Robust Dynamic Watermarking for Cyber-Physical Security of Inverter-Based Resources in Power Distribution Systems
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Physical security is increasingly facing new threats from cyber attackers, for which there is little research in the way of characterizing this threat. This report discusses the efforts to combine cyber and physical security modeling tools to investigate this novel combinatorial threat space. To accomplish this, the Dante force-on-force modeling and simulation software and the Advanced Reactor Cyber Analysis and Development Environment (ARCADE) were integrated. Dante provides a 3D environment which models the physical world, while ARCADE provides the cyber and control systems world.
Explore the source record for details and available documents.
Cyber-Physical Systems (CPSs) are becoming increasingly complex and interconnected as they attempt to meet the demands of evolving society. As a result, monitoring and maintaining them becomes a more complex and demanding task for control system operators and cyber defenders. While the literature on visualization techniques in the context of cybersecurity is extensive, the same cannot be said for studies on visualization for the security of cyber-physical systems. This paper aims to fill that gap by: 1) defining the main features of a visualizations workflow for security visualizations in cyber-physical systems. The workflow includes the acquisition of cyber and physical data, processing of data, selection, and configuration of both visualization tools and end-user interactions. 2) Providing an overview of cyber-physical security visualization systems, with a focus on smart grids as a case study. Finally, we use the perspectives gained from this analysis to provide insights and directions for future research and design of cyber-physical visualization techniques.
Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.
Despite the IEEE Power Electronics Society (PELS) establishing Technical Committee 10 on Design Methodologies with a focus on the cyber-physical security of power electronics systems, a holistic design methodology for addressing security vulnerabilities remains underdeveloped. This gap largely stems from the limited integration of computer science and power/control engineering studies in this interdisciplinary field. Addressing the inadequacy of unilateral cyber or control perspectives, this article presents a novel four-layer cyber-physical security model specifically designed for electric machine drives. Central to this model is the innovative control information flow (CIF) model, residing within the control layer, which serves as a pivotal link between the cyber layer's vulnerable resources and the physical layer's state-space models. By mapping vulnerable resources to control variable space and tracing attack propagation, the CIF model facilitates accurate impact predictions based on tainted control laws. The effectiveness and validity of this proposed model are demonstrated through hardware experiments involving two typical cyber-attack scenarios, underscoring its potential as a comprehensive framework for multidisciplinary security strategies.
In this paper, the challenges and a future vision of the cyber-physical security of photovoltaic (PV) systems are discussed from a firmware, network, PV converter controls, and grid security perspective. The vulnerabilities of PV systems are investigated under a variety of cyber-attacks, ranging from data integrity attacks to software-based attacks. A success rate metric is designed to evaluate the impact and facilitate decision making. Model-based and data-driven methods for threat detection and mitigation are summarized. In addition, the blockchain technology that addresses cyber-attacks in software and cyber networks is described. Simulation and experimental results that show the impact of cyber-attacks at the converter (device) and grid (system) levels are presented. Finally, potential research opportunities are discussed for next-generation, cyber-secure power electronics systems. These opportunities include multi-scale controllability, self-/event-triggering control, artificial intelligence/machine learning, hot patching, and online security. As of today, this study will be one of the few comprehensive studies in this emerging and fast-growing area.
In the last decades, modem grids with distributed energy resources, such as photovoltaic (PV) farms, are increasingly vulnerable to cyber-attacks that seriously affect the stability and performance of the power system. While cyber-physical security of smart grids is extensively studied, most of the existing work focuses on the grid level and neglects the modeling and features of device-level power electronics converters (PECs). Furthermore, establishing a high-fidelity simulation testbed that can simulate harmonic frequencies of the PV farm is in urgent need. In this paper, a high-fidelity and real-time hardware-in- the-loop testbed is built to simulate the harmonics of power electronics converters for cyber-physical security of PEC-enabled PV farms. Based on this testbed, the impact of typical cyber-attacks and physical faults on the PV converter can be analyzed, thus providing a foundation for cyber-attack detection, root cause diagnosis, and resilient control to mitigate the adverse effects of cyber-attacks.
