Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cross-Over Studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Large-scale separation and hysteresis in cascades

An approach using a two-dimensional thin aerofoil, allied with the theory of viscous bluff-body separation, is used to study the initial cross-over from massive separation to an attached flow in a single-row unstaggered cascade. Analytic solutions are developed for the limit of small cascade-spacing. From the analytic solutions several interesting features of the cascade are examined, including multiple-solution branches and multiple regions of hysteresis. In addition, numerical results are presented for several selected aerofoils. Some of the aerofoils are found to contain markedly enlarged regions of hysteresis for certain critical cascade spacings.

Rothmayer, A. P.↗

Dose-response relationship between sleep duration and human psychomotor vigilance and subjective alertness

Although it has been well documented that sleep is required for human performance and alertness to recover from low levels after prolonged periods of wakefulness, it remains unclear whether they increase in a linear or asymptotic manner during sleep. It has been postulated that there is a relation between the rate of improvement in neurobehavioral functioning and rate of decline of slow-wave sleep and/or slow-wave activity (SWS/SWA) during sleep, but this has not been verified. Thus, a cross-study comparison was conducted in which dose-response curves (DRCs) were constructed for Stanford Sleepiness Scale (SSS) and Psychomotor Vigilance Task (PVT) tests taken at 1000 hours by subjects who had been allowed to sleep 0 hours, 2 hours, 5 hours or 8 hours the previous night. We found that the DRCs to each PVT metric improved in a saturating exponential manner, with recovery rates that were similar [time constant (T) approximately 2.14 hours] for all the metrics. This recovery rate was slightly faster than, though not statistically significantly different from, the reported rate of SWS/SWA decline (T approximately 2.7 hours). The DRC to the SSS improved much more slowly than psychomotor vigilance, so that it could be fit equally well by a linear function (slope = -0.26) or a saturating exponential function (T = 9.09 hours). We conclude that although SWS/SWA, subjective alertness, and a wide variety of psychomotor vigilance metrics may all change asymptotically during sleep, it remains to be determined whether the underlying physiologic processes governing their expression are different.

Non-NASA Center↗

Pre-exercise glycerol hydration improves cycling endurance time

The effects of glycerol ingestion (GEH) on hydration and subsequent cycle ergometer submaximal load exercise were examined in well conditioned subjects. We hypothesized that GEH would reduce physiologic strain and increase endurance. The purpose of Study I (n = 11) was to determine if pre-exercise GEH (1.2 gm/kg glycerol in 26 ml/kg solution) compared to pre-exercise placebo hydration (PH) (26 ml/kg of aspartame flavored water) lowered heart rate (HR), lowered rectal temperature (Tc), and prolonged endurance time (ET) during submaximal load cycle ergometry. The purpose of Study II (n = 7) was to determine if the same pre-exercise regimen followed by carbohydrate oral replacement solution (ORS) during exercise also lowered HR, Tc, and prolonged ET. Both studies were double-blind, randomized, crossover trials, performed at an ambient temperature of 23.5-24.5 degrees C, and humidity of 25-27%. Mean HR was lower by 2.8 +/- 0.4 beats/min (p = 0.05) after GEH in Study I and by 4.4 +/- 1.1 beats/min (p = 0.01) in Study II. Endurance time was prolonged after GEH in Study I (93.8 +/- 14 min vs. 77.4 +/- 9 min, p = 0.049) and in Study II (123.4 +/- 17 min vs. 99.0 +/- 11 min, p = 0.03). Rectal temperature did not differ between hydration regimens in both Study I and Study II. Thus, pre-exercise glycerol-enhanced hyperhydration lowers HR and prolongs ET even when combined with ORS during exercise. The regimens tested in this study could potentially be adapted for endurance activities.

