Implementation of Pfirsch–Schlüter parallel flow in x-ray imaging crystal spectrometer inversion analysis

The x-ray imaging crystal spectrometer (XICS) tomographic inversion code for Wendelstein 7-X (W7-X) has been modified to consider the effects of parallel flows and has been applied to analyze measurements taken during recent experimental campaigns. Previous analysis neglected the effects of parallel flows due to the primarily perpendicular geometry of the sightlines and the small magnitude predicted by neoclassical theory. To reconsider these effects, the incompressibility condition for plasma flows is used to calculate the parallel Pfirsch–Schlüter flow component for the equilibrium configuration. By incorporating this condition along with the geometry of the sightlines—i.e. the fractional contributions of perpendicular and parallel flows—, an updated expression for the measured flow is used for the profile inversion. Application of this modified inversion code to data from W7-X shows that the magnitude of the radial electric field and the flux surface averaged perpendicular flow are reduced by approximately a factor of 2 and brought into better agreement with neoclassical predictions and charge exchange recombination spectroscopy measurements.

Pfirsch–Schlüter flows↗

A new hue capturing technique for the quantitative interpretation of liquid crystal images used in convective heat transfer studies

A new image processing based color capturing technique for the quantitative interpretation of liquid crystal images used in convective heat transfer studies is presented. This method is highly applicable to the surfaces exposed to convective heating in gas turbine engines. It is shown that, in the single-crystal mode, many of the colors appearing on the heat transfer surface correlate strongly with the local temperature. A very accurate quantitative approach using an experimentally determined linear hue vs temperature relation is found to be possible. The new hue-capturing process is discussed in terms of the strength of the light source illuminating the heat transfer surface, the effect of the orientation of the illuminating source with respect to the surface, crystal layer uniformity, and the repeatability of the process. The present method is more advantageous than the multiple filter method because of its ability to generate many isotherms simultaneously from a single-crystal image at a high resolution in a very time-efficient manner.

Camci, C.↗

Method for acquiring, storing and analyzing crystal images

A system utilizing a digital computer for acquiring, storing and evaluating crystal images. The system includes a video camera (12) which produces a digital output signal representative of a crystal specimen positioned within its focal window (16). The digitized output from the camera (12) is then stored on data storage media (32) together with other parameters inputted by a technician and relevant to the crystal specimen. Preferably, the digitized images are stored on removable media (32) while the parameters for different crystal specimens are maintained in a database (40) with indices to the digitized optical images on the other data storage media (32). Computer software is then utilized to identify not only the presence and number of crystals and the edges of the crystal specimens from the optical image, but to also rate the crystal specimens by various parameters, such as edge straightness, polygon formation, aspect ratio, surface clarity, crystal cracks and other defects or lack thereof, and other parameters relevant to the quality of the crystals.

Gester, Thomas E.↗

Modeling and Control of Liquid Crystal Imager

In this paper, we present some ideas regarding the modeling and the control aspects of liquid crystal-based imaging systems. We address the challenges of building and deploying a liquid crystal imager by: a) considering the dynamics and control aspects, such as pointing and wavefront error control of large lightweight apertures synthesized by liquid crystal elements, and b) conducting experimental characterization of a prototype electrically-switchable liquid crystal lens.

Quadrelli, Marco B.↗

X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers

X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9–4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. Here, in this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα 1 and Kα 2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser Schlieren Crystal-Growth Imager

Crystal observed as it grows from melt with aid of laser schlieren imaging. Observation method allows entire perimeter of growing crystal to be inspected. Isolated crystal facets examined, convection flows and temperature and concentration gradients revealed. Method does not require contact with, or proximity to, crystal.

