Overall Cooling Effectiveness of Internally Cooled Additively Manufactured Blades

Power generation gas turbine blades must utilize highly effective cooling schemes to withstand moderate heat loads for long operating times. Prior work indicates that gas turbines in the 5-10 MW range primarily utilize internal cooling to prevent further increase of aerodynamic losses that result from film cooling, but few studies focus solely on internal cooling. In this study, three additively manufactured internal cooling designs were tested in the 50 percent span section of the National Experimental Turbine (NExT) blade: a baseline cooling design with pin-fin arrays and rib turbulators, a double wall design with impingement jets and serpentine channels, and an incremental impingement design. The designs were tested in a high-speed linear cascade at exit Reynolds numbers ranging from 700,000 to 1,400,000 at an exit Mach of 0.8. In addition, freestream turbulence and build angle effects on cooling performance were studied.

gas turbine blades↗

How can we combine urban cooling strategies to effectively cool cities over the entire diurnal cycle?

The urban heat island effect generally peaks in the night/evening hours and, in some cases, an urban cool island effect during daytime has been reported. These patterns are observed mainly because of the widespread use of impervious and thermally massive materials (like concrete and asphalt) in the built environment and their ability to store energy during the daytime and release it at night. Unfortunately, most urban cooling strategies, such as cool (white), green, and blue spaces, provide better thermal performance during the daytime than at night. Hence, such solutions are not ideal for nighttime heat mitigation. In this study, we investigate the effect of the thermal storage capacity of existing buildings on nighttime urban air temperature for a hot arid city—Phoenix, and a hot humid city—Atlanta. The study uses regional scale atmospheric modeling to compare the nighttime urban cooling capability of thermally light buildings (Cross-laminated timber buildings in this case) with concrete buildings. The results show that the adoption of thermally light buildings reduce nighttime air temperatures, and slightly increases daytime air temperatures. On the other hand, cool roof adaption could reduce urban air temperature significantly during the daytime and slightly at night. Therefore, together with cool roofs, thermally light buildings may be able to cool the surrounding air by an average of about 1°C throughout the diurnal cycle, providing thermal comfort and reducing cooling demand during all hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overall Cooling Effectiveness With Internal Serpentine Channels and Optimized Film Cooling Holes

Abstract The overall cooling effectiveness for gas turbine airfoils is a function of the combined cooling due to internal cooling configurations and film cooling configurations. Typically, film cooling configurations are evaluated independent of the cooling effects of the internal feed channels, generally based on adiabatic effectiveness measurements. In this study, we consider the coupled effects of internal cooling and film cooling configurations through measurements of overall cooling effectiveness for film cooling holes fed by a coflow/counterflow channel and a serpentine channel. A film cooling hole designed by adjoint optimization techniques (X-AOpt) is compared to a standard-shaped hole with 7 deg forward and lateral expansions (7-7-7 SI). Experiments without film cooling showed that the serpentine channel had 35–50% greater overall cooling effectiveness than the straight, coflow channel. Experiments with the X-AOpt hole combined with a serpentine channel showed an area-averaged overall cooling effectiveness of ϕ¯¯=0.58, which was a 70% increase compared to the overall cooling effectiveness of the serpentine channel without film cooling. When the X-AOpt hole was fed with a coflow channel with similar coolant mass flowrate, the overall cooling effectiveness was ϕ¯¯=0.44, i.e., 30% lower than when using the serpentine channel. Interestingly, adiabatic effectiveness measurements with the X-AOpt holes showed a more uniform hole-to-hole performance when using the serpentine channel compared to the coflow channel.

Engineering↗

Overall Cooling Effectiveness of Internally Cooled Additively Manufactured Blades

By utilizing additive manufacturing, novel internal cooling designs can be quickly and cheaply vetted to enhance blade cooling performance. This improvement allows for higher turbine inlet temperatures while reducing the amount of coolant needed, therefore increasing the overall efficiency of small industrial gas turbines.

additive manufacturing↗

Cooling Effectiveness Measurements for Air Film Cooling of Thermal Barrier Coated Surfaces in a Burner Rig Environment Using Phosphor Thermometry

