Search NASA⌕ Search

SEARCH · Search NASA

Results for “Customer interruption costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Consumer Benefits of Clean Energy: The resilience value of residential solar + storage systems in the continental U.S.

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. Clean energy resources that are located behind the meter have the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Solar plus storage systems (PVESS) are clean energy resources that can supply backup power without requiring fuel resupply or increasing local emissions. This report examines the regional value of PVESS for resilience by calculating a benefit-cost ratio (BCR) that considers the annual resiliency benefits of PVESS and the annualized cost of the investment. In addition, we estimate the expected technical mitigation potential of PVESS systems at the county-level to these expected events, and characterize the customer interruption costs by determining the value of lost load at the state level.

14 SOLAR ENERGY↗

ICE Calculator 2: Final Report for Phase 1 and 2 of the National Initiative to Update the Interruption Cost Estimate (ICE) Calculator

ICE 2.0 Phase 2 Final Report In 2021, Berkeley Lab and Resource Innovations, Inc. launched the “ICE Calculator 2 Initiative” – a national study to refresh the underlying data and enhance the functionality of the ICE Calculator. The Initiative involves Berkeley Lab contracting with sponsoring utilities to administer identical, updated and comprehensive interruption cost surveys to statistically representative samples of each utility’s customers. Berkeley Lab and Resource Innovations then pool the survey results across the utilities and use them to update the analytical engines that drive the ICE Calculator. The ICE Calculator 2 Initiative is being conducted in phases. Each phase involves the administration of interruption cost surveys to the customers of sponsoring utilities, followed by an update to the ICE Calculator based on analysis of the pooled survey results. This report describes the activities and findings from Phase 1 and 2 of the ICE Calculator 2 Initiative. Phase 1 was sponsored by eight utilities: American Electric Power, Commonwealth Edison, Dominion Energy, Duke Energy, DTE Electric, Exelon, National Grid, and Puget Sound Energy. Phase 2 was sponsored by six utilities: Empire District Electric Company, Evergy Missouri, Pacific Gas & Electric, San Diego Gas & Electric, Southern California Edison, and Union Electric. Phase 1 and 2 involved 15 customer interruption cost survey activities representing a total of 30 electricity distribution service territories. ICE Calculator Version 2.0 and 2.2 Comparison This memorandum describes–at a high-level–the improvements in interruption cost estimates for the version 2.2 of the ICE Calculator (released February 2026) compared to version 2.0 (released in April 2025). Version 2.2 of the ICE Calculator corresponds to Phase 2 of the initiative, while version 2.0 corresponds to Phase 1. The improvements in version 2.2 result from both a significant increase in the number of customer responses that have been collected and the identification of seven additional factors that help estimate customer interruption costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ICE Calculator 2.0: Final Report for Phase 1 of the National Initiative to Update the Interruption Cost Estimate (ICE) Calculator

In 2021, Berkeley Lab and Resource Innovations, Inc. launched the “ICE 2.0 Initiative” – a national study to refresh the underlying data and enhance the functionality of the ICE Calculator. The Initiative involves Berkeley Lab contracting with sponsoring utilities to administer identical, updated and comprehensive interruption cost surveys to statistically representative samples of each utility’s customers. Berkeley Lab and Resource Innovations then pool the survey results across the utilities and use them to update the analytical engines that drive the ICE Calculator. The ICE 2.0 Initiative is being conducted in phases. Each phase involves the administration of interruption cost surveys to the customers of sponsoring utilities, followed by an update to the ICE Calculator based on analysis of the pooled survey results. This report describes the activities and findings from Phase 1 of the ICE 2.0 Initiative. Phase 1 was sponsored by eight utilities: American Electric Power, Commonwealth Edison, Dominion Energy, Duke Energy, DTE Electric, Exelon, National Grid, and Puget Sound Energy. Phase 1 involved 11 customer interruption cost survey activities representing a total of 24 electricity distribution service territories, 23 of them located in the Eastern and Midwestern regions of the U.S. and one located in the Pacific Northwest. ICE 2.0 vs. 1.0 Comparison This memorandum compares customer power interruption costs estimated using the recently updated Interruption Cost Estimate (ICE) Calculator (“ICE 2.0”) to the original ICE Calculator (“ICE 1.0”). ICE 1.0 was developed in 2009 based on 15 independent power interruption cost surveys conducted by 10 electric utilities between 1989 and 2012. ICE 2.0 was developed in 2025 through a national initiative based on a consistent set of power interruption cost surveys and 11 surveying efforts conducted across 24 electric utility service territories between 2022 and 2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A valuation framework for customers impacted by extreme temperature-related outages