As smart buildings move towards open communication technologies, providing access to the Building Automation System (BAS) through the building's intranet, or even remotely through the Internet, has become a common practice. However, BAS was historically developed as a closed environment and designed with limited cyber-security considerations. Thus, smart buildings are vulnerable to cyber-attacks with the increased accessibility. This study introduces the development and capability of a Hardware-in-the-Loop (HIT) testbed for testing and evaluating the cyber-physical security of typical BASs in smart buildings. The testbed consists of three subsystems: (1) a real-time HIL emulator simulating the behavior of a virtual building as well as the Heating, Ventilation, and Air Conditioning (HVAC) equipment via a dynamic simulation in Modelica; (2) a set of real HVAC controllers monitoring the virtual building operation and providing local control signals to control HVAC equipment in the HIL emulator; and (3) a BAS server along with a web-based service for users to fully access the schedule, setpoints, trends, alarms, and other control functions of the HVAC controllers remotely through the BACnet network. The server generates rule-based setpoints to local HVAC controllers. Based on these three subsystems, the HIL testbed supports attack/fault-free and attack/fault-injection experiments at various levels of the building system. The resulting test data can be used to inform the building community and support the cyber-physical security technology transfer to the building industry.
The presentation would provide how Module-OT could provide security to the cyber physical systems that are interacting with digital, analog, physical, and human components.
Modern infrastructure systems, such as bridges, dams, power generation stations, and buildings increasingly have an intrinsic cyber-physical nature to them. Infrastructure now commonly, includes actuators, network connections, sensors, control systems, and computational resources. It is of increasing concern that modern infrastructure is vulnerable to cyber-attacks that can damage both the cyber and physical nature of the infrastructure. To date, the physical and cyber health of infrastructure has been considered separately. However, the increasing concerns associated with the cyber-physical security of infrastructure coupled with the emergence of 5G networks made using components that are not universally considered trustworthy, and the emergence of techniques for creating deepfakes and adversarial examples suggests the time has come to begin considering cyber health and structural health with a more holistic approach. In this work, a protocol is developed for ensuring the imagery data captured by a structural health monitoring system can be unambiguously attributed to legitimate sensors associated with the structural health monitoring system. A computer vision approach based on the idea of mutual information is then presented to detect damage in an image. This work presents the protocol for authenticating the provenance of imager data and demonstrates that this protocol does not have overly adverse effects when used with the mutual information-based technique for detecting damage in the resulting imagery data.
With the evolution of PV converters, a growing number of vulnerabilities in PV farms are exposing to cyber threats. To mitigate the influence of cyber-attack on PV farms, it is necessary to study attacks' impact and propose detection methods. To meet this requirement, a cyber-physical security framework is proposed for PV farms. Data integrity attacks (DIAs) are studied on different control loops. As μPMU is gaining in popularity, a lower sampling rate of μPMU data is applied to develop a detection algorithm. We have evaluated two data-driven methods, which are support vector machine (SVM) and long short-term memory (LSTM). Lastly, the data-driven methods verify the feasibility of μPMU data in attack detection.
The identification of the Stuxnet worm in 2010 provided a highly publicized example of a cyber attack that physically damaged an industrial control system. This raised public awareness about the possibility of similar attacks against other industrial targets—including critical infrastructure. Here, we use hypergames to analyze how strategic perturbations of sensor readings and calibrated parameters can be used to manipulate a system that employs optimal control. Hypergames form an extension of game theory that enables us to model strategic interactions where the players may have significantly different perceptions of the game(s) they are playing. Past work with hypergames has focused on relatively simple interactions consisting of a small set of discrete choices for each player. Here, we apply single-stage hypergames to larger systems with continuous variables. We find that manipulating constraints can be a more effective attacker strategy than manipulating objective function parameters. Moreover, the attacker need not change the underlying system to carry out a successful attack—it may be sufficient to deceive the defender controlling the system. It is possible to scale our approach up to even larger systems, but this will depend on the characteristics of the system in question, and we identify several characteristics that will make those systems amenable to hypergame analysis.
The Air Traffic Management (ATM) Testbed is being developed at NASA to enable benefit, impact, safety and cost assessments for accelerating the deployment of Concept and Technologies (C&T) in the National Airspace System (NAS). Today, C&T introduction into the NAS takes decades. The primary reason for this is an inability to assess the operational impact of the interaction between the proposed C&T and operationally deployed systems (Realistic Technologies) in terms of NAS-wide safety, traffic flow efficiency, roles and workload of controllers and traffic managers, and impact on airline fleet operations. Transition of C&T to operations requires mathematical modeling and simulation, Human-in-the-Loop (HITL) testing and shadow-mode evaluation driven by operational data. Whereas interaction with the operational system during testing and stages of deployment is not permissible due to safety concerns, it is certainly possible to create a simulation environment that closely mimics the NAS using the same operational systems/hardware for enabling such assessments. This presentation focuses on a proposed Cyber Physical Security extension to the ATM Testbed for creating a modeling and simulation architecture to study how well the Air Traffic Management system will perform and analyze effectiveness of mitigating security measures against particular cyber-attack scenarios.