While the effects of thermal barrier coating (TBC) thermal protection and air film cooling effectiveness are usually studied separately, their contributions to combined cooling effectiveness are interdependent and are not simply additive. Therefore, combined cooling effectiveness must be measured to achieve an optimum balance between TBC thermal protection and air film cooling. In this investigation, surface temperature mapping was performed using recently developed Cr-doped GdAlO3 phosphor thermometry. Measurements were performed in the NASA GRC Mach 0.3 burner rig on a TBC-coated plate using a scaled up cooling hole geometry where both the mainstream hot gas temperature and the blowing ratio were varied. Procedures for surface temperature and cooling effectiveness mapping of the air film-cooled TBC-coated surface are described. Applications are also shown for an engine component in both the burner rig test environment as well as an engine afterburner environment. The effects of thermal background radiation and flame chemiluminescence on the measurements are investigated, and advantages of this method over infrared thermography as well as the limitations of this method for studying air film cooling are discussed.

air film cooling↗

Comparison of cooling effectiveness of turbine vanes with and without film cooling

The cooling effectiveness of three film-cooled vanes were compared to the cooling effectiveness of two non-film-cooled vanes. The comparison indicated that, for the vane configurations and test conditions examined, film cooling had an adverse effect near the suction-surface trailing edge of the vanes. Film cooling was found to be beneficial on the pressure surface of the vanes.

Yeh, F. C.↗

Simulation of jet cooling effects on Czochralski crystal growth

The effects of cooling the crystal side surface by blowing a jet of an inert gas are examined in detail for Czochralski crystal growth. A combined model of the crystal + melt, which incorporates the detailed radiation calculations, the shape of the melt-gas meniscus, predicts the growth rate and the crystal-melt interface shape, is used for this study. The convective heat transfer coefficient for the jet is estimated from the correlation available in the literature. The effect of the jet cooling on the interface shape and the pulling rate is significant. The crystal diameter as well as the interface shape tend to be more stable in the environment of the rapid cooling of the crystal by the jet. The crystal diameter or the interface shape can be easily controlled by adjusting the gas flow rate through the jet. This gives the Czochralski pulling an additional degree of freedom facilitating the control of crystal diameter and interface shape.

Srivastava, R. K.↗

The Effects of Channel Supplies on Overall Film-Cooling Effectiveness

Abstract Cooling components in the hot section of a gas turbine are essential to component durability. Common methods of cooling include rib turbulators in internal passages and film cooling on external surfaces. The holes that produce the film cooling are fed from the internal channels often containing ribs. Consequently, there is an interdependence of internal heat transfer and external film cooling. The purpose of this study was to obtain a better understanding of the interaction of ribs and film cooling. To quantify the cooling performance, the surface temperatures were measured, from which overall effectiveness was calculated. For the experiments, additively manufactured test coupons were made of Inconel 718 to match engine Biot numbers. These test coupons had internal feed channels with and without ribs and had both cylindrical holes and meter-diffuser-shaped holes with 15 deg lateral expansion angles and a 1 deg forward expansion angle. A single rectangular channel was one type of feed channel. The other type of feed channel was individual circular channels, with each circular channel supplying an individual film-cooling hole. The experimental results showed that the circular individual channels have 80% higher baseline overall effectiveness than the single rectangular channels without any film cooling. Ribbed turbulators without film cooling also increased the overall effectiveness by 21% for single rectangular channels and by 29% for the circular individual channels compared to the respective non-ribbed channels. While the film cooling increased the overall effectiveness of all geometries, the single rectangular channels had increased overall effectiveness levels by up to twice that of the no film-cooling case. On average, the single rectangular channels had an 80% improvement from film cooling, whereas the individual channel feeds, on average, had only a 50% improvement, given their high baseline effectiveness levels.

Engineering↗

Cooling of gas turbines IX : cooling effects from use of ceramic coatings on water-cooled turbine blades

The hottest part of a turbine blade is likely to be the trailing portion. When the blades are cooled and when water is used as the coolant, the cooling passages are placed as close as possible to the trailing edge in order to cool this portion. In some cases, however, the trailing portion of the blade is so narrow, for aerodynamic reasons, that water passages cannot be located very near the trailing edge. Because ceramic coatings offer the possibility of protection for the trailing part of such narrow blades, a theoretical study has been made of the cooling effect of a ceramic coating on: (1) the blade-metal temperature when the gas temperature is unchanged, and (2) the gas temperature when the metal temperature is unchanged. Comparison is also made between the changes in the blade or gas temperatures produced by ceramic coatings and the changes produced by moving the cooling passages nearer the trailing edge. This comparison was made to provide a standard for evaluating the gains obtainable with ceramic coatings as compared to those obtainable by constructing the turbine blade in such a manner that water passages could be located very near the trailing edge.