Non-NASA Center↗

Acute effect of ephedrine on 24-h energy balance

Ephedrine is used to help achieve weight control. Data on its true efficacy and mechanisms in altering energy balance in human subjects are limited. We aimed to determine the acute effect of ephedrine on 24-h energy expenditure, mechanical work and urinary catecholamines in a double-blind, randomized, placebo-controlled, two-period crossover study. Ten healthy volunteers were given ephedrine (50 mg) or placebo thrice daily during each of two 24-h periods (ephedrine and placebo) in a whole-room indirect calorimeter, which accurately measures minute-by-minute energy expenditure and mechanical work. Measurements were taken of 24-h energy expenditure, mechanical work, urinary catecholamines and binding of (+/-)ephedrine in vitro to human beta1-, beta2- and beta3-adrenoreceptors. Twenty-four-hour energy expenditure was 3.6% greater (8965+/-1301 versus 8648+/-1347 kJ, P<0.05) with ephedrine than with placebo, but mechanical work was not different between the ephedrine and placebo periods. Noradrenaline excretion was lower with ephedrine (0.032+/-0.011 microg/mg creatinine) compared with placebo (0.044+/-0.012 microg/mg creatinine) (P<0.05). (+/-)Ephedrine is a relatively weak partial agonist of human beta1- and beta2-adrenoreceptors, and had no detectable activity at human beta3-adrenoreceptors. Ephedrine (50 mg thrice daily) modestly increases energy expenditure in normal human subjects. A lack of binding of ephedrine to beta3-adrenoreceptors and the observed decrease in urinary noradrenaline during ephedrine treatment suggest that the thermogenic effect of ephedrine results from direct beta1-/beta2-adrenoreceptor agonism. An indirect beta3-adrenergic effect through the release of noradrenaline seems unlikely as urinary noradrenaline decreased significantly with ephedrine.

Non-NASA Center↗

Restoration of peak vascular conductance after simulated microgravity by maximal exercise

We sought to determine if (i) peak vascular conductance of the calf was reduced following prolonged exposure to simulated microgravity, and (ii) if maximal cycle ergometry performed at the end of microgravity exposure stimulated a restoration of peak calf vascular conductance. To do this, peak vascular conductance of the calf was recorded following ischaemic plantar flexion exercise to fatigue in seven men after 16 days of head-down tilt (HDT) under two conditions: (i) after one bout of maximal supine cycle ergometry completed 24 h prior to performance of ischaemic plantar flexion exercise, and (ii) in a control (no cycle ergometry) condition. Following HDT, peak vascular conductance was reduced in the control condition (0.38 +/- 0.02 to 0.24 +/- 0.02 ml 100 ml-1 min-1 mmHg-1; P = 0.04), but was restored when subjects performed cycle ergometry (0.33 +/- 0.05 to 0.28 +/- 0.04 ml 100 ml-1 min-1 mmHg-1; P = 0.46). After HDT, time to fatigue during ischaemic plantar flexion exercise was not different from pre-HDT 24 h after performance of exhaustive cycle ergometry (120 +/- 24 vs. 122 +/- 19 s), but was decreased in the control condition (116 +/- 11 vs. 95 +/- 8 s; P = 0.07). These data suggest that a single bout of maximal exercise can provide a stimulus to restore peak vascular conductance and maintain time to fatigue during performance of ischaemic plantar flexion exercise.

NASA Discipline Cardiopulmonary↗

Evidence for increased cardiac compliance during exposure to simulated microgravity

We measured hemodynamic responses during 4 days of head-down tilt (HDT) and during graded lower body negative pressure (LBNP) in invasively instrumented rhesus monkeys to test the hypotheses that exposure to simulated microgravity increases cardiac compliance and that decreased stroke volume, cardiac output, and orthostatic tolerance are associated with reduced left ventricular peak dP/dt. Six monkeys underwent two 4-day (96 h) experimental conditions separated by 9 days of ambulatory activities in a crossover counterbalance design: 1) continuous exposure to 10 degrees HDT and 2) approximately 12-14 h per day of 80 degrees head-up tilt and 10-12 h supine (control condition). Each animal underwent measurements of central venous pressure (CVP), left ventricular and aortic pressures, stroke volume, esophageal pressure (EsP), plasma volume, alpha1- and beta1-adrenergic responsiveness, and tolerance to LBNP. HDT induced a hypovolemic and hypoadrenergic state with reduced LBNP tolerance compared with the control condition. Decreased LBNP tolerance with HDT was associated with reduced stroke volume, cardiac output, and peak dP/dt. Compared with the control condition, a 34% reduction in CVP (P = 0.010) and no change in left ventricular end-diastolic area during HDT was associated with increased ventricular compliance (P = 0.0053). Increased cardiac compliance could not be explained by reduced intrathoracic pressure since EsP was unaltered by HDT. Our data provide the first direct evidence that increased cardiac compliance was associated with headward fluid shifts similar to those induced by exposure to spaceflight and that reduced orthostatic tolerance was associated with lower cardiac contractility.

