RHIC Recovery Review Report [See also: RHIC Recovery Review - Hybrid Meeting (11/28/2023) - Indico.bnl.gov]

Just after 12:30 PM on August 1, 2023, the RHIC superconducting magnet quench system triggered and consequently the energy dump resistors were switched into the blue ring quad and dipole circuits and the interaction region DX dipole heaters were switched on. This was a spurious trip (there was no actual quench) and was not unusual as the outdoor summer temperature often caused the quench detectors to cause such trips. The collider control room notified the on-duty cryogenics technical staff of the quench trip. A short time later building 1004B cryogenic low-helium and valve box insulation vacuum failure alarms were observed. The cryogenics technical staff observed the cryo-relief line from the blue ring valve box was exhausting helium outside the building.

43 PARTICLE ACCELERATORS↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vesse l relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision measurement of the magnetic field in run 1 of the g-2 experiment

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

43 PARTICLE ACCELERATORS↗

PIP-II Linac Cryogenic Distribution System Design Challenges

The PIP-II linac Cryogenic Distribution System (CDS) is characterized by extremely small heat inflows and robust mechanical design. It consists of a Distribution Valve Box (DVB), Intermediate Transfer Line, Tunnel Transfer Line, comprising 25 Bayonet Cans, and ends with a Turnaround Can. Multiple helium streams, each characterized by distinct helium parameters, flow through each of these elements. The CDS geometry allows maintaining an acceptable pressure drop for each helium stream, considering the planned flows and helium parameters in different operation modes. This is particularly crucial for the return line of helium vapors, which return from cryomodules to the cold compressors and thus have very restrictive pressure drop requirements. On both sides of the DVB there are fixed supports for process pipes. One of the DVB design challenges was to route the process pipes in such a way that their shape provided sufficient compensation for thermal shrinkage. This ensures th at the forces resulting from thermal shrinkage acting on the cryogenic valves remain at a level acceptable to the manufacturer. The required thermal budget of the CDS was achieved by thermo-mechanical optimization of its components, like process pipes fixed supports in Bayonet Cans.

43 PARTICLE ACCELERATORS↗

Overview and status of the Long-Baseline Neutrino Facility Far Site cryogenics system

The Sanford Underground Research Facility (SURF) will host the Far Detector of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about one and a half kilometers underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The cryogenics infrastructure supporting this experiment is provided by the Long-Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout, and main features of the LBNF Far Site cryogenic system, which is composed of three subsystems: Infrastructure, Proximity, and Internal cryogenics. The Infrastructure cryogenics supports the needs of the cryostat and Proximity cryogenics. It includes the equipment to receive the argon in liquid phase, vaporize it and transfer it underground as a gas, the nitrogen system (composed of the refrigeration system, liquid nitrogen buffer tanks and liquid and gaseous nitrogen distribution), liquid and gaseous argon distribution and process controls. The Proximity cryogenics receives fluids from the Infrastructure cryogenics and delivers them to the Internal cryogenics at the required temperature, pressure, purity and mass flow rate. It includes the argon condensers, liquid and gaseous argon purification and regeneration systems, nitrogen and argon phase separators, piping, valves, and instrumentation. The Internal cryogenics comprises the liquid and gaseous argon distribution inside the cryostats for the commissioning, cool down, fill, and steady state operations of the cryostats and detectors. An international engineering team is designing these systems and will manufacture, install, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Site cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.

43 PARTICLE ACCELERATORS↗

Preliminary design of a helium cryogenic system for SAND detector at LBNF-DUNE near site

The Long-Baseline Neutrino Facility (LBNF) is providing a helium cryogenic system to support the superconducting solenoid magnet of the System for on-Axis Neutrino Detection (SAND) for the Deep Underground Neutrino Experiment (DUNE) Near Site at Fermilab in Batavia, IL. The design started in 2020 and construction is set to begin in the mid 2020‘s.The helium cryogenic system primarily consists of a helium refrigerator system, distribution valve boxes, vacuum-jacketed helium and nitrogen transfer lines, warm gaseous helium transfer system, instruments and control system, and gaseous helium storage tanks. It is designed to provide supercritical helium at around 3 bara and 5 K with expansion from 3 to 1.2 bara in the SAND cryostat and 70K forced cold gas helium to cool the thermal shields of the SAND cryostat. The SAND superconductive magnet is indirectly cooled through a liquid helium thermosiphon cycle. A pair of 3 kA leads is cooled by the gas helium vaporized from the liquid helium reservoir in the cryostat turret. The helium system will share the liquid nitrogen tank and liquid nitrogen phase separator with the Near Site Liquid Argon system. The helium recycle compressor system, GHe tanks and LN2 tank will be located on the Surface. The cryogenic facilities including refrigerator cold box, valve boxes and LN2 phase separator will be located on the shaft cryo-mezzanine in the underground cavern. The shaft connecting surface and cavern is more than 60 meter deep. The helium vacuum-jacketed transfer line between the cold box and the SAND magnet is more than 50 meter long. This paper presents the preliminary design of the helium cryogenic system including the design scheme, process flow diagram, heat load estimates, layout plan and so on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated cryogenic refilling system

An improved system and method for the automated refilling of cryogenic helium is provided. In one embodiment, the system includes a dewar in fluid communication with a liquid helium cryostat through a cryogen transfer line. A controller regulates operation of a three-way valve to pre-cool the transfer line and to cause gaseous helium to flow to the dewar and force liquid helium through the transfer line into the cryostat. The controller is coupled to the output of a cryogenic level sensor, such that the controller regulates the helium liquid level within the cryostat. During filling cycles, the dewar liquid level is also monitored by the cryogenic level sensor and an alarm sounds if the dewar liquid level is undesirably low. Between filling cycles, the controller is operable to ventilate the dewar through a solenoid vent valve in fixed time intervals to ensure the dewar pressure is sufficiently low so as to not bleed liquid helium into the cryostat.

