Measurable Control System Security through Ideal Driven Technical Metrics

The Department of Homeland Security National Cyber Security Division supported development of a small set of security ideals as a framework to establish measurable control systems security. Based on these ideals, a draft set of proposed technical metrics was developed to allow control systems owner-operators to track improvements or degradations in their individual control systems security posture. The technical metrics development effort included review and evaluation of over thirty metrics-related documents. On the bases of complexity, ambiguity, or misleading and distorting effects the metrics identified during the reviews were determined to be weaker than necessary to aid defense against the myriad threats posed by cyber-terrorism to human safety, as well as to economic prosperity. Using the results of our metrics review and the set of security ideals as a starting point for metrics development, we identified thirteen potential technical metrics - with at least one metric supporting each ideal. Two case study applications of the ideals and thirteen metrics to control systems were then performed to establish potential difficulties in applying both the ideals and the metrics. The case studies resulted in no changes to the ideals, and only a few deletions and refinements to the thirteen potential metrics. This led to a final proposed set of ten core technical metrics. To further validate the security ideals, the modifications made to the original thirteen potential metrics, and the final proposed set of ten core metrics, seven separate control systems security assessments performed over the past three years were reviewed for findings and recommended mitigations. These findings and mitigations were then mapped to the security ideals and metrics to assess gaps in their coverage. The mappings indicated that there are no gaps in the security ideals and that the ten core technical metrics provide significant coverage of standard security issues with 87% coverage. Based on the two case studies and evaluation of the seven assessments, the security ideals demonstrated their value in guiding security thinking. Further, the final set of core technical metrics has been demonstrated to be both usable in the control system environment and provide significant coverage of standard security issues.

99 GENERAL AND MISCELLANEOUS↗

Primer Control System Cyber Security Framework and Technical Metrics

The Department of Homeland Security National Cyber Security Division supported development of a control system cyber security framework and a set of technical metrics to aid owner-operators in tracking control systems security. The framework defines seven relevant cyber security dimensions and provides the foundation for thinking about control system security. Based on the developed security framework, a set of ten technical metrics are recommended that allow control systems owner-operators to track improvements or degradations in their individual control systems security posture.

99 GENERAL AND MISCELLANEOUS↗

Quantifying Availability in SCADA Environments Using the Cyber Security Metric MFC

Supervisory Control and Data Acquisition (SCADA) systems are distributed networks dispersed over large geographic areas that aim to monitor and control industrial processes from remote areas and/or a centralized location. They are used in the management of critical infrastructures such as electric power generation, transmission and distribution, water and sewage, manufacturing/industrial manufacturing as well as oil and gas production. The availability of SCADA systems is tantamount to assuring safety, security and profitability. SCADA systems are the backbone of the national cyber-physical critical infrastructure. Herein, we explore the definition and quantification of an econometric measure of availability, as it applies to SCADA systems; our metric is a specialization of the generic measure of mean failure cost.

Availability↗

Concept for Cyber-Physical Consequence Process

The Department of Homeland Security’s Office of Cyber and Infrastructure Analysis (DHS/OCIA) has a mission and vision that promotes innovation as central to expanding the organization’s capability to conduct consequence analysis. To pursue such innovation, OCIA is sponsoring a seedling effort with Idaho National Laboratory (INL) to leverage data from the proposed Automated Vulnerability Assessment (AVA) capability, which the DHS Science and Technology (S&T) Directorate is developing through a separate INL effort. The first phase of this effort is to develop a process by which recognized vulnerabilities can be scored relative to importance, reflected primarily in the ability to initiate high consequence and potentially cascading events. This report documents a cyber-physical metrics process (CPMP) to tie physical impact to the malicious exploitation of cyber vulnerabilities in industrial control systems (ICS) with the potential for initiating consequence in the critical infrastructure. The scale of achieving any particular physical consequence is dependent upon the ICS Component the vulnerability exists on, the Level of Access that the exploit would allow to component function and the Physical Impact (CLAPI) to the power system that the component is tied. A modified common vulnerability scoring system (CVSS) was detailed and demonstrated for the power sector with three case studies associated with a recognized vulnerability, with significant consequence detail provided to apply the process across the power sector. A detailed table that provides background on the power system components, ICS-enabled monitoring and control, potential consequence effects, and CVSS scoring is provided. To demonstrate the applicability of the CPMP, tables are provided as examples for other sectors that include chemical, water/wastewater and oil/gas.

