Search NASA⌕ Search

SEARCH · Search NASA

Results for “Counter-current flow limitation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Semi-Empirical Correlation for Counter-Current Flow Limitation in a Vertical Pipe

Counter-current two-phase flows may take place in the steam generator of a pressurized water reactor (PWR) during a reflux-cooling mode. Therefore developing reliable correlations of counter-current flow limitation (CCFL) is of great importance in safety analyses. Wallis derived a CCFL correlation, which is expressed in terms of the so-called Wallis parameters, which are the dimensionless gas and liquid volumetric fluxes. Although effects of the fluid properties are not sufficiently accounted for in this correlation, he introduced the inverse liquid viscosity number into it to account for the viscous effect on CCFL . The functional form of the factor for the viscous effect was however empirically determined without physical grounds. Zapke and Kroeger proposed an empirical CCFL correlation by introducing the Ohnesorge number into the original Wallis correlation to account for the effects of the liquid viscosity and surface tension on CCFL. The effects of the fluid properties have been thus added in the original Wallis correlation in an empirical manner. In this study, a semi-empirical correlation for CCFL in a vertical pipe is derived from one-dimensional equations for a steady counter-current annular two-phase flow in a vertical pipe. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Counter-Current Flow Limitation Studies in Complex Geometries Utilizing Interface Capturing Simulations Coupled with PID Flow Rate Controller

In nuclear thermal-hydraulic studies, counter-current flow limitation (CCFL) typically refers to steam rising at a fast rate such that it prevents coolant from draining down within a confined channel. CCFL is a crucial issue in nuclear reactor safety analysis. This study investigates CCFL in debris bed channels using high-resolution interface-capturing simulations. A novel proportional-integral-derivative flow rate controller is developed to efficiently achieve the CCFL conditions. Verification studies confirm that CCFL occurs under the same conditions with or without the controller, demonstrating that PID control ensures accurate prediction. Three debris bed channel geometries were examined: a cylindrical channel, a channel with small obstacles, and a channel with large obstacles. Results show that obstacles significantly impact flow behavior, interfacial shear, wall shear, and pressure gradients required for CCFL. Furthermore, the comparison with experimental data confirmed that simulations incorporating geometric complexities align more closely with experimental CCFL conditions. A pressure gradient correlation was also developed for CCFL prediction.

Counter-current flow limitation↗

Scaling ability of the counter-current flow limitation (CCFL) correlations for application to reactor thermal hydraulics

The limitation of gas-liquid counter-current flow is important for getting coolant to the core preventing heat-up. To illustrate the scaling dependence of counter-current flow in the downcomer, the upper core tie plate and the hot leg, some results are presented. Based on a derivation of the counter-current flow equations for vertical and horizontal flows, the scaling ability of existing correlations is shown for homogeneous vertical counter-current flow (Kutateladze-type equation) and separated horizontal flow in the hot leg during reflux-condenser conditions (Wallis equation). The large reactor scale heterogeneous counter-current flow in the downcomer and at the upper core tie-plate needed an extension of the Kutateladze-type equation. Finally, Bankoff suggested that for CCFL in perforated plates such as upper tie plate, a parameter that is a combination of actual length scale (Wallis parameter) and Laplace constant (Kutateladze parameter) will be required.

36 MATERIALS SCIENCE↗

Statistical relationship between metabolic decomposition and chemical uptake predicts bioconcentration factor data for diverse chemical exposures

Background: A challenge of in vitro to in vivo extrapolation (IVIVE) is to predict the physical state of organisms exposed to chemicals in the environment from in vitro exposure assay data. Although toxicokinetic modeling approaches promise to bridge in vitro screening data with i Danio rerio ) based upon particle swarm optimizations (PSO) of the chemical uptake and degradation rates that predict bioconcentration factors (BCF) for a broad range of chemicals. PSO reveals a relationship between chemical uptake and decomposition parameter values that predicts chemical-specific BCF values with moderate statistical agreement to a limited yet diverse chemical dataset, and all without a need to retrain the model to new data. Conclusions: The presented model requires only the octanol-water partitioning ratio to predict BCFs to a fidelity consistent with existing QSAR models. This success begs re-evaluation of the modeling assumptions; specifically, it suggests that chemical uptake into arterial blood may be limited by transport across gill membranes (diffusion) rather than by counter-current flow between gill lamellae (convection). Therefore, more detailed molecular modeling of aquatic respiration may further improve predictive accuracy of the rTK approach.

