Search NASA⌕ Search

SEARCH · Search NASA

Results for “Current regulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Current-Regulated Arc Modulator Optimization

n this study, the performance of a current-regulated arc modulator was investigated with a focus on its role in initiating and sustaining plasma discharge within the Magnetron Body of the LINAC system. The analysis centered on how switching components, circuit topology, and feedback loop architecture influence critical factors such as energy efficiency, discharge stability, and long-term plasma containment. Particular attention was given to variations in pulse termination behavior, as observed through oscilloscope traces, which revealed inconsistencies affecting the duty factor and cathode temperature. These fluctuations have downstream effects on the cesium-coated cathode surface, thereby impacting H⁻ ion production and beam reliability. Simulation-based testing in LTspice was used to evaluate noise suppression techniques and arc current regulation schemes, revealing how optimized snubber networks, improved pulse shaping, and feedback stability can mitigate modulator-induced noise. The results ide

Campos, Nathan↗

Development and Testing of a new Current-Regulated Arc Modulator for the LINAC

In this study, the performance of a current-regulated arc modulator was investigated with a focus on its role in initiating and sustaining plasma discharge within the Magnetron Body of the LINAC system. The analysis centered on how switching components, circuit topology, and feedback loop architecture influence critical factors such as energy efficiency, discharge stability, and long-term plasma containment. Particular attention was given to variations in pulse termination behavior, as observed through oscilloscope traces, which revealed inconsistencies affecting the duty factor and cathode temperature. These fluctuations have downstream effects on the cesium-coated cathode surface, thereby impacting H⁻ ion production and beam reliability. Simulation-based testing in LTspice was used to evaluate noise suppression techniques and arc current regulation schemes, revealing how optimized snubber networks, improved pulse shaping, and feedback stability can mitigate modulator-induced noise. The results identified hardware level parameters that significantly enhance discharge repeatability and improve overall plasma performance under operational conditions.

Campos, Nathan [Unlisted, US; Fermilab]↗

Precision current regulator for NMR electromagnets

When using electromagnets or non-persistent superconducting magnets, the field stability can be directly proportional to the current stability. We present in this report a simple design for a current regulator based upon a high-precision, dc-dc fluxgate transformer. The output current and NMR frequency are stabilized by about a factor of 50, over times of order one hour. The method can be applied to essentially any current supply.

59 BASIC BIOLOGICAL SCIENCES↗

Vanadium oxide coatings to self-regulate current sharing in high-temperature superconducting cables and magnets

High-temperature superconductors such as REBa 2 Cu 3 O 7-δ (REBCO, RE = rare earth) enable high-current cables and high-field magnets. By removing the turn-to-turn insulation in a magnet application, recent experiments demonstrated that REBCO magnets can self-protect against catastrophic damage during a superconducting-to-normal transition (quench), i.e., when the stored magnetic energy rapidly converts to heat. The current can bypass the hot spot during a quench, thereby reducing the localized heat dissipation. The removal of the insulation between turns, however, leads to excessive eddy currents during current ramping, thereby forcing a much-prolonged magnet charging time. To address this issue, we investigate vanadium oxide (VO x ) coatings as a temperature-dependent self-switching medium that automatically manages current sharing. VO x coatings (with 1.70 ≤ × ≤ to 2.07) were deposited by reactive cathodic arc deposition, initially on insulating glass to determine the electrical properties, and later on commercial REBCO tapes. The coatings are x-ray amorphous but with a short-range crystalline ordering according to Raman spectrometry. The resistivity of VO x decreased by at least three orders of magnitude when the temperature increased from 80 to 300 K. The coating process is compatible with commercial REBCO tapes as evidenced by the negligible change in the critical current caused by the coating process. Here, the results from current sharing experiments and circuit analysis suggest that the VO x coating can effectively self-regulate current sharing in REBCO magnets, suppress excessive eddy currents, and enable self-protection during quenches.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resource Adequacy for State Utility Regulators: Current Practices and Emerging Reforms

