Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling system efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal Analysis of Liquid and Air Cooling of High-Power-Density Integrated Motor Drives

Thermal management is a crucial aspect in the design of motor and drive systems. This paper introduces a coordinated cooling approach utilizing both liquid and air to enhance the integrated motor drive's power density. The proposed solution incorporates a shared water jacket to cool both the machine and power electronics, combined with forced air ventilation for the end windings and rotor. This approach is structurally simpler, less expensive, and more effective than conventional non-interacting cooling schemes. The paper addresses the modeling of key thermal features and nonlinearities including material anisotropy, contact thermal resistance, and uneven winding loss distributions. In addition, this study utilizes a more detailed model of the loss distribution among the winding turns in each slot that delivers a higher level of accuracy. Finite Element Analysis (FEA) results demonstrate the effectiveness of the integrated cooling system for efficiently cooling the designed integrated motor drive system.

42 ENGINEERING↗

Effectiveness-weighted control of cooling system components

Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

42 ENGINEERING↗

Effectiveness-weighted control of cooling system components

Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

Campbell, Levi A.↗

Clean Water Production in Cooling Towers

This project developed and demonstrated a novel technology that produces clean water from cooling tower recirculating water by using the natural evaporation and condensation cycle inside cooling towers. The system captures the escaping plume and converts blowdown quality water into high purity water suitable for on-site reuse such as boiler feed. The technology uses electric fields to ionize exhaust plumes, charge the entrained droplets, and direct them toward collection electrodes where they coalesce and flow downward. This allows water recovery at a low energy cost while reducing visible plume emissions. In addition, we developed a complementary software platform that improves overall cooling tower performance. The system uses wireless sensors and physics-based machine learning algorithms to optimize key parameters of the cooling process. For power generation facilities, this increases the thermal efficiency of the cooling loop and condenser, resulting in measurable cycle efficiency gains. Improvements of one percent or more can deliver significant increases in electricity production for the same fuel input.

01 COAL, LIGNITE, AND PEAT↗

Consumer Guide to Home Heating and Cooling

Learn about types of heating and cooling systems, system maintenance, and best practices for saving energy with your heating and cooling. This fact sheet from Energy Saver also includes information on buying a new heating or cooling system; efficiency ratings; and selecting new systems including air conditioners, heat pumps, and furnaces.

heating, cooling, air conditioners, heat pumps, fu↗

Manipulating Pore Topology and Functionality to Promote Fluorocarbon-Based Adsorption Cooling

With the worldwide demand for refrigeration and cooling expected to triple, it is increasingly important to search for alternative energy resources to drive the refrigeration cycles with reduced electricity consumption. Recently, adsorption cooling has gained increased attention since energy reallocation in such systems is based on gas adsorption/desorption, which can be driven by waste/natural heat sources. Eco-friendly sorption-based cooling relies on the cyclic transfer of refrigerant gas from a high to low energy state by the pseudo-compression effect resulting from adsorption and desorption. The driving force for energy transfer relies on heat rather than electricity. The performance of a sorption chiller is primarily influenced by this cyclic sorption behavior, which is characterized as the working capacity of the porous sorbent. Thus increases in this working capacity directly translate to a more compact and efficient cooling system. How-ever, a lack of highly effective sorbent/refrigerant pairs lowers cooling performance, and therefore has limited applicability. To this end, synthetic metal-organic frameworks (MOFs) and covalent organic polymers (COPs) possess higher porosity and greater tunability leading to more substantial potential benefits for adsorption, compared to traditional sorbent materials. Similarly, hydrofluorocarbon refrigerants have more favorable applicability given ease of operation above atmospheric pressures due to suitable saturated vapor pressures and boiling points. For these reasons, our work focuses on an ongoing strategy to promote sorption cooling via improvements in the sorbent/refrigerant pair. Specifically, we target the interaction of hydrofluorocarbon refrigerants with MOF/COP materials at a molecular level by interpreting the host-guest chemistry and the role of framework pore topology. These molecular level differences translate to cooling performance, which is described herein. These strategies include engineering framework porosity (i.e., pore size, pore volume) by using elongated organic linkers and stereochemistry control during synthesis; manipulating the sorb-ate/sorbent interaction by introducing functional moieties or unsaturated metal centers to enhance working capacities in narrow pressure ranges; varying pore topology/morphology to impact adsorption isotherm behavior; and leveraging defective sites within the frameworks to further enhance adsorption capability. Here this atomic level understanding of sorb-ate-sorbent interactions is conducted using various in situ experimental techniques such as synchrotron-based X-ray diffraction, X-ray absorption spectroscopy, in situ Fourier transform infrared spectroscopy, and direct sorption energies determinization with calorimetry. Moreover, the experimentally studied interactions and the corresponding adsorption mechanism are corroborated by computational studies using density functional theory (DFT) and grand canonical Monte Carlo (GCMC) simulations. Using this approach, we envision the capability to engineer designed frameworks with precise molecular control to target refrigerant molecules and thereby enhance the performance of desired working pairs for sorption-based cooling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bubble Chamber Detectors with Light Nuclear Targets: A Snowmass 2021 White Paper