59 BASIC BIOLOGICAL SCIENCES↗

Permeability evolution of shale during spontaneous imbibition

Shales have small pore and throat sizes ranging from nano to micron scales, low porosity and limited permeability. The poor permeability and complex pore connectivity of shales pose technical challenges to (a) understanding flow and transport mechanisms in such systems and, (b) in predicting permeability changes under dynamic saturation conditions. This paper presents quantitative experimental evidence of the migration of water through a generic shale core plug using micro CT imaging. In addition, in-situ measurements of gas permeability were performed during counter-current spontaneous imbibition of water in nano-darcy permeability Marcellus and Haynesville core plugs. It was seen that water blocks severely reduced the effective permeability of the core plugs, leading to losses of up to 99.5% of the initial permeability in experiments lasting 30 days. There was also evidence of clay swelling which further hindered gas flow. When results from this study were compared with similar counter-current gas permeability experiments reported in the literature, the initial (base) permeability of the rock was found to be a key factor in determining the time evolution of effective gas permeability during spontaneous imbibition. With time, a recovery of effective permeability was seen in the higher permeability rocks, while becoming progressively detrimental and irreversible in tighter rocks. Finally, these results suggest that matrix permeability of ultra-tight rocks is susceptible to water damage following hydraulic fracturing stimulation and, while shut-in/soaking time helps clearing-up fractures from resident fluid, its effect on the adjacent matrix permeability could be detrimental.

04 OIL SHALES AND TAR SANDS↗

Revisiting low-fidelity two-fluid models for gas–solids transport

Two-phase gas–solids transport models are widely utilized for process design and automation in a broad range of industrial applications. Some of these applications include proppant transport in gaseous fracking fluids, air/gas drilling hydraulics, coal-gasification reactors and food processing units. Systems automation and real time process optimization stand to benefit a great deal from availability of efficient and accurate theoretical models for operations data processing. However, modeling two-phase pneumatic transport systems accurately requires a comprehensive understanding of gas–solids flow behavior. In this study we discuss the prevailing flow conditions and present a low-fidelity two-fluid model equation for particulate transport. The model equations are formulated in a manner that ensures the physical flux term remains conservative despite the inclusion of solids normal stress through the empirical formula for modulus of elasticity. A new set of Roe–Pike averages are presented for the resulting strictly hyperbolic flux term in the system of equations, which was used to develop a Roe-type approximate Riemann solver. The resulting scheme is stable regardless of the choice of flux-limiter. The model is evaluated by the prediction of experimental results from both pneumatic riser and air-drilling hydraulics systems. We demonstrate the effect and impact of numerical formulation and choice of numerical scheme on model predictions. We illustrate the capability of a low-fidelity one-dimensional two-fluid model in predicting relevant flow parameters in two-phase particulate systems accurately even under flow regimes involving counter-current flow.

42 ENGINEERING↗

Thermodynamic Limits of Redox-Based Thermochemical Processes (REDOTHERM)

Solar thermochemical fuel production is a potential pathway for the production of sustain liquid drop-in fuels, which can help decarbonize the aviation and maritime sectors. In an attempt to analyze the commercial viability of this technology, several studies have been conducted, including system and technoeconomic analysis (TEA) modeling. However, most studies to date simply assume a given redox reactor efficiency, which is significantly higher than demonstrated values to date. While it is widely recognized that utilizing a counter-current flow (CF) configuration could increase the redox reactor efficiency, an over-simplification in the thermodynamic modeling may lead to unphysical results which has been included in multiple publications. The fact that the solar redox reactor is the least developed component in the process chain makes it hard to identify technology gaps and evaluate pathways to deployment at scale using this approach. In this work, a thermodynamic model for a moving oxide system has been developed, in a general form that allows to analyze the system for different redox-active materials, under a wide range of operating conditions, for both parallel and countercurrent flows. The model capabilites are demonstrated, and the model's code will be shared as an open-source on GitHub in the next few months.

chemical looping↗

Controlling kinetic and diffusive length-scales during absorptive hydrogen removal in methane dehydroaromatization on MoC x /H-ZSM-5 catalysts

Addition of Zr metal absorbent to MoC x /H-ZSM-5 in the form of staged-bed, stratified-bed, and interpellet physical mixtures effectively scavenges H 2 from catalyst proximity, enhancing maximum single-pass benzene + naphthalene yield during methane dehydroaromatization (DHA) reactions to 14-16% compared to 8% in formulations without zirconium. The coupling of spatially-distinct catalytic and absorptive functions is achieved by dispersive/diffusive transport which conveys H 2 to staged Zr both co- and counter-current to bulk advection, thereby suppressing axial H 2 partial pressure profiles along the catalyst bed and enhancing net aromatization rates. We evince hitherto unreported significance of dispersive hydrogen transport during methane DHA by measurement of Péclet number, Pe = 1.32, in H 2 tracer studies with step-change or impulse input to inert catalyst proxies. Kinetic limits to methane pyrolysis are quantified by Damköhler number, Da, for synthesis of benzene, Da B = 0.15, and naphthalene, Da N = 0.03, determined from kinetic studies which rigorously account for reversibility of DHA reactions. Here, detailed reaction-transport models synthesize interplay of kinetic, diffusive, and convective length-scales captured by Péclet and Damköhler number to predict influence of catalyst-absorbent proximity and process flow-conditions on aromatization rates. Systematic control of catalyst bed-length, L, or linear flow velocity, u, predictably alters Pe and Da to effect improvements in methane conversion with and without Zr metal, corroborating results from simulation of the reaction-transport model.

