Search NASA⌕ Search

SEARCH · Search NASA

Results for “Crystal spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Bragg crystal spectroscopy on the OSO 8 satellite

Results are reported for high-resolution OSO 8 Bragg-crystal spectroscopy of a variety of cosmic X-ray sources in the energy range from 2 to 10 keV. A continuous spectrum of Sco X-1 is examined, and results of a search for narrow line emission due to iron near 6.7 keV are presented for 32 galactic X-ray sources, including Sco X-1, Cyg X-3, and Cen X-3. It is noted that the strongest evidence for iron line emission has been obtained for Cyg X-3 and that evidence for an iron line feature has also been found in the spectrum of Cen X-3.

Long, K. S.↗

Crystals for astronomical X-ray spectroscopy

Crystal spectrometric properties and the factors that affect their measurement are discussed. Theoretical and experimental results on KAP are summarized and theoretical results based on the dynamical theory of X-ray diffraction are given for the acid phthalates as well as for the commonly used planes of ADP, PET and EDDT. Anomalous dispersion is found to be important for understanding the details of crystal Bragg reflection properties at long X-ray wavelengths and some important effects are pointed out. The theory of anomalous dispersion is applied to explain the anomalous reflectivity exhibited by KAP at 23.3 A.

Burek, A.↗

Growth and characterization of materials for tunable lasers in the near infrared spectral region

Laser spectroscopy, crystal growth, and radiation damage research was performed. The laser spectroscopy effort focused on understanding the effects of excited state absorption processes involving pump photons. This was performed on a variety of rare earth ions in different hosts. The crystal growth and radiation damage effort focused on LiFY4 (YLF) doped with rare earth ions. The results of this work is described.

Powell, Richard C.↗

Crystal Growth and Spectroscopy of Diglycine

Raman and infrared spectra have been obtained for alpha-diglycine (C4H8N2O3) single crystals. These dipeptide crystals are being grown as a models system for protein crystal growth studies. There have been previous Raman measurements on diglycine powder samples recorded, but there is no reference to measurements on oriented diglycine single crystals. Diglycine can grow in one of three forms, alpha, beta, or gamma.

Taylor, Taravia M.↗

Bent crystal spectrometer for solar X-ray spectroscopy

A bent crystal spectrometer employs a collimated beam of X-rays incident on the crystal over a range of Bragg angles determined by the orientation and curvature of the crystal surface. It provides continuous and simultaneous coverage of all X-ray wavelengths within its spectral range. In-flight testing for solar X-ray spectroscopy was performed using a small instrument to supplement the wavelength coverage of several scanning spectrometers used to study solar active regions in the 9-24 A range. Later testing included modifications to alleviate problems caused by ultraviolet radiation. Future usage of the device will include studies of time variable emission from solar flares or discrete galactic X-ray sources, and the first major experiment to utilize bent crystal spectrometers will be the Solar Maximum Mission satellite in 1979.

Rapley, C. G.↗

Stellar crystal X-ray spectroscopy on OSO-8

The large-area graphite crystal X-ray spectrometer on the OSO-8 satellite is described, and its response to stellar line and continuum radiation is discussed. A high resolution X-ray spectrum of Sco X-1 obtained from a preliminary analysis of quick look data shows a strong, smooth continuum with an absence of emission or absorption features over the energy range 2.2 to 8 keV. Upper limits are set on narrow line emission from highly ionized states of S, Ca, and Fe.

Kestenbaum, H. L.↗

XRD, TEM, IR, Raman and NMR Spectroscopy of In Situ Crystallization of Lithium Disilicate Glass

The structure of a Li2O-2SiO2 (LS2) glass was investigated as a function of pressure and temperature up to 6 GPa and 750 C respectively, using XRD, TEM, IR, Raman and NMR spectroscopy. Glass densified at 6 GPa has an average Si-O-Si bond angle approx.7deg lower than that found in glass processed at 4.5 GPa. At 4.5 GPa, lithium disilicate crystallizes from the glass, while at 6 GPa a new high pressure form of lithium metasilicate crystallizes. The new phase, while having lithium metasilicate crystal symmetry, contains at least 4 different Si sites. NMR results for 6 GPa sample indicate the presence of Q4 species with (Q(sup 4))Si-O-Si(Q(sup 4)) bond angles of approx.157deg. This is the first reported occurrence of Q(sup 4) species with such large bond angles in alumina free alkali silicate glass. No five- or six- coordinated Si are found.

