Search NASASearch

SEARCH · Search NASA

Results for “Cryocooler PLANCK hydrogen sorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Evaluation of hydride compressor elements for the Planck sorption cryocooler

Hydrogen sorption crycoolers are being developed for the European Space Agency Planck mission to provide nominal 19 K cooling to instruments for measuring the temperature anisotropy of the cosmic microwave background with extreme sensitivity and resolution.

sorption cryocoolers metal hydides gas gap heat sw

Hydrogen Sorption Cryocoolers for the Planck Mission

Two continuous opertation 18K/20K sorption coolers are being developed by the Jet Propulsion Laboratory (JPL) as a NASA contribution to the European Space Agency (ESA) Planck mission that is currently planned for a 2007 launch.

Cryocooler sorption coolers

Performance, reliability and life issues for components of the Planck Sorption Cooler

Continuous-duty hydrogen sorption cryocoolers are being developed for the European Space Agency (ESA) Planck mission. To achieve an acceptable level of performance and robust operation with these hydride refrigerators during flight, detailed investigations have been performed on the sorbent materials and on critical hardware components.

sorption

Sorption coolers using a continuous cycle to produce 20 K for the Planck flight mission

Two sorption coolers using hydrogen as the working fluid are currently being fabricated and assembled for flight delivery by the Jet Propulsion Laboratory (JPL). Being vibration free, scalable and with the capability for the cold end to be remotely located from the warm spacecraft are the major advantages of this class of cryo-coolers. These systems have been designed to provide a total cooling capacity (per cooler) of 1 W at a cold end temperature less than 19 K. They will be used for the Planck surveyor mission (2007 launch). In this paper we present the level Of maturity of the hydrogen sorption cooler technology at JPL by describing the design and how it has been validated at the subsystem and system levels.

sorption

The Planck Sorption Cooler: Using Metal Hydrides to Produce 20 K

The Jet Propulsion Laboratory has built and delivered two continuous closed cycle hydrogen Joule-Thomson (JT) cryocoolers for the ESA Planck mission, which will measure the anisotropy in the cosmic microwave background. The metal hydride compressor consists of six sorbent beds containing LaNi4.78Sn0.22 alloy and a low pressure storage bed of the same material. Each sorbent bed contains a separate gas-gap heat switch that couples or isolates the bed with radiators during the compressor operating cycle. ZrNiHx hydride is used in this heat switch. The Planck compressor produces hydrogen gas at a pressure of 48 Bar by heating the hydride to approx.450 K. This gas passes through a cryogenic cold end consisting of a tube-in-tube heat exchanger, three pre-cooling stages to bring the gas to nominally 52 K, a JT value to expand the gas into the two-phase regime at approx.20 K, and two liquid - vapor heat exchangers that must remove 190 and 646 mW of heat respectively.

hydrogen storage materials

Cryogenic testing of Planck sorption cooler test facility

A test facility has been upgraded in preparation for testing of two hydrogen sorption cryocoolers operating at 18/20 K. these sorption coolers are currently under development at the Jet Propulsion Laboratory. This work summarizes the scope of the test facility upgrade, including design for cryogenic cooling power delivery, system thermal management, insulation schemes, and data acquisition techniques. Ground support equipment for the sorption coolers, structural features of the test chamber, and the vacuum system involved for system testing will also be described in detail.

Planck sorption cooler