Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cool Roof”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Consumer Guide to Cool Roofs

Learn how cool roofs can save you energy and money while improving the comfort of your home. This fact sheet from Energy Saver includes information on the benefits of cool roofs, how cool roofs work and can save energy and money, and how to select and buy cool roofing materials.

cool roofs, roofing materials, Energy Saver↗

Optimization of cool roof and night ventilation in office buildings: A case study in Xiamen, China

Increasing roof albedo (using a “cool” roof) and night ventilation are passive cooling technologies that can reduce the cooling loads in buildings, but existing studies have not comprehensively explored the potential benefits of integrating these two technologies. This study combines an experiment in the summer and transition seasons with an annual simulation so as to evaluate the thermal performance, energy savings and thermal comfort improvement that could be obtained by coupling a cool roof with night ventilation. A holistic approach integrating sensitivity analysis and multi-objective optimization is developed to explore key design parameters (roof albedo, night ventilation air change rate, roof insulation level and internal thermal mass level) and optimal design options for the combined application of the cool roof and night ventilation. The proposed approach is validated and demonstrated through studies on a six-storey office building in Xiamen, a cooling-dominated city in southeast China. Simulations show that combining a cool roof with night ventilation can significantly decrease the annual cooling energy consumption by 27% compared to using a black roof without night ventilation and by 13% compared to using a cool roof without night ventilation. Roof albedo is the most influential parameter for both building energy performance and indoor thermal comfort. Optimal use of the cool roof and night ventilation can reduce the annual cooling energy use by 28% during occupied hours when air-conditioners are on and reduce the uncomfortable time slightly during occupied hours when air-conditioners are off.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling potential air temperature reductions yielded by cool roofs and urban irrigation in the Kansas City Metropolitan Area

In this work, we evaluate two mitigation strategies for urban heat island (UHI) in the Kansas City Metropolitan Area (KCMA). Using the Weather Research and Forecasting (WRF) model, we assess the potential benefits of reflective “cool” roofs and urban irrigation on air temperature in typical summer conditions between 2011 and 2015, and during six of the strongest historical heat waves from 2005 to 2016. Under the typical summer conditions, we simulate 2-m air temperature for 10 summer weeks, finding average daytime (07:00–19:00 local time) temperature reductions of 0.08 and 0.28 °C for cool roofs and urban irrigation, respectively. During the six heat-wave episodes, we find daytime temperature reductions of 0.02 and 0.26 °C for the two scenarios, similar to those under typical summer conditions. Our results suggest that urban irrigation can be more efficient than cool roofs in mitigating UHI in metropolitan regions where the majority of the land cover is comprised of areas with low urban (i.e., non-vegetated) fractions. Finally, we find the alteration of surface conditions due to enhanced roof albedos influences precipitation within the WRF simulation, in particular during the heat waves. Further research would be necessary to determine the robustness of this last finding.

54 ENVIRONMENTAL SCIENCES↗

Comparison of different simulation programs in modeling the energy savings of cool roofs

The Roof Savings Calculator is a web-based application first developed in 2010 that uses detailed building energy simulations to calculate the energy savings of cool roofs for different building types in over 200 U.S. locations. Although modeling the heat flows of a roof may be straightforward at first glance, modeling the energy savings due to changes in the roof albedo is complicated because it involves modeling the interzone heat transfer between the attic and the conditioned space below. Since direct measurement of energy savings is also problematic, the authors have decided to compare what several independent detailed simulation programs show for the energy savings from cool roof strategies.

Huang, Yu (Joe)↗

Cost-Benefit Analysis For Indonesia Building Sector: Whole-Building Cooling Solutions

