Search NASA⌕ Search

SEARCH · Search NASA

Results for “Convective heat flux measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

Reversed-direction 2-point modelling applied to divertor conditions in DIII-D *

Abstract A predictive form of the extended 2-point model known as the ‘reverse 2-point model’, Rev2PM, is applied to a range of detachment levels in the open lower divertor of DIII-D, showing that the experimentally measured electron temperature ( T e ) and pressure ( p e ) at the divertor entrance can be calculated within 50% from target measurements, if and only if a posteriori corrections for convective heat flux are included in the model. Unlike the standard 2-point model, the Rev2PM calculates upstream scrape-off layer (SOL) quantities (such as separatrix T e and p e ) from target conditions (such as T e and parallel heat flux), with volumetric power and momentum losses depending solely on target T e . The Rev2PM is tested against a database of DIII-D inter-ELM divertor Thomson scattering measurements, built from a series of 6 MW, 1.3 MA, LSN H-mode discharges with varied main ion density, drift direction, and nitrogen puffing rate. Measured target T e ranged from 0.4–25 eV over this database, and upstream T e ranged from 5–60 eV. Poor agreement is found between upstream measurements and Rev2PM calculations that assume purely conductive parallel heat transport. However, introducing a posteriori corrections to account for convective heat transport brings the Rev2PM calculations within 50% of the measured upstream values across the dataset. These corrections imply that up to 99% of the parallel heat flux is carried by convection in detached conditions in the DIII-D open lower divertor, though further work is required to assess any potential dependencies on device size or divertor closure.

2-point model↗

Is There a Scalar Atmospheric Surface Layer Within a Convective Boundary Layer? Implications for Flux Measurements

Top‐down entrainment shapes the vertical gradients of sensible heat, latent heat, and CO 2 fluxes, influencing the interpretation of eddy covariance (EC) measurements in the unstable atmospheric surface layer (ASL). Using large eddy simulations for convective boundary layer flows, we demonstrate that decreased temperature gradients across the entrainment zone increase entrainment fluxes by enhancing the entrainment velocity, amplifying the asymmetry between top‐down and bottom‐up flux contributions. These changes alter scalar flux profiles, causing flux divergence or convergence and leading to the breakdown of the constant flux layer assumption (CFLA) in the ASL. As a result, EC‐measured fluxes either underestimate or overestimate “true” surface fluxes during divergence or convergence phases, contributing to energy balance non‐closure. The varying degrees of the CFLA breakdown are a fundamental cause for the non‐closure issue. These findings highlight the underappreciated role of entrainment in interpreting EC fluxes, addressing non‐closure, and understanding site‐to‐site variability in flux measurements.

eddy covariance fluxes of scalars↗

New heat flux model for non-axisymmetric divertor infrared structures

A convective heat flux model for perturbed plasmas, based on guiding center ion drift in vacuum elds (A. Wingen, et al., Phys. Plasmas 21 (2014) 012509), has been updated. The old model only considered ion heat flux, while here also electron heat flux is included. The updated model predicts divertor heat flux distributions in non-axisymmetric (3D) plasmas with applied Resonant Magnetic Perturbation (RMP) fields, and includes electric scalar potentials. It is found that a radial electric field in the near Scrape-o Layer (SOL) can considerably shift the footprints toroidally, leading to a smearing out eff ect of the incident heat flux, while a simple model for sheath potential has little impact on footprints. Various approaches to model electron heat flux are studied. A convective electron model, based on collisionless free streaming, is found to yield the best agreement with measurements, while a conductive model requires a at temperature gradient inside lobes to yield acceptable peak heat ux values. A heuristic heat flux layer approach, based on a fixed layer width also requires a limited heat flux inside the last closed flux surface (LCFS); by selecting various locations of the LCFS, the results of the conductive or convective model can be recovered respectively. The sum of ion and electron heat fluxes, both obtained by the convective model, is compared to experimental data for multiple time slices in DIII-D. Strike point splitting is observed with peak heat fluxes and layer widths that compare well to infrared camera (IR) measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of PVD-coated chromium on the subcooled flow boiling performance of nuclear reactor cladding materials