Neutrino cross sections are a critical ingredient in experiments that depend on neutrino scattering to reconstruct event kinematics and infer neutrino characteristics, like NOvA and T2K. An opportunity exists to reduce the 5-10% broad uncertainty on neutrino cross sections by producing more measurements of neutrino scattering from light nuclear targets at the relevant energies. Bubble chambers with light nuclear targets would be ideal for these measurements but the most recent device designed for use with an accelerator neutrino source is at least fifty years old. A new bubble chamber with light nuclear targets could be designed by observing how the technology has progressed for use in dark matter experiments and producing smaller modular devices that use more efficient cooling systems. A smaller modular device could also be designed for deployment to all functioning neutrino beams, but an investigation of the proper operating characteristics is necessary to adapt newer detectors to the structure of contemporary neutrino beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy Use in Quantum Data Centers: Scaling the Impact of Computer Architecture, Qubit Performance, Size, and Thermal Parameters

As quantum computers increase in size, the total energy used by a quantum data center, including the cooling, will become a greater concern. The cooling requirements of quantum computers, which operate at temperatures near absolute zero, are determined by computing system parameters, including the number and type of physical qubits, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. When combined with thermal system parameters such as cooling efficiency and cryostat heat transfer, the total energy use can be determined using a first-principles energy model. These models show that cooling of quantum computers differs in two fundamental ways from conventional data centers: (1) the energy required for cooling is much greater than the energy required for computation, and (2) the cooling loads are sensitive to the computational architecture. The temperature requirements for different qubit types can change energy requirements by orders of magnitude. Power use and computational power, as quantified by quantum volume, are analytically correlated. Approaches are identified for minimizing energy use in integrated quantum systems relative to computational power. Furthermore, designing a sustainable quantum computer will require both efficient cooling and system design that minimizes cooling requirements.

97 MATHEMATICS AND COMPUTING↗

MFVI Energy Efficiency Audit Training Module 3.1: Cooling Systems [Slides]

This slide deck is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This training module is focused on cooling systems. As such, it will assist its user in determining the optimal cooling system for a given space and then identifying the most efficient means of delivering that system.

21CPP↗

Ultra efficient turbo-compression cooling systems

Aspects of the present disclosure include a system for turbo-compression cooling. The system may be aboard a marine vessel. The system includes a power cycle and a cooling cycle. The power cycle includes a first working fluid, a waste heat boiler configured to evaporate the working fluid, a turbine, and a condenser. The condenser condenses the working fluid to a saturated or subcooled liquid. The cooling cycle includes a second working fluid, a first compressor configured to increase the pressure of the second working fluid, a condenser configured to condense the second working fluid to a saturated or subcooled liquid after exiting the first compressor, an expansion valve, and an evaporator. The turbine and first compressor are coupled one to the other. The waste heat boiler receives waste heat from engine jacket water and lubricating oil from a ship service generator. The evaporator cools water in a shipboard cooling loop.