03 NATURAL GAS↗

Meta-metallic coils and resonators: Methods for high Q-value resonant geometries

A novel method of decreasing ohmic losses and increasing Q-value in metallic resonators at high frequencies is presented. The method overcomes the skin-depth limitation of rf current flow cross section. The method uses layers of conductive foil of thickness less than a skin depth and capacitive gaps between layers. The capacitive gaps can substantially equalize the rf current flowing in each layer, resulting in a total cross-sectional dimension for rf current flow many times larger than a skin depth. Analytic theory and finite-element simulations indicate that, for a variety of structures, the Q-value enhancement over a single thick conductor approaches the ratio of total conductor thickness to skin depth if the total number of layers is greater than one-third the square of the ratio of total conductor thickness to skin depth. The layer number requirement is due to counter-currents in each foil layer caused by the surrounding rf magnetic fields. We call structures that exhibit this type of Q-enhancement “meta-metallic.” In addition, end effects due to rf magnetic fields wrapping around the ends of the foils can substantially reduce the Q-value for some classes of structures. Foil structures with Q-values that are substantially influenced by such end effects are discussed as are five classes of structures that are not. We focus particularly on 400 MHz, which is the resonant frequency of protons at 9.4 T. Simulations at 400 MHz are shown with comparison to measurements on fabricated structures. The methods and geometries described here are general for magnetic resonance and can be used at frequencies much higher than 400 MHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using the Carbon Capture Simulation Initiative (CCSI) Tool to Design the Experiments in the Parametric Campaign of a Novel Compact Absorber for Carbon Capture

Gas absorption towers with structured packing and solvent have been used for Carbon Dioxide (CO 2 ) Capture for about many decades. To overcome process limitations and practical disadvantages for CO 2 capture from the stationary emitter (e.g. NG and coal power plant), many new designs have been proposed and explored at the various scales in the last decade with aim of either low energy penalty or low capital cost. To reduce the size of the absorption tower and hence the total cost of CO 2 capture, the University of Kentucky Center for Applied Energy Research Center (UK CAER) has designed and built a novel CO 2 capture absorption tower or Compact Absorber, integrated into an existing large-bench scale CO 2 capture unit. The Compact Absorber has three sections. The top of the column is a fogging section where the solvent is sprayed through a nozzle producing droplets flowing downward in a co-current fashion with the flue gas. The center of the column is a frothing section where the solvent and flue gas flow through regenerative frothing screens designed by Industrial Climate Solutions, Inc. The bottom of the column is a typical structured packing section were the flue gas and solvent flow in a counter-current fashion. The parametric campaign will be conducted in order to optimize the operating parameters for CO 2 capture including liquid/gas ratio, lean loading, and temperature, liquid residence time. A simulated flue gas with 14% CO 2 will be used along with a UK CAER developed proprietary solvent. The 100-hour parametric campaign is designed using a statistical approach of the Sequential Design of Experiments (sDOE). sDOE is one of the CCSI tools that provides an adaptive statistical approach for designing future experiments based on the results of previous experiments. Application of a typical DOE provides the user with the minimum number of experiments required to get the same data, but sDOE allows the user to make an informed choice of experiments based on the results of previous experiments. The complete absorption column has been constructed and has been partially commissioned. Initial data has been collected by operating using the fogging section and the frothing section. The fogging section produces solvent droplets of about 100 μm sauter mean diameter and as small as 25 μm using a hydraulic nozzle by BETE. The frothing section produces bubbles of about 5mm with high mixing of solvent promoting the higher mass transfer from gas to liquid. The absorber reaches the capture efficiency of about 50% with only two sections in operation. Based on the current results, it can be deduced that increasing the solvent feed temperature and including the packed section for absorption the capture efficiency will increase further. Initial data will be collected using all three sections of the absorber and will be used for sDOE. Non-Uniform Space Filling model of sDOE will be used to prioritize the input conditions resulting into maximum capture efficiency. sDOE is performed using the platform called Framework Optimization, Quantification of Uncertainty, and Surrogates (FOQUS). The method and results demonstrating the progress of the parametric campaign from the initial set of experiments to the final stage of obtaining optimized parameters using sDOE tool will be presented in detail.

20 FOSSIL-FUELED POWER PLANTS↗