Extreme temperature outages can lead to not just economic losses but also various non-energy impacts (NEI), such as increased mortality rates, property damage, and reduced productivity, due to significant degradation of indoor operating conditions caused by service disruptions. However, existing resilience assessment approaches lack specificity for extreme temperature conditions. They often overlook temperature-related mortality and neglect the customer characteristics and grid response in the calculation, despite the significant influence of these factors on NEI-related economic losses. This paper aims to address these gaps by introducing a comprehensive framework to estimate the impact of resilience enhancement not only on the direct economic losses incurred by customers but also on potential NEI, including mortality and the value of statistical life during extreme temperature-related outages. The proposed resilience valuation integrates customer characteristics and grid response variables based on a scalable grid simulation environment. This study adopts a holistic approach to quantify customer-oriented economic impacts, utilizing probabilistic loss scenarios that incorporate health-related factors and damage/loss models as a function of exposure for valuation. The proposed methodology is demonstrated through comparative resilient outage planning, using grid response models emulating a Texas weather zone during the 2021 winter storm Uri. The case study results show that enhanced outage planning with hardened infrastructure can improve the system resilience and thereby reduce the relative risk of mortality by 16% and save the total costs related to non-energy impacts by 74%. In conclusion, these findings underscore the efficacy of the framework by assessing the financial implications of each case, providing valuable insights for decision-makers and stakeholders involved in extreme-weather related resilience planning for risk management and mitigation strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Residential Vehicle-to-Home Backup Power Capabilities: Key Findings from a ComEd Beneficial Electrification R&D Pilot

This report summarizes key findings from a collaborative technical study of residential, non-grid-tied vehicle-to-home (V2H) backup power systems in Commonwealth Edison’s (ComEd’s) service territory. The work integrates (1) a feeder-level technoeconomic analysis (TEA) using historical outage-event data and simulated electric-vehicle (EV) driving/charging profiles to estimate potential reliability and customer interruption-cost impacts under V2H and vehicle-to-grid (V2G) adoption scenarios; (2) controlled laboratory performance testing of a representative V2H backup ecosystem to characterize transfer-to-backup behavior, sustained power delivery, efficiency trends, and repeatable reliability limitations; and (3) a cybersecurity assessment aligned with NIST Cybersecurity Framework (CSF) 2.0 and ISO/SAE 21434 to evaluate interface-level risk drivers and identify program-relevant mitigations. Results indicate that V2H can provide measurable resilience value, but outcomes are strongly context dependent on outage patterns and the share of events that are “V2H-applicable.” Typical transfer-to-backup behavior clustered on the order of minutes, but rare long-delay edge cases were observed (including an event approaching 30 minutes) and should be treated as a reliability risk. High-power testing showed that peak-rated output is not necessarily continuously deliverable; stable operation may require operation below nameplate ratings and attention to thermal and installation constraints. The cybersecurity assessment highlights a broad attack surface spanning commissioning, home networks, embedded services, and cloud/OTA pathways, motivating minimum controls for secure onboarding, signed updates, patch cadence, and coordinated vulnerability response for any scaled deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Hybrid Approach to Estimating the Economic Value of Enhanced Power System Resilience

