Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cryocooler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermal link design for conduction cooling of SRF cavities using cryocoolers

Superconducting radio frequency (SRF) cavities with quality factors ~1010 near 4 K have potential to be cooled using re-generative-cycle cryocoolers. Contrary to using liquid helium, cry-ogen-free operation can be realized by conductively linking a cavity to a cryocooler. The cavity-cryocooler thermal link needs careful design for balancing cooling capacity of the cryocooler with the dissipation rate in the cavity. We present a thermal analysis of a conduction-cooled SRF cavity that identifies the link thermal con-ductance requirement. The analysis uses published or expected RF dissipation characteristics of an Nb3Sn coated niobium cavity and in-house measured cooling capacity of a commercial pulse tube cryocooler. We describe mechanical design of a link that is con-structed using commercial high-purity aluminum and facilitates bolted-connection to elliptical SRF cavities. The thermal perfor-mance of the link is assessed by finite element simulations, taking into account temperature dependent thermal conductivities and measured thermal contact resistance of aluminum and niobium. The link is shown to support operation at an accelerating gradient of 10 MV/m with the lowest-known ‘perfect’ Nb3Sn surface re-sistance (10 nΩ) and also under non-ideal cases that assume certain static heat leak into the system and non-perfect Nb3Sn coatings

43 PARTICLE ACCELERATORS↗

First demonstration of a cryocooler conduction cooled superconducting radiofrequency cavity operating at practical cw accelerating gradients

Abstract We demonstrate practical accelerating gradients on a superconducting radiofrequency (SRF) accelerator cavity with cryocooler conduction cooling, a cooling technique that does not involve the complexities of the conventional liquid helium bath. A design is first presented that enables conduction cooling an elliptical-cell SRF cavity. Implementing this design, a single cell 650 MHz Nb 3 Sn cavity coupled using high purity aluminum thermal links to a 4 K pulse tube cryocooler generated accelerating gradients up to 6.6 MV m −1 at 100% duty cycle. The experiments were carried out with the cavity-cryocooler assembly in a simple vacuum vessel, completely free of circulating liquid cryogens. We anticipate that this cryocooling technique will make the SRF technology accessible to interested accelerator researchers who lack access to full-stack helium cryogenic systems. Furthermore, the technique can lead to SRF based compact sources of high average power electron beams for environmental protection and industrial applications. A concept of such an SRF compact accelerator is presented.

43 PARTICLE ACCELERATORS↗

Development of a cryocooler conduction-cooled 650 MHz SRF cavity operating at ~10 MV/m cw accelerating gradient

SRF cavities for particle acceleration are conventionally operated immersed in a bath of liquid helium at 4.2 K and below. Although this cooling configuration is practically and economically viable for large scientific accelerator installations, it may not be so for smaller accelerators intended for industrial applications such as the treatment of wastewater, sludge, flue gases, etc. In this paper, we describe a procedure to operate SRF cavities without liquid helium that can be used to construct electron-beam sources for industrial applications of electron irradiation (1-10 MeV electron energy). In this procedure, an elliptical single-cell 650 MHz niobium-tin coated niobium cavity is coupled to a closed-cycle 4.2 K cryocooler using high purity aluminum thermal links. The cryocooler conductively extracts heat (RF dissipation) from the cavity without requiring liquid helium around the cavity. We present construction details of this cryocooler conduction-cooling technique and systematic experiments that have demonstrated ~10 MV/m cw gradient on the cavity. By straightforward scaling up the cavity length and number of cryocoolers, the technique will provide the complete range of 1-10 MeV electron energy for industrial applications.

43 PARTICLE ACCELERATORS↗

Modeling the cooldown of cryocooler conduction-cooled devices

Cryocooler conduction cooled devices can experience significant cooldown time due to lower available cooling capacity compares to convection cooled devices. Therefore, the cooldown time is an important design parameter for conduction cooled devices. This article introduces a framework developed in Python for calculating the cooldown profiles and cooldown time of cryocooler conduction-cooled devices such as superconducting magnets and accelerator cavities. The cooldown time estimation problem is essentially a system of ordinary first-order differential equations comprising the material properties (temperature dependent thermal conductivity and specific heat capacity) of the components intertwined with the prevailing heat transfer channels (conduction, radiation, and heat flow across pressed contacts) and the cryocooler capacity. The formulation of this ODE system is first presented. This ODE system is then solved using the in-built Python library odeint. A case study is presented comprising a small cryocooler conduction-cooled copper stabilized niobium-titanium magnet. The case study is supplemented with the Python script enabling the reader to simply tweak the device design parameters and optimize the design from the point of view of slow/fast cooldown.