The Net Zero World (NZW) Initiative Collaborative Work Program with the Government of Indonesia (GoI) includes technical assistance and investment mobilization facilitation to accelerate deployment of energy efficiency technologies and solutions for the building sector. A February 2023 U.S.–Indonesia Joint Workshop on Decarbonizing the Building Sector yielded a NZW Indonesia Building Decarbonization Working Group (NZW IBDWG) with four sub-working groups (SWG): SWG-A National Center, SWG-B Capacity Building, SWG-C Investment and Financing, and SWG-D Pilot Projects. Technical analysis of whole-building cooling solutions for tropical climates of Indonesia was conducted by SWG-A to quantify energy savings, carbon dioxide reductions, and comfort improvements offered by 12 passive or low-energy cooling strategies: ceiling fans with and without thermostat setbacks; cool roofs; cool walls; exterior awnings; exterior shades; interior shades; insulated roofs; insulated walls; low-e windows; solar window films; and natural ventilation. Leveraging the results from SWG-A, cost-benefit analysis (CBA) was conducted by SWG-C to assess the consumer and national costs and impacts associated with these 12 cooling solutions. The evaluation involved estimating life-cycle costs (LCC), payback period (PBP), net present values (NPV), annual electricity burden change for low-income households, and reduced national annual power-sector generation demand by 2030, 2040, 2050, and 2060. This evaluation can help guide Indonesia’s Just Energy Transition Partnership (JETP) investments in policies and programs to advance research, development, deployment, and commercial adoption (RDDCA) of efficient residential building sector cooling technologies and solutions in Indonesia. Four key energy conservation measures (ECM) have been identified to reduce air-conditioning (AC) energy demand in single-family housing in Indonesia: ceiling fan with temperature setback (to 28.1 °Celcius from 25 °C); insulated walls; insulated roof; and cool roof. This study found that low-income households with AC installations in Indonesia currently face a high energy cost burden of approximately 10%. However, by implementing a ceiling fan with temperature setback, this burden could decrease to 2.5% today and further reduce to 1.3% by the year 2060. The PBP for a ceiling fan with temperature setback is one year, indicating one of the lowest LCC and best NPV. In the planned upcoming phase of CBA, a series of building cooling improvement scenarios can be further defined, incorporating more than one ECM in combination with socio-economic factors evaluated in the initial CBA phase. Additionally, the analysis of ECM effects in multifamily housing can be expanded. This broader national analysis aims to encompass a holistic and comprehensive system-level perspective, including factors such as avoided power sector infrastructure investments, domestic job creation, domestic manufacturing job creation, and gross domestic product (GDP) growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving

The building attic usually subjects to substantial solar heat gain and has much higher temperature compared to the conditioned living space during the day, especially in summer and in hot areas. Reducing attic temperature can reduce cooling energy consumption in buildings. However, conventional techniques such as cool roof or attic ventilation, suffer from either heating penalty in winter or limited attic temperature reduction. In this work, a new roof-integrated radiative air-cooling system is introduced, which couples radiative sky cooling with attic ventilation to reduce attic temperature. A radiative air cooler with 1.08 m 2 surface area is constructed using a recently developed daytime radiative sky cooling metamaterial [Zhai et al., Science 355, pp. 1062–1066, 2017]. Experimental tests show that sub-ambient air cooling is achieved throughout 24-h day-and-night cycle in a summer day with clear sky conditions. Depending on air flow rates, measured sub-ambient temperature reductions of air are 5–8°C at night and 3–5°C at noon under direct sunlight, respectively. An in-house model is first developed for the radiative air-cooling system, the model is then coupled with EnergyPlus to study annual energy saving of buildings. The performance of the radiative air-cooling system is compared with three reference systems: shingle roof, attic ventilation, and cool roof. Results show that for a single-family house, attic temperature can be substantially reduced by 15.5–21.0°C, varying with attic insulation level, compared to shingle roof on typical summer days. Compared to a shingle roof (solar reflectance 0.25, thermal emittance 0.9) residential building with attic insulations of R-30 (RSI-5.28), R-10 (RSI-1.76), and R-0.8 (RSI-0.14), the roof-integrated radiative air-cooling system can achieve annual cooling energy savings of 0.4–1.5 kWh/m 2 (4.6–18.8%), 1.2–3.6 kWh/m 2 (10.2–41.4%), and 3.7–11.8 kWh/m 2 (26.5–76.1%) respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Where Are White Roofs More Effective in Cooling the Surface?

Solar reflective roofs (also called white or cool roofs) are a common heat mitigation strategy. By reflecting more sunlight than regular roofs, cool roofs experience lower surface temperatures and produce less heating of the surrounding air. The effectiveness of cool roofs, quantified by the surface temperature difference between cool roofs and regular roofs ??????, is known to vary spatially. A common perception is that ?????? is controlled by solar radiation that reaches the roof surface. Here we use an Earth System Model and a surface energy balance model to show that the spatial variability of ??????, when normalized by the albedo difference between cool roofs and regular roofs (????), is in fact more controlled by an energy distribution factor that encodes the efficiencies of surface energy balance components in dissipating heat. Our results suggest that painting the roof white is more effective in reducing the roof surface temperature when the roof has less water holding capacity and smaller thermal admittance and is located in places with more solar radiation, less precipitation, and lower wind speed.