Here we elucidate the separate effect of a thin Cr coating deposited by physical vapor deposition (PVD) on the subcooled flow boiling performance of zircaloy-4. First, we run flow boiling experiments on prototypical zircaloy-4 surfaces mimicking the scratch pattern and surface roughness of nuclear reactor claddings. Then, we PVD-coat a 0.3 µm thick chromium layer on the same exact surface and repeat the same flow boiling investigations. All experiments are run using deionized water at atmospheric pressure, flowing on a 1 × 3 cm 2 rectangular cross section channel at a rate of 1000 kg/m 2 /s and a subcooling of 10 K. We measure the average temperature of the boiling surface at increasing surface heat fluxes, covering a wide range of heat transfer regimes, from single-phase forced convection to the boiling crisis. We also record high-speed videos of the boiling process, which we postprocess to measure bubble nucleation site density, growth time, departure diameter and frequency. The surface analysis reveals that, while the chromium coating does not seem change the surface roughness and morphology, it improves surface wettability. However, it decreases the critical heat flux. The chromium coating causes an increase of nucleation temperature, bubble departure diameter and growth time, and a reduction of the nucleation site density. The concurrence of these observations indicates that a size reduction of the nucleation sites, conformally covered by the chromium coating, may be the cause of the boiling performance deterioration. We confirm this hypothesis repeating the same analysis on a FeCrAl sample prepared and tested using the same protocol as the zircaloy-4 sample, but with a different initial surface texture.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parallel convection and E × B drifts in the TCV snowflake divertor and their effects on target heat-fluxes

Parallel convection and E × B drifts act together to redistribute heat between the strike-points in the low field side snowflake minus (LFS SF–). The cumulative heat convection from both mechanisms is enhanced near the secondary X-point and is shown to dominate over heat conduction, partly explaining why the LFS SF– distributes power more evenly than the single null (SN) or other snowflake (SF) configurations. Pressure profiles at the entrance of the divertor are strongly affected by the position of the secondary X-point and magnetic field direction indicating the importance of E × B drifts. Pressure drops of up to 50% appear between the outer-midplane (OMP) and the divertor entrance enhancing the role of parallel heat convection. The electron temperature and density profiles and the radial turbulent fluxes measured at the OMP are largely unaffected by the changes in divertor geometry, even on flux surfaces where the connection length is infinite.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scalar Flux Profiles in the Unstable Atmospheric Surface Layer Under the Influence of Large Eddies: Implications for Eddy Covariance Flux Measurements and the Non‐Closure Problem

How convective boundary-layer (CBL) processes modify fluxes of sensible (SH) and latent (LH) heat and CO 2 (F c ) in the atmospheric surface layer (ASL) remains a recalcitrant problem. Here, large eddy simulations for the CBL show that while SH in the ASL decreases linearly with height regardless of soil moisture conditions, LH and F c decrease linearly with height over wet soils but increase with height over dry soils. This varying flux divergence/convergence is regulated by changes in asymmetric flux transport between top-down and bottom-up processes. Such flux divergence and convergence indicate that turbulent fluxes measured in the ASL underestimate and overestimate the “true” surface interfacial fluxes, respectively. While the non-closure of the surface energy balance persists across all soil moisture states, it improves over drier soils due to overestimated LH. The non-closure does not imply that F c is always underestimated; F c can be overestimated over dry soils despite the non-closure issue.

Geology↗

A Methodology for Estimating the Energy and Moisture Budget of the Convective Boundary Layer Using Continuous Ground-Based Infrared Spectrometer Observations

Abstract Land–atmosphere interactions play a critical role in both the atmospheric water and energy cycles. Changes in soil moisture and vegetation alter the partitioning of surface water and energy fluxes, influencing diurnal evolution of the planetary boundary layer (PBL). The mixing-diagram framework has proven useful in understanding the evolution of the heat and moisture budget within the convective boundary layer (CBL). We demonstrate that observations from the Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains site provide all of the needed inputs needed for the mixing-diagram framework, allowing us to quantify the impact from the surface fluxes, advection, radiative heating, encroachment, and entrainment on the evolution of the CBL. Profiles of temperature and humidity retrieved from the ground-based infrared spectrometer [Atmospheric Emitted Radiance Interferometer (AERI)] are a critical component in this analysis. Large-eddy simulation results demonstrate that mean mixed-layer values derived are shown to be critical to close the energy and moisture budgets. A novel approach demonstrated here is the use of network of AERIs and Doppler lidars to quantify the advective fluxes of heat and moisture. The framework enables the estimation of the entrainment fluxes as a residual, providing a way to observe the entrainment fluxes without using multiple lidar systems. The high temporal resolution of the AERI observations enables the morning, midday, and afternoon evolution of the CBL to be quantified. This work provides a new way to use observations in this framework to evaluate weather and climate models. Significance Statement The energy and moisture budget of the planetary boundary layer (PBL) is influenced by multiple sources, and accurately representing this evolution in numerical models is critical for weather forecasts and climate predictions. The mixing-diagram approach, driven by profiling observations as illustrated here, provides a powerful way to quantify the contributions from each of these sources. In particular, the energy and moisture mixed into the PBL from above the PBL can be determined accurately from ground-based remote sensors using this approach.