42 ENGINEERING↗

Cyber Resilient Design and Controls for Energy Systems

As the grid of today is evolving into a highly distributed and autonomous cyber-physical system with higher penetration of Distributed Energy Resources (DERs) and autonomous controls that are dependent on the cyber infrastructure, there are novel and increasing challenges to cyber-resilient operation of the grid. While the traditional mechanisms take a "bolt on" approach to cybersecurity and resiliency, this talk presents two novel technologies developed at NREL that "bake in" security and resilience into the design and control of the grid. An Adaptive Resilience Metrics framework is a novel mechanism for system owners and operators to understand the impact of cyber and physical system design and topology on the resilient operation, while also helping determine optimal policies in response to adverse cyber events. Along with that a zero-knowledge proof-based technique helps incorporate security into the controls layer by focusing on computational integrity rather than data integrity. By leveraging design and control properties unique to Operational Technology systems these technologies will not only help enhance cyber-resilience for the grid of today, but a highly distributed and autonomous grid of tomorrow.

cyber resilience↗

A Review of Cyber-Physical Security for Photovoltaic Systems

In this paper, the challenges and a future vision of the cyber-physical security of photovoltaic (PV) systems are discussed from a firmware, network, PV converter controls, and grid security perspective. The vulnerabilities of PV systems are investigated under a variety of cyber-attacks, ranging from data integrity attacks to software-based attacks. A success rate metric is designed to evaluate the impact and facilitate decision making. Model-based and data-driven methods for threat detection and mitigation are summarized. In addition, the blockchain technology that addresses cyber-attacks in software and cyber networks is described. Simulation and experimental results that show the impact of cyber-attacks at the converter (device) and grid (system) levels are presented. Finally, potential research opportunities are discussed for next-generation, cyber-secure power electronics systems. These opportunities include multi-scale controllability, self-/event-triggering control, artificial intelligence/machine learning, hot patching, and online security. As of today, this study will be one of the few comprehensive studies in this emerging and fast-growing area.

14 SOLAR ENERGY↗

Autonomous Tools for Attack Surface Reduction (Final Report)