Bandhauer, Todd M.↗

Reduced Energy Demand for Cooling with the Sky

This project demonstrated the use of SkyCool’s Passive Daytime Radiative Cooling panels to improve the energy efficiency of cooling systems at Ft Moore, GA. These panels work by passively emitting heat to the sky during the day even under direct sunlight.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency based control for a cooling system

A method for controlling a cooling system based on a heat dissipation of an electronic module and an ambient air temperature includes determining a combination of individual controls on components of the cooling system that achieve a specific amount of cooling based on a cooling power relationship for the plurality of components, the heat dissipation of the electronic module and the ambient air temperature, and applying the individual controls to the plurality of components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficiency based control for a cooling system

A method for controlling a cooling system based on a heat dissipation of an electronic module and an ambient air temperature includes determining a combination of individual controls on components of the cooling system that achieve a specific amount of cooling based on a cooling power relationship for the plurality of components, the heat dissipation of the electronic module and the ambient air temperature, and applying the individual controls to the plurality of components.

Chainer, Timothy J.↗

Numerical Simulation of a Natural Convection–Driven Air-Cooled Reactor Cavity Cooling System Experiment

Ensuring the efficient removal of decay heat from the reactor vessel is essential for the safety of advanced reactor technologies. Several Generation-IV concepts incorporate variations in the reactor vessel cooling systems to achieve this objective. High-temperature gas-cooled reactors utilize a reactor cavity cooling system (RCCS), a passive ex-vessel system designed to operate without active components or external power during accident conditions. The RCCS removes decay heat primarily through radiative and convective heat transfer mechanisms. Here, this study presents a comprehensive validation of a computational fluid dynamics Reynolds-averaged Navier-Stokes model for the University of Wisconsin-Madison air-cooled RCCS facility. Validation was conducted for both high- and low-power natural convection cases under a uniform heating profile. Near-wall resolution was found to be critical for accurately modeling natural convection in the RCCS; employing an all-𝑦 + wall treatment resulted in wall temperature discrepancies exceeding 50 °⁢𝐶 compared to a wall-resolved mesh. Thermal-hydraulic behaviors under natural and forced convection conditions were compared within the heated cavity and RCCS. A turbulence model sensitivity analysis indicated that low-Reynolds number k-ɛ, k-ω shear stress transport (SST), and Reynolds stress transport models produce similar wall temperature predictions. A buoyancy modeling sensitivity study revealed that the Boussinesq approximation significantly underpredicted thermal-hydraulic behavior in the RCCS. Based on these findings, modeling recommendations are provided. The validated data set along with identified sensitivities refine the modeling of natural convection in the RCCS. The information produced by this study supports RCCS design, optimization, and safety evaluations, enabling the calibration and verification of reduced-order thermal-hydraulic models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techniques in performance and efficiency improvements of processors in a cooling system

Embodiments of the present disclosure describe methods, apparatuses, storage media, and systems for Thermal Design Power (TDP) rebalancing among thermally-coupled processors and non-thermally-coupled processors, providing computing efficiency or homogeneity with respect to, including but not limited to, thermal requirements, power consumption, and processor operations. The TDP rebalancing may include implementing management circuitry and configuration control circuitry. Other embodiments may be described and claimed.

Keceli, Fuat↗

The water use of data center workloads: A review and assessment of key determinants

The global importance of data center water use is increasing with the rapid growth of digitalization and artificial intelligence. This study analyzes the factors influencing workload-level water use, measured in liters consumed per workload, to guide water-saving strategies in data centers. Our findings reveal workload-level water use variations exceeding 10,000-fold, driven by over 1000-fold differences in water consumption per kilowatt hour of server electricity consumed and approximately 10-fold differences in server workload efficiency. Key determinants are ranked as server efficiency, electrical grid water consumption factors, server utilization, cooling system type, infrastructure efficiency, climate zone, inactive server percentage, and server refresh cycle. Notably, there is no single recipe for minimizing water use; instead, optimal outcomes depend on tailored combinations of these factors. This analysis addresses critical knowledge gaps by identifying the determinants of data center water use and exploring their achievable minima under diverse site-specific constraints.

Data centers↗