43 PARTICLE ACCELERATORS↗

Cooling Design and Thermal Analysis for Thermal Shields of a Cryocooler-Cooled Superconducting ECR Ion Source MARS-D Magnet

Here, a demonstrative NbTi based Mixed Axial and Radial field System (MARS-D) is being developed for a next-Generation Electron Cyclotron Resonance Ion Source (ECRIS) at Lawrence Berkeley National Laboratory (LBL), which employs a novel closed-loop coil design scheme that more efficiently utilizes conductor fields and extend the application of NbTi for high frequency (up to 45 GHz) ECR operation. The NbTi MARS-D magnet consists of a single hexagonally shaped closed-loop coil and a set of auxiliary solenoids. A cryostat for cooling the MARS-D magnet is under design at LBL. The MARS-D magnet working around 4.2 K will be bath-cooled in liquid helium using multiple two-stage cryocoolers. An intermediate temperature thermal radiation shield is adopted to reduce the heat leakage imposed on 4.2 K coil cold mass from room temperature. The thermal shield is conduction-cooled by the first-stage cold heads of four two-stage cryocoolers and the cold head of a single-stage cryocooler shared with nine binary leads. The temperature in the area of the shield that warm ends of HTS leads are mounted on is expected no higher than 60 K, which is limited by maximum allowable working temperature of HTS leads. The paper presents thermal analysis on the thermal radiation shield including heat loads and effects of eddy current induced during quench on its material selection.

ECRIS↗

Effects of in-process cryocooling on metallurgical and mechanical properties of friction stir processed Al7075 alloy

Highlights: • For in-process cryocooling (IPC) during FSP, an efficient cooling fixture was designed & fabricated. • FSP of Al7075 alloy with IPC setup suppressed precipitate coarsening as well as grain growth. • Nanosize η′ precipitates (20–30 nm) in IPC condition increased work hardening capacity & strength. • Simultaneous improvement in ductility & strength occurred for sample FSPed with IPC. - Abstract: Friction stir processing (FSP) of heat treatable aluminum alloys is reported to deteriorate strength and hardness properties in spite of huge grain size refinement. The improvement in strength due to the grain size refinement after FSP could not be able to offset the reduction in strength due to coarsening or dissolution of the strengthening precipitate(s). To overcome this, the present work investigates an effective way of heat rejection from the FSP zone to control the precipitate evolution besides the grain size refinement during FSP of Al7075 alloy. The FSP was carried out with standardized process parameters (i.e. 720 rpm, 65 mm/min traverse speed) under two different cooling environments: (i) at normal air cooling and (ii) by rushing a chilled mixture (−30 °C) of liquid nitrogen and methanol through the bottom of the backing plate. Microstructural evolution was examined through optical, scanning and transmission electron microscopy and electron backscatter diffraction to confirm the grain size and morphology of precipitate(s) formed. The in-process cryocooling during the FSP led to 65 and 72% improvement in the Vickers hardness and tensile strength, respectively, in comparison to the solutionized base metal. The results have been analyzed in terms of precipitate interface characteristics and its strengthening effect, Hall–Petch strengthening due to grain size reduction and tradeoff between them.

36 MATERIALS SCIENCE↗

First demonstration of an all-solid-state optical cryocooler

Solid-state optical refrigeration uses anti-Stokes fluorescence to cool macroscopic objects to cryogenic temperatures without vibrations. Crystals such as Yb 3+ -doped YLiF 4 (YLF:Yb) have previously been laser-cooled to 91 K. In this study, we show for the first time laser cooling of a payload connected to a cooling crystal. A YLF:Yb crystal was placed inside a Herriott cell and pumped with a 1020-nm laser (47 W) to cool a HgCdTe sensor that is part of a working Fourier Transform Infrared (FTIR) spectrometer to 135 K. This first demonstration of an all-solid-state optical cryocooler was enabled by careful control of the various desired and undesired heat flows. Fluorescence heating of the payload was minimized by using a single-kink YLF thermal link between the YLF:Yb cooling crystal and the copper coldfinger that held the HgCdTe sensor. The adhesive-free bond between YLF and YLF:Yb showed excellent thermal reliability. This laser-cooled assembly was then supported by silica aerogel cylinders inside a vacuum clamshell to minimize undesired conductive and radiative heat loads from the warm surroundings. Our structure can serve as a baseline for future optical cryocooler devices.