The electric power grid is a complex critical infrastructure that forms the lifeline of modern society, and its secure and reliable operation is of paramount importance to national security and economic wellbeing. However, recent findings documented in authoritative sources indicate the threat of cyber-based attacks growing in numbers and sophistication. However, securing the grid against stealthy cyberattacks is a challenging task due to legacy nature of the infrastructure coupled with dynamic nature of threat landscape and ever-growing sophistication of the adversaries. Additionally, the grid’s attack surface continues to grow with the increased dependence on digital communications and control that now extends to each consumer through smart meters and distributed energy resources. Unfortunately, this expansive surface increases the grid’s vulnerability and further exposes critical control systems in both substations and control centers. To respond to this emerging need, we had successfully assembled an interdisciplinary team with academic- industry partnership to successfully conduct research, development, evaluation, demonstration, and commercialization of attack surface reduction tools, whose goal was to significantly reduce the cyber attack surface in the North American power grid. Our proposed project was a synergistic collaborative effort leveraging the synergistic expertise of the team members across power systems, cyber security and CPS security, testbeds, field deployments and demonstration, and successful commercialization. The following are the specific tasks that have been successfully completed two phases (2016-2020). Phase I: Task 1: Developed and implemented a robust Project Management and Data Management Plan, coupled with a well thought out Risk Mitigation Plan. Task 2.1: Developed a comprehensive framework that continually assesses and autonomously reduces the attack surface for the power grid control environment spanning across substations, control center and the SCADA network to significantly reduce the risks of cyber attacks. Task 2.2: Developed attack surface analysis techniques, metrics, and tools that assess the attack surface at multiple levels including the control center, substations, and the SCADA network. Task 2.3: Developed attack surface reduction techniques and tools that dynamically reduce attack surface and hence increase attacker’s cost without interfering in the critical functions of the system. Task 2.4: Prototyped, implemented, and quantitatively evaluated/validated the techniques and tools on a realistic industrial CPS security testbed environment by leveraging the unique resources of the team. Task 3: Developed Commercialization plan to transition the developed tools into power system industry stakeholders for a broader adoption by leveraging the expertise of our industrial members. Phase II: Task 4: Successfully completed field demonstration, verification, and evaluation of the effectiveness of the attack surface analysis and reduction techniques on a realistic utility testbed environment. This also involved the development of realistic scenarios, sound metrics, data sets, evaluation criteria, and documentation. Technology integration & Field demonstration: The project had significantly advanced the state-of-the-art research and practice in improving the cybersecurity of our nation’s power grid infrastructure against cyber threats. In particular, the proposed, designed, and deployed attack surface analysis and reduction algorithms and tools have contributed to significantly reducing the exposure and risk of the devices, substations, and the integrated SCADA/EMS/ DMS grid environment to cyber threat. Strong demonstration and evaluation techniques have verified the feasibility of the developed techniques on realistic cyber-physical testbeds and utility partner's real grid environment, and collaborative research and evaluation of attack surface reduction techniques (for wide-are monitoring and control) within a vendor (GE) EMS platform. The Attack Host Analyzer (AHA) tool that was developed through this project was made available through GitHub.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying the Impact of Unavailability in Cyber-Physical Environments

The Supervisory Control and Data Acquisition (SCADA) system discussed in this work manages a distributed control network for the Tunisian Electric & Gas Utility. The network is dispersed over a large geographic area that monitors and controls the flow of electricity/gas from both remote and centralized locations. The availability of the SCADA system in this context is critical to ensuring the uninterrupted delivery of energy, including safety, security, continuity of operations and revenue. Such SCADA systems are the backbone of national critical cyber-physical infrastructures. Herein, we propose adapting the Mean Failure Cost (MFC) metric for quantifying the cost of unavailability. This new metric combines the classic availability formulation with MFC. The resulting metric, so-called Econometric Availability (EA), offers a computational basis to evaluate a system in terms of the gain/loss ($/hour of operation) that affects each stakeholder due to unavailability.

Availability↗

Risk assessment for Industrial Control Systems quantifying availability using mean failure cost (MFC)

Industrial Control Systems (ICS) are commonly used in industries such as oil and natural gas, transportation, electric, water and wastewater, chemical, pharmaceutical, pulp and paper, food and beverage, as well as discrete manufacturing (e.g., automotive, aerospace, and durable goods.) SCADA systems are generally used to control dispersed assets using centralized data acquisition and supervisory control. Originally, ICS implementations were susceptible primarily to local threats because most of their components were located in physically secure areas (i.e., ICS components were not connected to IT networks or systems). The trend toward integrating ICS systems with IT networks (e.g., efficiency and the Internet of Things) provides significantly less isolation for ICS from the outside world thus creating greater risk due to external threats. Albeit, the availability of ICS/SCADA systems is critical to assuring safety, security and profitability. Such systems form the backbone of our national cyber-physical infrastructure. We extend the concept of mean failure cost (MFC) to address quantifying availability to harmonize well with ICS security risk assessment. This new measure is based on the classic formulation of Availability combined with Mean Failure Cost (MFC). The metric offers a computational basis to estimate the availability of a system in terms of the loss that each stakeholder stands to sustain as a result of security violations or breakdowns (e.g., deliberate malicious failures).