This report was developed by staff in the National Association of Regulatory Utility Commissioners (NARUC) Center for Partnerships and Innovation (CPI). Additional support was provided from commissioners, commission staff, and other technical experts to provide foundational information for state utility regulators on the evolving nature of resource adequacy for the electric system. With the changing nature of the system, state commissioners will continue to play a vital role in their respective jurisdictions. Their roles in overseeing resource decisions are growing in complexity, with consideration for customer costs, state and federal environmental requirements, extreme weather events, fuel supply limitations, generation retirements, shifting requirements for system operators, and growing levels of intermittent and energy-limited resources (e.g., wind, solar, and battery storage). Reliability concerns continue to be an urgent and immediate priority for utility regulators in most parts of the United States. The information in this report is designed to support state commissioners and their respective staff members as they navigate an evolving resource adequacy landscape to maintain reliability amidst a rapidly changing system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Per-Phase Control for CHB Converters with Negative-Sequence Current and DC Voltage Balancing Control

This paper presents a per-phase controller for a grid-connected Cascaded H-Bridge (CHB) converter featuring negative sequence current regulation and DC bus voltage balancing capabilities. Unlike conventional three-phase controllers, each phase of the CHB can be separately and controlled to regulate the DC voltage and reactive power flow. per-phase negative sequence current control strategy is incorporated into the proposed controller to ensure compliance with IEEE Standard 2800-2022, which requires the absorption of negative-sequence reactive current during grid voltage disturbances. Furthermore, a feed-forward control-based DC bus voltage balancing method is employed, which eliminates the need for the integrator commonly used in traditional approaches. The performance of the proposed controller is validated under various unbalanced grid scenarios and DC bus voltage imbalances through electromagnetic transient (EMT) simulation using a three-phase, three-level grid-connected CHB–Dual Active Bridge (DAB) converter testbed developed on MATLAB/Simulink. Additionally, the performance of the negative-sequence current regulation is investigated through simulation under different unbalanced grid voltage scenarios.

negative sequence current↗

Current Density Regulated Atomic to Nanoscale Process on Li Deposition and Solid Electrolyte Interphase Revealed by Cryogenic Transmission Electron Microscopy

Current density has been perceived to play a critical rule for controlling Li deposition morphology and solid electrolyte interphase (SEI). However, the atomic level mechanism of current density on Li deposition and the SEI remains unclear. In this work, based on cryogenic transmission electron microscopy imaging combined with energy dispersive X-ray spectroscopy and electron energy loss spectroscopy electronic structure analyses, we reveal the atomic level correlation of Li deposition morphology and SEI with current density. We discover that increasing current density leads to increased overpotential for Li nucleation and growth, leading to the transition from growth-limited to nucleation-limited mode for Li dendrite. Independence of current density, the electrochemically deposited Li metal (EDLi) exhibits crystalline whisker-like morphology. The SEI formed at low current density (0.1 mA cm -2 ) is monolithic amorphous; while, a current density of above 2 mA cm -2 leads to a mosaic structured SEI, featuring an amorphous matrix with Li 2 O and LiF dispersoids, and the thickness of the SEI increases with the increase of current density. Uniquely, the Li 2 O particles is spatially located at the top surface of the SEI, while LiF is spatially adjacent to the Li-SEI interface. These results highlight the possible tuning of crucial structural and chemical features of EDLi and SEI through altering deposit conditions and consequently direct correlation with electrochemical performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗

Comparison of Side-on Peak Overpressure Predictions and Measurements for Type IV Composite Overwrapped Pressure Vessel Catastrophic Failure

This development of empirical data to support realistic and science-based input to safety regulations and transportation standards is a critical need for the hazardous material (HM) transportation industry. Current regulations and standards are based on the TNT equivalency model. However, real world experience indicates that use of the TNT equivalency model to predict composite overwrapped pressure vessel (COPV) potential energy release is unrealistically conservative. The purpose of this report is to characterize and quantify rupture events involving damaged COPV’s of the type used in HM transportation regulated by the Department of Transportation (DOT). This was accomplished using a series of five tests; 2 COPV tests for compressed natural gas (CNG), 2 COPV tests for hydrogen, and 1 COPV test for nitrogen. Measured overpressures from these tests were compared to predicted overpressures from a TNT equivalence model and blast curves. Comparison between the measurements and predictions shows that the predictions are generally conservative, and that the extent of conservatism is dominated by predictions of the chemical contribution to overpressure from fuel within the COPVs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Federal Oversight of Hydrogen Systems

The application of hydrogen as an energy carrier has been expanding into industrial and transportation sectors enabling sustainable energy resources and providing a zero-emission energy infrastructure. The hydrogen supply infrastructure includes processes from production and storage, to transportation and distribution, to end use. Each portion of the hydrogen supply infrastructure is regulated by international, federal, state, and local entities. Regulations are enforced by entities which provide guidance and updates as necessary. While energy sources such as natural gas are currently regulated via the Code of Federal Regulations and United States Code, there might be some ambiguity as to which regulations are applicable to hydrogen and where regulatory gaps may exist. This report contains an overview of the regulations that apply to hydrogen, and those that may indirectly cover hydrogen as an energy carrier participating in a sustainable zero emission global energy system. As part of this effort, the infrastructure of hydrogen systems and regulation enforcement entities are defined, and a visual map and reference table are developed. This regulatory map and table can be used to identify the boundaries of federal oversight for each component of the hydrogen supply value chain which includes production, storage, distribution, and use.

