The compatible conversion system

Compatible conversion system centralizes the solution of general problems arising from the use of direct access mass storage. It also provides a simple stable interface for the conversion of production programs to process on third generation computer system.

Hoffman, F.↗

Comparative Investigation of System-Level Optimized Power Conversion System Architectures to Reduce LCOE for Large-Scale PV-Plus-Storage Farms

PV-plus-storage (PVS) has become a prevalent configuration for newly commissioned large-scale solar projects. However, the optimal power conversion system (PCS) architecture has not been investigated yet. This paper first validates the limited impact of inverter cost on LCOE and then explores a system-level optimized PCS architecture with extended LCOE reduction to proliferate large-scale dispatchable solar energy. Two state-of-the-art architectures including central inverters (CI), traditional 480/600 V string inverters (SI) are compared with newly proposed medium voltage string inverters (MVSI) and multiport DC transformer (MDCT). With verified layouts and single line diagrams (SLDs) of 20 MW PVS plants, the losses and costs breakdown of different architectures are extracted and the PCS related LCOEs are derived. In this analysis, all electrical bill of materials (EBOS) elements, inverters, battery storage and its associated components, are included, whose losses and costs are obtained from markets, manufacturers, and literature. Besides, the sensitivities of PCS-related LCOEs to Inverter-Loading-Ratio (ILR) are also investigated. Here, the results show that compared with CI and SI with 1.5 kV PV, 4 kV MVSI and 34 kV MDCT present an extended LCOE reduction across all ILR from 1.0 to 3.0, making them economically favorable candidates for PVS farms.

14 SOLAR ENERGY↗

Frequency conversion system

A frequency conversion system comprises first and second gain sources providing first and second frequency radiation outputs where the second gain source receives as input the output of the first gain source and, further, the second gain source comprises a Raman or Brillouin gain fiber for wave shifting a portion of the radiation of the first frequency output into second frequency radiation output to provided a combined output of first and second frequencies. Powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Raman/Brillouin amplifier or oscillator between the high power source and the NFM device. Further, polarization conversion using Raman or Brillouin wavelength shifting is provided to optimize frequency conversion efficiency in the NFM device.

Sanders, Steven↗

Power enhanced frequency conversion system

A frequency conversion system includes at least one source providing a first near-IR wavelength output including a gain medium for providing high power amplification, such as double clad fiber amplifier, a double clad fiber laser or a semiconductor tapered amplifier to enhance the power output level of the near-IR wavelength output. The NFM device may be a difference frequency mixing (DFM) device or an optical parametric oscillation (OPO) device. Pump powers are gain enhanced by the addition of a rare earth amplifier or oscillator, or a Ra-man/Brillouin amplifier or oscillator between the high power source and the NFM device.

Sanders, Steven↗

Heat Rejection Concepts for Brayton Power Conversion Systems

This paper describes potential heat rejection design concepts for closed Brayton cycle (CBC) power conversion systems. Brayton conversion systems are currently under study by NASA for Nuclear Electric Propulsion (NEP) applications. The Heat Rejection Subsystem (HRS) must dissipate waste heat generated by the power conversion system due to inefficiencies in the thermal-to-electric conversion process. Space Brayton conversion system designs tend to optimize at efficiencies of about 20 to 25 percent with radiator temperatures in the 400 to 600 K range. A notional HRS was developed for a 100 kWe-class Brayton power system that uses a pumped sodium-potassium (NaK) heat transport loop coupled to a water heat pipe radiator. The radiator panels employ a sandwich construction consisting of regularly-spaced circular heat pipes contained within two composite facesheets. Heat transfer from the NaK fluid to the heat pipes is accomplished by inserting the evaporator sections into the NaK duct channel. The paper evaluates various design parameters including heat pipe diameter, heat pipe spacing, and facesheet thickness. Parameters were varied to compare design options on the basis of NaK pump pressure rise and required power, heat pipe unit power and radial flux, radiator panel areal mass, and overall HRS mass.

Siamidis, John↗

Initial Test Results of a Dual Closed-Brayton-Cycle Power Conversion System

The dual Brayton power conversion system constructed for NASA Glenn Research Center (GRC) was acceptance tested April 2007 at Barber-Nichols, Inc., Arvada, Colorado. This uniquely configured conversion system is built around two modified commercial Capstone C30 microturbines and employs two closed-Brayton-cycle (CBC) converters sharing a common gas inventory and common heat source. Because both CBCs share the gas inventory, behavior of one CBC has an impact on the performance of the other CBC, especially when one CBC is standby or running at a different shaft speed. Testing performed to date includes the CBCs operating at equal and unequal shaft speeds. A test was also conducted where one CBC was capped off and the other was operated as a single CBC converter. The dual Brayton configuration generated 10.6 kWe at 75 krpm and a turbine inlet temperature of 817 K. Single Brayton operation generated 14.8 kWe at 90 krpm and a turbine inlet temperature of 925 K.