97 MATHEMATICS AND COMPUTING↗

Designing and Operating Through Compromise: Architectural Analysis of CKMS for the Advanced Metering Infrastructure

Compromises attributable to the Advanced Persistent Threat (APT) highlight the necessity for constant vigilance. The APT provides a new perspective on security metrics (e.g., statistics based cyber security) and quantitative risk assessments. We consider design principals and models/tools that provide high assurance for energy delivery systems (EDS) operations regardless of the state of compromise. Cryptographic keys must be securely exchanged, then held and protected on either end of a communications link. This is challenging for a utility with numerous substations that must secure the intelligent electronic devices (IEDs) that may comprise complex control system of systems. For example, distribution and management of keys among the millions of intelligent meters within the Advanced Metering Infrastructure (AMI) is being implemented as part of the National Smart Grid initiative. Without a means for a secure cryptographic key management system (CKMS) no cryptographic solution can be widely deployed to protect the EDS infrastructure from cyber-attack. We consider 1) how security modeling is applied to key management and cyber security concerns on a continuous basis from design through operation, 2) how trusted models and key management architectures greatly impact failure scenarios, and 3) how hardware-enabled trust is a critical element to detecting, surviving, and recovering from attack.

Cryptographic Key Management System (CKMS)↗

Cybersecurity for distributed energy resources and smart inverters

The increased penetration of distributed energy resources (DER) will significantly increase the number of devices that are owned and controlled by consumers and third parties. These devices have a significant dependency on digital communication and control, which presents a growing risk from cyber attacks. This paper proposes a holistic attack-resilient framework to protect the the integrated DER and the critical power grid infrastructure from malicious cyber attacks, helping ensure the secure integration of DER without harming the grid reliability and stability. Specifically, we discuss the architecture of the cyber-physical power system with a high penetration of DER and analyze the unique cybersecurity challenges introduced by DER integration. Next, we summarize important attack scenarios against DER, propose a systematic DER resilience analysis methodology, and develop effective and quantifiable resilience metrics and design principles. Lastly, we introduce attack prevention, detection, and response measures specifically designed for DER integration across cyber, physical device, and utility layers of the future smart grid.

97 MATHEMATICS AND COMPUTING↗

VULCON: A System for Vulnerability Prioritization, Mitigation, and Management

Vulnerability remediation is a critical task in operational software and network security management. In this paper, an effective vulnerability management strategy, called VULCON (VULnerability CONtrol), is developed and evaluated. The strategy is based on two fundamental performance metrics: i). Time-to-Vulnerability Remediation (TVR) and; ii). Total Vulnerability Exposure (TVE). VULCON takes as input real vulnerability scan reports, metadata about the discovered vulnerabilities, asset criticality, and personnel resources. VULCON uses a mixed integer multi-objective optimization algorithm to prioritize vulnerabilities for patching, such that the above performance metrics are optimized subject to the given resource constraints. VULCON has been tested on multiple months of real scan data from a Cyber-Security Operations Center (CSOC). Results indicate an overall Total Vulnerability Exposure reduction of 8.97\% when VULCON optimizes a realistic security analyst workforce's effort. Additionally, it is demonstrated that VULCON can determine monthly resources required to maintain a target TVE score. As such, VULCON provides valuable operational guidance for improving vulnerability response processes in CSOCs.

