At least 19 records

Brief: Daily Performance Changes in Metal Halide Perovskite PV Modules

Metal halide perovskite photovoltaic modules deployed outdoors and held at their maximum power point show daily, reversible, relative changes of up to 30% in efficiency between morning and afternoon. Predicting energy yield and quantifying reliability will require properly handling such daily performance changes.

14 SOLAR ENERGY↗

Analysis of Daily, Seasonal, and Interannual Changes in Hofsjokull Ice Cap, Iceland, using Satellite Data

Analysis of a time series of European Remote Sensing Satellite (ERS)-1 and -2, RADARSAT ScanSAR synthetic aperture radar (SAR) and Landsat images from 1973 to 1998, shows daily to interannual changes in Hofsjokull, a 923 sq km ice cap in central Iceland. A digital elevation model of Hofsjokull was constructed using interferometry, and then SAR backscatter coefficient (d) was plotted with elevation, and air temperature along a transect across the ice cap. Most of the a' changes measured along the transect are caused by a change in the state (frozen or thawed) of the surficial snow or ice when air temperature rises above or below about -5 to O C. Seasonal (sigma)deg patterns are identified in a 4-year time series of 57 ERS-1 and -2 images. In addition, June 1997 ScanSAR images display rapid changes in brightness that are tied closely to daily meteorological events. SAR and Landsat data were also used to measure changes in the areal extent of Hofsjokull, from 1973 to 1997, and to locate (sigma)deg and reflectance boundaries that relate to the glacier facies. Late-summer 1997 (sigma)deg and reflectance boundaries agree and are coincident with the approximate location of the fim line, and the January 1998 position of the equilibrium line as determined from ERS-2 data.

Hall, D. K.↗

SU-E-T-89: Comprehensive Quality Assurance Phantom for the Small Animal Radiation Research Platform

Purpose: Use of Small Animal Radiation Research Platform (SARRP) systems for conducting state-of-the-art image guided radiotherapy (IGRT) research on small animals has become more common over the past years. The purpose of this work is to develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the SARRP. Methods: A QA phantom was developed for carrying out daily, monthly and annual QA tasks including imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of nine (60×60×5 mm3) KV-energy tissue equivalent solid water slabs that can be employed for annual dosimetry QA with film. Three of the top slabs are replaceable with ones incorporating Mosfets or OSLDs arranged in a quincunx pattern, or a slab drilled to accommodate an ion chamber insert. These top slabs are designed to facilitate routine daily and monthly QA tasks such as output constancy, isocenter congruency test, treatment planning system (TPS) QA, etc. One slab is designed with inserts for image QA. A prototype of the phantom was applied to test the performance of the imaging, planning and treatment delivery systems. Results: Output constancy test results showed daily variations within 3%. For isocenter congruency test, the phantom could be used to detect 0.3 mm deviations of the CBCT isocenter from the radiation isocenter. Using the Mosfet in phantom as target, the difference between TPS calculations and measurements was within 5%. Image-quality parameters could also be assessed in terms of geometric accuracy, CT number accuracy, linearity, noise and image uniformity, etc. Conclusion: The developed phantom can be employed as a simple tool for comprehensive performance evaluation of the SARRP. The study provides a reference for development of a comprehensive quality assurance program for the SARRP, with proposed tolerances and frequency of required tests.

07 ISOTOPE AND RADIATION SOURCES↗

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal surveillance of volcanoes of the Cascade Range and Iceland utilizing ERTS DCP systems and imagery

The author has identified the following significant results. Significant results of the thermal surveillance of volcanoes experiment during 1972 included the design, construction, emplacement, and successful operation at volcanic sites in the Cascade Range, North America and on Surtsey, Iceland, of automated thermistor arrays which transmit ground and fumarole temperatures via the ERTS-1 data communication system to Goddard Space Flight Center. Temperature, radiance, and anomalous heat flow variations are being plotted by a U.S. Geological Survey IBM 360/65 computer program to show daily fluctuations at each of the sites. Results are being compiled in conjunction with NASA and USGS aircraft infrared survey data to provide thermal energy yield estimates during the current repose period of several Cascade Range volcanic systems. ERTS-1 MSS images have provided new information on the extent of structural elements controlling thermal emission at Lassen Volcanic National Park.

Friedman, J. D.↗

Lunar Curatorial Facility Resource

This video shows daily activities in the Lunar Curatorial Facility. The video covers the various studies being conducted on lunar dust, rock, and core samples brought back by Apollo crews.

Source record↗

The mammalian retina as a clock

Many physiological, cellular, and biochemical parameters in the retina of vertebrates show daily rhythms that, in many cases, also persist under constant conditions. This demonstrates that they are driven by a circadian pacemaker. The presence of an autonomous circadian clock in the retina of vertebrates was first demonstrated in Xenopus laevis and then, several years later, in mammals. In X. laevis and in chicken, the retinal circadian pacemaker has been localized in the photoreceptor layer, whereas in mammals, such information is not yet available. Recent advances in molecular techniques have led to the identification of a group of genes that are believed to constitute the molecular core of the circadian clock. These genes are expressed in the retina, although with a slightly different 24-h profile from that observed in the central circadian pacemaker. This result suggests that some difference (at the molecular level) may exist between the retinal clock and the clock located in the suprachiasmatic nuclei of hypothalamus. The present review will focus on the current knowledge of the retinal rhythmicity and the mechanisms responsible for its control.

