Search NASASearch

SEARCH · Search NASA

Results for “Curved scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Scintillation modeling.

Results of a quantitative attempt to model the scintillation-producing ionospheric irregularities. An empirical model of rms electron-density fluctuation and transverse scale size was employed for this purpose. On the basis of an analysis of diurnal-variation curves for scintillation, it is concluded that in most instances the model will produce better than order-of-magnitude estimates of the strength of scintillation to be expected under average ionospheric conditions. However, a number of significant limitations to the model are noted.

Fremouw, E. J.

Improved Lixiscope

Improved lixiscope utilizes fast-decay scintillators and multiple or curved microchannels to achieve high energy and spatial resolution as well as single-photon counting. New unit, with higher energy resolution, is intended for X-ray astronomy, although it could be applied terrestrially wherever a sensitive portable radiation spectrometer is required for 20-to-200-keV range.

Yin, L. I.

Turbulence in deep radio occultations

The effects of turbulence in the focal region of spherical or weakly oblate refracting bodies on the evolute flashes associated with the crossing of the evolute of the planetary limb by an occulted spacecraft are investigated. The approximate theory of focal evolutes in oblate refractivity fields developed by Eshleman et al. (1979) is combined with a generalized weak scattering scintillation theory that includes the effect of focusing around a curved limb to obtain expressions for the scintillation index and power spectrum. Results are then applied to the radio observations of the crossing of the focal evolute of Jupiter by Voyager 1, in which no flash was detected, and to the effects of the solar coronal plasma on the gravitational lens of the sun.

Haugstad, B. S.

Scintillations during occultations by planets. 1. An approximate theory

Scintillations observed during occultations of both stars and spacecraft by planetary atmospheres are discussed theoretically. The effects of severe flattening of the Fresnel zone or source image by defocusing on occultations are presented, along with temporal power spectra. Other topics discussed include atmospheric turbulence, saturation of scintillation, effects of saturation on occultation curves, and some methods for a more accurate determination of atmospheric structure.

Young, A. T.

Atmospheric gamma ray angle and energy distributions from sea level to 3.5 g/sq cm and 2 to 25 MeV

Differential fluxes of gamma rays were calculated for energies of 2-25 MeV, zenith angles of 0-50 deg and 180-130 deg, and atmospheric depths from nominal sea level, 1000 g/sq cm, to float altitude, 3.5 g/sq cm residual atmosphere. Above 100 g/sq cm growth curves were constructed to estimate the contribution of the extraterrestrial gamma ray flux to the total downward-moving flux, while the upward-moving gamma rays were taken to be strictly of atmospheric origin. Below 100 g/sq cm, all gamma rays originate in the atmosphere. The downward atmospheric flux increases by almost two orders of magnitude between float altitude and the Pfotzer maximum, while the extraterrestrial flux is attenuated exponentially. Gamma rays produced by neutron interactions with the carbon in the scintillator liquid are eliminated by constructing growth curves for downward-moving gamma rays at high altitudes and are negligible compared with downward-moving gamma rays at lower altitudes and upward-moving gamma rays at all altitudes.

Ryan, J. M.

Prolonged triboluminescence in clays and other minerals

Samples of various clays and minerals were ground or fractured and monitored with a liquid scintillation spectrometer in order to obtain triboluminescent decay curves. Kaolinite samples displayed several million counts/min after grinding, with a surface area emission estimated at tens of billions of photons/sq cm of surface. The photon production rates varied with the origin of the sample, and kaolinite continually yielded higher production rates than bentonite. The addition of water to the samples slightly increased the count rate of emitted light, while the addition of the fluorescent molecule substance tryptofan significantly enhanced the count rate. Freezing smears of kaolinite and montmorillonite in liquid nitrogen and in a salt ice mixture also induced triboluminescence in the montmorillonite. A possible connection between powdery triboluminescent materials formed in mining industries and respiratory disorders among miners is suggested.

Lahav, N.