47 OTHER INSTRUMENTATION↗

Cryocooler conduction-cooled SRF cavities for compact particle accelerators

Cryocooler conduction cooling offers simple, reliable cryogenics for developing industrial SRF e-beam accelerators. Conduction-cooled SRF R&D at Fermilab: first demonstration >6.5 MV/m cw on a 650 MHz Nb 3 Sn coated cavity; prototype development and high power accelerators designs in progress. Cryocooler conduction cooling can greatly expand access to SRF: university groups, industries can embark on in house SRF R&D without needing full stack helium cryogenic systems

43 PARTICLE ACCELERATORS↗

Demonstration of CW Accelerating Gradients on a Cryogen-Free Cryocooler Conduction-Cooled SRF Cavity

Conduction-cooling of superconducting radiofrequency (SRF) cavities using closedcycle cryocoolers can lead to compact linear accelerators by eliminating liquid helium and the associated infrastructure. In this paper, we present the first-ever experimental demonstration of continuous wave (cw) accelerating gradients on a niobium SRF cavity that is cooled without using liquid helium. In a newly developed experimental apparatus, a single-cell, 650 MHz niobium cavity was conductively coupled to a 2 W @ 4.2 K pulse tube cryocooler using a high-purity aluminium thermal link. The cw accelerating gradient slightly exceeded 1.5 MV/m, a limit imposed by our RF power supply. Using simple scaling, we project that the niobium cavity when coated with Nb3Sn and operated on the same experimental setup can produce >10 MV/m cw accelerating gradients.

43 PARTICLE ACCELERATORS↗

Development of Pulse Tube Cryocoolers at SITP for Space Application

Over the last 10 years, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, has developed very high-efficiency pulse tube cryocoolers (PTCs) for aerospace applications. These PTCs can provide cooling power from milliwatt scale to tens of watts over a range of temperatures from 30 to 170 K and can be used to cool a variety of detectors in space applications (such as quantum interference devices, radiometers and ocean color sensors) that must operate at a specific cryogenic temperature to increase the signal-to-noise ratio, sensitivity and optical resolution. This paper reviews the development of single-stage PTCs over a range of weights from 1.6 to 12 kg that offer cooling powers at the cold temperature range from 40 to 170 K. In addition, a two-stage 30 K-PTC is under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Low Temperature on a 4 W/60 K Pulse-Tube Cryocooler for Cooling HgCdTe Detector

Temperature is an extremely important parameter for the material of the space-borne infrared detector. To cool an HgCdTe-infrared detector, a Stirling-type pulse-tube cryocooler (PTC) has been developed based on a great deal of numerical simulations, which are performed to investigate the thermodynamic behaviors of the PTC. The effects of different low temperatures are presented to analyze different energy flows, losses, phase shifts, and impedance matching of the PTC at a temperature range of 40–120 K, where woven wire screens are used. Finally, a high-efficiency coaxial PTC has been designed, built, and tested, operating around 60 K after a number of theoretical and experimental studies. The PTC can offer a no-load refrigeration temperature of 40 K with an input electric power of 150 W, and a cooling power of 4 W at 60 K is obtained with Carnot efficiency of 12%. In addition, a comparative study of simulation and experiment has been carried out, and some studies on reject temperatures have been presented for a thorough understanding of the PTC system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multicaloric Cryocooling Using Heavy Rare-Earth Free La(Fe,Si) 13 -Based Compounds