HEAT TRANSMISSION - METALS↗

Cooling effectiveness of slot injection into a turbulent boundary layer

The cooling effectiveness of injection through multiple flush slots at an angle of 10 deg was studied experimentally in a wind tunnel. Air was injected from one to four slots into a turbulent Mach 6 boundary layer. The slot mass flow ratio is defined, and data which describe the dependence of the cooling effectiveness on the slot mass flow ratio are presented. Experimental values are indicated graphically for various cases of single and multiple slot injection, where the total mass injection (i.e., the sum of flow rates from each slot) is the same for each case. The results show that, for a given coolant mass flow rate, thermal protection over the maximum surface area can be accomplished best by injecting the coolant flow through multiple slots.

Howard, F. G.↗

Experimental and computational study of the effect of shocks on film cooling effectiveness in scramjet combustors

This paper presents results from a study conducted to investigate the effect of incident oblique shocks on the effectiveness of a coolant film at Mach numbers, typical of those expected in a scramjet combustor at Mach 15 to 20 flight. Computations with a parabolic code are in good agreement with the measured pressures and heat fluxes, after accounting for the influence of the shock upstream of its point of impingement on the plate, and the expansion from the trailing edge of the shock generator. The test data shows that, for the blowing rates tested, the film is rendered largely ineffective by the shock. Computations show that coolant blowing rates five to ten times those tested are required to protect against shock-induced heating. The implications of the results to scramjet combustor design are discussed.

Kamath, Pradeep S.↗

Film-cooling effectiveness with developing coolant flow through straight and curved tubular passages

The data were obtained with an apparatus designed to determine the influence of tubular coolant passage curvature on film-cooling performance while simulating the developing flow entrance conditions more representative of cooled turbine blade. Data comparisons were made between straight and curved single tubular passages embedded in the wall and discharging at 30 deg angle in line with the tunnel flow. The results showed an influence of curvature on film-cooling effectiveness that was inversely proportional to the blowing rate. At the lowest blowing rate of 0.18, curvature increased the effectiveness of film cooling by 35 percent; but at a blowing rate of 0.76, the improvement was only 10 percent. In addition, the increase in film-cooling area coverage ranged from 100 percent down to 25 percent over the same blowing rates. A data trend reversal at a blowing rate of 1.5 showed the straight tubular passage's film-cooling effectiveness to be 20 percent greater than that of the curved passage with about 80 percent more area coverage. An analysis of turbulence intensity detain the mixing layer in terms of the position of the mixing interface relative to the wall supported the concept that passage curvature tends to reduce the diffusion of the coolant jet into the main stream at blowing rates below about. Explanations for the film-cooling performance of both test sections were made in terms differences in turbulences structure and in secondary flow patterns within the coolant jets as influenced by flow passage geometry.

Papell, S. S.↗

Numerical Investigation of Wall-Cooling Effect on Aero-Optical Distortions for Hypersonic Boundary Layer

Compressible wall-modeled large-eddy simulations of Mach 8 turbulent boundary-layer flows over a flat plate were carried out for the conditions of the hypersonic wind tunnel at Sandia National Laboratories. The simulations provide new insight into the effect of wall cooling on the aero-optical path distortions for hypersonic turbulent boundary-layer flows. Four different wall-to-recovery temperature ratios, 0.3, 0.48, 0.71, and 0.89, are considered. Despite the much lower grid resolution, the mean velocity, temperature, and resolved Reynolds stress profiles from the simulation for a temperature ratio of 0.48 are in good agreement with those from a reference direct numerical simulation. The normalized root-mean-square optical path difference obtained from the present simulations is compared with that from reference direct numerical simulations, Sandia experiments, as well as predictions obtained with a semi-analytical model by Notre Dame University. Here the present analysis focuses on the effect of wall cooling on the wall-normal density correlations, on key underlying assumptions of the aforementioned model such as the strong Reynolds analogy, and on the elevation angle effect on the optical path difference. Wall cooling is found to increase the velocity fluctuations and decrease the density fluctuations, resulting in an overall reduction of the normalized optical path distortion. Compared to the simulations, the basic strong Reynolds analogy overpredicts the temperature fluctuations for cooled walls. Also different from the strong Reynolds analogy, the velocity and temperature fluctuations are not perfectly anticorrelated. Finally, as the wall temperature is raised, the density correlation length, away from the wall but inside the boundary layer, increases significantly for beam paths tilted in the downstream direction.