Wang, Linying↗

United States cool surfaces deployment plan

Solar-reflective building envelope surfaces, such as cool roofs and walls, can be especially helpful in disadvantaged communities that often have poorly insulated older homes, aging or absent air conditioning units, steep utility bills, polluted air, and high vulnerability and exposure to extreme heat. With support from the U.S. Department of Energy, our project seeks to dramatically increase the climate-appropriate deployment of cool surfaces across the United States with an emphasis on their application to disadvantaged communities. First, we sought to identify cool-surface deployment barriers, opportunities, and models by (a) reviewing the history of cool-surface deployment activities, (b) interviewing cool-surface stakeholders, (c) researching successful energy-efficiency/green building deployment models; and (d) interviewing the actors who have implemented these models. Second, we conducted a workshop to engage stakeholders in development of a deployment plan. Third, we asked several U.S. federal agencies (a) how cool surfaces and cool surface stakeholders could support their missions and (b) how agency activities could support cool-surface deployment. Fourth, we identified a set of transformative ideas that form the core of the deployment plan. Transformative ideas include but are not limited to initiatives to (a) launch an educational campaign to make the general public and building professionals aware of how cool roofs and walls exclude unwanted solar heat; (b) create a “Cool Roof Prize” stimulating the development of affordable, high-performance cool asphalt roofing shingles; (c) conduct high-profile, large-scale demonstration programs that bring cool surfaces to disadvantaged heat-vulnerable communities; and (d) support local, regional, and state climate action (heat mitigation) plans with cool surfaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bright is the New Black - Multi-Year Performance of Generic High-Albedo Roofs in an Urban Climate

High-albedo white and cool roofing membranes are recognized as a fundamental strategy that dense urban areas can deploy on a large scale, at low cost, to mitigate the urban heat island effect. We are monitoring three generic white membranes within New York City that represent a cross-section of the dominant white membrane options for U.S. flat roofs: (1) an ethylene propylene diene monomer (EPDM) rubber membrane; (2) a thermoplastic polyolefin (TPO) membrane and; (3) an asphaltic multi-ply built-up membrane coated with white elastomeric acrylic paint. The paint product is being used by New York City s government for the first major urban albedo enhancement program in its history. We report on the temperature and related albedo performance of these three membranes at three different sites over a multi-year period. The results indicate that the professionally installed white membranes are maintaining their temperature control effectively and are meeting the Energy Star Cool Roofing performance standards requiring a three-year aged albedo above 0.50. The EPDM membrane however shows evidence of low emissivity. The painted asphaltic surface shows high emissivity but lost about half of its initial albedo within two years after installation. Given that the acrylic approach is an important "do-it-yourself," low-cost, retrofit technique, and, as such, offers the most rapid technique for increasing urban albedo, further product performance research is recommended to identify conditions that optimize its long-term albedo control. Even so, its current multi-year performance still represents a significant albedo enhancement for urban heat island mitigation.

Gaffin, S. R.↗

How can we combine urban cooling strategies to effectively cool cities over the entire diurnal cycle?

The urban heat island effect generally peaks in the night/evening hours and, in some cases, an urban cool island effect during daytime has been reported. These patterns are observed mainly because of the widespread use of impervious and thermally massive materials (like concrete and asphalt) in the built environment and their ability to store energy during the daytime and release it at night. Unfortunately, most urban cooling strategies, such as cool (white), green, and blue spaces, provide better thermal performance during the daytime than at night. Hence, such solutions are not ideal for nighttime heat mitigation. In this study, we investigate the effect of the thermal storage capacity of existing buildings on nighttime urban air temperature for a hot arid city—Phoenix, and a hot humid city—Atlanta. The study uses regional scale atmospheric modeling to compare the nighttime urban cooling capability of thermally light buildings (Cross-laminated timber buildings in this case) with concrete buildings. The results show that the adoption of thermally light buildings reduce nighttime air temperatures, and slightly increases daytime air temperatures. On the other hand, cool roof adaption could reduce urban air temperature significantly during the daytime and slightly at night. Therefore, together with cool roofs, thermally light buildings may be able to cool the surrounding air by an average of about 1°C throughout the diurnal cycle, providing thermal comfort and reducing cooling demand during all hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategies to mitigate urban heat: Effects on overheating and cloud formation

This study evaluates the effectiveness of various urban heat island (UHI) overheating mitigation strategies and their associated impacts on urban cloud dynamics and thermal processes. This study shows cloud-resolving and urban-resolving modeling results estimating the impact of Houston-Galveston heat mitigation scenarios and other resilient strategies contemplated in the Climate Adaptation Plan and Resilient Houston reports. The simulated scenarios include high intensity green rooftops, rooftop photovoltaic solar panels, enhanced urban irrigation, white/cool roofs and roads, and street trees. We contrast the adaptation scenarios against a present baseline case, a no city scenario and a larger and denser city as projected by the Houston-Galveston Area Council for 2045. During the daytime, cooling strategies such as cool roofs, cool roads, and green roofs exhibit superior performance in mitigating urban overheating. At night, enhanced urban irrigation emerges as the most effective cooling intervention. Cooling strategies significantly reduce sensible heat flux partitioning during the day, a process that reduces the uplift of air, suppressing the formation of urban shallow cumulus clouds. The extent of urban cloud mixing ratio is reduced in proportion to the decrease in sensible heating. Under the BEP-Tree scenario, which includes wind effects and evapotranspiration driven by a stomatal conductance model, urban trees demonstrated negligible environmental cooling effects and minimal urban cloud modifications. In contrast, the scenarios with more urban cooling and higher latent heat fluxes led to suppressed urban clouds. The net cooling effect achieved by the heat mitigation strategies is influenced by a combination of indirect processes, including the reduction of downwelling longwave radiation flux, due to reduced cloud presence, while some warming is attributed to a modest increase in shortwave radiation that offsets the cooling benefit. Additionally, reduced heat dissipation, weakened thermal gradients, and diminished vertical mixing over urban areas further moderate the cooling potential. These findings highlight the pivotal role of clouds and moist atmospheric processes in shaping the UHI effect and offer insights for designing more effective urban cooling strategies.