54 ENVIRONMENTAL SCIENCES↗

MODEL DEVELOPMENT AND VERIFICATION OF A 1,350°C AIR RECEIVER TEST SYSTEM

Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multicycle power plants. A novel additively manufactured (AM) silicon carbide (SiC), ceramic matrix composite (CMC) volumetric receiver was developed that consisted of a lattice structure, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous receiver was transferred to heated ambient air. The receiver acted as a convective heat exchanger, transferring heat to the fluid through convection. Engineering was facilitated to develop a high-temperature air receiver test bed at Sandia national Laboratories (SNL) capable of demonstrating a 50kWth open-loop volumetric SiC air receiver module developed by General Electric Aerospace Research (GE Aerospace). This paper presents the development of the high temperature AM SiC-CMC air receiver, the test bed, and the first testing operations of this device, which was experimentally demonstrated to achieve 1,350°C for over 3.5 hours of operation, based on input flux levels of 67–91 W/cm2 0.5-2.5 kg/s flow rates. From the test campaign results, based on the measured convective heat transfer to the airflow and bounded radiative-loss assumptions, the solar-thermal efficiency of HOTSSTAR test module was estimated to be approximately as high as 74% for representative test conditions.

14 SOLAR ENERGY↗

Generating Buoyancy-Driven Convection in Membrane Distillation

Membrane distillation (MD) is a thermally-driven desalination process that can treat hypersaline brines. Considerable MD literature has focused on mitigating temperature and concentration polarization. This literature largely neglects that temperature and concentration polarization increase the feed density near the membrane. With gravity properly oriented, this increase in density could trigger buoyancy-driven convection and increase permeate production. Convection could also be strengthened by heating the feed channel wall opposite the membrane. To investigate that possibility, we perform a series of experiments using a plate-and-frame direct contact MD system with an active membrane area of 300 cm2 and a feed channel wall heated using a resistive heater. The experiments measure the average transmembrane permeate flux for two gravitational orientations, feed Reynolds numbers between 128 and 1128, and wall heat fluxes up to 12 kW/m2. The results confirm that with gravity properly oriented, wall-heating can trigger buoyancy-driven convection for a wide range of feed Reynolds numbers, and increase permeate production between roughly 20 and 130 %. We estimate, however, that at high Reynolds numbers (Re > 800), more than 70 % of the wall heat is carried out of the MD system by the feed flow, without contributing to permeate production. This suggests the need for longer membranes and heat recovery steps in any future practical implementation.

buoyancy-driven convection↗

The Diurnal Cycle of East Pacific Convection, Moisture, and CYGNSS Wind Speed and Fluxes

The far eastern tropical Pacific is one of the rainiest locations on Earth. This region is characterized by a robust diurnal cycle with precipitation initiating over the Andes mountains in Colombia in the late afternoon and moving offshore overnight while organizing into mesoscale convective systems (MCSs). As the MCSs move westward, they can seed tropical easterly waves that develop into tropical cyclones. Novel measurements of near-surface wind speeds and latent heat flux (LHFLX) from the Cyclone Global Navigation Satellite System (CYGNSS) mission and ERA5 reanalysis are used to evaluate changes to regional flow patterns, moisture, and LHFLX that favor a strong westward propagating diurnal cycle of precipitation in this region. Days with strongly versus weakly westward propagating diurnal precipitation are compared during the extended boreal summer of the CYGNSS era (May–October 2018–2021). Strongly propagating days have a more moist lower troposphere with stronger vertically integrated moisture flux convergence than days with weakly propagating precipitation. The enhanced low-level moisture is supported by increased wind-driven LHFLX from stronger regional flows including the Choco and Caribbean Low-Level Jets and Panama and Papagayo gap winds. Increased offshore convergence and vorticity also help sustain convection during the days with strongly propagating precipitation. Background variations in the physical environment, as opposed to diurnal variations, seem more important for supporting a robust diurnal cycle of precipitation in the region.