The Canada-US Blended Cyber-Physical Exercise was a successful, first of its kind, multiorganization and multi-laboratory exercise that culminated years of complex system development and planning. The project aimed to answer three driving research questions, (1) How do cyberattacks support malicious acts leading to theft or sabotage [at a nuclear site]? (2) What are aspects of an effective combined cyber-physical response? (3) How to evaluate effectiveness of that response? Which derived the following primary objectives, 1. The May 2023 Cyber-Physical Exercise shall present a cyber-attack scenario that supports malicious acts leading to theft or sabotage. 2. The May 2023 Cyber-Physical Exercise shall define aspects of an effective combined cyber-physical response. 3. Analysis of the May 2023 Cyber-Physical Exercise shall evaluate the effectiveness of the incident response against pre-established exercise evaluation criteria. 4. Analysis of the May 2023 Cyber-Physical Exercise shall assess the effectiveness of the evaluation criteria itself. 5. Exercises shall be performed in a real-life environment. The team believes these objectives were met, and the evidence will be presented in this report. Due to the novelty of the exercise, there were several lessons learned that will be presented in this report.
As today's power grid is evolving into a densely interconnected cyber-physical system (CPS), a high fidelity and multifaceted testbed environment is needed to perform cybersecurity experiments in a realistic grid environment. Traditional standalone CPS testbeds lack the ability to emulate complex cyber-physical interdependencies between multiple smart grid domains in a real-time environment. Therefore, there are ongoing research and development (R&D) efforts to develop an interconnected CPS testbed by sharing geographically dispersed testbed resources to perform distributed simulation while analysing simulation fidelity. This paper presents a networked federation testbed for cybersecurity evaluation of today's and emerging smart grid environments. Specifically, it presents two novel testbed architectures, including cyber federation and cyber-physical federation, identifies R&D applications, and also describes testbed building blocks with experimental case studies. It also presents a novel co-simulation interface algorithm to facilitate distributed simulation within cyber-physical federation. The resources available at the PowerCyber CPS security testbed at Iowa State University (ISU) and the US Army Research Laboratory are utilised to develop this platform for performing multiple experimental case studies pertaining to wide-area protection and control applications in power system. Finally, experimental results are presented to analyse the simulation fidelity and real-time performance of the testbed federation.
Smart Grid (SG) research and development has drawn much attention from academia, industry and government due to the great impact it will have on society, economics and the environment. Securing the SG is a considerably significant challenge due the increased dependency on communication networks to assist in physical process control, exposing them to various cyber-threats. In addition to attacks that change measurement values using False Data Injection (FDI) techniques, attacks on the communication network may disrupt the power system's real-time operation by intercepting messages, or by flooding the communication channels with unnecessary data. Addressing these attacks requires a cross-layer approach. In this paper a cross-layered strategy is presented, called Cross-Layer Ensemble CorrDet with Adaptive Statistics(CECD-AS), which integrates the detection of faulty SG measurement data as well as inconsistent network inter-arrival times and transmission delays for more reliable and accurate anomaly detection and attack interpretation. Numerical results show that CECD-AS can detect multiple False Data Injections, Denial of Service (DoS) and Man In The Middle (MITM) attacks with a high F1-score compared to current approaches that only use SG measurement data for detection such as the traditional physics-based State Estimation, Ensemble CorrDet with Adaptive Statistics strategy and other machine learning classification-based detection schemes.
Hydropower facilities are often remotely monitored or controlled from a centralized remote control room. Additionally, major component manufacturers monitor the performance of installed components, increasingly via public communication infrastructures. While these communications enable efficiencies and increased reliability, they also expand the cyber-attack surface. Communications may use the internet to remote control a facility’s control systems, or it may involve sending control commands over a network from a control room to a machine. The content could be encrypted and decrypted using a public key to protect the communicated information. These cryptographic encoding and decoding schemes become vulnerable as more advances are made in computer technologies, such as quantum computing. In contrast, quantum key distribution (QKD) and other quantum cryptographic protocols are not based upon a computational problem, and offer an alternative to symmetric cryptography in some scenarios. Although the underlying mechanism of quantum cryptogrpahic protocols such as QKD ensure that any attempt by an adversary to observe the quantum part of the protocol will result in a detectable signature as an increased error rate, potentially even preventing key generation, it serves as a warning for further investigation. In QKD, when the error rate is low enough and enough photons have been detected, a shared private key can be generated known only to the sender and receiver. We describe how this novel technology and its several modalities could benefit the critical infrastructures of dams or hydropower facilities. The presented discussions may be viewed as a precursor to a quantum cybersecurity roadmap for the identification of relevant threats and mitigation.