08 HYDROGEN↗

Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids

Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Electrodeposition in 3D Porous Architectures for Solid-State Li-Metal Batteries

Li-metal storage in three-dimensional (3D) electrodes is considered a potential dendrite-mitigation strategy. The large surface area and high porosity of these electrodes result in reduced local Li-plating current densities. The porous topology provides a scaffold for Li-deposition and stripping, maintaining both mechanical integrity and Li accessibility. The goal of this study is to understand how characteristics, such as geometry and material properties, affect the current distribution and deposition pattern. To this end, we developed a computational method to track material growth driven by electrodeposition within a complex geometry. This method ensures that the finite-element discretization remains conforming to the moving boundary while preserving an adequate mesh quality, and thus maintains solution accuracy. Using this new computational tool, we analyze the conditions under which porous anode architectures effectively expand the surface area of the charge-transfer interface, and self-regulate current density and dendrite growth.

3D electrode architectures↗

Proposed Risk-Informed Regulatory Framework for Approval of Microreactor Transportation Packages

Microreactors are very small nuclear reactors with a power output of about 20 megawatts electric or less that are designed to be factory-built, modular in nature, and highly portable. These compact reactors will be small enough to be transported by truck or even air and could help solve energy challenges in a number of areas, ranging from remote commercial or residential locations to military bases. Pacific Northwest National Laboratory is tasked to develop and evaluate transportation licensing options for microreactors. The work is funded by the National Reactor Innovation Center a National Department of Energy program led by Idaho National Laboratory for the Office of Nuclear Energy Research and Development which support demonstration of microreactor technology. Key transportation steps include the (1) initial movement of high-assay low enriched uranium fresh fuel, (2) transportation of an intact, but never-operated microreactor, and (3) transportation of an intact, previously-operated microreactor. The deliverables on the project consists of a documentation of applicable regulations and regulatory authority for transportation. The objective of this report is to propose a risk-informed regulatory framework for the licensing of the transportation of microreactors, including the transportation of irradiated nuclear fuel that is assumed to be an integral component of the microreactor transportation package. The framework lays out a viable regulatory pathway, including decision points for regulatory options and the supporting technical evaluations for those options in phases from near to long term. This report includes discussion of the (1) general microreactor design concepts including representative microreactor source terms, (2) options for regulatory approval of microreactor transportation based on current regulation and historical precedence, (3) regulatory basis for including risk information in microreactor transportation licensing activities, and (4) description of a risk-informed regulatory framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Proposed Risk-Informed Regulatory Framework for Approval of Microreactor Transportation Packages

Microreactors are very small nuclear reactors with a power output of about 20 megawatts electric or less that are designed to be factory-built, modular in nature, and highly portable. These compact reactors will be small enough to be transported by truck or even air and could help solve energy challenges in a number of areas, ranging from remote commercial or residential locations to military bases. Pacific Northwest National Laboratory is tasked to develop and evaluate transportation licensing options for microreactors. The work is funded by the National Reactor Innovation Center a National Department of Energy program led by Idaho National Laboratory for the Office of Nuclear Energy Research and Development which support demonstration of microreactor technology. Key transportation steps include the (1) initial movement of high-assay low enriched uranium fresh fuel, (2) transportation of an intact, but never-operated microreactor, and (3) transportation of an intact, previously-operated microreactor. The deliverables on the project consists of a documentation of applicable regulations and regulatory authority for transportation. The objective of this report is to propose a risk-informed regulatory framework for the licensing of the transportation of microreactors, including the transportation of irradiated nuclear fuel that is assumed to be an integral component of the microreactor transportation package. The framework lays out a viable regulatory pathway, including decision points for regulatory options and the supporting technical evaluations for those options in phases from near to long term. This report includes discussion of the (1) general microreactor design concepts including representative microreactor source terms, (2) options for regulatory approval of microreactor transportation based on current regulation and historical precedence, (3) regulatory basis for including risk information in microreactor transportation licensing activities, and (4) description of a risk-informed regulatory framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling distributed energy resource aggregations in security constrained unit commitment and economic dispatch

