Availability of Critical Benchmark Experiments for the Pebble Tanker Transportation Model for Nuclear Criticality Safety Validation of TRISO Pebbles

This study addresses the need for comprehensive investigations into TRi-structural ISOtropic (TRISO) fuel pebble transportation validation. In this work, an exploratory model, the pebble tanker(PT), was developed with the aim of facilitating the validation of nuclear criticality safety calculations in the context of industrial-scale transportation of TRISO fuel. The PT model was designed to investigate the availability and applicability of critical benchmark experiments crucial for assessing the transportation of these pebbles. This work incorporated sensitivity/uncertainty (S/U) similarity studies to quantify the applicability of critical benchmark experiments and to address nuclear data uncertainties in the context of TRISO transportation. Two container models were investigated: one for the Hermes-type pebble and one for the Pebble Bed Modular Reactor (PBMR)–type pebble. The models were simplified, considering fuel, containment, and either water or air, to enable a focus on the underlying physics of applications involving TRISO fuel pebbles using the PT model. A crucial aspect under consideration was the capacity of the transport package to hold pebbles while ensuring subcriticality in the flooded state. An approach in the criticality validation process involves assessing the similarity between systems through an integral index parameter evaluation. This involves calculating a correlation coefficient (referred to as c k ) based on shared nuclear data–induced uncertainty between a benchmark experiment and the application of the PT model. To facilitate this analysis, the SCALE tools, particularly the CSAS6-Shift, TSUNAMI-3D-Shift, and TSUNAMI-IP sequences, were employed for comprehensive studies in neutronics and S/U analysis. Our findings showed that there are sufficient critical experimental benchmarks to perform this validation of the PT model in the most reactive state, i.e. when the tanker is flooded. This paper provides valuable insights into validating a transport package for Generation IV TRISO fuel pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The MUSIC Critical Benchmark and Nuclear Data

The Measurement of Uranium Subcritical and Critical (MUSIC) experiment was a series of measurements of critical and subcritical configurations of bare highly enriched uranium. The goal was to compare measurement methods, analysis techniques, and simulation methods across regimes of criticality and to provide high-quality validation of 235 U nuclear data. A benchmark evaluation of the two critical configurations of the MUSIC experiments will soon be published in the release of the International Criticality Safety Benchmark Evaluation Project Handbook. The recent execution of the experiment aids in proper quantification of model simplifications and all uncertainties associated with the experiment. Historical benchmark evaluations are heavily relied on for uranium nuclear data validation despite the fact that the same level of documentation and comparable uncertainty analysis may not be present. The MUSIC evaluation is less likely to include “unknown unknowns” that could impede accurately modeling the system. Presented are both highly detailed and very simplified models, which represent the experimental configurations accurately, aiding the users of the benchmark for nuclear data or transport code validation. The sensitivities of k eff to nuclear data and nuclear data–related uncertainties are very similar between this experiment and previous bare uranium sphere experiments. In addition, the nuclear data uncertainties to any nuclides other than 235 U are small. For all these reasons, the recently evaluated MUSIC benchmark critical configurations could prove very useful for 235 U nuclear data validation. Currently, major libraries have good agreement with the experimental results, within 200 pcm for all nuclear data libraries, and within one standard deviation of the experimental result for most. Suggested nuclear data adjustments based on MUSIC and Lady Godiva are also presented, with posterior improvements to both the agreement in k eff and the uncertainty associated with the nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Continuous-Energy Verification of MCNP Calculations Using One-Group Spherical and Slab Criticality Benchmarks

This work presents a continuous-energy Monte Carlo verification study of one group spherical and slab criticality benchmarks using the MCNP ®1 code. Classical tabulations and newly generated benchmark solutions obtained by direct numerical evaluation by the author are considered. The benchmarks span weakly to strongly multiplying regimes and provide analytically defined critical radii as functions of a single parameter, c .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Role of Nuclear Data Sensitivities in Prompt α-Eigenvalue Predictions of Delayed Critical Benchmarks