The experimental cascade curves of EAS at E sub 0 10(17) eV obtained by the method of detection of Cherenkov pulse shape

The individual cascade curves of EAS with E sub 0 10 to the 17th power eV/I to 3/ were studied by detection of EAS Cherenkov light pulses. The scintillators located at the center of the Yakutsk EAS array within a 500-m radius circle were used to select the showers and to determine the main EAS parameters. The individual cascade curves N(t) were obtained using the EAS Cherenkov light pulses satisfying the following requirements: (1) the signal-to-noise ratio fm/delta sub n 15, (2) the EAS axis-detector distance tau sub 350 m, (3) the zenith angle theta 30 deg, (4) the probability for EAS to be detected by scintillators W 0.8. Condition (1) arises from the desire to reduce the amplitude distortion of Cherenkov pulses due to noise and determines the range of EAS sizes, N(t). The resolution times of the Cherenkov pulse shape detectors are tau sub 0 approx. 23 ns which results in distortion of a pulse during the process of the detection. The distortion of pulses due to the finiteness of tau sub 0 value was estimated. It is shown that the rise time of pulse becomes greater as tau sub 0.5/tau sub 0 ratio decreases.

Fomin, Y. A.

On method of muon spectrum measurements by the scintillation detectors of a large thickness T4t sub o

Various methods for the study of muon spectrum are presented. The direct ones include the muon energy measurements by magnetic spectrometers. The indirect ones deal with the reconstruction of the muon spectrum from the spectrum of secondary particles obtained by burst or calorimeter technique. The burst technique is based on the measurement of the number of cascade particles, mainly in the cascade maximum, by the detectors of small thickness T sub 0. The calorimeter method consist in determination of the cascade energy with help of the cascade curve shape. The multilayer detectors are used for this purpose. They are usually comprised of proportional counters, X-ray emulsion chambers or scintillation counters with the target material placed between them. The scintillation detectors of a large thickness measures the total cascade energy directly and the detector works as a true calorimeter. When the total energy is detected, the cascade spectrum differs from the muon one.

Ryazhskaya, O. G.

Energy migration and scintillation kinetics in compositionally complex (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce single crystal scintillator

It is well-established that compositional tuning through binary admixture can improve scintillation performance in several materials systems, including Ce-activated garnets. Although recent work on ternary or quaternary cation admixture shows promise, the impact of this increased compositional complexity on thermal stability and carrier-defect dynamics has not been addressed. Here, we investigate a compositionally complex garnet, (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce (GYTLAG), grown by the Czochralski method using temperature-dependent photoluminescence (PL), PL decay, and thermoluminescence (TL). PL and PL decay measurements support a thermally activated Tb 3+ -Ce 3+ energy transfer, where Tb 3+ emission dominates below 60 K, but Ce 3+ emission increases from 20-300 K. Thermal quenching of Ce 3+ emission occurs around T 50 = 508 K, with an activation energy of 0.6 eV. TL and wavelength-resolved TL spectra from 20–500 K show that GYTLAG contains similar trap groups to LuAG but with a broader distribution of glow peaks below room temperature, possibly caused by quaternary cation mixing. A combination of dose dependence, partial cleaning and initial rise, and glow curve fitting to a first order continuous Gaussian distribution model are used to understand the contribution of electronic point defects to scintillation decay and afterglow at room temperature. Furthermore, these results inform how increased compositional complexity influences recombination dynamics in garnet scintillators.

Compositionally complex

A new method for using Cf-252 in SEU testing

A system using Cf-252 and associated nuclear instrumentation has determined the single-event upset (SEU) cross section versus linear energy transfer (LET) curve for several 2K x 8 static random access memories (SRAMs). The Cf-252 fission fragments pass through a thin-film organic scintillator detector (TFD) on the way to the device under test (DUT). The TFD provides energy information for each transiting fragment. Data analysis provides the energy of the individual ion responsible for each SEU; thus, separate upset cross sections can be developed for different energy and mass regions of the californium spectrum. This californium-based device is quite small and fits onto a bench top. It provides a convenient and inexpensive supplement or alternative to accelerator and high-altitude/space SEU testing.

Costantine, A.

Meter-wavelength VLBI. III - Pulsars

Observations of pulsars, especially the Crab Nebula pulsar, made in very long baseline interferometry (VLBI) experiments are discussed. Based on a crude 144 MHz visibility curve which is consistent with a Gaussian brightness distribution, the measured visibilities at 196, 111, and 74 MHz were interpreted to yield apparent angular diameters (at half-power) of about 0.03 sec, 0.07 sec, and 0.18 sec, respectively. These sizes scale approximately as wavelength-squared, and the 74 MHz size agrees with recent observations using interplanetary scintillation techniques. The total flux densities lie on the extrapolation from higher frequencies of the pulsing flux densities. Variations in the total flux density up to 25 per cent were observed. A lack of fine structure other than the pulsar in the nebula is indicated by the simple visibility curves. The pulse shapes are similar to single-dish measurements at 196 MHz but reveal a steady, nonpulsing component at 111 MHz. The ratio of pulsing to total power was approximately equal to one-half but varied with time. It was found that four strong, low-dispersion pulsars were only slightly resolved.