The Federal Energy Regulatory Commission (FERC) recently issued Order 2222, which requires all wholesale electricity markets in the US to allow distributed energy resources (DERs) to participate in the market as aggregated resources. These DER aggregations may be composed of many individual resources that are offered and dispatched by the market as a single entity. We present here a model of a distributed energy resource aggregator (DERA) that is scheduled by a market operator’s security constrained unit commitment (SCUC) and security constrained economic dispatch (SCED). The DERA model includes constraints for battery energy storage systems (BESSs), demand response resources (DRRs), and a simple distributed energy resource (DER). This paper describes a model for each resource type and presents two methods for the DERA to generate market offer curves: a profit-maximizing optimization to compute cost curves and a direct cost algorithm to determine dispatch costs for each resource and combine into cost curves. Once all participating DERAs are scheduled in SCUC/SCED, the model is then modified to dispatch individual DERs to maximize profit or minimize schedule deviation of the DERAs. A simulation of a representative day illustrates the DERA offers, the scheduled generation, and the DERA dispatch. Findings show the potential for unavoidable schedule deviations due to internal DER constraints and due to economic incentives to deviate from the SCUC/SCED schedules. This highlights the importance of DERA offer construction on market efficiency and system reliability. Novel aspects of our approach include: (1) We consider the asymmetry of price incentives impacting DERAs from the wholesale market compared to those impacting consumers from the retail market, as imposed by current regulations and laws. (2) We model aggregate consumer response through statistically parameterizable utility functions rather than a potentially impractical approach of modeling each individual consumer. (3) We show how to use the DERA operational dispatch model to create offers into the wholesale electricity market. (4) We show how DERAs may fail to meet their scheduled dispatch because the market offer format may not permit them to fully express their operational features such as intertemporal costs and constraints to the market.

aggregations↗

Comparison of atmospheric radionuclide dispersion models for a risk-informed consequence-driven advanced reactor licensing framework

Current nuclear facility emergency planning zones (EPZs) are based on outdated distance-based criteria, predating comprehensive dose and risk-informed frameworks. Recent advancements in simulation tools have permitted the development of site-specific, dose, and risk-based consequence-driven assessment frameworks. This study investigated the computation of advanced reactor (AR) EPZs using two atmospheric dispersion models: a straight-line Gaussian plume model (GPM) and a semi-Lagrangian Particle in Cell (PIC). Two case studies were conducted: (1) benchmarking the NRC SOARCA study for the Peach Bottom Nuclear Generating Station and (2) analyzing an advanced INL Heat Pipe Design A microreactor's end-of-cycle inventory. The dose criteria for both cases were 10 mSv at mean weather conditions and 50 mSv at 95th percentile weather conditions at 96 h post-release. Results demonstrated that GPM and PIC estimated similar mean peak dose levels for large boiling water reactors in the farfield case, placing EPZ limits beyond current regulations. For ARs with source terms remaining in the nearfield, PIC modeling without specific nearfield considerations could result in excessively high doses and inaccurate EPZ designations. PIC dispersion demonstrated an order of magnitude higher estimate of nearfield inhalation dose contribution when compared to GPM results. Furthermore, both models significantly reduced EPZ sizing within the nearfield. Thus, reductions in the AR source term may eliminate the need for a separate EPZ.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Disentangling climate and policy uncertainties for the Colorado River post-2026 operations

Abstract Lakes Mead and Powell in the Colorado River Basin underpin water and hydropower supply for the western United States. While the policies currently regulating the basin will expire by 2026, planning remains challenging due to intertwined climate variability and policy uncertainties. Based on streamflow projections from 10 dynamically downscaled CMIP6 global climate models and unique methods that add and remove internal variability, we evaluate future conditions at Powell and Mead under existing and alternative policies. Due to projected streamflow declines, under existing policy, both reservoirs will face substantial risks (>80% likelihood) of reaching dead pool before 2060. Adopting recently proposed alternative policies reduces but doesn’t eliminate such risks. All policies also exhibit tipping points where reservoir levels can change rapidly with a slight change in streamflow. A sustainable policy may require larger reductions to further reduce the reservoirs’ dead pool risks and provide better buffers from sudden changes.

Science & Technology - Other Topics↗