Alpha (α) eigenvalues, which describe the logarithmic time derivative of the neutron population in a multiplying system, are integral to time-dependent behavior and diagnostic applications. However, uncertainties in the evaluated nuclear data can significantly impact the accuracy of transport simulations for such quantities. This work explores the use of machine learning models to predict two key outputs, α-eigenvalues and keff bias, using input features derived from α-eigenvalue sensitivities to nuclear data. The criticality safety benchmark models used in this study come from the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Three models, random forest, XGBoost, and NGBoost, are trained on both energy-resolved and energy-summed α sensitivities. For the α-eigenvalue bias prediction, NGBoost achieved the highest R 2 (0.9476) using energy-resolved features, while XGBoost performed best using summed sensitivities. In contrast, when predicting the keff bias, all the models showed moderate predictive capability (best R 2 ≈ 0.72), as the mapping from the static α-sensitivities to the static keff bias was less direct. SHAP (SHapley Additive exPlanations) analysis was used to interpret the model predictions. Across both prediction tasks, the features associated with neutron capture [H-1 (n, γ)], uranium scattering reactions (such as 235 U elastic/inelastic), and actinide capture/fission reactions (such as 239 Pu and 234 U) were consistently identified as the most impactful. This highlights the key role of specific nuclear reactions and energy ranges in shaping both time-dependent and steady-state criticality behavior. These results demonstrated that α-sensitivities, despite being computed for time-dependent metrics, can provide valuable insights for predicting both α-eigenvalues and the keff bias. Moreover, machine learning models offer a promising pathway for uncovering important nuclear data dependencies and guiding future data evaluation efforts.

Nuclear data↗

Status of the International Criticality Safety Benchmark Evaluation Project

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) has continued its work generating evaluations of new and historical criticality benchmark experiments since the last update to the nuclear criticality safety community at the 11th International Conference on Nuclear Criticality Safety (ICNC 2019) in Paris, France. Three additional versions of the ICSBEP Handbook have been published since that update, and the Technical Review Group (TRG) held two in-person (in 2019 and 2023) and three virtual (2020 and 2021) meetings to review and approve additional benchmarks. The 2019 edition of the ICSBEP Handbook included five new evaluations with 79 new configurations, the 2020 version of the ICSBEP Handbook contained five new evaluations totaling 76 new configurations, and the 2021 version of the ICSBEP handbook contained five new evaluations with a total of 57 different configurations. The ICSBEP TRG met in October and December 2021, to review benchmarks for potential inclusion in the 2022 ICSBEP Handbook, with seven evaluations receiving provisional approval pending resolution of review group comments. Final comment resolution for some of these evaluations is currently underway and handbook publication should be completed soon. The ICSBEP TRG met again in person in April 2023 to review benchmarks for the 2023 ICSBEP Handbook, provisionally approving 7 new evaluations. The ICSBEP continues to deliver high-quality, peer reviewed evaluations of experiments relevant to the nuclear criticality safety community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of New MCNP6.3 Features for Critical and Subcritical Benchmark Simulations [Slides]

A separate MCNP6.3 V&V document reports on all the default calculations for all test suites was introduced. Here, we look at new optional features of the MCNP6.3 code. Then, Fission-matrix-based options with Convergence and population testing and Automated acceleration of the fission source and Doppler Broadening Resonance Correction and HDF5 Particle Track Output (PTRAC) and Validation benchmarks: criticality, Rossi-α, and subcritical multiplication. All the new MCNP6.3 options give statistically equivalent results and should be considered for default usage in criticality and subcritical multiplication calculation work. Discussed are two separate papers at the upcoming 2023 International Conference on Nuclear Criticality Safety (ICNC 2023) that give more details on the results presented here.