Review Literature↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

Economic Dispatch Optimization of Multi-Unit SMR Site

With the increase of integration of variable renewable into the grid, grid resilience can be compromised without flexible electricity suppliers. Flexible operation of NPP can expand the scope of integration of new nuclear power plants in regions with high share of renewables. It also provides opportunity to increase profits through participation in ancillary services. In this research, NuScale modules are used as the case study. NuScale is an integrated pressurized water reactor with thermal power of 250 MWth. Having multiple units can provide higher flexibility in changing power levels and supplying the grid with electricity all year long. Additionally, load-following might perturbate the ordered sequence of refueling (every 24 months for NuScale). To maintain the 2 year refueling cycles, the loading patterns will need to be adjusted in a year-to-year basis, resulting in additional unnecessary costs. Another solution is to find the optimal outage schedule. This will also shift the focus of the planned outage to a more optimized predictive outages and maintenance. Results from short-term optimization (i.e., daily participation in energy and ancillary services markets) shows that average commitment to regulation down ancillary service markets during late night and early morning hours can increase revenues. Participating in upward reserves during pre-work commuting hours and early evening hours can also generate additional revenues due to high ramp up of electricity demand. Having multiple units at a single site can also help operate flexibly. Results from long-term optimization show that daily fluctuation in electric power is usually handled by few units while other units operate on base-load profile. It is possible to combine base-load operation with flexible operation to extend component remaining useful life in some units and find optimal outage schedule for the units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Broad features of surface ozone variations over Indian region

Surface ozone concentration at three Indian stations - New Delhi (28.6 deg N), Pune (18.5 deg N) and Thiruvananthapuram (formerly Trivandrum (8.3 deg N) - has been measured since 1973 with the help of an electrochemical continuous ozone recorder. These stations show diurnal, seasonal and annual cycles in surface ozone. Daily changes show that the minimum value occurs at sunrise and maximum in the afternoon. As regards seasonal variations, Thiruvananthapuram and Pune have a minimum value during monsoon season (June to August) while at New Delhi the minimum value occurs in January. However, New Delhi also records low ozone amount during monsoon season identical to the amounts show at Thiruvananthapuram and Pune. The annual cycles at these stations have been compared with similar measurements in the northern and southern hemispheres. The Indian measurements agree well with the annual cycles at these stations. Further, the analysis of the Indian data indicates that the major contribution in surface ozone comes from the natural sources like stratospheric-tropospheric exchange, turbulence, and mixing in the boundary layer; however, a small contribution from anthropogenic sources cannot be ruled out at Pune and probably at New Delhi, especially in winter and summer seasons.

Shende, R. R.↗

SU-E-J-214: Comparative Assessment On IGRT On Partial Bladder Cancer Treatment Between CT-On-Rails (CTOR) and KV Cone Beam CT (CBCT)

Purpose: Image-Guided radiation therapy(IGRT) depends on reliable online patient-specific anatomy information to address random and progressive anatomy changes. Large margins have been suggested to bladder cancer treatment due to large daily bladder anatomy variation. KV Cone beam CT(CBCT) has been used in IGRT localization prevalently; however, its lack of soft tissue contrast makes clinicians hesitate to perform daily soft tissue alignment with CBCT for partial bladder cancer treatment. This study compares the localization uncertainties of bladder cancer IGRT using CTon- Rails(CTOR) and CBCT. Methods: Three T2N0M0 bladder cancer patients (total of 66 Gy to partial bladder alone) were localized daily with either CTOR or CBCT for their entire treatment course. A total of 71 sets of CTOR and 22 sets of CBCT images were acquired and registered with original planning CT scans by radiation therapists and approved by radiation oncologists for the daily treatment. CTOR scanning entailed 2mm slice thickness, 0.98mm axial voxel size, 120kVp and 240mAs. CBCT used a half fan pelvis protocol from Varian OBI system with 2mm slice thickness, 0.98axial voxel size, 125kVp, and 680mAs. Daily localization distribution was compared. Accuracy of CTOR and CBCT on partial bladder alignment was also evaluated by comparing bladder PTV coverage. Results: 1cm all around PTV margins were used in every patient except target superior limit margin to 0mm due to bowel constraint. Daily shifts on CTOR averaged to 0.48, 0.24, 0.19 mms(SI,Lat,AP directions); CBCT averaged to 0.43, 0.09, 0.19 mms(SI,Lat,AP directions). The CTOR daily localization showed superior results of V100% of PTV(102% CTOR vs. 89% CBCT) and bowel(Dmax 69.5Gy vs. 78Gy CBCT). CTOR images showed much higher contrast on bladder PTV alignment. Conclusion: CTOR daily localization for IGRT is more dosimetrically beneficial for partial bladder cancer treatment than kV CBCT localization and provided better soft tissue PTV identification.

