Optimisation of a multi-disk cryogenic amplifier for a high-intensity, high-repetition-rate laser system

Holders of the active elements of a multi-disk multipass amplifier with a liquid-free closed cryogenic cooling cycle are modified. The equilibrium temperature of the active elements is experimentally investigated in relation to the power of diode pumping for the modified crystal holders. The dependence of the gain coefficient on the temperature of the active elements is measured. A small-signal gain of up to 1.2 is obtained in a single pass through the active element. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of FD-SOI cryogenic amplifier for application to STJ readout in COBAND project

The COBAND is a project of an experimental search for the cosmic background neutrino decay [1] – [9] . The existence of the cosmic background neutrino is predicted as a relic of the big bang in the theoretical cosmology. Since the neutrino is found to have mass generations and mixing between them, a heavier neutrino is possible to decay to a lighter neutrino with a far-infrared photon, even though its lifetime is expected to be much longer than the age of the universe [10] . However, neither the cosmic background neutrino nor the neutrino decay is yet established experimentally. Only a lower limit in the order of 10 12 years is given on the heaviest neutrino lifetime. We, thus, search for photons which come from the cosmic background neutrino decays. The photons from the cosmic background neutrino decays are expected to shape a spectrum of a unique signature with a sharp edge at a wavelength of around 50μm depending on the heaviest neutrino mass. To identify the signature against the overwhelming zodiacal emission foreground as well as the cosmic infrared background, the photodetectors are required to have an ability to measure the FIR spectrum around 50pm with sufficient precision. Thus, we aim at developing a photodetector with capability of FIR photon-by-photon spectrometry. We employ superconducting tunnel junction (STJ) sensors in combination with cryogenic amplifiers for signal readout to maximize the potential of STJ.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contactless method for studying temperature within the active element of a multidisk cryogenic amplifier

A new original method has been developed and experimentally implemented, allowing temperature fields to be contactlessly measured in the pump region of active elements in high-power-diode-pumped laser amplifiers, including those operating at cryogenic temperatures. The presence of a temperature gradient of ∼57 K mm{sup −1} along the pump beam axis at the centre of the active element of the laser amplification unit operating at cryogenic temperatures with a pulse repetition rate up to 1 kHz is simulated and experimentally confirmed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear thermally induced distortions of a laser beam in a cryogenic disk amplifier

Taking into account the temperature dependences of the heat conductivity, the refractive index, and the thermal expansion coefficient, we calculated the temperature, elastic stresses, a thermally induced lens and depolarisation of a beam in a cryogenic disk amplifier (an Yb:YAG disk placed between a copper cylinder and a sapphire disk cooled by liquid nitrogen). When the active element (the thickness is 0.6 mm, the orientation is [001], the atomic concentration of Yb is 10%) is pumped by radiation from a diode laser (the beam diameter is 6 mm), the temperature does not exceed 140 K for the heat release power of 100 W. In this case, elastic stresses in the active element are six times lower than the maximum permissible value. The focal distance of the thermally induced lens is 5.5 m and the depolarisation rate is 0.038% per two passes through the active element. Although the heat conductivity of the active element rapidly decreases with temperature, the thermal load can be increased by 1.5-2 times when the dimensions of the active element remain constant. (active media)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

Low-Noise Amplifiers and Superconducting Flex Circuits for Frequency Domain Multiplexed Readout of Detector Arrays

The next-generation ground-based cosmic microwave background (CMB) experimental program aims to provide definitive measurements of the early universe using telescopes configured with large focal plane arrays requiring ~100,000 detectors and associated readout amplifiers and interconnecting components that are currently unavailable commercially. We describe research to demonstrate the feasibility of developing low-noise cryogenic amplifiers based on series SQUID arrays that are suitable for frequency domain multiplexed readout of large numbers of CMB detectors, and the feasibility of developing robust superconducting flex cables that will simplify cryogenic systems integration for large CMB instruments. Two iterations of prototype series SQUID array amplifier designs were completed. The designs were optimized using modeling and simulation tools to meet the requirements for CMB detector readouts. Two fabrication runs were completed, and a large number of devices from each design iteration were tested and characterized at 4 K. We also completed the development of processes for the fabrication of prototype superconducting flex cables on 4" wafers. Samples were tested for strength and robustness, and to determine the critical current at 4 K as a function of trace width. The new generation of series SQUID array amplifier designs exhibit excellent performance characteristics – very smooth output characteristics that simplify tuning and operation, low input inductance, low current noise referred to the input, and low power dissipation that for the first time will enable these devices to be operated at the focal plane array stage of CMB instruments. The processes developed in Phase I to produce superconducting flex cables were used to complete the fabrication of a full wafer with several test and sample flex circuits. The 6-micron thick flex material is very strong with a breaking strength of several pounds for a 20-mm wide strip. Critical current density was reasonable and scaled with trace width as expected.