albedo changes↗

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strong influence of convective heat transfer efficiency on the cooling benefits of green roof irrigation

Abstract By enhancing evapotranspiration (ET), green roofs provide cooling benefits for the urban environment and are recognized as a promising heat mitigation strategy. The evaporative cooling effects of green roofs strongly depend on the soil moisture conditions and thus irrigation may be needed to sustain the cooling benefits. It has been shown that the magnitude of cooling benefits offered by green roof irrigation varies spatially, but its controlling factors remain elusive. In this study, we combine a surface energy balance (SEB) model with global simulations generated by an improved Earth System Model to illustrate the key factors controlling the cooling benefits of green roof irrigation. We employ a simple irrigation scheme, which is only active when there is no ice in soil layers and when the soil moisture is below field capacity. As a result, most of the irrigation water leaves the green roof system via ET. We find that the magnitude and also the spatial variability of the cooling benefits of green roof irrigation are controlled by the irrigation amount, and a surface energy redistribution factor that encodes the efficiencies of different SEB components in transferring heat. Further analysis indicates that the enhancement of latent heat flux due to irrigation is largely balanced by the reduction of sensible heat flux on green roofs. Therefore, the amount of irrigation needed per unit decrease of green roof surface temperature is mainly controlled by the convective heat transfer efficiency. A lower convective heat transfer efficiency (e.g. under a lower wind speed) helps reduce the amount of irrigation needed per unit decrease of green roof surface temperature. This study highlights the importance of SEB in constraining the cooling benefits of green roof irrigation and provides valuable guidance for urban planners and policy makers in terms of heat mitigation and sustainable water management.

Wang, Linying (ORCID:0000000308769220)↗

Self-cleaning and de-pollution efficacies of photocatalytic architectural membranes

Photocatalytic self-cleaning “cool” roofs and walls can maintain high albedos, saving building cooling energy, reducing peak power demand, and mitigating the urban heat island effect. Other environmental benefits result from their de-polluting properties. Specimens from two different photocatalytic architectural membranes and a non-photocatalytic control were exposed alongside vertically, facing west, for two years at three California sites, and retrieved quarterly for testing. Photocatalytic materials showed excellent self-cleaning performance, retaining albedos of 0.74 – 0.75. By contrast, the control material exhibited an albedo loss of up to 0.10, with appreciable soiling observed by scanning electron microscopy. De-pollution capacity was assessed by quantifying NO removal and NOx deposition rates at 60 °C. Furthermore, efficacy varied with exposure location, weather conditions, and the nature of the photocatalytic material. Seasonal effects were observed, with partial inhibition during the dry season and reactivation during the rainy season.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing the cooling effectiveness of operationalisable urban surface combination scenarios for summer heat mitigation

Extreme summer heat in cities exacerbates the vulnerability of urban communities to heatwaves. Vegetative and reflective urban surfaces can help reduce urban heat. This study investigated the impacts of urban trees, green roofs and cool roofs on heat mitigation during average and extreme summer conditions in temperate oceanic Melbourne, Australia. We simulated the city climate using ‘The Air Pollution Model’ (TAPM) at a 1 km spatial resolution over 10 years, which according to our review of the literature, was the most prolonged period for simulation in Melbourne. During a widespread heatwave event, some of the tested scenarios with combined surface parameters could reduce the extreme values of the energy budget components- sensible heat, latent heat, and storage heat fluxes up to seasonal averages compared to the existing situation for Melbourne (control). The scenario with the highest (reasonable maximum) ground-level vegetation, green roofs, and cool roofs could reduce air temperatures up to 2.4 °C. The simulations suggest that a combined strategy with vegetative and high-albedo surfaces will deliver higher effectiveness with maximum cooling benefits and cost-effectiveness than individual strategies in cities. These results suggest the importance of collaborative strategic planning of urban surfaces to make cities healthier, sustainable, and liveable.

54 ENVIRONMENTAL SCIENCES↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