Fuss, T.↗

Solar X-ray spectroscopy with a Bent Crystal Spectrometer /BCS/

A high-resolution Bent Crystal Spectrometer (BCS) which provides simultaneous and continuous time coverage of a range of wavelengths is described; its application to spectral studies of solar X-ray emission is discussed. Design of the BCS and its accompanying position-sensitive detector is considered. Calibrations of the crystal curvature, the angle between a crystal reference plane and the collimator axis, and the position response of the position-sensitive proportional counter in determining absolute wavelengths are also mentioned. An active solar region spectrum obtained during an airborne BCS test is compared to wavelength data derived from theory or previous experiments, and excellent agreement is found. Specifications for a BCS system to be used in the Solar Maximum Mission satellite of 1979 are given.

Rapley, C. G.↗

Cylindrical Crystal Imaging Spectrometer (CCIS) for cosmic X-ray spectroscopy

A "stigmatic" focusing, Bragg crystal spectrometer was developed and used for high spectral resolution X-ray emission line diagnostics on hot laboratory plasmas. The concept be applied at the focal plane of an orbiting X-ray telescope where it offers several advantages over conventional spectrometers, i.e., mechanical simplicity, high resolving power and sensitivity, simultaneous measurement of an extended segment of spectrum, and good imaging properties. The instrument features a simple, unambiguous, non-scanning spectrum readout that is not adversely affected by either spacecraft pointing error or source extent. The performance of the instrument is estimated in the context of the Advanced X-Ray Astrophysical Facility mission.

Schnopper, H. W.↗

Impurity Studies of Cd(0.8)Zn(0.2)Te Crystals Using Photoluminescence and Glow Discharge Mass Spectroscopy

Cd(1-x)Zn(x)Te semiconductor crystal is a highly promising material for room temperature x- and gamma-ray detector applications because of its high resistivity, long carrier lifetime, and relatively high hole and electron mobilities. This paper reports the investigation of the impurities in several Cd(1-x)Zn(x)Te (x = 0.20) crystals grown using the vertical Bridgman method under a Cd overpressure. The impurity concentrations were measured using glow discharge mass spectroscopy (GDMS). The energy states of the impurities were studied using photoluminescence (PL) spectroscopy at liquid helium temperature. The PL spectra showed a series of sharp high energy lines which are associated with free excitons and excitons bound to impurities as donors and acceptors in the crystals. The impurities also contributed to donor-acceptor pair recombination. The correlation between the GDMS and PL results will be reported.

Su, Ching-Hua↗

Vapor transport growth of organic solids in microgravity and unit gravity: some comparisons and results to date

Thin films of an organic nonlinear optical (NLO) material, N, N-dimethyl-p-(2,2-dicyanovinyl) aniline (DCVA), have been grown in space and on the ground by physical vapor transport in an effusive ampoule arrangement. The thin film growth technique developed on the ground is a direct result of information gleaned from experiments in microgravity. This paper covers the results of our experimental investigations for establishing "ideal" terrestrial conditions for deposition of a DCVA film. The active control during the deposition process was exercised by three deposition variables: the material source temperature, the background pressure external to the growth ampoule and the substrate temperature. Successful growth occurred when the difference in temperature between the source material and the copper substrate was 14 degrees C and the background nitrogen pressure was such that the transport was either diffusive or convective. A qualitative diffusion limited boundary was estimated to occur at a pressure of approximately 20 torr. We have probed the DCVA thin films with visible-near infrared reflection absorption spectroscopy, polarized Fourier transform infrared spectrometry, differential interference contrast optical microscopy, and stylus profilometry.

short duration↗

NMR spectroscopy of experimentally shocked single crystal quartz: A reexamination of the NMR shock barometer

Cygan and others report a broadening of the Si-29 nuclear magnetic resonance (NMR) peak for synthetic quartz powders with increasing shock pressure which they propose as a shock wave barometer for natural systems. These results are expanded by studying single crystal quartz shocked to 12 and 33 GPa using the 6.5 m two-stage light-gas gun at Lawrence Livermore National Laboratories. Our NMR results differ substantially from those of Cygan and others and suggest that the proposed shock wave barometer may require refinement. The difference in results between this study and that of Cygan and others is most likely caused by different starting materials (single crystal vs. powder) and different shock loading histories. NMR results from single crystal studies may be more applicable to natural systems.

Fiske, P. S.↗