54 ENVIRONMENTAL SCIENCES↗

Alternating conduction and convection drying of paper – an experimental analysis with a continuous data acquisition approach

In conventional multi-cylinder drying of paper and board, both conductive drying from steam-heated dryer cylinders and convective drying by flowing air over the paper surface in the pockets are used. Conductive drying from steam-heated drying cylinders is a critical component in providing the necessary thermal energy to paper and board as they dry. Steam temperature and internal and external resistances at the contacting surface are critical process parameters influencing the conductive drying process. An experimental setup was developed to study the alternating conductive and convective drying of paper and board. Paper sheet moisture, temperature, and temperature distribution within the heated platen and the instantaneous heat flux as the sheet was being dried were measured. The instantaneous heat flux, contact heat transfer coefficient, and drying rates were determined as drying proceeds. Experimental results, as well as comparisons to literature and commercial data, are presented. The conductive heat transfer coefficients determined were compared to traditional correlations normally used in the modeling of paper drying. Similarly, the convective heat and mass transfer coefficients are also determined and compared to literature data. In addition to the evaluation of alternating conductive and convective drying characteristics of paper and board, the potential inclusion of auxiliary energy components will also be included. Experimental results from the conduction and convection drying system are presented. Furthermore, this data will be useful in process development, intensification of manufacturing processes, and modeling and simulation of paper drying processes.

42 ENGINEERING↗

Overview of the first Wendelstein 7-X long pulse campaign with fully water-cooled plasma facing components

After a long device enhancement phase, scientific operation resumed in 2022. The main new device components are the water cooling of all plasma facing components and the new water-cooled high heat flux divertor units. Water cooling allowed for the first long-pulse operation campaign. A maximum discharge length of 8 min was achieved with a total heating energy of 1.3 GJ. Safe divertor operation was demonstrated in attached and detached mode. Stable detachment is readily achieved in some magnetic configurations but requires impurity seeding in configurations with small magnetic pitch angle within the edge islands. Progress was made in the characterization of transport mechanisms across edge magnetic islands: Measurement of the potential distribution and flow pattern reveals that the islands are associated with a strong poloidal drift, which leads to rapid convection of energy and particles from the last closed flux surface into the scrape-off layer. Using the upgraded plasma heating systems, advanced heating scenarios were developed, which provide improved energy confinement comparable to the scenario, in which the record triple product for stellarators was achieved in the previous operation campaign. However, a magnetic configuration-dependent critical heating power limit of the electron cyclotron resonance heating was observed. Exceeding the respective power limit leads to a degradation of the confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First snowflake divertor experiments in MAST-U tokamak

First snowflake (SF) divertor experiments in the MAST-U tokamak demonstrated steady-state snowflake-plus divertor configurations in 450 kA ohmic L-mode plasmas. The SF divertor configuration features a second poloidal field (PF) null in the divertor region close by or overlapping with the main X-point. The resulting low PF region and two additional divertor legs (strike points) may lead to additional power and particle flux sharing via a hypothesized convective cell, and increased plasma-wetted area and radiation. The free-boundary Grad–Shafranov equilibrium code FIESTA was used to design SF configurations with several inter-null distances and orientations. In the experiment, the SF configurations with inter-null distances 0.13–0.20 m and lasting 0.2–0.3 s were obtained. Parallel connection lengths between the midplane and the outer strike point in the SF configurations (evaluated at field lines 1–2 mm from the separatrix in the midplane) were 25–30 m, higher than in the standard divertor (20–25 m) or the Super-X divertor (25 m). Diagnostic measurements highlighted salient SF features. The infra-red video bolometer diagnostic showed that the radiated power peaking in the PF null region was not as pronounces as in the standard divertor. Divertor ion fluxes measured by target Langmuir probes showed increased ion flux in the plate region where a secondary SF strike point landed, concomitantly with the SF formation. These measurements may suggest that some particle and heat redistribution was taking place in the convective SF zone. The first SF experiments provide a basis for future SF studies in MAST-U tokamak with higher input power, improved plasma control and diagnostic measurements, to be compared with the modeling predictions of plasma convective SF mixing and lower density strike point detachment threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interactions Between Clouds and Wind-Driven Surface Heat Exchanges over Land

Earth system model experiments show that increasing horizontal resolution fundamentally alters the simulated soil-moisture-precipitation feedback. Kilometer-scale simulations often produce weaker or even negative feedback compared to coarse-resolution models. A key difference of kilometer-scale models is that they resolve mesoscale secondary circulations, including boundary layer horizontal rolls and cellular structures, in addition to cold pools and downdrafts associated with convective precipitation. However, because the relevant processes occur on yet-smaller scales, these circulations are often poorly resolved. This project demonstrated that boundary layer secondary circulations significantly affect surface heat exchanges and wind gusts, and that current model parameterizations can misrepresent these processes at kilometer-scale resolution. Using DOE Atmospheric Radiation Measurement (ARM) observations and targeted experiments with the DOE Energy Exascale Earth System Model (E3SM), we identified physically unrealistic wind gust and surface flux responses to secondary circulations, diagnosed a systematic overestimation of wind shear in convective cold pools, and uncovered a multivariate relationship between land surface fluxes and the scales of updrafts that form shallow cumulus clouds. These findings provide observation-based recommendations for improving parameterizations of surface fluxes and wind gusts in high-resolution Earth system models, thereby reducing uncertainty in convective storm prediction and land-atmosphere feedbacks.