The costs that power interruptions impose on customers and society have emerged as essential considerations for decision making about power system reliability and resilience. There is well-established literature on the direct costs of localized and relatively short-duration power interruptions. However, far less is known about the costs of widespread and long-duration (WLD) power interruptions, especially the indirect costs and related economy-wide impacts of these events. As a result, utility planning activities generally incorporate these costs incompletely or not at all. This report proposes a new approach to estimating WLD power interruption costs to support utility resilience planning studies. Specifically, the paper describes a hybrid method that integrates: (1) empirical surveys of region- and sector-specific inherent and adaptive customer behaviors during and after power interruptions, and (2) computable general equilibrium (CGE) modeling, which estimates the direct and indirect impacts of WLD power interruptions. The report provides both a rationale for the proposed hybrid approach and a roadmap outlining how it could be implemented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimates of the Economic Impacts of Long-Duration, Widespread Power Disruptions in Puerto Rico

A typical electricity customer in Puerto Rico experienced nearly 27 hours of power interruptions in 2023–with many customers experiencing extremely long duration outages during a single event (i.e., greater than one month). This project involved conducting state-of-the-art surveying to assess the direct costs of power outages occurring across Puerto Rico, developing customer-specific models to estimate future costs over varying outage durations, and comparing these estimates to FEMA’s Value of Unit Service for Electricity. We estimate that a territory-wide power outage may cost customers $\$1$, $\$5$ and $\$29$ billion during one-, 14-, and 30-day interruptions, respectively. However, these are lower-bound estimates because our study focused on direct economic costs and, by necessity, did not fully incorporate (1) indirect impacts to the economy; (2) costs to repair or replace damaged utility infrastructure; and (3) the broader societal consequences including increased morbidity- and mortality-related costs. The information contained in this study can be used to estimate the direct economic value of past or proposed investments in power system resilience. We conclude with a discussion of this study’s limitations and suggest additional research to improve stakeholder understanding of the impacts of power outages across Puerto Rico.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The resilience value of residential solar + storage systems in the continental U.S.

Abstract Behind the meter rooftop solar plus storage (PVESS) has the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Whereas the bill reduction and environmental benefits of PVESS are well studied, its monetary resilience benefits are less understood. The increasing trend of power interruptions driven by extreme weather events heightens the need to understand these benefits. This study leverages various publicly available datasets to perform a cost benefit analysis of adding to determine the resilience value of PVESS for a typical single family home in each county in the continental U.S. We find that PVESS is very effective to technically mitigate interruptions across the country. However, the monetary benefits in the base case only cover about 14% of battery costs, with no county exceeding 60%. This is somewhat expected, given that PVESS provide other monetary benefits that are not part of this analysis. Through sensitivities, we find that higher frequency of extreme weather events roughly triples the resilience value of PVESS and that higher values of lost load double the same metric. Our sensitivity analysis shows that the benefit cost ratio of PVESS for customers living in areas with higher-than-average frequency of long duration interruptions and value of lost load is already above one even without considering other value streams. We conclude with recommendations that regulators and utilities could implement to enable customers to calculate and capture the resilience value of PVESS more efficiently.

Baik, Sunhee↗

Bill Savings vs. Backup Power: Evaluating operational tradeoffs for home solar+storage systems [Slides]

This study explores tradeoffs between the use of home solar+storage systems for backup power versus day-to-day utility bill savings. The study focuses specifically on the “reserve setting” available with most home battery storage systems, which allow the customer to maintain some minimum level of storage in reserve in case of an unforeseen power interruption. The more capacity that is held in reserve, the greater the customer’s ability to ride-through possible power interruptions, but less capacity is then available to manage utility bills on a day-to-day basis. This study evaluates this operational tradeoff across a diverse set of locations and residential electricity tariff structures, relying on Berkeley Lab’s PRESTO model to stochastically simulate power interruption events, and exploring a range of sensitivities, including variations in customer value of lost load (VoLL), interruption frequency, and other key drivers. The results show that, in most circumstances, the opportunity cost of holding storage capacity in reserve, in terms of foregone bill saving, tends to outweigh any gains in reliability value associated with mitigated power interruptions. This finding is robust across tariff structures and across most of the sensitivities considered, including those related to rate level, customer load level, and storage sizing. There are a limited set of circumstances where raising the reserve setting improves the overall customer value (comprised of bill savings plus reliability value). Specifically, that exception occurs when all of the following conditions apply: (a) the customer resides in a location with exceptionally poor reliability, (b) the customer has exceptionally high VoLL; (c) the customer is on a net billing rate or on a TOU rate that allows grid discharging but not grid charging; and (d), depending on the location, the price arbitrage differential on that rate is relatively small. In all other circumstances analyzed, total customer value declines with reserve level.