Owen, R. B.↗

Wavelength tunable liquid crystal imaging filters for remote sensing from geosynchronous platforms

Recent advances in liquid crystal technology have enabled us to construct tunable birefringent filters with bandwidths between approximately 0.1 nm and 50 nm. The center wavelength of these filters can be selected electronically, in a few tens of milliseconds, with no moving parts. These liquid crystal tunable filters (LCTF's), together with existing CCD detectors, make possible a new generation of lightweight, rugged, high-resolution imaging spectrophotometers. Such instruments would be particularly interesting for remote sensing applications from geosynchronous platforms. Important advantages exist in the aperture, absence of image shift, power consumption, size, weight, and absence of high drive frequencies, compared to current instruments used or considered for multispectral scene analysis. In the present work, we have reviewed spectral requirements of planned NASA geosynchronous remote sensing missions and identified several applications of the liquid crystal tunable filter technology. We have modeled the LCTF performance in the visible and near-infrared, and carried out a literature study on space-hardening of the filter components, to evaluate the suitability of LCTF's for geosynchronous missions. We have also compared the power consumption, weight, size, reliability, and optical performance of an imaging spectrophotometer using a LCTF monochromator, to other instruments that have been put forward for remote sensing from geosynchronous platforms. We put forward some conceptual designs for LCTF's that seem to offer important reliability, over the mechanical filter wheels presently baselined for the HEPI and ALM experiments. The extremely wide acceptance angle achievable with LCTF's could also avoid the present need for large-aperture interference filters in the ALM (and LIS) experiments. Thermal vacuum testing and radiation damage analysis is required to investigate the space hardening of these new filters for geosynchronous flight.

Foukal, Peter↗

Cylindrical Crystal Imaging Spectrometer (CCIS) for cosmic X-ray spectroscopy

A "stigmatic" focusing, Bragg crystal spectrometer was developed and used for high spectral resolution X-ray emission line diagnostics on hot laboratory plasmas. The concept be applied at the focal plane of an orbiting X-ray telescope where it offers several advantages over conventional spectrometers, i.e., mechanical simplicity, high resolving power and sensitivity, simultaneous measurement of an extended segment of spectrum, and good imaging properties. The instrument features a simple, unambiguous, non-scanning spectrum readout that is not adversely affected by either spacecraft pointing error or source extent. The performance of the instrument is estimated in the context of the Advanced X-Ray Astrophysical Facility mission.

Schnopper, H. W.↗

High-resolution bandpass x-ray imaging with crystal reflectors: Overcoming geometric aberrations

The imaging problem of a specular reflector is revisited. Retaining terms through the second order in the reflector surface expansion, we derive the form of the aberration-limiting aperture for arbitrary magnification, assuming no bandwidth limitations. A permissible relative aperture size of the reflector is limited by a set relative aberration tolerance and scales with the tangent of the central glancing angle of incidence. These limiting aberrations become practically insignificant near backscattering. The results extend to x-ray diffracting crystals in symmetric Bragg geometry shaped as an ellipsoid of revolution. This geometry permits polychromatic imaging for hard x-rays over a bandwidth defined by the accepted range of Bragg angles, thereby suppressing aberrations of higher orders. We assess ellipsoidal crystal imagers using ray tracing simulations for two high-magnification designs with Bragg angles far from and close to backscattering. Finally, in both cases, the ellipsoidal crystals produce images of higher quality compared to those formed by equivalent toroidal crystal imagers.

Bragg reflection↗

Improved high-resolution mapping of phase-matching conditions in second-order nonlinear crystals via imaging

Large-aperture nonlinear crystals for frequency conversion and parametric amplification exhibit spatial variations in phase-matching conditions, which affect the performance of high-power laser systems. We demonstrate significant improvements in speed and resolution to a technique that spatially maps these phase-matching conditions using imaging of the beam resulting from detuned second-harmonic generation. The phase-matching conditions at the pyramidal sector boundary of partially deuterated potassium dihydrogen phosphate (DKDP) are mapped with sub-0.1-mm resolution. We examine the effect of further increases in scan rate on the precision of the technique and demonstrate a scan rate of 0.8 cm 2 per minute at the aforementioned resolution.

Wampler, R. [Univ. of Rochester, NY (United States↗

Streaking images that appear only in the plane of diffraction in undoped GaAs single crystals: Diffraction imaging (topography) by monochromatic synchrotron radiation

Streaking images restricted to the direction of the diffraction (scattering) vector have been observed on transmission through undoped GaAs. These disruption images (caused by the reduction of diffraction in the direction of observation) appear both in the forward and in Bragg diffracted directions in monochromatic synchrontron radiation diffraction imaging. This previously unobserved phenomenon can be explained in terms of planar defects (interfaces) or platelets which affects the absorption coefficient in anomalous transmission. Such regions of the crystal look perfect despite the presence of imperfections when the scattering vector is not perpendicular to the normal of the platelets. The observed crystallographic orientation of these interfaces strongly indicates that they are antiphase boundaries.

