Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cornell University”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Geothermal Deep Direct-Use for Low-Carbon Heating: A Case Study at Cornell University

Cornell University is developing a geothermal deep direct-use system to provide reliable, low carbon, and cost-competitive heating for its main campus in Ithaca, New York. This geothermal system, also referred to as Earth Source Heat, would provide the majority of the campus heating load and represents a key pillar for the university to become carbon neutral by 2035. Over the last 10 years, numerous desktop, seismic, and geophysical studies have been undertaken at Cornell to characterize the local subsurface, predict long-term reservoir performance, design the integration into the existing district heating network, and estimate capital and levelized costs. Recently, the university received funding for drilling an observatory well to obtain in-situ subsurface data (e.g., reservoir temperatures, pressures, fluid chemistry, stress field), significantly lowering subsurface uncertainty and de-risking the project. Drilling of the test well is planned for fall 2021. This paper provides an overview and status of the project, including a summary of past studies and a description of the proposed well and planned testing activities.

Cornell University↗

EGS Reservoir Modeling for Developing Geothermal District Heating at Cornell University

Cornell University is pursuing development of an enhanced geothermal system (EGS) for providing heating to its main campus in Upstate New York. A ~10,000 ft (~3 km) deep vertical observation well ('CUBO') was drilled in 2022 to characterize the subsurface using wellbore logging, borehole imaging, fluid sampling, mini-frac tests, coring and drill cutting analysis. Down-hole temperatures measured at 3 km depth are about 80 degrees C, sufficiently high for direct-use heating. The well drilled through generally low porosity and low permeability Paleozoic sedimentary formations and into metamorphic basement rock, encountered at about 9,400 ft depth. Leveraging subsurface data obtained through CUBO, we investigated technical feasibility and design requirements of a doublet well system with horizontal laterals connected to a fracture network created through hydraulic fracturing. The EGS reservoir is sized to provide a nominal heat output in the range 5 to 10 MWth of continuous heating over a 15 year-lifetime with limited thermal drawdown. We applied the Gringarten Multiple parallel fracture model, the Cornell Discrete Fracture Simulator FOXFEM and the commercial simulator ResFrac to estimate required heat transfer area and design a potential hydraulic stimulation treatment. Reservoir simulations indicate that, depending on fluid flow rate and injection temperature, 2 to 3 km2 of effective fracture heat transfer area is required to supply the target heat output of 5 to 10 MWth over 15 years.

district heating↗

EGS Reservoir Modeling for Developing Geothermal District Heating at Cornell University: Preprint

Cornell University is pursuing development of an enhanced geothermal system (EGS) for providing heating to its main campus in Upstate New York. A ~10,000 ft (~3 km) deep vertical observation well ("CUBO") was drilled in 2022 to characterize the subsurface using wellbore logging, borehole imaging, fluid sampling, mini-frac tests, coring and drill cutting analysis. Down-hole temperatures measured at 3 km depth are about 80 degrees C, sufficiently high for direct-use heating. The well drilled through generally low porosity and low permeability Paleozoic sedimentary formations and into metamorphic basement rock, encountered at about 9,400 ft depth. Leveraging subsurface data obtained through CUBO, we investigated technical feasibility and design requirements of a doublet well system with horizontal laterals connected to a fracture network created through hydraulic fracturing. The EGS reservoir is sized to provide a nominal heat output in the range 5 to 10 MWth of continuous heating over a 15 year-lifetime with limited thermal drawdown. We applied the Gringarten Multiple parallel fracture model, the Cornell Discrete Fracture Simulator FOXFEM and the commercial simulator ResFrac to estimate required heat transfer area and design a potential hydraulic stimulation treatment. Reservoir simulations indicate that, depending on fluid flow rate and injection temperature, 2 to 3 km2 of effective fracture heat transfer area is required to supply the target heat output of 5 to 10 MWth over 15 years.

district heating↗

A Co-Investigator Proposal for the Cornell University CAPER Rocket: Cleft Accelerated Plasma Experiment Rocket

The objectives are: 1) To support the Cornell wave instruments in a study of dayside ion outflow. 2) In conjunction with the U. of Alaska ground optical data, a prime objective was to measure the topside Cusp ion spectra responsible for dayside proton aurora. If such a correlative measurement could be made, then monitoring of this cusp precipitation from the ground could be routinely achieved. The nature of Cusp ions has and will continue to provide information about dayside magnetic reconnection. 3) A third objective was to study the dayside microburst electron precipitation from the BPS/CPS population. The Scifer rocket flight showed a bursty electron population at 1000 km altitude correlated closely with pulsation ground aurora on closed field lines. The frequency of this pulsating aurora is about 1 Hz. Ground pulsation measurements have recorded dayside bursts of Pc1 waves which could very well be the source of the electrons responsible for the pulsating aurora. In support of the Caper flight, UNH provided ground induction antennas to measure the equatorial Pc1 waves that might be dumping trapped electrons from the Central Plasma Sheet population. The Caper flight was launched on the last day of the window and all the Cornell and UNH instrumentation worked perfectly. Unfortunately the rocket trajectory flew very far to the west of the ground site at Longyearbyen missing conjugacy by several hundred kilometers. This meant the intended aurora was not crossed and all the ground experiments were far from being near the foot print of the rocket ruling out correlative science. The "miss" was primarily due to a decision during the countdown by the Andoya Rocket Range to move the azimuth of the rocket to the west to avoid Norwegian fishing boats at the splash point of the first two stages, and to make matters worse, the dispersion of the fourth stage of the rocket added entirely in this direction. Although no publications have resulted from the UNH data up to this point, a joint publication with the U. of Alaska group using both the Scifer and Caper data is in preparation. The data will continue to be worked on. There is interest in the Caper data as evidence by two recent papers presented at the "Low Latitude Boundary Layer Chapman Conference" held in New Orleans, Louisiana in April 2001.

Arnoldy, Roger L.↗

AWAKEN Site A1 HALO XR Lidar (Cornell University) / Raw Data

These data are scanning Doppler lidar measurements from the deployment of a HALO XR at AWAKEN site A1. The measurements include calibrated beam azimuth angles, radial velocity, backscatter, signal to noise ratio per each line of sight, and range-gate.

17 WIND ENERGY↗

AWAKEN Site H HALO XR Lidar (Cornell University) / Raw Data

These data are scanning Doppler lidar measurements from the deployment of a HALO XR at AWAKEN site H. The measurements include calibrated beam azimuth angles, radial velocity, backscatter, signal to noise ratio per each line of sight, and range-gate.

17 WIND ENERGY↗

Cornell University remote sensing program

The major activities of the program staff from December 1, 1973 to May 31, 1974 are reported and include: (1) communication and instruction; (2) data and facilities; (3) research completed; (4) research in progress; (5) selected correspondence; (6) grant sponsored travel; and (7) seminars and newsletters. Detailed information and maps are given for the following selected projects: (1) ERTS mapping of waterways in the Tug Hill region of New York State; (2) photo-archeological investigation of Great Gully, New York; and (3) evaluation of selected highway impacts using aerial photography.

Liang, T.↗