Johnson, Paul K.↗

Methods for locating ground faults and insulation degradation condition in energy conversion systems

Methods for determining a ground fault or insulation degradation condition within energy conversion systems are described. A method for determining a ground fault within an energy conversion system may include, in part, a comparison of baseline waveform of differential current to a waveform of differential current during operation for a plurality of DC current carrying conductors in an energy conversion system. A method for determining insulation degradation within an energy conversion system may include, in part, a comparison of baseline frequency spectra of differential current to a frequency spectra of differential current transient at start-up for a plurality of DC current carrying conductors in an energy conversion system. In one embodiment, the energy conversion system may be a photovoltaic system.

30 DIRECT ENERGY CONVERSION↗

Lunar electric power systems utilizing the SP-100 reactor coupled to dynamic conversion systems

An integration study was performed by Rocketdyne under contract to NASA-LeRC. The study was concerned with coupling an SP-0100 reactor to either a Brayton or Stirling power conversion system. The application was for a surface power system to supply power requirements to a lunar base. A power level of 550 kWe was selected based on the NASA Space Exploration Initiative 90-day study. Reliability studies were initially performed to determine optimum power conversion redundancy. This study resulted in selecting three operating engines and one stand-by unit. Integration design studies indicated that either the Brayton or Stirling power conversion systems could be integrated with the PS-100 reactor. The Stirling system had an integration advantage because of smaller piping size and fewer components. The Stirling engine, however, is more complex and heavier than the Brayton rotating unit, which tends to off-set the Stirling integration advantage. From a performance consideration, the Brayton had a 9 percent mass advantage, and the Stirling had a 50 percent radiator advantage.

Harty, Richard B.↗

Design of a pool boiler heat transport system for a 25 kWe advanced Stirling conversion system

The overall operating temperature and efficiency of solar-powered Stirling engines can be improved by adding a heat transport system to more uniformly supply heat to the heater head tubes. One heat transport system with favorable characteristics is an alkali metal pool boiler. An alkali metal pool boiler heat transport system was designed for a 25-kW advanced Stirling conversion system (ASCS). Solar energy concentrated on the absorber dome boils a eutectic mixture of sodium and potassium. The alkali metal vapors condense on the heater head tubes, supplying the Stirling engine with a uniform heat flux at a constant temperature. Boiling stability is achieved with the use of an enhanced boiling surface and noncondensible gas.

Anderson, W. G.↗

Method—Practices and Pitfalls in Voltage Breakdown Analysis of Electrochemical Energy-Conversion Systems

Many electrochemical energy-conversion systems are evaluated by polarization curves, which report the cell voltage across a range of current densities and are a global measure of operation and state of health. Mathematical models can be used to deconstruct the measured overall voltage and identify and quantify the voltage-loss sources, such as kinetic, ohmic, and mass-transport effects. These results elucidate the best pathways for improved performance. In this work, we discuss several voltage-breakdown methods and provide examples across different low-temperature, membrane-based electrochemical systems including electrolyzers, fuel cells, and related electrochemical energy-conversion devices. We present best practices to guide experimentalists and theorists in polarization-curve breakdown analysis.

30 DIRECT ENERGY CONVERSION↗

Optical Energy Transfer and Conversion System

An optical energy transfer and conversion system comprising a fiber spooler and an electrical power extraction subsystem connected to the spooler with an optical waveguide. Optical energy is generated at and transferred from a base station through fiber wrapped around the spooler, and ultimately to the power extraction system at a remote mobility platform for conversion to another form of energy. The fiber spooler may reside on the remote mobility platform which may be a vehicle, or apparatus that is either self-propelled or is carried by a secondary mobility platform either on land, under the sea, in the air or in space.

Stone, William C.↗

Cogeneration Technology Alternatives Study (CTAS). Volume 3: Energy conversion system characteristics

Six current and thirty-six advanced energy conversion systems were defined and combined with appropriate balance of plant equipment. Twenty-six industrial processes were selected from among the high energy consuming industries to serve as a frame work for the study. Each conversion system was analyzed as a cogenerator with each industrial plant. Fuel consumption, costs, and environmental intrusion were evaluated and compared to corresponding traditional values. The advanced energy conversion technologies indicated reduced fuel consumption, costs, and emissions. Fuel energy savings of 10 to 25 percent were predicted compared to traditional on site furnaces and utility electricity. With the variety of industrial requirements, each advanced technology had attractive applications. Fuel cells indicated the greatest fuel energy savings and emission reductions. Gas turbines and combined cycles indicated high overall annual savings. Steam turbines and gas turbines produced high estimated returns. In some applications, diesels were most efficient. The advanced technologies used coal derived fuels, or coal with advanced fluid bed combustion or on site gasifications. Data and information for both current and advanced energy conversion technology are presented. Schematic and physical descriptions, performance data, equipment cost estimates, and predicted emissions are included. Technical developments which are needed to achieve commercialization in the 1985-2000 period are identified.