Search NASA⌕ Search

SEARCH · Search NASA

Results for “Critical exponents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Critical exponent for viscosity

The critical exponent y characterizing the divergence of the viscosity for carbon dioxide and xenon has been measured. The values of y for both fluids fall within the range y = 0.041 + or - 0.001 and are consistent with the range y = 0.042 + or - 0.002 spanned by earlier data for four binary liquid mixtures. This agreement is the strongest evidence that pure fluids and binary liquids are in the same dynamic universality class; however, the results for y are inconsistent with the recent theoretical value of 0.032.

Berg, Robert F.↗

Critical exponents and scaling relations for self-organized critical phenomena

Critical indices beta, gamma delta, nv, etc. are defined and calculated for self-organized critical phenomena. Scaling relations are derived and checked numerically. The order-parameter exponent beta describes the spontaneous current and the relaxation to the criticl point. The power spectrum has 'l/f' behavior with the exponent phi = nv x z, where z is the dynamical critical exponent.

Tang, Chao↗

The susceptibility critical exponent for a nonaqueous ionic binary mixture near a consolute point

We report turbidity measurements of a nonaqueous ionic solution of triethyl n-hexylammonium triethyl n-hexylboride in diphenyl ether. A classical susceptibility critical exponent gamma = 1.01 +/- 0.01 is obtained over the reduced temperature range t between values of 0.1 and 0.0001. The best fits of the sample transmission had a standard deviation of 0.39 percent over this range. Ising and spherical model critical exponents are firmly excluded. The correlation length amplitude xi sub 0 from fitting is 1.0 +/- 0.2 nm which is much larger than values found in neutral fluids and some aqueous binary mixtures.

Zhang, Kai C.↗

Critical exponent for the viscosity of carbon dioxide and xenon

The viscosities of carbon dioxide and xenon have been measured near their critical points and the critical exponent y characterizing the asymptotic divergence has been determined. Both fluids yielded exponents in the range y = 0.041 + or - 0.001 and thus also fell in the range y = 0.042 + or - 0.002 from an earlier study of four binary liquids. This agreement between experiments is the first evidence that pure fluids and binary liquids are in the same dynamic universality class. A recent theoretical value for y is 0.032. The 30 percent discrepancy is much greater than the combined errors from experiment and theory. The torsion oscillator viscometer operated at low frequency and low shear rate to avoid systematic errors caused by critical slowing down. Far from T(c) the analysis accounted for the crossover from critical to noncritical temperature dependence, where the latter was obtained from previously published correlations. Corrections for gravitational stratification were included close to T(c).

Berg, R. F.↗

Critical exponent for the viscosity of four binary liquids

The viscosity of the following binary mixtures was measured near their consolute points: (1) methanol + cyclohexane, (2) isobutyric acid + water, (3) nitroethane + 3-methylpentane, and (4) 2-butoxyethanol + water. It is shown that the multiplicative hypothesis is valid for these mixtures. It is also found that the concentration closest to critical has the largest viscosity enhancement.

Berg, Robert F.↗

Turbidity of a binary fluid mixture: Determining eta

A ground based (1-g) experiment is in progress that will measure the turbidity of a density-matched, binary fluid mixture extremely close to the critical point. By covering the range of reduced temperatures t is equivalent to (T-T(sub c))/T(sub c) from 10(exp -8) to 10(exp -2), the turbidity measurements will allow the critical exponent eta to be determined. No experiment has determined a value of the critical exponent eta, yet its value is significant to theorists in critical phenomena. Interpreting the turbidity correctly is important if future NASA flight experiments use turbidity as an indirect measurement of relative temperature in shuttle experiments on critical phenomena in fluids.

Jacobs, Donald T.↗

Turbidity of a Binary Fluid Mixture: Determining Eta

A ground based (1-g) experiment is in progress that will measure the turbidity of a density-matched, binary fluid mixture extremely close to its liquid-liquid critical point. By covering the range of reduced temperatures t equivalent to (T-T(sub c)) / T(sub c) from 10(exp -8) to 10(exp -2), the turbidity measurements will allow the critical exponent eta to be determined. No experiment has precisely determined a value of the critical exponent eta, yet its value is significant to theorists in critical phenomena. Relatively simple critical phenomena, as in the liquid-liquid system studied here, serve as model systems for more complex systems near a critical point.

