Benchmarking at the National Criticality Experiments Criticality Experiments Research Center (NCERC) [Slides]
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Critical experiment for cavity reactor using gaseous uranium hexafluoride core configuration
Criticality experiments using spherical gas core to provide benchmark results for cold conditions of typical nuclear rocket concept
Critical mass of uranium 235 for stainless steel lined cavities in nuclear research and test reactors with heavy water reflector
In October 2010 a series of benchmark experiments was conducted at the Commissariat a Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE [1] facility. These experiments were a joint effort between the US Department of Energy (DOE) and the French CEA. The purpose of these experiments was to create three benchmarks for the verification and validation of radiation transport codes and evaluated nuclear data used in the analysis of criticality accident alarm systems (CAASs). This presentation will discuss the geometric configuration of these experiments and the quantities that were measured and will present some preliminary comparisons between the measured data and calculations. This series consisted of three single-pulsed experiments with the SILENE reactor. During the first experiment the reactor was bare (unshielded), but during the second and third experiments it was shielded by lead and polyethylene, respectively. During each experiment several neutron activation foils and thermoluminescent dosimeters (TLDs) were placed around the reactor, and some of these detectors were themselves shielded from the reactor by high-density magnetite and barite concrete, standard concrete, and/or BoroBond. All the concrete was provided by CEA Saclay, and the BoroBond was provided by Y-12 National Security Complex. Figure 1 is a picture of the SILENE reactor cell configured for pulse 1. Also included in these experiments were measurements of the neutron and photon spectra with two BICRON BC-501A liquid scintillators. These two detectors were provided and operated by CEA Valduc. They were set up just outside the SILENE reactor cell with additional lead shielding to prevent the detectors from being saturated. The final detectors involved in the experiments were two different types of CAAS detectors. The Babcock International Group provided three CIDAS CAAS detectors, which measured photon dose and dose rate with a Geiger-Mueller tube. CIDAS detectors are currently in use at Y-12 in the newly constructed Highly Enriched Uranium Materials Facility. The second CAAS detector used a 6 LiF TLD to absorb neutrons and a silicon detector to count the charge particles released by these absorption events. Lawrence Livermore National Laboratory provided four of these detectors, which had formerly been used at the Rocky Flats facility in the United States.
Over the years, significant validation work for the neutronics code MPACT has been performed against zero-power critical benchmarks and measured data from operating nuclear power plants. As a part of the Modeling and Analysis of Exelon BWRs for Eigenvalue and Thermal Limits Predictability project, new validation efforts relevant to boiling water reactor (BWR) core applications have been performed. This paper presents the results of the critical experiment portion of the BWR validation efforts for MPACT. The Kritz-4 experiments and IPEN/MB-01 BWR-relevant configurations are modeled with MPACT. The Kritz-4 BWR critical experiments were performed at both cold and hot conditions, which is a unique feature among other critical experiment facilities. The MPACT results with linear source (LS) Method of Characteristics (MOC) have very good agreement with the measured criticality. When using the 60-group BWR library with LS and P2 scattering, the maximum k{sub eff} error is 109 pcm, and the average cold-hot bias is only -0.11 pcm/K. The fission rate distributions of MPACT are also verified with Serpent calculations. For the IPEN facility, two configurations are considered: one with a large central void, and one with a cruciform control rod. The MPACT k{sub eff} errors are less than 50 pcm for all IPEN problems. (authors)
Sandia National Laboratories and the Institut de Radioprotection et de Sûreté Nucléaire have collaborated on the design and execution of a set of critical experiments that explore the effects of molybdenum in water-moderated fuel-rod arrays. The molybdenum was included as sleeves on some of the fuel rods in the critical experiment fuel arrays. Approach-to-critical experiments were performed on five configurations of fuel and molybdenum sleeves using the 7uPCX fuel in core hardware that set the triangular fuel rod pitch at 15.494 mm. The experiments are evaluated as benchmark critical experiments for the 2023 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook as LEU-COMP-THERM-111.
This presentation is on the Molybdenum (Mo) sleeve experiments at the Sandia Critical Experiments Facility. The Institut de Radioprotection et de Sûreté Nucléaire (IRSN) performed the preliminary design of the experiment. IRSN performed the final nuclear design of the experiment. Sandia performed the detailed design of the experiment to make it work in the critical assembly and Sandia also oversaw the fabrication and installation of the hardware. The slides include cutaway and overall views and a look into the results.
A critical experiment with spherical symmetry has been conducted on the gas core nuclear reactor concept. The nonspherical perturbations in the experiment were evaluated experimentally and produce corrections to the observed eigenvalue of approximately 1% delta k. The reactor consisted of a low density, central uranium hexafluoride gaseous core, surrounded by an annulus of void or low density hydrocarbon, which in turn was surrounded with a 97-cm-thick heavy water reflector.