Farris, Katheryn A.↗

The CYBER security – Competency Health and Maturity Progression (CYBER-CHAMP) model: Extending the National Initiative for Cybersecurity Education (NICE) Framework Across Organizational Security

Problem Statement: There is a pervasive talent deficit in the cybersecurity industry that prevents employers from being able to fill their open positions efficiently. A holistic approach to security is required to ensure organizations have adequate prevention and response capabilities in case of a cyberattack. Specifically, industrial control systems (ICS’s) and their operational technology (OT) components have become a constant target for cyberattacks. Research Questions: It is proposed that the NICE Framework should be extended in the following areas: 1) Include guidance regarding the job roles and competencies for both IT and OT professionals. 2) Offer step-by-step solutions, based on the work role mappings from the NICE Framework, to increase cybersecurity through employee training and education. 3) Provide a streamlined, lifecycle approach to building a cybersecurity program. Contribution: The CYBER security – Competency Health and Maturity Progression (CYBER-CHAMP©) model provides a customized solution for businesses to understand their education gaps in organizational security and target areas for improvement. Rationale: The Framework for Improving Critical Infrastructure Cybersecurity v1.1 addresses ICS but does not offer a measurement of cybersecurity maturity or clear methods to ascertain an organization’s current risk profile. In Phases 1 and 5 of the model, measurements are provided to help an organization build their current and target risk profiles. The NICE framework provides a structure for planning an IT cybersecurity workforce, but the OT aspects of cybersecurity are only briefly discussed. The model uses Phases 2-3 to examine the competencies of an organization’s workforce, which includes both IT and OT roles. Current frameworks do not offer next steps to increase an organization’s cybersecurity. During Phase 4, employees’ roles are mapped to training, education, and/or certifications from common vendors. Investigative Approach: The model provides measurements and metrics for both an organization’s status and continual improvement. This improvement methodology includes guidance for creating an overall strategic plan for security improvement via products designed to increase an organization’s operational readiness through workforce competency health. Lessons Learned: Depending on who was participating, there were contradicting answers given in Phase 1 due to different security cultures in the organization. This revelation has influenced the steps listed in the User’s Guide, where Phase 1’s first recommended step is to assemble a team that champions the facilitation and implementation of the model in the organization. During Phase 2, the discovery was made that organizations may be missing roles that are necessary to perform critical cybersecurity functions. By understanding the functional roles and competencies needed, they can contract or hire cybersecurity help to fill these gaps. Implications: Using the model, organizations can discuss quantitative measures for improvement as a business case for advancing their security program. Future research can validate and extend the present theory and model to a variety of environments. It is of interest to investigate additional security roles and knowledge domains that are used to build standardized cybersecurity curriculum.

97 MATHEMATICS AND COMPUTING↗

A Systematic Comprehensive Computational Model for Stake Estimation in Mission Assurance: Applying Cyber Security Econometrics System (CSES) to Mission Assurance Analysis Protocol (MAAP)

In earlier works, we presented a computational infrastructure that allows an analyst to estimate the security of a system in terms of the loss that each stakeholder stands to sustain as a result of security breakdowns. In this paper, we discuss how this infrastructure can be used in the subject domain of mission assurance as defined as the full life-cycle engineering process to identify and mitigate design, production, test, and field support deficiencies of mission success. We address the opportunity to apply the Cyberspace Security Econometrics System (CSES) to Carnegie Mellon University and Software Engineering Institute s Mission Assurance Analysis Protocol (MAAP) in this context.

97 MATHEMATICS AND COMPUTING↗

Energy Systems Integration Facility Stewardship Summary: Fiscal Year 2025

A summary of NLR's stewardship of the nationally unique Energy Systems Integration Facility (ESIF) highlighting performance metrics, capability upgrades, and examples of R&D impact. 2025 brought a national focus on energy and ESIF is meeting the moment. All eyes are on data centers and domestic manufacturing and bringing the benefits of artificial intelligence to power system planning and operations. In step with national priorities, ESIF is building out capabilities that advance secure, reliable, and affordable power. ESIF hosted 190 multidisciplinary research projects, 855 high-performance computer users, and collaborated with 81 partners from industry, academia, research, and federal agencies. These research projects resulted in an AI method for detecting high-impedance faults with 90% accuracy, a grid controls demonstration in Connecticut, power quality validation of CorePower's flagship inductor, and a cybersecurity assessment of potential rogue capabilities in digitally connected energy devices. Facility infrastructure improvements enhanced the thermal research network, the SCADA system, the cyber range, power hardware-in-the-loop testing, and more. With support from the U.S Department of Energy (DOE), the ESIF laboratories continue to deliver leading solutions for secure, reliable, and affordable power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guided Resilience Self Assessment Application