Non-NASA Center↗

Applications of a high power four-way power divider and combiner and a cross-over circuit

Circuits of rectangular waveguides coupled to a cylindrical cavity have been studied. Two types of circuits were developed: a high-power four-way power divider/combiner with less than 0.5 dB insertion loss over a 20 percent bandwidth and a high-power four-port cross-over circuit with less than 0.7 dB insertion loss and 20 dB isolation at X-band. To demonstrate the feasibility of the first circuit, a power combiner was built by connecting four Gunn oscillators to the four rectangular waveguide ports of the radial waveguide. A power combining efficiency of over 70 percent was achieved at X-band. The second circuit was used to feed a dual-polarization cross-slot antenna backed by a cylindrical cavity.

Chang, Kai↗

Body fluid alterations during head-down bed rest in men at moderate altitude

To determine the effects of hypoxia on fluid balance responses to simulated zero-gravity, measurements were made in six subjects before and during -5 deg continuous head-down bed rest (HDBR) over 8 d at 10,678 ft. The same subjects were studied again at this altitude without HDBR as a control (CON) using a cross-over design. During this time, they maintained normal upright day-time activities, sleeping in the horizontal position at night. Fluid balance changes during HDBR in hypoxia were more pronounced than similar measurements previously reported from HDBR studies at sea level. Plasma volume loss was slightly greater and the diuresis and natriuresis were doubled in magnitude as compared to previous studies in normoxia and sustained for 4 d during hypoxia. These changes were associated with an immediate but transient rise in plasma atrial natriuretic peptide (ANP) to day 4 of 140 percent in HDBR and 41 percent in CON (p less than 0.005), followed by a decline towards baseline. Differences were less striking between HDBR and CON for plasma antidiuretic hormone and aldosterone, which were transiently reduced by HDBR. Plasma catecholamines showed a similar pattern to ANP in both HDBR and CON, suggesting that elevated ANP and catecholamines together accounted for the enhanced fluid shifts with HDBR during hypoxia.

Loeppky, J. A.↗

A Comparison of Structurally Connected and Multiple Spacecraft Interferometers

Structurally connected and multiple spacecraft interferometers are compared in an attempt to establish the maximum baseline (referred to as the "cross-over baseline") for which it is preferable to operate a single-structure interferometer in space rather than an interferometer composed of numerous, smaller spacecraft. This comparison is made using the total launched mass of each configuration as the comparison metric. A framework of study within which structurally connected and multiple spacecraft interferometers can be compared is presented in block diagram form. This methodology is then applied to twenty-two different combinations of trade space parameters to investigate the effects of different orbits, orientations, truss materials, propellants, attitude control actuators, onboard disturbance sources, and performance requirements on the cross-over baseline. Rotating interferometers and the potential advantages of adding active structural control to the connected truss of the structurally connected interferometer are also examined. The minimum mass design of the structurally connected interferometer that meets all performance-requirements and satisfies all imposed constraints is determined as a function of baseline. This minimum mass design is then compared to the design of the multiple spacecraft interferometer. It is discovered that the design of the minimum mass structurally connected interferometer that meets all performance requirements and constraints in solar orbit is limited by the minimum allowable aspect ratio, areal density, and gage of the struts. In the formulation of the problem used in this study, there is no advantage to adding active structural control to the truss for interferometers in solar orbit. The cross-over baseline for missions of practical duration (ranging from one week to thirty years) in solar orbit is approximately 400 m for non-rotating interferometers and 650 m for rotating interferometers.

Surka, Derek M.↗

Multi-angle Imaging SpectroRadiometer (MISR): Optical Characterization of the Spectralon Calibration Panels

The reflectance properties of an engineering model of the Spectralon panel intended for use within an On-Board Calibrator (OBC) on the NASA Multi-angle Imaging SpectroRadiometer (MISR) instrument have been fully characterized with regard to panel uniformity and isotropy in response to three incident laser wavelengths of 442, 632.8 and 859.9 nm. A regional variation in bidirectional reflectance function (BRF) across the surface of the engineering model (EM) panel, contributing to spatial non-uniformity at the +/-2% level has been measured at all three laser wavelengths. Further, a BRF anisotropy has been identified. The mechanism causing these departures from the ideal Lambertian surface may originate in the sanding of the Spectralon surface in the final stage of preparation. This is corroborated by measurements made on a 'pressed' polytetrafluoroethylene (PTFE) panel in which a greatly reduced anisotropy in panel BRF is measured. The EM panel BRF reveals deviation from a Lambertian characteristic manifest as an off-specular peak in the forward scattering direction. A common cross-over point at an angle of reflection of around 37 at which the BRF is constant within 0.4% for an illumination angle range of ui = 30 60 is observed at all three wavelengths. Two Spectralon protoflight panels which were fabricated after the engineering model was studied were also the subject of a uniformity study over part of the area of the Spectralon panels at the 442 nm wavelength. The analysis indicated that the panel uniformity satisfies the 0.5% criterion indicating improved panel preparation. However, the off specular peak in the forward scattering direction is essentially unchanged with the cross-over point at approximately 37.

