Search NASA⌕ Search

SEARCH · Search NASA

Results for “Current stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Earth Observing-1 Advanced Land Imager Flight Performance Assessment: Noise and Dark Current Stability During the First Year on Orbit

The noise and dark current stability of the Advanced Land Imager during the first year on orbit (November 21, 2000 - November 21, 2001) are presented. Data have been separated into short-term and long-term periods. The analysis of short-term data indicate some SWIR detectors may drift up to ten digital numbers between the pre and post dark observations of a given data collection event. Analysis of long-term data suggest the SWIR dark current has deviated by less than ten digital numbers and some SCA SWIR dark Current have increased by up to 200 digital numbers during the first year on orbit.

Mendenhall, J. A.↗

Earth Observing-1 Advanced Imager Flight Performance Assessment: Investigating Dark Current Stability Over One-Half Orbit Period during the First 60 Days

The stability of the EO-1 Advanced Land Imager dark current levels over the period of one-half orbit is investigated. A series of two-second dark current collections, over the course of 40 minutes, was performed during the first sixty days the instrument was in orbit. Analysis of this data indicates only two dark current reference periods, obtained entering and exiting eclipse, are required to remove ALI dark current offsets for 99.9% of the focal plane to within 1.5 digital numbers for any observation on the solar illuminated portion of the orbit.

Mendenhall, J. A.↗

Critical Current Stability of 2G REBCO Tape for Space-Flight HTS Leads

High reliability is an essential requirement for all spaceflight hardware. XRISM, a follow-on mission to the Hitomi x-ray observatory, also uses 2G REBCO tapes as current leads for the superconducting magnets that are a key component of the Adiabatic Demagnetization Refrigerator (ADR) that cools the detector array. While the Hitomi Soft X-ray Spectrometer (SXS) worked flawlessly in orbit, during its development there were indications that the critical current of its specialized REBCO tapes could degrade over time when exposed to normal-humidity air. To demonstrate that the updates to the XRISM HTS lead assemblies had mitigated this risk, a series of tests were carried out to measure the stability of Ic of dozens of samples over a period greater than the flight assemblies were exposed to air during integration and test. The test rig allowed not only the measurement of the sample Ic, but also the localization of the voltage rise as the current approached Ic. We will discuss the trends in the critical current of the samples, as well as localization of lower Ic regions.

Edgar R. Canavan↗

Measurements of Breakdown Field and Forward Current Stability in 3C-SiC P-N Junction Diodes Grown on Step-Free 4H-SiC

This paper reports on initial fabrication and electrical characterization of 3C-SiC p-n junction diodes grown on step-free 4H-SiC mesas. Diodes with n-blocking-layer doping ranging from approx. 2 x 10(exp 16)/cu cm to approx.. 5 x 10(exp 17)/cu cm were fabricated and tested. No optimization of junction edge termination or ohmic contacts was employed. Room temperature reverse characteristics of the best devices show excellent low-leakage behavior, below previous 3C-SiC devices produced by other growth techniques, until the onset of a sharp breakdown knee. The resulting estimated breakdown field of 3C-SiC is at least twice the breakdown field of silicon, but is only around half the breakdown field of <0001> 4H-SiC for the doping range studied. Initial high current stressing of 3C diodes at 100 A/sq cm for more than 20 hours resulted in less than 50 mV change in approx. 3 V forward voltage. 3C-SiC, pn junction, p+n diode, rectifier, reverse breakdown, breakdown field,heteroepitaxy, epitaxial growth, electroluminescence, mesa, bipolar diode

Neudeck, Philip G.↗

Electric Machine with Boosted Inductance to Stabilize Current Control

High-powered motors typically have very low resistance and inductance (R and L) in their windings. This makes the pulse-width modulated (PWM) control of the current very difficult, especially when the bus voltage (V) is high. These R and L values are dictated by the motor size, torque (Kt), and back-emf (Kb) constants. These constants are in turn set by the voltage and the actuation torque-speed requirements. This problem is often addressed by placing inductive chokes within the controller. This approach is undesirable in that space is taken and heat is added to the controller. By keeping the same motor frame, reducing the wire size, and placing a correspondingly larger number of turns in each slot, the resistance, inductance, torque constant, and back-emf constant are all increased. The increased inductance aids the current control but ruins the Kt and Kb selections. If, however, a fraction of the turns is moved from their "correct slot" to an "incorrect slot," the increased R and L values are retained, but the Kt and Kb values are restored to the desired values. This approach assumes that increased resistance is acceptable to a degree. In effect, the heat allocated to the added inductance has been moved from the controller to the motor body, which in some cases is preferred.

Abel, Steve↗

Critical current and stability tests of Nb 3 Sn for LBNL CCT magnet project

The Nb 3 Sn wires received from LBNL include the original round wires as well as the extracted wires from Rutherford cables. Total of 12 samples were prepared and heat treated. Five of them were tested for electric field versus current (E-I), among them 4 samples were further tested for electric field versus magnetic field (E-H). E-I traces were measured in magnetic field between 5 T and 8 T at 4.2 K. The critical currents of these sample are between 924 A and 993 A at 5 T. E-H measurements were performed at currents between 900 and 1500 A at 4.2 K. The stability currents, which is defined as the maximum current without quench during the E-H test, are determined to be between 1100 A and 1400 A. A separate Excel file presenting all the critical current and E-H curves is attached.

36 MATERIALS SCIENCE↗

Particle scattering and current sheet stability in the geomagnetic tail during the substorm growth phase

The particle scattering and current sheet stability features in the geomagnetic tail during the phase of substorm growth were investigated using Tsyganenko's (1989) magnetic field model. In a study of four substorm events which were observed both in the high-altitude nightside tail and in the auroral ionosphere, the model magnetic field was adjusted to each case so as to represent the global field development during the growth phase of the substorms. The model results suggest that the auroral brightenings are connected with processes taking place in the near-earth region inside about 15 earth radii. The results also suggest that there is a connection between the chaotization of the electrons and the auroral brightenings at substorm onset.