Reliable electricity access is vital for everything from hospitals to national security. When grid disturbances occur, it is crucial to minimize the amount of time it takes to recover. Grid resiliency considers both the preparation for and recovery from high-impact low-frequency disturbances (HILF) such as weather events and cyber attacks. The Department of Energy (DOE) Wind Energy Technologies Office (WETO) funds the multi-laboratory Microgrids, Infrastructure Resilience, and Advanced Control Launchpad (MIRACL) project to investigate technologies to support and grow distributed wind. Researchers at Idaho National Laboratory (INL) contribute to resilience and cybersecurity efforts for the project, and have produced a resilience framework to evaluate system resilience based on individual system specifications. In order to make this framework easy for anyone to apply, I have coded a web application that allows users to input their power system qualities, goals, and perceived risks and then receive suggestions on how to improve their grid resiliency. The web application follows the seven steps in the planning stage of the framework process, allowing the user to input information about their grid and select from common goals, metrics, and hazards, as well as add their own. The application currently provides information about how to complete each step, requiring minimal prior knowledge of the framework. Future work for this application will include allowing the user to submit line drawings of their system and incorporate modeling tools so that the hazard simulations of applying the framework is completed for the user.

97 MATHEMATICS AND COMPUTING↗

Assessing the Benefits and Implementations of Secure Embedded Intelligence

This is a poster submission, so we do not have a formal abstract; however, we have included a couple of the main points of the poster. Motivation Current ICS/IIoT reference architectures are ill-suited to continue to meet industry demands. Architectures such as the Purdue Model and ISA-95 split cyber-physical systems into distinct levels; however, business needs and cybersecurity requirements constantly require cross-cutting solutions. Further, newly defined IIoT architectures are better suited for Industry 4.0 systems, but they leave out the feedback seen in Purdue and ISA-95. This underscores a need for new architectures, without which IT and OT boundaries will continue to grow. Secure embedded intelligence (SEI) should drive the creation of these new architectures. Secure Embedded Intelligence Advances in sensing, computation, and automated analysis have opened new possibilities for increased security, performance, and cost savings. SEI enables advanced technology to be utilized to drive new reference architectures to achieve these possibilities while integrating trust and risk.

99 GENERAL AND MISCELLANEOUS↗

Proactive routing mutation against stealthy Distributed Denial of Service attacks: metrics, modeling, and analysis

The Infrastructure Distributed Denial of Service (IDDoS) attacks continue to be one of the most devastating challenges facing cyber systems. The new generation of IDDoS attacks exploit the inherent weakness of cyber infrastructure including deterministic nature of routes, skew distribution of flows, and Internet ossification to discover the network critical links and launch highly stealthy flooding attacks that are not observable at the victim end. In this paper, first, we propose a new metric to quantitatively measure the potential susceptibility of any arbitrary target server or domain to stealthy IDDoS attacks, and es- timate the impact of such susceptibility on enterprises. Second, we develop a proactive route mutation technique to minimize the susceptibility to these attacks by dynamically changing the flow paths periodically to invalidate the adversary knowledge about the network and avoid targeted critical links. Our proposed approach actively changes these network paths while satisfying security and qualify of service requirements. We present an integrated approach of proactive route mutation that combines both infrastructure-based mutation that is based on reconfiguration of switches and routers, and middle-box approach that uses an overlay of end-point proxies to construct a virtual network path free of critical links to reach a destination. We implemented the proactive path mutation technique on a Software Defined Network using the OpendDaylight controller to demonstrate a feasible deployment of this approach. Our evaluation validates the correctness, effectiveness, and scalability of the proposed approaches.

ARC↗