Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling system efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal Analysis of Liquid and Air Cooling of High-Power-Density Integrated Motor Drives

Thermal management is a crucial aspect in the design of motor and drive systems. This paper introduces a coordinated cooling approach utilizing both liquid and air to enhance the integrated motor drive's power density. The proposed solution incorporates a shared water jacket to cool both the machine and power electronics, combined with forced air ventilation for the end windings and rotor. This approach is structurally simpler, less expensive, and more effective than conventional non-interacting cooling schemes. The paper addresses the modeling of key thermal features and nonlinearities including material anisotropy, contact thermal resistance, and uneven winding loss distributions. In addition, this study utilizes a more detailed model of the loss distribution among the winding turns in each slot that delivers a higher level of accuracy. Finite Element Analysis (FEA) results demonstrate the effectiveness of the integrated cooling system for efficiently cooling the designed integrated motor drive system.

42 ENGINEERING↗

Effectiveness-weighted control of cooling system components

Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

42 ENGINEERING↗

Effectiveness-weighted control of cooling system components

Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

Campbell, Levi A.↗

Clean Water Production in Cooling Towers

This project developed and demonstrated a novel technology that produces clean water from cooling tower recirculating water by using the natural evaporation and condensation cycle inside cooling towers. The system captures the escaping plume and converts blowdown quality water into high purity water suitable for on-site reuse such as boiler feed. The technology uses electric fields to ionize exhaust plumes, charge the entrained droplets, and direct them toward collection electrodes where they coalesce and flow downward. This allows water recovery at a low energy cost while reducing visible plume emissions. In addition, we developed a complementary software platform that improves overall cooling tower performance. The system uses wireless sensors and physics-based machine learning algorithms to optimize key parameters of the cooling process. For power generation facilities, this increases the thermal efficiency of the cooling loop and condenser, resulting in measurable cycle efficiency gains. Improvements of one percent or more can deliver significant increases in electricity production for the same fuel input.

01 COAL, LIGNITE, AND PEAT↗

Consumer Guide to Home Heating and Cooling

Learn about types of heating and cooling systems, system maintenance, and best practices for saving energy with your heating and cooling. This fact sheet from Energy Saver also includes information on buying a new heating or cooling system; efficiency ratings; and selecting new systems including air conditioners, heat pumps, and furnaces.

heating, cooling, air conditioners, heat pumps, fu↗

Manipulating Pore Topology and Functionality to Promote Fluorocarbon-Based Adsorption Cooling

With the worldwide demand for refrigeration and cooling expected to triple, it is increasingly important to search for alternative energy resources to drive the refrigeration cycles with reduced electricity consumption. Recently, adsorption cooling has gained increased attention since energy reallocation in such systems is based on gas adsorption/desorption, which can be driven by waste/natural heat sources. Eco-friendly sorption-based cooling relies on the cyclic transfer of refrigerant gas from a high to low energy state by the pseudo-compression effect resulting from adsorption and desorption. The driving force for energy transfer relies on heat rather than electricity. The performance of a sorption chiller is primarily influenced by this cyclic sorption behavior, which is characterized as the working capacity of the porous sorbent. Thus increases in this working capacity directly translate to a more compact and efficient cooling system. How-ever, a lack of highly effective sorbent/refrigerant pairs lowers cooling performance, and therefore has limited applicability. To this end, synthetic metal-organic frameworks (MOFs) and covalent organic polymers (COPs) possess higher porosity and greater tunability leading to more substantial potential benefits for adsorption, compared to traditional sorbent materials. Similarly, hydrofluorocarbon refrigerants have more favorable applicability given ease of operation above atmospheric pressures due to suitable saturated vapor pressures and boiling points. For these reasons, our work focuses on an ongoing strategy to promote sorption cooling via improvements in the sorbent/refrigerant pair. Specifically, we target the interaction of hydrofluorocarbon refrigerants with MOF/COP materials at a molecular level by interpreting the host-guest chemistry and the role of framework pore topology. These molecular level differences translate to cooling performance, which is described herein. These strategies include engineering framework porosity (i.e., pore size, pore volume) by using elongated organic linkers and stereochemistry control during synthesis; manipulating the sorb-ate/sorbent interaction by introducing functional moieties or unsaturated metal centers to enhance working capacities in narrow pressure ranges; varying pore topology/morphology to impact adsorption isotherm behavior; and leveraging defective sites within the frameworks to further enhance adsorption capability. Here this atomic level understanding of sorb-ate-sorbent interactions is conducted using various in situ experimental techniques such as synchrotron-based X-ray diffraction, X-ray absorption spectroscopy, in situ Fourier transform infrared spectroscopy, and direct sorption energies determinization with calorimetry. Moreover, the experimentally studied interactions and the corresponding adsorption mechanism are corroborated by computational studies using density functional theory (DFT) and grand canonical Monte Carlo (GCMC) simulations. Using this approach, we envision the capability to engineer designed frameworks with precise molecular control to target refrigerant molecules and thereby enhance the performance of desired working pairs for sorption-based cooling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advances in the Lightweight Air-Liquid Composite Heat Exchanger Development for Space Exploration Applications

