating Facility (IHF) convective plasma arc-jet located at NASA Ames Research Center. Together, these two systems can simulate both convective and radiative heating at heat fluxes reaching 551 W/cm2 by simultaneously combining a highest measured heat flux of 160 W/cm2 convective and 391 W/cm2 radiative heating on a 152-mm x 152-mm wedge model configuration. Adding radiant heating to an existing convective facility better simulates Earth atmospheric entry from hyperbolic lunarreturn speeds. The radiative heat is provided by multiple 50-kW CW IR lasers, which is nearly uniform across the illuminated surface with a total variation less than 6%, while the convective heat is provided by a high enthalpy plasma arc-jet. In a later phase, the facility will expand to test panel test articles of 432-mm x 432-mm and provide 100 W/cm2 of radiative heating in a plasma convective flow environment. The paper describes this new combined heating capability, its current testing conditions, and the unique application of the laser system with respect to the Orion test flight lunar orbits.

Cushman, Geoff↗

Laser Measurement Of Convective-Heat-Transfer Coefficient

Coefficient of convective transfer of heat at spot on surface of wind-tunnel model computed from measurements acquired by developmental laser-induced-heat-flux technique. Enables non-intrusive measurements of convective-heat-transfer coefficients at many points across surfaces of models in complicated, three-dimensional, high-speed flows. Measurement spot scanned across surface of model. Apparatus includes argon-ion laser, attenuator/beam splitter electronic shutter infrared camera, and subsystem.

Porro, A. Robert↗

Reversed-direction 2-point modelling applied to divertor conditions in DIII-D *

Abstract A predictive form of the extended 2-point model known as the ‘reverse 2-point model’, Rev2PM, is applied to a range of detachment levels in the open lower divertor of DIII-D, showing that the experimentally measured electron temperature ( T e ) and pressure ( p e ) at the divertor entrance can be calculated within 50% from target measurements, if and only if a posteriori corrections for convective heat flux are included in the model. Unlike the standard 2-point model, the Rev2PM calculates upstream scrape-off layer (SOL) quantities (such as separatrix T e and p e ) from target conditions (such as T e and parallel heat flux), with volumetric power and momentum losses depending solely on target T e . The Rev2PM is tested against a database of DIII-D inter-ELM divertor Thomson scattering measurements, built from a series of 6 MW, 1.3 MA, LSN H-mode discharges with varied main ion density, drift direction, and nitrogen puffing rate. Measured target T e ranged from 0.4–25 eV over this database, and upstream T e ranged from 5–60 eV. Poor agreement is found between upstream measurements and Rev2PM calculations that assume purely conductive parallel heat transport. However, introducing a posteriori corrections to account for convective heat transport brings the Rev2PM calculations within 50% of the measured upstream values across the dataset. These corrections imply that up to 99% of the parallel heat flux is carried by convection in detached conditions in the DIII-D open lower divertor, though further work is required to assess any potential dependencies on device size or divertor closure.

2-point model↗

Is There a Scalar Atmospheric Surface Layer Within a Convective Boundary Layer? Implications for Flux Measurements

Top‐down entrainment shapes the vertical gradients of sensible heat, latent heat, and CO 2 fluxes, influencing the interpretation of eddy covariance (EC) measurements in the unstable atmospheric surface layer (ASL). Using large eddy simulations for convective boundary layer flows, we demonstrate that decreased temperature gradients across the entrainment zone increase entrainment fluxes by enhancing the entrainment velocity, amplifying the asymmetry between top‐down and bottom‐up flux contributions. These changes alter scalar flux profiles, causing flux divergence or convergence and leading to the breakdown of the constant flux layer assumption (CFLA) in the ASL. As a result, EC‐measured fluxes either underestimate or overestimate “true” surface fluxes during divergence or convergence phases, contributing to energy balance non‐closure. The varying degrees of the CFLA breakdown are a fundamental cause for the non‐closure issue. These findings highlight the underappreciated role of entrainment in interpreting EC fluxes, addressing non‐closure, and understanding site‐to‐site variability in flux measurements.

eddy covariance fluxes of scalars↗

Remote sensing of air-sea interactions

A number of preliminary concepts for the measurement or inference of fluxes across the air-sea interface through remote sensing are proposed. All the methods are achievable from aircraft with state-of-the-art technology. Only one is now ready for space implementation. The focus is on cold outbreaks. Sensible (latent) heat flux is inferred from the difference between initial surface air temperature (vapor mixing ratio) and the downwind SST (and corresponding saturation mixing ratio). The downwind growth rate of the PBL as measured by lidar also provides estimates of surface heating and the cross-inversion entrainment velocity. The lidar also provides a measure of the depth of the inversion and its penetration by surface-forced convection; this permits estimates of the surface heat flux. Lidar and radiometric measurements of cloud top height and temperature provide means of deducing the temperature sounding downstream so that heating is computed with the aid of a known sounding upstream.

Atlas, D.↗