Search NASA⌕ Search

SEARCH · Search NASA

Results for “Criticality Accident Alarm System (CAAS) Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Experiment Design and Preparation for a Shielding Benchmark Utilizing Godiva-IV

An experiment is currently being designed to provide a high-quality shielding benchmark for Criticality Accident Alarm System (CAAS) modeling. Previous benchmarks have suffered from uncertainty primarily due to two factors. The first factor is radiation that is not directly coming from the source, also known as room return. Room return is notoriously difficult to account for in experimental data and to model in benchmarks. The second factor is uncertainty associated with the source term itself. In order to reduce these two sources of uncertainty, this experiment will utilize a room return shield [1] that will reduce the effect of room return and previous work performed to ensure the reproducibility of the source term. The experiment will use the Godiva IV [2] assembly located at the National Criticality Experiments Research Center (NCERC) to provide a neutron source representative of a criticality accident. Previous experiments [3]-[4] have shown that Godiva IV is capable of producing both bursts and steady-state emissions of equal magnitude which will allow for reduced uncertainty in the source term. The room return shield will house and isolate the shielding samples, neutron activation foils, and other detectors. Data collected will provide a comparison of the neutron and gamma dose for shielded and unshielded configurations. This data will be used to validate shielding data used for modeling criticality accident alarm systems. Shielding samples included in this benchmark are C, Fe, NaCl, Pb, high density polyethylene, and SiO 2 . This paper details the design of the room return shield, the experimental plan, challenges, and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using the Criticality Accident Alarm System modeling capabilities in SCALE [Slides]

The following is a summary of advice for CAAS modeling in SCALE. Refer to the SCALE Criticality Safety and Radiation Shielding training slides or to the SCALE manual for exact syntax. Use a mesh for the fission source that is the most adequate for the problem to solve (coarse/fine). Don’t spend unnecessary resources; simplify the model if it does not impact the final results of interest. Be careful to deactivate secondary fissions in MAVRIC or the calculation may never end. Check that k eff and $\overline{\upsilon}$ calculated results are logical. Between KENO and MAVRIC, cross section libraries, materials, geometry, and mesh grid can be the same or different. Iterative calculations are usually complex problems that need variance reduction. It will be hard to find the best solving parameters in the first attempt; expert judgement is needed. Check each step separately. Use Fulcrum to visualize fission source, mesh source, and spatial/energy distributions to find potential errors or impactful imprecisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Criticality Accident Alarm System Modeling for the Uranium Processing Facility

The Criticality Accident Alarm System (CAAS) for the Uranium Processing Facility (UPF) provides coverage for two primary processing facilities. For UPF, detailed documentation and drawings of the design are readily available. While this design information allows for some CAAS modeling features to match the actual design with a high level of accuracy, assumptions and simplifications are necessary as it is unrealistic and unnecessary to replicate many aspects of the design. A set of modeling guidelines and techniques were used to develop consistency between the MCNP6 models. While ensuring conservatism, overly conservative choices must be avoided to demonstrate the minimum accident of concern can be detected. To ensure proper modeling choices were made for the final models, a group of parametric studies were performed to evaluate the impact on the dose rates detected at the individual detectors. Some of these modeling choices and/or associated parametric studies include: - Modeling the grid steel area above the detectors as homogeneous stainless steel and determining the impact on detectability with an increasing density. - Modeling the presence of equipment in close proximity to the CAAS detectors. - Determining an appropriate material density to represent miscellaneous items not specifically modeled. - Evaluating the impact of sprinkler activation. The results of UPF CAAS analyses show that the modeling assumptions made based on the detailed design and parametric studies are appropriate and demonstrate accurate yet conservative models have been developed for detecting minimum accident of concern within the UPF.