14 SOLAR ENERGY↗

Quantifying the economic costs of power outages owing to extreme events: A systematic review

Quantifying the economic cost of long-duration power outages is crucial to justifying investments in resiliency and reliability improvements. However, extensive study on the subject complicates the identification of power outage costs and determining the most suitable approach to quantify them for an individual, specific facility, particularly in the context of extreme events. Here, this research provides a systematic review of economic studies estimating the impact of environmental disasters at the microeconomic and macroeconomic levels. Of 326 articles, evaluating the costs of power outages in extreme events, this work identified 22 studies that attempted to quantify the economic costs. These findings indicate that quantifying power outage costs lacks standardization, posing challenges for comparing different studies. Most analyses aiming to quantify these costs for utilities, sectors, and the overall economy rely on outdated survey data, which offer generalized rather than specific cost estimations. The costs of power outages exhibit a significant dependence on factors such as the sector involved, the type of customer affected, and the outage duration. To quantify industry costs, the research in this study suggests that using the National Renewable Energy Laboratory's online, open-access Customer Damage Function Calculator is the best option for individual-level assessments of industries, hospitals, offices, education centers, and similar facilities. However, the Interruption Cost Estimate Calculator can estimate outage costs across industrial, commercial, and residential sectors for macroeconomic outcomes. Finally, this article discusses the relative strengths of these methods and tools and the potential directions for future research.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Backup power or bill savings? How electricity tariffs impact residential solar-plus-storage usage in the United States

Adoption of paired solar-plus-storage systems has accelerated in recent years, driven by both the demand for backup power and a desire to manage utility bills. Tradeoffs between those two uses can arise through the reserve setting on the battery storage system, which serves to maintain a minimum state of charge in case of a power interruption. Our paper applies an economic framework to evaluate this tradeoff in terms of changes in bill savings and customer reliability value across reserve levels, considering how those tradeoffs depend on the underlying electricity rate structure and levels. The analysis is based on a representative set of load profiles, solar profiles, tariff designs, and stochastic power interruption events across ten different regions in the United States. We find that the opportunity cost of holding storage capacity in reserve, in terms of foregone bill reductions, outweighs any gains in reliability value from mitigated power interruptions in the majority of customer situations. Higher storage reserve levels increase total customer value only in specific circumstances, such as for customers with inferior reliability (10x average interruptions), with a very high value of lost load ($50/kWh), and with tariff or interconnection rules that disallow grid charging. However, even this result is dampened when considering tariff designs with higher price differentials that increase the opportunity cost of holding storage in reserve (e.g. import/export or time-of-use rates). Allowing grid charging in tariffs essentially eliminates the necessity to hold any storage in reserve in all sensitivity cases explored.

Electric resilience↗

Near-Term Electricity Requirement and Emission Implications for Sustainable Aviation Fuel Production with CO 2 -to-Fuels Technologies