Multi-angle Imaging SpectroRadiometer↗

Acquisition Performances Of QPSK Carrier-Tracking Loops

Report presents comparative study of acquisition performances of several types of carrier-signal-tracking loops for reception of quadrature phase-shift keying (QPSK) signals. Loops classified into three types: maximum a-posteriori, (MAP) estimation loop, Costas cross-over loop, and generalized Costas loop. Mathematical models developed. In-phase and quadrature signals generated numerically and processed according to loop algorithms. Results show though MAP loop produces smallest squaring loss at all signal-to-noise ratios, others sometimes exhibit shorter acquisition time and greater probability of acquisition.

Hinedi, Sami M.↗

A New Clinical Instrument for The Early Detection of Cataract Using Dynamic Light Scattering and Corneal Topography

A growing cataract can be detected at the molecular level using the technique of dynamic light scattering (DLS). However, the success of this method in clinical use depends upon the precise control of the scattering volume inside a patient's eye and especially during patient's repeat visits. This is important because the scattering volume (cross-over region between the scattered fight and incident light) inside the eye in a high-quality DLS set-up is very small (few microns in dimension). This precise control holds the key for success in the longitudinal studies of cataract and during anti-cataract drug screening. We have circumvented these problems by fabricating a new DLS fiber optic probe with a working distance of 40 mm and by mounting it inside a cone of a corneal analyzer. This analyzer is frequently used in mapping the corneal topography during PRK (photorefractive keratectomy) and LASIK (laser in situ keratomileusis) procedures in shaping of the cornea to correct myopia. This new instrument and some preliminary clinical tests on one of us (RRA) showing the data reproducibility are described.

Ansari, Rafat R.↗

Control of nausea and autonomic dysfunction with terfenadine, a peripherally acting antihistamine

Terfenadine (Seldane) was admisistered to 14 male subjects in a randomized, double-blinded, and cross-over design to assess the efficacy of this peripherally active antihistamine as an antimotion sickness drug. Terfenadine possesses practically no central side effects. A staircase profile test was administered 4 h following placebo or a single oral dose of terfenadine (300 mg). The study revealed a statistically significant therapeutic effect from terfenadine (p less than 0.05). This led to a conclusion that, because the drug does not or only poorly crosses the blood-brain barrier, a selective peripheral antihistamine action may be sufficient in the control of motion sickness induced through cross-coupled accelerative semicircular canal stimulation using a rotating chair. This finding implies that other peripherally acting agents might be found that possess even greater antimotion sickness efficacy. The present research raises additional questions regarding current theories on the etiology of motion sickness, its associated autonomic system dysfunction, and the validity of assumptions that effective pharmacological agents must act centrally.

Kohl, Randall L.↗

Light as a chronobiologic countermeasure for long-duration space operations

Long-duration space missions require adaptation to work-rest schedules which are substantially shifted with respect to earth. Astronauts are expected to work in two-shift operations and the environmental synchronizers (zeitgebers) in a spacecraft differ significantly from those on earth. A study on circadian rhythms, sleep, and performance was conducted by exposing four subjects to 6 deg head-down tilt bedrest (to simulate the effects of the weightless condition) and imposing a 12-h shift (6 h delay per day for two days). Bright light was tested in a cross-over design as a countermeasure for achieving faster resynchronization and regaining stable conditions for sleep and circadian rhythmicity. Data collection included objective sleep recording, temperature, heart rate, and excretion of hormones and electrolytes as well as performance and responses to questionnaires. Even without a shift in the sleep-wake cycle, the sleep quantity, circadian amplitudes and 24 h means decreased in many functions under bedrest conditions. During the shift days, sleepiness and fatigue increased, and alertness decreased. However, sleep quantity was regained, and resynchronization was completed within seven days after the shift for almost all functions, irrespective of whether light was administered during day-time or night-time hours. The time of day of light exposure surprisingly appeared not to have a discriminatory effect on the resynchronization speed under shift and bedrest conditions. The results indicate that simulated weightlessness alters circadian rhythms and sleep, and that schedule changes induce additional physiological disruption with decreased subjective alertness and increased fatigue. Because of their operational implications, these phenomena deserve additional investigation.