61 RADIATION PROTECTION AND DOSIMETRY↗

NDCS Group Meeting Work overview: NCSP Task ORNL IP&D-5 [Slides]

The presentation discusses the primary goal of the NCSP Task IP&D-5 which is to use available data from HPRR operation to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The presentation elaborates on the HPRR operation and how it relates to the KENO VI model, sulfur pellets measurements, and calculation methodology between KENO and MAVRIC FW-CADIS. The presentation concludes by stating that some work is still needed to evaluate uncertainties and to explain the discrepancy computation/experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview [Slides]

This presentation discusses the Health Physics Research Reactor (HPRR) or Fast Burst Reactor (FBR) and how available data from Health Physics Research Reactor (HPRR) operation to can be used to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The evaluation of experimental data is also presented, specifically four experimental candidates are considered of potential value for the benchmark: 1. Neutron source estimation from a HPRR pulse (energy spectrum, fission yield), 2. Threshold Detector Unit (TDU) measurements at different distances from a HPRR pulse, shielded and unshielded, 3. Sulfur pellet activation at different distances from a HPRR pulse, shielded and unshielded, and 4. Total neutron fluence from a HPRR pulse measured by Bonner Sphere Spectrometry, shielded and unshielded. Additionally, a benchmark model overview is discussed as are sample calculation results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation [Slides]

During the evaluation of Oak Ridge National Laboratory Health Physics Research Reactor operation data for critical benchmark creation, a detailed, functional SCALE model was built, and experimental data was evaluated for the creation of a critical benchmark. The estimated experimental uncertainty is about 3800 pcm, which is considered very high. The relative difference between expected and calculated keff values is about 1.5 %, also considered very high. It was concluded that a good quality critical benchmark worthy of the ICSBEP standards cannot be created from HPRR data in the present conditions. Locating the HPRR fuel to obtain an uncertainty on the density would aid in solving this issue.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview

From the countless critical experiments performed in the world during the past century, high-quality integral benchmarks experiments have been collected and gathered into the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook), managed by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group. This information preservation and dissemination effort is crucial for reactor licensing as well as criticality and radiation transport modeling validation. This summary reports on the status of a tentative benchmark addition to the ICSBEP Handbook. The proposed benchmark arises from legacy operation data of the Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR). The HPRR was a small, unmoderated, unshielded fast burst reactor that was used for research in health physics and radiobiology as well as teaching and training. As part of a comprehensive investigation of the available HPRR operation data and characteristics, different possibilities for use of the valuable results were studied. A critical experiment benchmark evaluation was performed, analyzing data coming from sub-critical and critical operation of the HPRR during operator training, steady-state irradiation of samples and before critical bursts. The results of the evaluation do not satisfy for the ICSBEP standards as the benchmark relative standard uncertainty is of about 4% for k eff , and the relative difference between sample calculations and expected k eff results is of about 1.5%. Due to those unsatisfactory results, it was decided not to pursue critical experiments evaluation of the HPRR presently and to focus instead on shielding type data for the creation of a criticality accident alarm system (CAAS) and shielding category benchmark, which is currently very scarce in the ICSBEP handbook—especially concerning critical, pulsed assembly, or reactor operation data. Several dosimetry and shielding experiments from HPRR burst operation were evaluated, with different benchmark metrics as sulfur fluence, Element 57 dose, or neutron fluence at different distances and under different shield materials conditions. An evaluation focusing on the Element 57 neutron dose as a benchmark metric was submitted to the ICSBEP Technical Review Group (TRG) meeting in October 2021, and the inclusion of the evaluation in the ICSBEP Handbook was deferred. The main change proposed by the international experiment evaluation experts is to use the neutron fluence measured by Bonner spheres as a benchmark metric. This represents a quantity closer to that actually measured by the experimentalists of the HPRR compared to the Element 57 dose, which adds another step of data transformation, thus potentially adding uncertainty to the benchmark. The evaluation has been updated and will be submitted to the 2022 ICSBEP TRG meeting for inclusion in the 2023 edition of the ICSBEP Handbook. The evaluation is performed using the KENO and MAVRIC combination from the SCALE 6.2.4 code suite which was previously used in similar CAAS benchmarks to allow for the use of variance reduction techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