97 MATHEMATICS AND COMPUTING↗

Status of the International Criticality Safety Benchmark Evaluation Project

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) has continued its work generating evaluations of new and historical benchmark experiments since the last update to the nuclear criticality safety (NCS) community at the 12th International Conference on Nuclear Criticality Conference held in 2023. One additional version of the ICSBEP Handbook has been published since that update, and the Technical Review Group (TRG) held two in-person meetings to review and approve additional benchmarks. The 2022 and 2023 editions of the handbook were combined into one release (published in November 2024) and contained 13 new evaluations with 46 different configurations and two major revisions to existing evaluations. The 2024 version of the handbook, currently under publication review, will contain two new evaluations with 15 new configurations and one major revision to HEU-MET-FAST-028, the evaluation of Flattop with a uranium core. The ICSBEP TRG met again in person in April 2025 to review benchmarks for the 2025 ICSBEP Handbook and final comment resolution is currently ongoing. Many of the new benchmarks represent contemporaneous experiments that have been specifically optimized to provide validation cases relevant to the NCS community. One major area of focus for new critical experiments is to target the sparsely populated intermediate energy (or resonance) region. Another focus of many of the new benchmarks is to provide experiments sensitive to different materials, such as chlorine, hafnium, tantalum, titanium, molybdenum, chromium, and polymethyl methacrylate (PMMA, or Lucite). The ICSBEP continues to deliver high-quality, peer reviewed evaluations of integral experiments relevant to the nuclear data community.

HEU-MET-FAST-028↗

Resolved resonance region evaluations of n+ 206,207,208 Pb for fast spectrum applications

Resolved resonance region evaluations of the major isotopes of natural lead, 206 Pb, 207 Pb, 208 Pb, have been per formed to support the development of Generation IV reactors. In this study, validation of nuclear data for lead fast reactors was performed with simulations of shielding benchmarks, integral critical benchmarks, and quasi-differential scattering measurements. Sensitivity analyses of these systems showed that elastic scattering reactions above 100 keV were the dominant reactions driving system performance. The resolved resonance regions (RRRs) of the lead isotopes extend past 100 keV, making the RRR an ideal starting point to evaluate lead cross sections. Since the R-matrix requires knowledge of bound, distant, and observed resonances, it was necessary to evaluate from 10 -5 eV up to the respective limit of the RRR. The 208 Pb RRR evaluation was extended to 1.5 MeV in order to obtain resonance parameters used to calculate new elastic scattering angular distributions up to 1.5 MeV. Resonance parameter uncertainties and covariance were generated using the R-matrix code SAMMY. The new RRR parameters show a direct improvement to the scattering kernel below 1.5 MeV which in turn greatly improves fast critical experiments over ENDF/B-VIII.0.

206Pb↗

Criticality Experiments to Reduce Compensating Errors in Plutonium Nuclear Data

Compensating errors between nuclear data observables in a library can adversely impact application simulations. The primary goal of the EUCLID project (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) is to reduce compensating errors in nuclear data. A new criticality experiment, described in this work, was designed with the specific target nuclear data of 239 Pu fission, inelastic scattering, elastic scattering, capture, nu-bar, and prompt fission neutron spectrum (PFNS). This work will focus on the design and execution of the EUCLID experiment, performed on the Planet vertical lift critical assembly machine at the National Criticality Experiments Research Center (NCERC). The criticality experiment includes two different configurations with very different geometries: one is cube-like to minimize neutron leakage while the other is slab-like to maximize leakage. Having these two widely varying configurations allows the scattering sensitivities of 239 Pu to the neutron multiplication factor to be greatly changed while minimally impacting the other cross section sensitivities. Both configurations utilize the Pu ZPPR (Zero Power Physics Reactor) plates as fuel. The experiments were designed using a D-Optimality criteria, which is an optimization method minimizing the log-determinant of the adjusted nuclear data covariance for the target reactions. These experiments include not only inference of k eff , as done in all critical benchmark experiments, but several other responses as well, such as neutron multiplication measurements and reaction rate ratios. After analysis of the measured data is complete, adjustment of nuclear data will be performed to assess whether the new experimental data successfully reduced compensating errors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of the CERBERUS Evaluation for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook

Modeling & Simulation (M&S) tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers continue to improve, we are able to enhance resolution in our calculations. Therefore, the limitations of simulation capability are in the quality of data that is being used, including our ability to quantify the uncertainty and sensitivity of that data. In order to model systems of interest with increasing accuracy, the industry must improve key nuclear data measurements. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles and evaluates experiment data in a handbook that can be used by criticality safety engineers and others to validate computer codes and cross section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. These experiments, along with differential measurements, can help improve the quality of nuclear data. Concerns regarding the accuracy of Cu nuclear data have been published. The large values and trend of C-E for the Zeus intermediate energy benchmark, being one of the primary examples. Furthermore, very few experiments have been designed to be sensitive to Cu (as shown in Figure 1), so an integral, critical experiment is needed to help resolve these differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluated Nuclear Data Requirements in Support of Fission and Fusion Applications [Slides]

This presentation touches on thermal scattering cross section and scattering lengths including criticality benchmarks (fission). Secondly, development and completeness of charged ­particle libraries: criticality benchmarks (fission), neutron source (fission/fusion), simulation benchmarks and light elements generation (fusion). Additionally, this presentation details on the covariances (methodology and completeness) with adjustment and optimization of nuclear data libraries (fission/fusion). Finally nuclear data reproducibility and conclusions are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verified, Archived, Library of Inputs and Data (VALID) Supporting Files

This dataset contains input, output, and sensitivity data files for computational simulations with the SCALE code system as part of the Verified, Archived Library of Inputs and Data (VALID). The simulations cover critical benchmark experiments from the International Criticality Safety Benchmark Evaluation Project. The files are to be housed in a public directory for distribution. The information contained in the files have been approved for release by the Organisation for Economic Co-operation and Development Nuclear Energy Agency (NEA). Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases.

keff↗

Constraining the impact of chlorine as a neutron absorber in next-gen fast reactor designs

The role of chlorine as a neutron poison and as a seed for producing radioactive waste in nuclear systems has driven a renewed interest to improve its nuclear data uncertainties. Additionally, basic and applied science programs that use CLYC (Cs 2 LiYCl 6 :Ce) detectors for neutron spectroscopy and monitoring are also very sensitive to any change in chlorine nuclear data for simulations of the detector response. In this work, sensitivities relevant for these different applications are addressed through simulations of the efficiency of CLYC detectors in a fast fission spectrum when applying new chlorine nuclear data as input. These simulations are validated by an experimental measurement using CLYC detectors coupled to an ionization chamber loaded with a 252 Cf spontaneous fission source. The results are then used to obtain the first reliable direct measurement of the 35 Cl(n,p 0 ) and summed Cl(n,p+n,α) fission spectrum average cross sections, found to be 54.7(32) and 105.0(98) mb, respectively. The results are within uncertainty of calculated fission spectrum averaged cross sections based on recently re-evaluated chlorine nuclear data, which confirm recent impact studies performed for the Molten Chloride Reactor Experiment. Meanwhile, there currently exists only one published criticality benchmark experiment that is sufficiently sensitive to chlorine nuclear data. Discrepancies are found with this set of criticality safety benchmarks, which are more sensitive to thermal and epithermal neutron energies than the energies, above 100 keV, tested in this current work. Hence, there is still a need to re-evaluate the chlorine nuclear data at lower energies to assess these discrepancies. Interpretation of the data from future “faster” criticality benchmarks, which are needed for next-gen fast reactor designs, benefit from the improved constraints on the chlorine nuclear data validated in this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cerberus and the Zeus Suite of Critical Experiment Benchmarks [Slides]

This presentation finds that as it was designed, Cerberus is extremely sensitive to copper nuclear data. Just changing copper nuclear data to another library can swing simulated keff by >1000 pcm. ENDF/B-VIII.1 and JENDL-5.0 both show large downward trends in keff as copper interstitial thickness is increased

ENDF/B-VIII.1↗