Samel, Alexander↗

Design and analysis of filament-wound cylinders in compression

The objective of the study was to develop a more accurate model for the prediction of the compressive behavior of filament-wound composite cylindrical shells. Results from a closed-form analytical model and a three-dimensional finite element model show that the extensional and bending stiffness of the laminate is significantly reduced in tow cross-over regions and that bending-extension coupling is increased in comparison with classical lamination theory. The material properties predicted by a micromechanics analysis are included in a global finite element model of a filament-wound circular cylindrical shell which also incorporates variations in the laminate stacking thickness. Results from the global shell analysis are compared with experimental data.

Hipp, Patrick A.↗

Inverse Compton Scattering in Mildly Relativistic Plasma

We investigated the effect of inverse Compton scattering in mildly relativistic static and moving plasmas with low optical depth using Monte Carlo simulations, and calculated the Sunyaev-Zel'dovich effect in the cosmic background radiation. Our semi-analytic method is based on a separation of photon diffusion in frequency and real space. We use Monte Carlo simulation to derive the intensity and frequency of the scattered photons for a monochromatic incoming radiation. The outgoing spectrum is determined by integrating over the spectrum of the incoming radiation using the intensity to determine the correct weight. This method makes it possible to study the emerging radiation as a function of frequency and direction. As a first application we have studied the effects of finite optical depth and gas infall on the Sunyaev-Zel'dovich effect (not possible with the extended Kompaneets equation) and discuss the parameter range in which the Boltzmann equation and its expansions can be used. For high temperature clusters (k(sub B)T(sub e) greater than or approximately equal to 15 keV) relativistic corrections based on a fifth order expansion of the extended Kompaneets equation seriously underestimate the Sunyaev-Zel'dovich effect at high frequencies. The contribution from plasma infall is less important for reasonable velocities. We give a convenient analytical expression for the dependence of the cross-over frequency on temperature, optical depth, and gas infall speed. Optical depth effects are often more important than relativistic corrections, and should be taken into account for high-precision work, but are smaller than the typical kinematic effect from cluster radial velocities.

Molnar, S. M.↗

Calculations of multiple scattering-induced errors in the GLAS mission

The Geoscience Lidar Altimeter System (GLAS) is a laser altimeter designed to measure temporal changes in the topography and mass balance of the Earth's ice sheets. GLAS is scheduled to be launched as part of the Earth Observing System (EOS) in 2001. Due to the large pulse width of GLAS and the slope (and roughness) of the ice sheets, the mean elevation of the laser's surface spot will be estimated from the centroid of the return pulse. While the accuracy of individual altimetry measurements is expected to be 15 cm, a cross-over technique that averages the elevation differences at selected points on the ice sheets will allow GLAS to detect mean ice elevation changes as small as 2 cm per year. One factor that may degrade the proposed accuracy of the altimeter measurements is the effect of multiple scattering by thin clouds and aerosols over the ice sheets. In the return pulse, some photons from the lidar are slightly deflected by cloud particles but still return to the instrument detector. Since these photons travel a longer path than photons that pass directly to and from the surface, the mean travel time of the pulse is lengthened and the centroid of the return pulse is shifted toward a later time . This study intends to determine the importance of this source of altimetry error in the GLAS measurements. Two methods will be used to estimate path delays in the GLAS lidar for a range of cloud conditions. An analytic expression of a doubly scattered return signal (Eloranta, 1972) will be compared to Monte Carlo simulations that estimate path delays by cloud, aerosol and molecular scattering. The results from both methods will be discussed in relationship to current knowledge of Arctic cloud climatology, and the impact of multiple scattering on GLAS altimeter measurements will be evaluated.

Duda, David P.↗

Space Station power system issues

Issues governing the selection of power systems for long-term manned Space Stations intended solely for earth orbital missions are covered briefly, drawing on trade study results from both in-house and contracted studies that have been conducted over nearly two decades. An involvement, from the Program Development Office at MSFC, with current Space Station concepts began in late 1982 with the NASA-wide Systems Definition Working Group and continued throughout 1984 in support of various planning activities. The premise for this discussion is that, within the confines of the current Space Station concept, there is good reason to consider photovoltaic power systems to be a venerable technology option for both the initial 75 kW and 300 kW (or much greater) growth stations. The issue of large physical size required by photovoltaic power systems is presented considering mass, atmospheric drag, launch packaging and power transmission voltage as being possible practicality limitations. The validity of searching for a cross-over point necessitating the introduction of solar thermal or nuclear power system options as enabling technologies is considered with reference to programs ranging from the 4.8 kW Skylab to the 9.5 gW Space Power Satellite.

Giudici, R. J.↗