54 ENVIRONMENTAL SCIENCES↗

Relative Contributions of Surface Parcel and Atmospheric Environment to Convective Potential during Interstorm Periods

Convective instability is affected by both surface heat fluxes into near-surface air parcels and the atmospheric profile encountered as these air parcels are lifted aloft. In this study, we investigate the evolution of buoyancy experienced by surface-based parcels, taking interstorm soil moisture drydowns as fundamental time periods. We use profile observations of atmospheric temperature and humidity from ground-based passive remote sensing and in situ observations available at the U.S. Department of Energy Atmospheric Radiation Measurement Southern Great Plains site in Oklahoma, United States, and examine drydown events during the warm seasons from 2017 to 2022. Results reveal new insights on the emergence and growth of convective available potential energy (CAPE) during drydowns. We observe that the peak convective potential appears in the afternoon and grows in the midtroposphere (68% of 66 drydown events), with the largest CAPE values toward the end of the drydown event. We also find that the near-surface parcel contributes more to the evolution of CAPE than the atmospheric environment (86% of drydown events). These findings highlight the importance of surface heat fluxes and moisture availability from surface-based parcels in modulating the evolution of atmospheric conditions favorable for convection, underscoring the interplay between surface processes and atmospheric dynamics in driving convective instability.

Atmosphere-land interaction↗

Modeling Spatial Heterogeneity in Surface Turbulent Heat Flux in the U.S. Southern Great Plains

Advances in numerical modeling of cloud dynamics are driving a need for improved land model prediction at convective storm scales. Here, satellite and ground-based vegetation remote sensing data were combined with land model experiments to more accurately characterize land surface spatial heterogeneity in the Community Land Model (CLM4.0). The new subgrid classification of plant functional types (PFT) and leaf area index (LAI) enables consistent comparison between models and ground-based flux measurements in the U.S. southern Great Plains. Errors in vegetation data sets (inferred from comparison between 250 m satellite and ground-based LAI), while large, had less impact on the simulated characteristics of spatial heterogeneity compared to errors in model representation of surface energy partitioning (between latent and sensible heat flux) and its relationship to LAI. Predicted spatial heterogeneity in surface energy partitioning was enhanced after replacing soil and stomatal resistance parameters with a new set that better predicts the observed relationship to LAI. These modifications increase the number of smaller (mesoscale) dry land patches having higher sensible heat flux. The parameter experiments suggest that vegetation state and processes (transpiration) act to broaden the size spectrum of surface heat flux heterogeneity, which can influence clouds and convective initiation. Moreover, improvements in vegetation input data and model parameters had partially compensating effects on surface flux heterogeneity, indicating the importance of evaluating input data and parameterizations together to improve prediction at higher spatial resolutions.

54 ENVIRONMENTAL SCIENCES↗

Multidisciplinary Constraints on the Thermal‐Chemical Boundary Between Earth's Core and Mantle

Abstract Heat flux from the core to the mantle provides driving energy for mantle convection thus powering plate tectonics, and contributes a significant fraction of the geothermal heat budget. Indirect estimates of core‐mantle boundary heat flow are typically based on petrological evidence of mantle temperature, interpretations of temperatures indicated by seismic travel times, experimental measurements of mineral melting points, physical mantle convection models, or physical core convection models. However, previous estimates have not consistently integrated these lines of evidence. In this work, an interdisciplinary analysis is applied to co‐constrain core‐mantle boundary heat flow and test the thermal boundary layer (TBL) theory. The concurrence of TBL models, energy balance to support geomagnetism, seismology, and review of petrologic evidence for historic mantle temperatures supports Q CMB ∼15 TW, with all except geomagnetism supporting as high as ∼20 TW. These values provide a tighter constraint on core heat flux relative to previous work. Our work describes the seismic properties consistent with a TBL, and supports a long‐lived basal mantle molten layer through much of Earth's history.

58 GEOSCIENCES↗