Pulkkinen, T. I.↗

How an electrical current can stabilize a molecular nanojunction

Molecular junctions at the brink of their stability typically undergo structural changes that affect their conductance properties. This effect provides a feedback mechanism that can stabilize molecular junctions against current-induced bond-rupture.

Chemistry↗

Equatorial ground ice on Mars: Steady-state stability

Current Martian equatorial surface temperatures are too warm for water ice to exist at the surface for any appreciable length of time before subliming into the atmosphere. Subsurface temperatures are generally warmer still and, despite the presence of a diffusive barrier of porous regolith material, it has been shown by Smoluchowski, Clifford and Hillel, and Fanale et al. that buried ground ice will also sublime and be lost to the atmosphere in a relatively short time. We investigate the behavior of this subliming subsurface ice and show that it is possible for ice to maintain at a steady-state depth, where sublimation and diffusive loss to the atmosphere is balanced by resupply from beneath by diffusion and recondensation of either a deeper buried ice deposits or ground water. We examine the behavior of equatorial ground ice with a numercial time-marching molecular diffusion model. In our model we allow for diffusion of water vapor through a porous regolith, variations in diffusivity and porosity with ice content, and recondensation of sublimed water vapor. A regolith containing considerable amounts of ice can still be very porous, allowing water vapor to diffuse up from deeper within the ice layer where temperatures are warmer due to the geothermal gradient. This vapor can then recondense nearer to the surface where ice had previously sublimed and been lost to the atmosphere. As a result we find that ice deposits migrate to find a steady-state depth, which represents a balance between diffusive loss to the atmosphere through the overlying porous regolith and diffusive resupply through a porous icy regolith below. This depth depends primarily on the long-term mean surface temperature and the nature of the geothermal gradient, and is independent of the ice-free porosity and the regolith diffusivity. Only the rate of loss of ground ice depends on diffusive properties.

Mellon, Michael T.↗

Wehnelt photoemission in an ultrafast electron microscope: Stability and usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a custom 100 μm diameter LaB 6 source with a graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a custom 200 μm diameter polycrystalline Ta source. For each cathode type and configuration, including the Ni Wehnelt aperture, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Furthermore, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of the optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB 6 thermionic emission, as well as to on-axis photoemission [the heretofore conventional approach to ultrafast electron microscopy (UEM) in thermionic-based instruments]. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be ±1% (one standard deviation from the mean) for 70 min (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition were also found to be within ±1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gas diffusion electrodes, reactor designs and key metrics of low-temperature CO 2 electrolysers

We report that CO 2 emissions can be recycled via low-temperature CO 2 electrolysis to generate products such as carbon monoxide, ethanol, ethylene, acetic acid, formic acid and propanol. In recent years, progress has been made towards an industrially relevant performance by leveraging the development of gas diffusion electrodes (GDEs), which enhance the mass transport of reactant gases (for example, CO 2 ) to the active electrocatalyst. Innovations in GDE design have thus set new benchmarks for CO 2 conversion activity. In this Review, we discuss GDE-based CO 2 electrolysers, in terms of reactor designs, GDE composition and failure modes, to identify the key advances and remaining shortfalls of the technology. This is combined with an overview of the partial current densities, efficiencies and stabilities currently achieved and an outlook on how phenomena such as carbonate formation could influence the future direction of the field. Our aim is to capture insights that can accelerate the development of industrially relevant CO 2 electrolysers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High resolution color band pyrometer ratioing

The sensing head of a two-color band ratioing pyrometer of a known type using a fiber optic cable to couple radiation to dual detector photodiodes is improved to have high spatial resolution by focusing the radiation received through an objective lens (i.e., by focusing the image of a target area) onto an opaque sheet spaced in front of the input end of the fiber optic cable. A two-mil hole in that sheet then passes radiation to the input end of the cable. The detector has two channels, one for each color band, with an electronic-chopper stabilized current amplifier as the input stage followed by an electronic-chopper stabilized voltage amplifier.

Bickler, Donald B.↗

Electrospray Thruster Performance with Microfabricated Emitter Arrays and Indium Propellant

The feasibility of a microfabricated indium-fueled electrospray thruster with excellent performance was demonstrated. High efficiency electrospray thrusters with microfabricated components are under development for very compact, distributable propulsion systems that can be employed on both very small and large spacecraft with 10X improvement over SOA in mass, volume and specific impulse The critical components of this technology are the microfabricated emitter arrays and the capillary force driven indium feed system. Grey scale electron-beam lithography patterning and reactive ion dry etching provided the required micron-scale etch precision and uniformity across an array of 400 emitters in 1 cm2. Initial tests of single microfabricated silicon emitters demonstrated better performance than industry standard single emitters and the performance required to achieve 200 micronewtons when scaled up to a thruster with 400 emitters in 1 cm2. Arrays of emitters tested in a preliminary prototype Microfluidic Electrospray Propulsion (MEP) thruster assembly demonstrated stable performance at estimated thrust levels of 5, 50, and 120 µN at extraction voltages less than 4 kV. Current stability was within 0.15 % at 120 µN with only 1.5% of the emitter current collected by the extractor electrode. Post-test inspections revealed that more than 99% of the 400 emitters were electrospraying during the test. Specific impulse was estimated to be >3100 s from measurements of total charge and consumed indium mass at an emitter voltage of 1470 V. The results of this investigation suggest that microfabricated indium electrospray thruster technology is both feasible and capable of excellent performance as a highly compact microthruster.

Marrese-Reading, Colleen M.↗