Jacobs, Donald T.↗

Coexistence Curve of Perfluoromethylcyclohexane-Isopropyl Alcohol

The coexistence curve of the binary fluid mixture perfluoromethylcyclohexane-isopropyl alcohol was determined by precisely measuring the refractive index both above and below its upper critical consolute point. Sixty-seven two-phase data points were obtained over a wide range of reduced temperatures, 10(exp -5) less than t less than 2.5 x 10(exp -1), to determine the location of the critical point: critical temperature=89.901 C, and critical composition = 62.2% by volume perfluoromethylcyclohexane. These data were analyzed to determine the critical exponent 8 close to the critical point, the amplitude B, and the anomaly in the diameter. The volume-fraction coexistence curve is found to be as symmetric as any composition like variable. Correction to scaling is investigated as well as the need for a crossover theory. A model is proposed that describes the asymptotic approach to zero of the effective exponent Beta, which allows an estimation of the temperature regime free of crossover effects.

Jacobs, D. T.↗

A Brief Survey of the Equilibrium and Transport Properties of Critical Fluids and the Degree to Which Microgravity is Required for Their Experimental Investigation

The modern theory of second order phase transitions is very successful in calculating the critical exponents as an asymptotic expansion in powers of epsilon = 4 - D, the deviation of D = 3, the spatial dimension of the actual physical system from that of the abstract four-dimensional reference model. This remarkable mathematical 'tour de force' leaves unanswered, however, many fundamental questions concerning the exact nature of how the fluctuations interact. I discuss here some experiments which would help to further our understanding of the equilibrium critical properties. Especially promising would be a measurement of the temperature dependence of the turbidity very close to the critical point. This has the promise of determining the small and elusive but fundamentally important anomalous dimension exponent eta. I also review various ways of measuring the critical transport coefficients and point out some cases where ground based experiments may usefully supplement flight experiments.

Ferrell, Richard A.↗

Shear Thinning Near the Critical Point of Xenon

We measured shear thinning, a viscosity decrease ordinarily associated with complex liquids, near the critical point of xenon. The data span a wide range of reduced shear rate: 10(exp -3) < gamma-dot tau < 700, where gamma-dot tau is the shear rate scaled by the relaxation time tau of critical fluctuations. The measurements had a temperature resolution of 0.01 mK and were conducted in microgravity aboard the Space Shuttle Columbia to avoid the density stratification caused by Earth's gravity. The viscometer measured the drag on a delicate nickel screen as it oscillated in the xenon at amplitudes 3 mu,m < chi (sub 0) >430 mu, and frequencies 1 Hz < omega/2 pi < 5 Hz. To separate shear thinning from other nonlinearities, we computed the ratio of the viscous force on the screen at gamma-dot tau to the force at gamma-dot tau approximates 0: C(sub gamma) is identical with F(chi(sub 0), omega tau, gamma-dot tau )/F)(chi(sub 0, omega tau, 0). At low frequencies, (omega tau)(exp 2) < gamma-dot tau, C(sub gamma) depends only on gamma-dot tau, as predicted by dynamic critical scaling. At high frequencies, (omega tau)(exp 2) > gamma-dot tau, C(sub gamma) depends also on both x(sub 0) and omega. The data were compared with numerical calculations based on the Carreau-Yasuda relation for complex fluids: eta(gamma-dot)/eta(0)=[1+A(sub gamma)|gamma-dot tau|](exp - chi(sub eta)/3+chi(sub eta)), where chi(sub eta) =0.069 is the critical exponent for viscosity and mode-coupling theory predicts A(sub gamma) =0.121. For xenon we find A(sub gamma) =0.137 +/- 0.029, in agreement with the mode coupling value. Remarkably, the xenon data close to the critical temperature T(sub c) were independent of the cooling rate (both above and below T(sub c) and these data were symmetric about T(sub c) to within a temperature scale factor. The scale factors for the magnitude of the oscillator s response differed from those for the oscillator's phase; this suggests that the surface tension of the two-phase domains affected the drag on the screen below T(sub c).

Zimmerli, Gregory A.↗

On the formation and expansion of H II regions

The evolution of H II regions in spherical clouds with small, constant-density cores and power-law density distributions r exp -w outside the core is described analytically. It is found that there is a critical exponent above which the cloud becomes completely ionized. Its value in the formation phase depends on the initial conditions, but it has a well-defined value w(crit) = 3/2 during the expansion phase. For w less than w(crit), the radius of the H II region grows at a given rate, while neutral mass accumulates in the interphase between the ionization and shock fronts. For w = w(crit), the fronts move together without mass accumulation. Cases with w greater than w(crit) lead to the champagne phase: once the cloud is fully ionized, the expansion becomes supersonic. For self-gravitating disks without magnetic fields, the main features include a new 'variable-size' stage. The initial shape of the H II region has a critical point beyond which the disk becomes completely ionized.

Franco, Jose↗

Future utilization of space: Silverton Conference on material science and phase transformations in zero-gravity, summary of proceeding

The importance of zero gravity environment in the development and production of new and improved materials is considered along with the gravitational effects on phase changes or critical behavior in a variety of materials. Specific experiments discussed include: fine scale phase separation in zero gravity; glass formation in zero gravity; effects of gravitational perturbations on determination of critical exponents; and light scattering from long wave fluctuations in liquids in zero gravity. It is concluded that the space shuttle/spacelab system is applicable to various fields of interest.