The transition toward a carbon-neutral society based on renewable energies goes hand in hand with the availability of energy-efficient technologies. Here, magnetocaloric cooling is a very promising refrigeration technology to fulfill this role regarding cryogenic gas liquefaction. However, the current reliance on highly resource critical, heavy rare-earth-based compounds as magnetocaloric material makes global usage unsustainable. Here, we aim to mitigate this limitation through the utilization of a multicaloric cooling concept, which uses the external stimuli of isotropic pressure and magnetic field to tailor and induce magnetostructural phase transitions associated with large caloric effects. In this study, La 0.7 Ce 0.3 Fe 11.6 Si 1.4 is used as a nontoxic, low-cost, low-criticality multiferroic material to explore the potential, challenges, and peculiarities of multicaloric cryocooling, achieving maximum isothermal entropy changes up to −28 J (kg K) −1 in the temperature range from 190 K down to 30 K. Thus, the multicaloric cooling approach offers an additional degree of freedom to tailor the phase transition properties and may lead to energy-efficient and environmentally friendly gas liquefaction based on designed-for-purpose, noncritical multiferroic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cryocooler conduction-cooled SRF accelerator design for industrial applications

Principal Investigator Dr. Ram Dhuley has led R&D efforts at the U.S. Department of Energy's Fermi National Accelerator Laboratory to design a cryocooler conduction-cooled SRF accelerator for e-beam irradiation treatment of wastewater. This is a spotlight on the accelerator design and its enabling core technologies.

43 PARTICLE ACCELERATORS↗

Deployable Cryocooler Based Cryomodule

Superconducting Radio Frequency (SRF) linear accelerators (linacs) have shown tremendous promise in extending the intensity frontier of particle accelerator technology. However, they are large and complex systems, requiring a central refrigeration system and complex piping to distribute liquid helium and nitrogen to the accelerating cavities. In response to these problems, RadiaBeam Technologies, LLC. proposes to develop a small mobile cryomodule that can be safely deployed to its planned field location. The scope of this work is to provide RadiaBeam with the specifications for a complete 650 MHz RF cavity model that can be incorporated into a compact SRF accelerator. Fermilab’s contribution will involve sharing contact resistance measurements, design parameters, and solid models. Design parameters will include the cavity frequency and gradient, length of the linac, number of cryocoolers, etc. This will ensure that the design is useful for practical linacs. A complete cryomodule design is envisioned. Radiabeam will design the cryomodule based on input from Fermilab’s experience on conduction cooling and the needs for a compact SRF accelerator.

43 PARTICLE ACCELERATORS↗

Cryocooled cold trap system for the SuperCDMS dilution refrigerator

Operating 6,800 feet underground at the SNOLAB facility in Sudbury, Ontario, Canada, the dilution refrigerator-cooled SuperCDMS SNOLAB (Super Cryogenic Dark Matter Search at the Sudbury Neutrino Observatory Laboratory) experiment has been designed for maximum cryogenic up-time and remote operations. A key element in achieving these goals is a pair cold traps in the helium circulation stream of the dilution refrigerator; the first operating near liquid nitrogen temperatures and the second operating near liquid helium temperatures. Previous experience with the CDMS experiment, located underground at the Soudan Under-ground Laboratory, has given significant operational experience with dilution refrigerator cold traps and has solidified the demand of a system of dual cold traps. Unlike the CDMS-era system, the new SuperCDMS system will feature a cryocooler powered liquid nitrogen re-liquefying system (as opposed to regular under-ground re-filling of cold trap dewars using portable nitrogen dewars) and a cryogen-free 4 K cold trap, which eliminates the need for a bath of liquid helium.

43 PARTICLE ACCELERATORS↗

Rapid Cryogenic Electrical Characterization of Materials and Devices Using Gifford-McMahon Cryocoolers

Thin-film heterostructures are necessary building blocks for superconducting and phononic quantum computing devices. Many new generations of quantum hardware demand extensive materials research to optimize performances at cryogenic temperatures (below 10 K). Here, we demonstrate compact cryogenic measurement systems capable of reaching sub-10K temperatures in less than three hours with the ability to measure AC/DC resistance and dielectric properties of thin-film materials. Our platform utilizes Gifford-McMahon (GM) cryocoolers as effective tools for providing high throughput cooling-warming cycles. We successfully used the GM-based measurement systems to measure 1) the superconducting transition temperature for Nb thin films (T c ~7.8 K), and 2) the temperature dependence of the dielectric constant in SiO 2 thin films down to 10 K. The fast electrical characterization feedback will be critical in developing robust materials and components for cryogenic computing devices.

36 MATERIALS SCIENCE↗