79 ASTRONOMY AND ASTROPHYSICS↗

Progress on Frequency-Domain Multiplexing Development for High Count rate X-ray Microcalorimeters

Frequency-domain multiplexing is one of the candidates for the readout of TES-based imaging microcalorimeter arrays for applications such as IXO. The readout system uses the TES as the modulating element, a bandpass LC filter to separate the signals in frequency space, and a customized SQUID with a low input inductance and high dynamic range as cryogenic amplifier. We will show the latest experimental progress on the development of this system. The paper concentrates on our first results on multiplexing 2-7 channels at bias frequencies below 5 MHz using discrete LC filters and baseband feedback electronics. In addition to that, the scalability of the system will be addressed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-noise kinetic inductance traveling-wave amplifier using three-wave mixing

We have fabricated a wide-bandwidth, high dynamic range, low-noise cryogenic amplifier based on a superconducting kinetic inductance traveling-wave device. The device was made from NbTiN and consisted of a long, coplanar waveguide on a silicon chip. By adding a DC current and an RF pump tone, we are able to generate parametric amplification using three-wave mixing (3WM). The devices exhibit gain of more than 15 dB across an instantaneous bandwidth from 4 to 8 GHz. The total usable gain bandwidth, including both sides of the signal-idler gain region, is more than 6 GHz. The noise referred to the input of the devices approaches the quantum limit, with less than 1 photon excess noise. We compare these results directly to the four-wave mixing amplification mode, i.e., without DC-biasing. We find that the 3WM mode allows operation with the pump at lower RF power and at frequencies far from the signal. We have used this knowledge to redesign the amplifiers to utilize primarily 3WM amplification, thereby allowing for direct integration into large scale qubit and detector applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of Hamamatsu VUV4 SiPMs for detecting liquid argon scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this paper, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7 +1.1 -2.4 % and 17.2 +1.6 -3.0 % at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Hamamatsu VUV4 SiPM Performance for Liquid Argon Scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this article, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Here, using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7+1.1–2.4% and 17.2+1.6–3.0% at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

Pershing, Teal↗

High-efficiency WSi superconducting nanowire single-photon detectors operating at 2.5 K

We investigate the operation of WSi superconducting nanowire single-photon detectors (SNSPDs) at 2.5 K, a temperature which is ∼70% of the superconducting transition temperature (T{sub C}) of 3.4 K. We demonstrate saturation of the system detection efficiency at 78 ± 2% at a wavelength of 1310 nm, with a jitter of 191 ps. We find that the jitter at 2.5 K is limited by the noise of the readout and can be improved through the use of cryogenic amplifiers. Operation of SNSPDs with high efficiency at temperatures very close to T{sub C} appears to be a unique property of amorphous WSi.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser and thermal characteristics of Yb : YAG crystals in the 80 - 300 K temperature range

The spectral and thermooptical characteristics of an Yb : YAG crystal were measured in the 80 - 300 K temperature range. On cooling the crystal, the amplification cross section increases fivefold, the peak of the cross section spectrum shifts from 1030.1 to 1029.3 nm, and its width lowers from {approx}10 to 1.3 nm. These effects must be taken into account when operating with cryogenic amplifiers. Also measured were thermooptical constants P and Q as well as the photoelastic anisotropy parameter. These material constants completely determine the thermal and phase polarisation distortions in an active element when the heat release and the thermal conductivity coefficient are known. The thermoinduced depolarisation was shown to lower by a factor of 1000 and the optical strength by a factor of 50 on cooling the Yb : YAG crystal to a temperature of 78 K. (active media)

36 MATERIALS SCIENCE↗

NECQST: Novel Electronics for Cryogenic Quantum Sensors Technology

Development of low-noise cryogenic readout circuits for SNSPDs based on state-of-the art, commercially available SiGe HBT technology, operating at a range of 1-4 Kelvin. Targeting a reduction of the timing jitter of SNSPDs (from the current record of 2.7 ps FWHM at 400 nm), and a reduction in the power dissipation allowed by the development of dedicated low-noise cryogenic amplifiers, which will enable the scaling of ultra-low-jitter SNSPDs to large arrays. Such performance advances will directly benefit the Caltech/Fermilab INQNET (Intelligent Quantum Networks & Technologies) program, which aims to demonstrate high-rate quantum communication at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Superconducting Tunnel Junction Far-Infrared Photon Detector for Cosmic Background Neutrino Decay Search - COBAND experiment

We present the status of development of the Superconducting Tunnel Junction (STJ) detector for the COsmic BAckground Neutrino Decay search (COBAND) experiment. The signal of the cosmic background neutrino decay is identified as a sharp cutoff at high energy end in a far-infrared region ranging from 15meV to 30meV in the energy spectrum of the photons from the space. The COBAND experiment will be done as rocket and satellite experiments in order to detect the far-infrared photons from the space. For the photon detector of the COBAND experiment, we are developing the STJ detectors. We will use a combination of the diffraction grating and the array of Nb/Al-STJ pixels with cryogenic amplifier for the rocket experiment, and use Hf-STJ without a grating for the future satellite experiment. The present status of the detector R&D and the experimental design for the COBAND experiment is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