An advanced, lightweight composite modular Air/Liquid (A/L) Heat Exchanger (HX) Prototype for potential space exploration thermal management applications was successfully designed, manufactured, and tested. This full-scale Prototype consisting of 19 modules, based on recommendations from its predecessor Engineering Development unit (EDU) but with improved thermal characteristics and manufacturability, was 11.2 % lighter than the EDU and achieves potentially a 42.7% weight reduction from the existing state-of-the-art metallic HX demonstrator. However, its higher pressure drop (0.58 psid vs. 0.16 psid of the metal HX) has to be mitigated by foam material optimizations and design modifications including a more systematic air channel design. Scalability of the Prototype design was validated experimentally by comparing manufacturability and performance between the 2-module coupon and the 19-module Prototype. The Prototype utilized the thermally conductive open-cell carbon foam material but with lower density and adopted a novel high-efficiency cooling system with significantly increased heat transfer contact surface areas, improved fabricability and manufacturability compared to the EDU. Even though the Prototype was required to meet both the thermal and the structural specifications, accomplishing the thermal requirement was a higher priority goal for this first version. Overall, the Prototype outperformed both the EDU and the corresponding metal HX, particularly in terms of specific heat transfer, but achieved 93.4% of the target. The next generation Prototype to achieve the specification target, 3,450W would need 24 core modules based on the simple scaling factor. The scale-up Prototype will weigh about 14.7 Kg vs. 21.6 Kg for the metal counterpart. The advancement of this lightweight composite HX development from the original feasibility test coupons to EDU to Prototype is discussed in this paper.

Shin, E. Eugene↗

Bubble Chamber Detectors with Light Nuclear Targets: A Snowmass 2021 White Paper

Neutrino cross sections are a critical ingredient in experiments that depend on neutrino scattering to reconstruct event kinematics and infer neutrino characteristics, like NOvA and T2K. An opportunity exists to reduce the 5-10% broad uncertainty on neutrino cross sections by producing more measurements of neutrino scattering from light nuclear targets at the relevant energies. Bubble chambers with light nuclear targets would be ideal for these measurements but the most recent device designed for use with an accelerator neutrino source is at least fifty years old. A new bubble chamber with light nuclear targets could be designed by observing how the technology has progressed for use in dark matter experiments and producing smaller modular devices that use more efficient cooling systems. A smaller modular device could also be designed for deployment to all functioning neutrino beams, but an investigation of the proper operating characteristics is necessary to adapt newer detectors to the structure of contemporary neutrino beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy Use in Quantum Data Centers: Scaling the Impact of Computer Architecture, Qubit Performance, Size, and Thermal Parameters

As quantum computers increase in size, the total energy used by a quantum data center, including the cooling, will become a greater concern. The cooling requirements of quantum computers, which operate at temperatures near absolute zero, are determined by computing system parameters, including the number and type of physical qubits, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. When combined with thermal system parameters such as cooling efficiency and cryostat heat transfer, the total energy use can be determined using a first-principles energy model. These models show that cooling of quantum computers differs in two fundamental ways from conventional data centers: (1) the energy required for cooling is much greater than the energy required for computation, and (2) the cooling loads are sensitive to the computational architecture. The temperature requirements for different qubit types can change energy requirements by orders of magnitude. Power use and computational power, as quantified by quantum volume, are analytically correlated. Approaches are identified for minimizing energy use in integrated quantum systems relative to computational power. Furthermore, designing a sustainable quantum computer will require both efficient cooling and system design that minimizes cooling requirements.

97 MATHEMATICS AND COMPUTING↗

MFVI Energy Efficiency Audit Training Module 3.1: Cooling Systems [Slides]

This slide deck is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This training module is focused on cooling systems. As such, it will assist its user in determining the optimal cooling system for a given space and then identifying the most efficient means of delivering that system.