The Los Alamos Critical Experiments Facility (LACEF) and subsequently its descendant, the National Criticality Experiments Research Center (NCERC) located at the Nevada National Security Site, have been performing critical experiments for over 75 years. The work done continues to build upon lessons learned from the past. It also builds upon knowledge gained from past experiments. The LACEF and NCERC experiments “provide nuclear criticality benchmark data for a wide variety of fissile and non-fissile materials in all neutron energy spectra systems”. In 2014, a subcritical benchmark with plutonium surrounded by nickel was issued in the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Two years later, a new benchmark experiment was performed, commonly known as Subcritical Copper Reflected $\mathcal{a}$-Phase Plutonium SCR$\mathcal{a}$P. The uncertainties in the SCR$\mathcal{a}$P experiment were significantly reduced from the Pu-Ni experiment and the methods were refined. Additionally, a Pu-lead critical experiment was performed in 2017 which followed different methods and with different objectives. Now, an experiment is proposed that builds on both the subcritical nickel experiment and the critical lead experiment. The proposed experiment has interleaved nickel and plutonium, in a thermal arrangement. This particular experiment would support criticality safety at the Hanford Tank Farms, whose tanks contain a significant amount of nickel credited as a neutron absorber in the criticality safety evaluation.
Explore the source record for details and available documents.
Nuclear criticality safety evaluations commonly take credit for neutron-absorbing materials. The normal practice for validating the calculational process to develop safety limits and margins of safety is to compare the safety case models with calculations of various critical experiments of a similar composition. Because there is a lack of critical experiments with various relevant neutron-absorbing materials mixed with fissile material, a new approach is being developed. This new approach uses small amounts of these credited materials in a critical assembly and assesses their worth and neutron energy spectral characteristics using absorption reaction rates. This approach is proposed as a new method for nuclear data validation. The assessment will involve measured central reactivity worth in a critical or near-critical assembly and subsequent comparison with calculated values from Monte Carlo computer analyses. Additionally, four configurations are proposed which replace fuel rods in the driver region with absorber rods. These configurations will allow for examination of the effects of the material in a more thermalized spectrum experiment selection in these scenarios. This paper presents some case studies examining the impact of these changes on some hypothetical safety analysis systems.This paper documents the detailed design portion of the critical experiment design process, focusing on development of a capability to test epithermal/ intermediate energy cross sections for materials using the 7uPCX critical experiment facility. Tantalum is specified as the test material to be examined.
A new critical experiment has been performed on the Planet vertical assembly machine at the National Criticality Experiments Research Center (NCERC). The purpose of the experiment was to compare the moderator properties of polyethylene versus Lucite and to use the experiment as an instructional tool for criticality safety engineers. The Lucite version of this experiment has been performed many times since the mid-1970's. Similar to the Lucite critical experiment, the polyethylene experiment was designed to emphasize the factors that affect criticality; namely, enrichment, reflection, interaction, moderation, mass, shape, volume, density, concentration, and poisons. The critical mass obtained with the moderating high density polyethylene plates was 997.0 ± 0.65 grams of highly enriched uranium, which is approximately 34% lower than the critical mass obtained using the Lucite moderating plates. This 34% decrease is mostly attributable to the higher hydrogen and carbon atom densities of polyethylene versus Lucite. (authors)
Not provided.
Abstract not provided.
A critical experiment was performed to provide nuclear data in a non-thermal neutron spectrum and to reestablish experimental capability relevant to Stockpile Stewardship and Technical Nuclear Forensic programs. Irradiation foils were placed at specific locations in the Zeus all oralloy critical experiment to obtain fission ratios. These ratios were compared with others from other critical assemblies to assess the degree of softness in the neutron spectrum. This critical experiment was performed at the National Criticality Experiments Research Center (NCERC) in Nevada.
Integral subcritical and critical experiments are essential in providing validation of computational codes which improve confidence in the predicted k eff results of specific applications. This work discusses the relevance of existing integral subcritical and critical experiments to applications far reaching across the nuclear complex. These applications include Travelling Wave Reactors (TWR), Kilopower Reactor Using Stirling Technology (KRUSTY), and plutonium reflected by tantalum. The primary goal of this work is to improve knowledge of energy-dependent cross-section sensitivities for specific applications, identify nuclear data gaps in existing experiments, enable an optimized design of new experiments to address these gaps, and design practical new experiments that could be executed at the National Criticality Experiments Research Center (NCERC) that have a high-value to these applications.