Eisner, M.↗

Scaled parametric equation of state for oxygen in the critical region

Thermodynamic properties show an anomalous nonanalytic behavior in the critical region that cannot be represented by analytic equations used in engineering correlations. The formulation of scaling laws is discussed, taking into account an approach proposed by Schofield et al. (1969). A procedure for data analysis is described. The model considered has been found to give satisfactory results in tests conducted with a number of gases. The application of the described approach to density profiles is discussed. Attention is given to the model parameters, the critical exponents, and the coefficients for oxygen.

Levelt Sengers, J. M. H.↗

Two-scale-factor universality near the critical point of fluids

Thermodynamic data from interferometric density profile studies and light-scattering experiments near the critical isochore of Xe, CO2 and SF6 provide a basis for examining the hypothesized two-scale-factor universality for the correlation function of fluids near the gas-liquid critical point. For the investigation, three-scale-factor universality is assumed, with Ising-like critical exponent values obtained through the renormalization group technique. The two thermodynamic scale factors are found from the density profiles, while the scale factor for the correlation length is obtained from the light-scattering data.

Sengers, J. V.↗

Interfacial tension of fluids near critical points and two-scale-factor universality

Measurements of interfacial tension in the critical region of a wide variety of fluids are reviewed. The data are analyzed using theoretical values of the critical exponents to obtain amplitude ratios. Many of the data are consistent within a few percent of sigma(0). Comparison of these amplitude ratios with ratios from a field-theory calculation and from a simulation suggests that the theoretical values are about half the experimental ones. Systematic errors which are the source of this discrepancy are discussed. The data sources and processing procedures of this study are also discussed, pointing out that for liquid-vapor systems the capillary length often has a remarkably simple temperature dependence.

Moldover, M. R.↗

Heat Capacity Anomaly Near the Lower Critical Consolute Point of Triethylamine-Water

The heat capacity of the binary liquid mixture triethylamine-water has been measured near its lower critical consolute point using a scanning, adiabatic calorimeter. Two data runs are analyzed to provide heat capacity and enthalpy data that are fitted by equations with background terms and a critical term that includes correction to scaling. The critical exponent a was determined to be 0.107 +/- 0.006, consistent with theoretical predictions. When alpha was fixed at 0.11 to determine various amplitudes consistently, our values of A(+) and A(-) agreed with a previous heat capacity measurement, but the value of A(-) was inconsistent with values determined by density or refractive index measurements. While our value for the amplitude ratio A(+)/ A(-) = 0.56 +/- 0.02 was consistent with other recent experimental determinations in binary liquid mixtures, it was slightly larger than either theoretical predictions or recent experimental values in liquid-vapor systems. The correction to scaling amplitude ratio D(+)/D(-) = 0.5 +/- 0.1 was half of that predicted. As a result of several more precise theoretical calculations and experimental determinations, the two-scale-factor universality ratio X, which we found to be 0.019 +/- 0.003, now is consistent among experiments and theories. A new 'universal' amplitude ratio R(sup +/-)(sub Bcr) involving the amplitudes for the specific heat was tested. Our determination of R(sup +/-)(sub Bcr) = -0.5 +/- 0.1 and R(sup -)(sub Bcr) = 1.1 +/- 0.1 is smaller in magnitude than predicted and is the first such determination in a binary fluid mixture.

Flewelling, Anne C.↗

Study of Flow of Superfluid He-II Very Near Tau(sub lambda)

We report here, preliminary data from an experiment studying flow of superfluid helium through a slit orifice (of sub-micron width) very close to T(sub lambda). Critical supercurrent (I(sub c)) data is obtained from a step function drive to the diaphragm in a Helmholtz resonator cell. The superfluid density (rho(sub s)) data can be obtained from the resonant frequency of the Helmholtz oscillator, as determined by transfer function of the resonator or from the free ringing after the step function excitation. Preliminary data shows that I(sub c) is proportional to (rho(sub s))(exp 1.27) and rho(sub s)) is proportional to tau(exp 0.73), where tau is the reduced temperature. However, the magnitude of I(sub c) is much larger than expected, indicating a possible parallel flow path. Further investigations are in progress. Keywords: superfluid; hydrodynamics; critical exponent

Mukharsky, Yury↗

Second Sound Measurements Very Near the Lambda Point

The sound was generated by wire-wound heaters embedded in the end opposite the sensor in each cavity. The superfluid density was determined from second sound measurements and the critical exponent v was obtained from fits to the data. The results from the exponent were found to be very sensitive to the treatment of systematic effects in the data.

sound measurements Lambda point superfluid↗