42 ENGINEERING↗

Vortex-generating coolant-flow-passage design for increased film-cooling effectiveness and surface coverage

The thermal film-cooling footprints observed by infrared imagery for three coolant-passage configurations embedded in adiabatic-test plates are discussed. The configurations included a standard round-hole cross section and two orientations of a vortex-generating flow passage. Both orientations showed up to factors of four increases in both film-cooling effectiveness and surface coverage over that obtained with the round coolant passage. The crossflow data covered a range of tunnel velocities from 15.5 to 45 m/sec with blowing rates from 0.20 to 2.05. A photographic streakline flow visualization technique supported the concept of the counterrotating apability of the flow passage design and gave visual credence to its role in inhibiting flow separation.

Papell, S. S.↗

Computational and Experimental Study of Film-Cooling Effectiveness With and Without Downstream Vortex Generators

Downstream vortex generators that involve a pair of rectangular plates arranged in an open V-shape placed just downstream of each film-cooling hole were shown to create flow and vortical structures that entrain lifted film-cooling flow back to the surface and increase its lateral spreading on the surface (GT2020–14317). In this study, computations and measurements were performed to examine the flow mechanisms this vortex generator induces to improve film-cooling effectiveness of a flat plate with the cooling flow emanating from one row of inclined holes. Parameters studied include blowing ratio (BR = 0.75 and 1.0) and temperature ratio (TR = 1.07 and 1.9). Here, the computational study is based on steady Reynolds-averaged Navier–Stokes (RANS) closed by the shear-stress transport (SST) turbulence model with and without conjugate analysis. The experimental study was conducted by using a conjugate heat transfer test rig with a plenum, where cooling flow is introduced. Measurements made include velocity and temperature profiles upstream and downstream of the film-cooling holes as well as the temperature at several locations on the hot and cold sides of the film-cooled flat plate. The computational study was validated by comparing computed results with those from measurements at BR = 0.75 and 1.0 and TR = 1.9. Computational and experimental results are presented to show the effects of BR and TR on the flow structures and how those structures improve the effectiveness of film cooling with and without the downstream vortex generators and with and without conjugate heat transfer.

42 ENGINEERING↗

Dynamic metrics of natural ventilation cooling effectiveness for interactive modeling

The evaluation of natural ventilation potential for cooling indoor spaces during the early design phases is of great interest to researchers and practitioners. Among various definitions and usages for natural ventilation potential (NVP) in early design evaluation, this paper reviews and identifies the key performance indicators, and proposes two new dynamic metrics—natural ventilation cooling effectiveness (NVCE) and climate potential utilization ratio (CPUR). The metrics are dynamically responsive to various design options, in both steady and transient states, allowing consideration of thermal mass. Assisting in design development processes, the metrics quantify how well indoor spaces make use of natural ventilation’s cooling capacity. Case studies are presented to demonstrate how NVCE and CPUR enable designers to evaluate the predicted performance and how to apply the information to improve building design. Finally, the results of the design iterations showed that the relationship among various design parameters should be dynamically understood in order to evaluate the performance of natural ventilation, confirming that “the more the airflow, the greater the potential,” and “the heavier the thermal mass, the greater the energy saving” were not always true.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Joint optimization of land carbon uptake and albedo can help achieve moderate instantaneous and long-term cooling effects

Abstract Both carbon dioxide uptake and albedo of the land surface affect global climate. However, climate change mitigation by increasing carbon uptake can cause a warming trade-off by decreasing albedo, with most research focusing on afforestation and its interaction with snow. Here, we present carbon uptake and albedo observations from 176 globally distributed flux stations. We demonstrate a gradual decline in maximum achievable annual albedo as carbon uptake increases, even within subgroups of non-forest and snow-free ecosystems. Based on a paired-site permutation approach, we quantify the likely impact of land use on carbon uptake and albedo. Shifting to the maximum attainable carbon uptake at each site would likely cause moderate net global warming for the first approximately 20 years, followed by a strong cooling effect. A balanced policy co-optimizing carbon uptake and albedo is possible that avoids warming on any timescale, but results in a weaker long-term cooling effect.

54 ENVIRONMENTAL SCIENCES↗