Kuriyama, Masao↗

High resolution synchrotron X-radiation diffraction imaging of crystals grown in microgravity and closely related terrestrial crystals

Irregularities in three crystals grown in space and in four terrestrial crystals grown under otherwise comparable conditions have been observed in high resolution diffraction imaging. The images provide important new clues to the nature and origins of irregularities in each crystal. For two of the materials, mercuric iodide and lead tin telluride, more than one phase (an array of non-diffracting inclusions) was observed in terrestrial samples; but the formation of these multiple phases appears to have been suppressed in directly comparable crystals grown in microgravity. The terrestrial seed crystal of triglycine sulfate displayed an unexpected layered structure, which propagated during directly comparable space growth. Terrestrial Bridgman regrowth of gallium arsenide revealed a mesoscopic structure substantially different from that of the original Czochralski material. A directly comparable crystal is to be grown shortly in space.

Steiner, Bruce↗

High resolution diffraction imaging of crystals grown in microgravity and closely related terrestrial crystals

Irregularities found in three crystals grown in space, in four crystals grown entirely on the ground were examined and compared. Irregularities were observed in mercuric iodide, lead tin telluride, triglycine sulfate, and gallium arsenide by high resolution synchrotron x radiation diffraction imaging. Radiation detectors made from mercuric iodide crystals grown in microgravity were reported to perform far better than conventional detectors grown from the same material under full gravity. Effort is now underway to reproduce these 'space' crystals, optimize their properties, and extend comparable superiority to other types of materials.

Steiner, B.↗

Characterization of Optical Lenses to be Considered for the Imaging of Crystal Dendrite Growth

Dynamic fracture is a phenomenon that is extremely sensitive to small perturbations in system parameters. This phenomenon is, in some ways, similar to that of dendritic crystal growth, although it is governed by different physical principles. Crystal dendrite growth patterns are affected by parameters such as temperature, pressure, and gravity. By studying the behavior of crystal dendrites in a controlled, microgravity environment, a greater understanding of dynamic fracture could be revealed. A sealed cubical container contains four stingers, which facilitate the growth of crystal dendrites. The container has five windows and is emersed in a liquid, for thermal isolation. The tip of a dendrite can advance in any direction, therefore three-dimensional images of the process are desired. Furthermore, because of the rapid growth rate, a fast image frame rate is required for accurate tracking of dendrite tip velocity. In addition, optical parameters such as field of view, depth of focus, and resolution are examined, as well as the working distance between a lens and the target of observation.

Wing, Frank M.↗

Liquid-Crystal-Television Image Subtracters

Two image-subtraction systems from output images that show differences between input images of two objects. First: differences appear as bright regions in otherwise dark output image. Second: differences and similarities shown by colors. All parts of two images processed simultaneously by optical components only; digital electronic processing of data not required. Concept offers potential for rapid, inexpensive comparison of images in such applications as automatic inspection, medical diagnosis, and robotic vision.

Chao, Tien-Hsin↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz (10¯11) crystal.

M. J. MacDonald↗

Real time quantitative imaging for semiconductor crystal growth, control and characterization

A quantitative real time image processing system has been developed which can be software-reconfigured for semiconductor processing and characterization tasks. In thermal imager mode, 2D temperature distributions of semiconductor melt surfaces (900-1600 C) can be obtained with temperature and spatial resolutions better than 0.5 C and 0.5 mm, respectively, as demonstrated by analysis of melt surface thermal distributions. Temporal and spatial image processing techniques and multitasking computational capabilities convert such thermal imaging into a multimode sensor for crystal growth control. A second configuration of the image processing engine in conjunction with bright and dark field transmission optics is used to nonintrusively determine the microdistribution of free charge carriers and submicron sized crystalline defects in semiconductors. The IR absorption characteristics of wafers are determined with 10-micron spatial resolution and, after calibration, are converted into charge carrier density.

Wargo, Michael J.↗