Vandenberg, N. R.

Calibration of a stack of NaI scintillators at the Berkeley Bevalac

An analysis of the carbon and argon data reveals that essentially all of the charge-changing fragmentation reactions within the stack can be identified and removed by imposing the simple criteria relating the observed energy deposition profiles to the expected Bragg curve depositions. It is noted that these criteria are even capable of identifying approximately one-third of the expected neutron-stripping interactions, which in these cases have anomalous deposition profiles. The contribution of mass error from uncertainty in delta E has an upper limit of 0.25 percent for Mn; this produces an associated mass error for the experiment of about 0.14 amu. It is believed that this uncertainty will change little with changing gamma. Residual errors in the mapping produce even smaller mass errors for lighter isotopes, whereas photoelectron fluctuations and delta-ray effects are approximately the same independent of the charge and energy deposition.

Schindler, S. M.

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Use of relativistic rise in ionization chambers for measurement of high energy heavy nuclei

A balloon-borne instrument has been constructed to measure the energy spectra of cosmic-ray heavy nuclei in the range of about 0.3 to about 100 GeV/amu. It makes use of the relativistic rise portion of the Bethe-Bloch curve in ionization chambers for energy determination in the 10- to 100-GeV/amu interval. The instrument consists of six layers of dual-gap ionization chambers for energy determination above 10 GeV/amu. Charge is determined with a NE114 scintillator and a Pilot 425 plastic Cerenkov counter. A CO2 gas Cerenkov detector (1 atm; threshold of 30 GeV/amu) calibrates the ion chambers in the relativistic rise region. The main emphasis of the instrument is the determination of the change of the ratio of Iron (26) to the Iron secondaries (21-25) in the energy range of 10 to 100 GeV/amu. Preliminary data from a balloon flight in the fall of 1982 from Palestine, TX is presented.

Barthelmy, S. D.

Observations of Cygnus X-3 above 50 keV

Cygnus X-3 was observed in the energy range 50-400 keV using a balloon-borne, actively collimated, NaI(Tl) scintillation detector. The observation was made from phase 0.45-0.91 of the 4.8 hour period. The photon number spectrum was well represented by a power law with index -2.2. The flux increased throughout the observation, consistent with a highly asymmetric light curve with a peak near phase 0.9.

Meegan, C. A.

Visualization of Thermal and Strain Dynamics in X-ray Optics by Time-Resolved Rocking Curve Imaging

The absorption of intense X-ray pulses from free-electron lasers by X-ray crystal optics triggers rapid thermal and mechanical responses, including lattice compression, expan- sion, and strain-wave propagation, which dynamically modify diffraction conditions and wavefront properties. These effects pose significant challenges for next-generation high- repetition-rate X-ray sources, particularly for crystal monochromators used in XFEL beam- lines and self-seeding. Here, we demonstrate time-resolved rocking curve imaging (TrRCI) of X-ray Bragg optics with high spatial resolution (6.4 μm) and sub-1-μrad angular resolu- tion, enabling direct visualization of lattice dynamics from nanoseconds to microseconds. By combining a high-flux beamline at SPring-8, a scintillator-coupled sCMOS detector, and a synchronized femtosecond laser system, we capture lattice dynamics induced by tran- sient laser heating with a strain sensitivity on the order of 10−6 . Our results reveal transient lattice deformation and the propagation of laser-induced strain waves over millimeter-scale distances. This approach provides experimental benchmarks for understanding heat-load effects in high-repetition-rate X-ray optics.

Source record

Measurements on the development of cascades in a tungsten-scintillator ionization spectrometer

The response of a tungsten-scintillator ionization spectrometer to accelerated particle beams has been investigated. Results obtained from exposure of the approx. 1000 g/sq cm apparatus to 5, 10, and 15 GeV/c electrons and pions as well as to 2.1 GeV/nucleon C-12 and O-16 ions are presented. These results include cascade-development curves, fractions of the primary energy measured by the spectrometer, and resolutions of the apparatus for measuring the primary energies. For 15 GeV/c electrons, an average of about 82% of the incident energy is measured by the apparatus with resolution (normal standard deviation) of about 6%. For 15 GeV/c pions, an average of about 65% of the incident energy is measured with resolution of about 18%. The energy resolution improves with increasing energy and with increasing depth of the spectrometer.

Cheshire, D. L.