21CPP↗

Ultra efficient turbo-compression cooling systems

Aspects of the present disclosure include a system for turbo-compression cooling. The system may be aboard a marine vessel. The system includes a power cycle and a cooling cycle. The power cycle includes a first working fluid, a waste heat boiler configured to evaporate the working fluid, a turbine, and a condenser. The condenser condenses the working fluid to a saturated or subcooled liquid. The cooling cycle includes a second working fluid, a first compressor configured to increase the pressure of the second working fluid, a condenser configured to condense the second working fluid to a saturated or subcooled liquid after exiting the first compressor, an expansion valve, and an evaporator. The turbine and first compressor are coupled one to the other. The waste heat boiler receives waste heat from engine jacket water and lubricating oil from a ship service generator. The evaporator cools water in a shipboard cooling loop.

Bandhauer, Todd M.↗

Reduced Energy Demand for Cooling with the Sky

This project demonstrated the use of SkyCool’s Passive Daytime Radiative Cooling panels to improve the energy efficiency of cooling systems at Ft Moore, GA. These panels work by passively emitting heat to the sky during the day even under direct sunlight.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Examination of an Orbiting Cryogenic Fuel Depot

For many years NASA has been interested in the storage and transfer of cryogenic fuels in space. Lunar, L2 and other chemical propulsive space vehicle missions now have staged refueling needs that a fuel depot would satisfy. The depot considered is located in lower earth orbit. Many considerations must go into designing and building such a station. Multi-layer insulation systems, thermal shielding and low conductive structural supports are the principal means of protecting the system from excessive heat loss due to boiloff. This study focuses on the thermal losses associated with storing LH2 in a passively cooled fuel depot in a lower earth equatorial orbit. The corresponding examination looks at several configurations of the fuel depot. An analytical model has been developed to determine the thermal advantages and disadvantages of three different fuel depot configurations. Each of the systems consists of three Boeing rocket bodies arranged in various configurations. The first two configurations are gravity gradient stabilized while the third one is a spin-stabilized concept. Each concept was chosen for self-righting capabilities as well as the fuel settling capabilities, however the purpose of this paper is to prove which of the three concepts is the most efficient passively cooled system. The specific areas to be discussed are the heating time from the fusion temperature to the vaporization temperature and the amount of boiloff for a specific number of orbits. Each of the previous points is compared using various sun exposed surface areas of the tanks.

Hull, Patrick V.↗

Hypersonic research engine project. Phase 2: Some combustor test results of NASA aerothermodynamic integration model

Combustor test results of the NASA Aerothermodynamic Integration Model are presented of a ramjet engine developed for operation between Mach 3 and 8. Ground-based and flight experiments which provide the data required to advance the technology of hypersonic air-breathing propulsion systems as well as to evaluate facility and testing techniques are described. The engine was tested with synthetic air at Mach 5, 6, and 7. The hydrogen fuel was heated to 1500 R prior to injection to simulate a regeneratively cooled system. Combustor efficiencies up to 95 percent at Mach 6 were achieved. Combustor process in terms of effectiveness, pressure integral factor, total pressure recovery and Crocco's pressure-area relationship are presented and discussed. Interactions between inlet-combustor, combustor stages, combustor-nozzle, and the effects of altitude, combustor step, and struts are observed and analyzed.

Sun, Y. H.↗

JT8D-15/17 High Pressure Turbine Root Discharged Blade Performance Improvement

The JT8D high pressure turbine blade and seal were modified, using a more efficient blade cooling system, improved airfoil aerodynamics, more effective control of secondary flows, and improved blade tip sealing. Engine testing was conducted to determine the effect of these improvements on performance. The modified turbine package demonstrated significant thrust specific fuel consumption and exhaust gas temperature improvements in sea level and altitude engine tests. Inspection of the improved blade and seal hardware after testing revealed no unusual wear or degradation.

Janus, A. S.↗

Energy efficiency based control for a cooling system

A method for controlling a cooling system based on a heat dissipation of an electronic module and an ambient air temperature includes determining a combination of individual controls on components of the cooling system that achieve a specific amount of cooling based on a cooling power relationship for the plurality of components, the heat dissipation of the electronic module and the ambient air temperature, and applying the individual controls to the plurality of components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency based control for a cooling system

A method for controlling a cooling system based on a heat dissipation of an electronic module and an ambient air temperature includes determining a combination of individual controls on components of the cooling system that achieve a specific amount of cooling based on a cooling power relationship for the plurality of components, the heat dissipation of the electronic module and the ambient air temperature, and applying the individual controls to the plurality of components.

Chainer, Timothy J.↗