Aviation contributed approximately 10% of the U.S. transportation sector's greenhouse gas (GHG) emissions and about 3% of the nation's total GHG production before the coronavirus disease (COVID-19) pandemic (EPA 2022). Unlike the ground transportation sector, which can be decarbonized by using batteries and hydrogen fuel cell powertrain technologies, the technical and economic challenges of aviation electrification open the opportunity for CO 2 utilization (CO2U) using clean power sources. The U.S. government set a goal to produce 3 billion gallons per year of sustainable aviation fuels (SAF) by 2030 and scale up the production to 35 billion gallons per year by 2050 (Bioenergy Technologies Office 2022). In this report, we examine three potential locations, in California, Iowa, and Louisiana, for SAF production using two production pathways that are expected to be available by 2030. We analyze the electricity cost to satisfy 10% of the SAF production potential for the select locations. Specifically, we consider (1) retail electricity cost from the default local utility in each location; (2) physical power purchase agreement (PPA) for renewable power and battery storage hybrid systems with preset prices; (3) financial PPA from a dedicated renewable plant; and (4) estimated real-time pricing (RTP) from the wholesale power market with utility delivery adders. Retail rates are available for the three potential locations; however, the developer should negotiate with the local utility in Iowa for new tariff riders, because the load of the proposed SAF plant (1.4 GW) is significantly higher than the current industrial tariff structure requirement (200 kW). The developers are not able to claim federal credits (i.e., the Inflation Reduction Act of 2022) when sourcing electricity from local utilities. Developers could consider prioritizing physical and financial PPAs as purchase options. While physical PPAs can be imported out of state, this structure imposes availability issues as developers must locate in the same electricity grid regions. Financial PPAs do not have the same location restrictions and provide the same cost savings as physical PPAs, but financial PPAs impose financial risks in the event of system curtailment and grid interruption. RTPs are available for customers in California with flexible load and hourly load management capability; however, utilities in our studied regions in Louisiana and Iowa only offer time-of-use and curtailment programs to incentivize lower energy usage in peak hours. These utilities do not currently offer RTP programs, and the developer may need to have further negotiations with the local utilities to access RTP programs. The results show that purchased electricity prices may range from 2.6 cents/kWh to 7.1 cents/kWh for the three studied plants.

02 PETROLEUM↗

Cost-Benefit Analysis of Electricity Resilience Projects: State of the Art and Gap Analysis

Utilities and regulators must weigh the benefits of electricity resilience projects against their costs, which would be passed on to customers. Cost-benefit analysis (CBA) is an appropriate method for assessing this tradeoff. Here, in this paper we review the literature on CBA of electricity resilience projects and analyze gaps in the available methods and tools. The costs of resilience projects are typically straightforward to estimate but their benefits — particularly the avoided costs of power interruptions — are complex to quantify and monetize. A common perception among practitioners is that current CBA tools are not sufficiently mature to be adopted into real-world practice. We propose an electricity resilience CBA framework consisting of several elements: risks, physical impacts, power interruptions, economic impacts, and resilience projects. While methods for some elements are well-developed, there is a need for novel approaches to value avoided power interruptions, integrate multiple risks and benefit streams, and incorporate uncertainty.

Cost-benefit analysis↗

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

Coal Enhanced PEEK Filament Production for Additive Manufacturing in Industrial Services

The project (Award DE-FE0032146), led by Baker Hughes in collaboration with the University of Wyoming, aims to develop composite PEEK (Polyether-ether-ketone) materials enhanced using coal-derived graphene-based additives suitable for additive manufacturing (3D printing). Coal char (CC), graphene oxide (GO), and reduced graphene oxide (rGO), derived from Powder River Basin (PRB) coal, were successfully integrated into commercial PEEK feedstock. The composite PEEK materials demonstrated tensile and flexural strengths and modulus, Shore hardness, and thermal properties similar to unfilled PEEK. Dielectric strength of 0.5% GO/PEEK is twice that of unfilled PEEK. However, tensile elongation and Izod impact toughness of the composite materials are lower than unfilled PEEK. The 10% CC/PEEK material also shows good recyclability albeit with slightly increased glass transition and cold crystallization temperatures. Filaments of the composite PEEK materials were fabricated using a Filabot system. 3D printing of the composite PEEK initially encountered feeding stoppage caused by the non-uniform diameter of the filament, which was resolved by reducing the nominal diameter from 1.75 to 1.65 mm. The printability of the composite PEEK filaments is limited in geometry and build time, driven by differences in base PEEK feedstock from the commercial PEEK filament at printing conditions. Prototype part printed using the composite filaments shows inconsistent bead width and bead interruption resulting in porosity. Preliminary process and economic evaluation using PRB coal char estimates the cost of GO to be $0.5/lb. Considering the small fraction expected in the composite PEEK, the GO cost is several orders of magnitude lower than the commercial PEEK filament. It is recommended that the printability of composite PEEK filaments to be improved by optimizing the composite PEEK material at the printing conditions and reducing the variations in filament extrusion. Also important is to identify the mechanisms of how coal-derived additives affect the composite PEEK performance and printing characteristics to allow customized material design and processing for target performance.