Ruiz-Rodriguez, Mariano M.↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

The increase over the last years of the testing activities related to quantum systems, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4 kL Dewar and two Mycom ® compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair ® compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three control valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two Dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

43 PARTICLE ACCELERATORS↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

aThe increase over the last years of the testing activities related to superconducting quantum materials, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4kL Dewar and two Mycom compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three regulatory valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Two-Phase Dense Fluid Expander for Advanced Cryogenic Air Separation and Low-Grade Heat Recovery

Cryogenic air separation represents the state-of-the-art technology to produce oxygen to feed coal gasification units. Given the maturity of this technology, it is difficult to identify opportunities to improve process efficiency and reduce the cost of the oxygen produced. However, Air Products conducted research and a feasibility investigation into the use of a two-phase (liquid-vapor) dense fluid expander (DFE) to improve the overall efficiency of cryogenic air separation. Demonstration of this novel concept was intended to allow two important process improvements: 1) elimination of the need for the DFE discharge to be single phase 2) expansion of the operating region of expanders in ASU service. Expanding the scope of turboexpander application beyond current application limits and traditional device designs would allow an increase in power recovery, and application of refrigeration and power recovery at new locations in process cycles would also enable the implementation of new process concepts. These new process concepts include power recovery from compression waste heat and refrigeration extraction and power recovery by replacing let-down valves with two-phase DFEs. Considering the maturity of cryogenic air separation, these new process options could represent a step change in power reduction and provide significant savings in operating costs. These new concepts would be particularly well-suited to large-scale oxygen production by cryogenic air separation and would enhance the economics of producing oxygen for use in coal gasification processes. Rotoflow, an Air Products business unit, manufactures dense fluid expanders in Pennsylvania for sites around the world. This project was executed in two phases, which are illustrated in Figure 1 below. Phase 1 consisted of a feasibility investigation of multiple applications of two-phase DFEs. In Phase 2, devices were identified, designed, fabricated and tested to explore the feasibility of commercial applications of DFEs operating in two-phase service. Engineering and testing were performed by personnel in Air Products’ Rotoflow business unit, with coordination with other Air Products business units.

01 COAL, LIGNITE, AND PEAT↗

Impact of breech geometry and propellant flow on the release of large pellets for the ITER disruption mitigation system

Studies have been performed on the release mechanism for large pellets using high pressure gas in a shattered pellet injector. Typically, pellets are dislodged from the cryogenic surface and accelerated down a barrel using high pressure gas delivered by a fast-acting propellant valve. The pellets impact an angled surface which shatters the pellet into many small fragments before entering the plasma. This technique was initially demonstrated on DIII-D (Commaux et al 2016 Nucl. Fusion 56 046007) and is now deployed on JET, KSTAR, ASDEX-Upgrade, and other tokamaks around the world in support of ITER's disruption mitigation system design and physics basis. The large hydrogen, 28.5 mm diameter, 2 length-to-diameter ratio, pellets foreseen for ITER SPI operation have low material strength and low heat of sublimation, which cause the pellets to be fragile and highly reactive to the impact of warm propellant gas. Due to the size of the pellets, significantly more propellant gas is required to dislodge and accelerate them. This creates a potentially significant propellant gas removal issue as 2–6 bar-L of gas is expected to be required for release and speed control. The research presented in this paper is an in-depth exploration of the parameters that are keys to reliable pellet release and speed control. Computational fluid dynamics (CFD) modeling of propellant flows through various breech designs was conducted to determine the force generated on the back surface of a pellet. These simulations assumed the use of the ORNL designed flyer plate valve. CFD modeling combined with experimental measurements provide adequate insight to determine a path to an optimal valve and breech design for ITER SPI pellet release and speed control while minimizing propellant gas usage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monitoring Helium Cryogen Usage with iFix Software at IB1 Test Facility

At the IB1 facility of the Applied Physics and Superconducting Technology Directorate within the Cryogenic Division at Fermilab, Liquid Helium is essential to the testing activities. The test stands require large amounts of Helium to test the thermal and superconducting cavities and magnets. The Liquid Helium that enters the test stand is monitored through a series of valves and controls to determine the start and stop for monitoring time. There are 3 phases of cryogen usage that must be considered for each stand, cooldown, warming and overnight mode. With a new system in place, cold hour tracking will be more objective and precise within each test stand ensuring better calculations for User s fees which are charged to various groups that employ the facility and aid replenishment of Helium and continual operation at IB1.

Trillo, Angelica↗

Monitoring Helium Cryogen Usage with iFix Software at IB1 Test Facility

At the IB1 facility of the Applied Physics and Superconducting Technology Directorate within the Cryogenic Division at Fermilab, liquid helium is essential to the testing activities. The test stands used require large amounts of Helium to test the thermal and superconducting cavities and magnets. The liquid helium that enters the test stand is monitored through a series of valves and controls to determine the start and stop for monitoring time. There are 3 phases of cryogen usage that must be considered for each stand, cooldown, warming and overnight mode. With a new system in place, cold hour tracking will be more objective and precise within each test stand ensuring better calculations for user s fees that will provide funding for the replenishment of helium and continual operation at IB1.

Trillo, Angelica↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyzes heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool’s capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, Rosalyn [Fermilab]↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