01 COAL, LIGNITE, AND PEAT↗

VDiSC: An Open Source Framework for Distributed Smart City Vision and Biometric Surveillance Networks

Recent global growth in the interest of smart cities has led to trillions of dollars of investment toward research and development. These connected cities have the potential to create a symbiosis of technology and society and revolutionize the cost of living, safety, ecological sustainability, and quality of life of societies on a world-wide scale. Some key components of the smart city construct are connected smart grids, self-driving cars, federated learning systems, smart utilities, large-scale public transit, and proactive surveillance systems. While exciting in prospect, these technologies and their subsequent integration cannot be attempted without addressing the potential societal impacts of such a high degree of automation and data sharing. Additionally, the feasibility of coordinating so many disparate tasks will require a fast, extensible, unifying framework. To that end, we propose the Distributed Smart City framework for Vision, or VDiSC. VDiSC serves as a unified biometric API harness that allows for seamless evaluation, deployment, and simple pipeline creation for heterogeneous biometric software. VDiSC additionally provides a fully declarative capability for defining and coordinating custom machine learning and sensor pipelines, allowing the distribution of processes across otherwise incompatible hardware and networks. VDiSC ultimately provides a way to quickly configure, hot-swap, and expand large coordinated or federated systems online without interruptions for maintenance. Because much of the data collected in a smart city contains Personally Identifying Information (PII), VDiSC also provides built-in tools and layers to ensure secure and encrypted streaming, storage, and access of PII data across distributed systems.

Brogan, Joel↗

Low-cost buffer storage for solar industrial steam applications

Motivation and importance: Many industrial process heat consumers operate throughout the day, and deep decarbonization with solar energy requires thermal energy storage. Thermal energy storage provides an additional operational benefit of firm delivery of steam – essential to reducing the risk of costly production interruptions. The group of process heat consumers that use steam for biofuels production for the California transportation fuels market is incentivized through the Low Carbon Fuel Standard (LCFS) to reduce their carbon intensity through the use of solar steam. Examples include ethanol and dimethyl ether production. The production of these and other fuels involves distillation driven by steam reboilers with steam pressures in the range 100-280 psig. These pressures can be delivered from the type of thermal energy storage that has been the focus of this project – a steam accumulator Sunvapor, Inc. (SVI) calls a “Bullet Steam Accumulator” or “BSA TM ”. Our project adds to the understanding of the design and integration of steam accumulators charged by solar thermal energy in a biofuels production facility, and similar facilities that consume process steam. The fuel application requires a demanding level of Process Safety Management not found in other steam applications. The type of steam accumulator SVI engineered and built integrates steam generation and storage in one vessel to reduce cost. Achieving a first of a kind permit to operate such a first device has also added to the understanding of the industrial application of such systems. Goals: The overall goal of the project has been to demonstrate the advantages that a “Bullet Steam Accumulator” (BSA™) can provide to solar steam integration with a manufacturing process. The industrial host has already been convinced of the potential of the available solar steam to lower than carbon intensity score. They have been interviewed for a number of publications such as that tout the advantages SVI’s system brings to their operations. Accomplishments: At the end of 2023 Sunvapor placed in service the country’s first industrial solar boiler with thermal energy storage. At the same time, this placement in service represents the first pilot commercial system to decarbonize biofuels production through the use of solar thermal energy. While the full technical effectiveness will be shown as soon as the customer’s plant is able to consume the available steam, the economic feasibility was indicated early in the project when the combination of costs and steam pricing required to meet investor expectations was determined. The project represents a reference pilot from which a full-scale commercial system may be expanded. This pilot is a necessary first step in providing the full potential benefits to the public, including decarbonization of transportation fuels. The decarbonization of the separation steps in fuels production may be the most cost-effective and nearest term solar fuel. Co-benefits include a reduction of air pollutants such as NOx and particulate matter, and job creation for the construction, operation and maintenance of industrial solar facilities.

14 SOLAR ENERGY↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