60 APPLIED LIFE SCIENCES↗

Measurements of Declination at the Helsinki Magnetic-meteorological Observatory 1844-1853

A project was started with the goal of putting into computer readable form all the old unpublished magnetic data at the Finnish Meteorological Institute (FMI), the successor of the Helsinki magnetic-meteorological observatory. Altogether there are available about 2.5 million visual observations of D, H and Z made during the time interval 1844-1905. The first 10 year period (1844-1853) of declination data now converted to electronic form, includes observations made at every tenth minute. The total number of observations is 489,152. We present some examples of declination observations in forms of tables and graphs showing hourly, daily, monthly, and annual means. Secular variations of the declination in 1844-1853 have been extremely linear, showing a steady eastward increase of 8 prime/year that is more than two times larger than the present annual rate of secular change in Finland. The standard deviation of the daily and monthly residuals, after removing the secular variation trend for the whole time period, is about 1 prime, demonstrating the high stability and reliability of the observations. For this reason the data may be suitable for deriving a 3-hour activity index K and daily Ak numbers, giving new information for extending the existing long series of activity characters backwards in time.

Nevanlinna, Heikki↗

Field evidences for the positive effects of aerosols on tree growth

Theoretical and eddy-covariance studies demonstrate that aerosol-loading stimulates canopy photosynthesis, but field evidence for the aerosol effect on tree growth is limited. For this study, we measured in-situ daily stem growth rates of aspen trees under a wide range of aerosol-loading in China. The results showed that daily stem growth rates were positively correlated with aerosol-loading, even at exceptionally high aerosol levels. Using structural equation modelling analysis, we showed that variations in stem growth rates can be largely attributed to two environmental variables co-varying with aerosol loading: diffuse fraction of radiation and vapor pressure deficit (VPD). Furthermore, we found that these two factors influence stem growth by influencing photosynthesis from different parts of canopy. By using field observations and a mechanistic photosynthesis model, we demonstrate that photosynthetic rates of both sun and shade leaves increased under high aerosol-loading conditions but for different reasons. For sun leaves, the photosynthetic increase was primarily attributed to the concurrent lower VPD; for shade leaves, the positive aerosol effect was tightly connected with increased diffuse light. Overall, our study provides the first field-evidence of increased tree growth under high aerosol loading. We highlight the importance of understanding biophysical mechanisms of aerosol-meteorology interactions, and incorporating the different pathways of aerosol effects into earth system models to improve the prediction of large-scale aerosol impacts, and the associated vegetation-mediated climate feedbacks.

54 ENVIRONMENTAL SCIENCES↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

The rotation of the Sun: Observations at Stanford

Daily observations of the photospheric rotation rate using the Doppler effect made at the Stanford Solar Observatory since May 1976 are analyzed. Results show that these observations show no daily or long period variations in the rotation rate that exceed the observational error of about one percent. The average rotation rate is the same as that of the sunspot and the large-scale magnetic field structures.

Scherrer, J. M.↗

The rotation of the sun - Observations at Stanford

Daily observations of the photospheric rotation rate using the Doppler effect have been made at the Stanford Solar Observatory since May 1976. These observations show no daily or long-period variations in the rotation rate that exceed the observational error of about 1%. The average rotation rate is the same as that of the sunspots and the large-scale magnetic field structures.

Scherrer, P. H.↗

On the Relationship Between Sub-Daily Instantaneous and Daily Total Gross Primary Production: Implications for Interpreting Satellite-Based SIF Retrievals

Spatially and temporally continuous estimation of plant photosynthetic carbon fixation (or gross primary production, GPP) is crucial to our understanding of the global carbon cycle and the impact of climate change. Besides spatial, seasonal and interannual variations, GPP also exhibits strong diurnal variations. Satellite retrieved solar-induced chlorophyll fluorescence (SIF) provides a spatially continuous, but temporally discrete measurement of plant photosynthesis, and has the potential to be used to estimate GPP at global scale. However, it remains unclear whether the seasonal time series of SIF snapshots taken at a fixed time of the day can be used to infer daily total GPP variation at spatial and seasonal scales. In this study, we first used GPP estimates from 135 eddy covariance flux sites, covering a wide range of geographic locations and biome types, to investigate the relationship between the instantaneous GPP (GPP(sub inst)) and daily GPP (GPP(sub daily)) on the seasonal course for different times of the day. Latitudinal and diurnal patterns were found to correspond to variations in photosynthetically active radiation (PAR) and light use efficiency (LUE), respectively. We then used the Soil-Canopy Observation Photosynthesis and Energy Balance (SCOPE) model and the FluxCom GPP product to investigate the instantaneous and daily SIF-GPP relationships at five flux tower sites along a latitudinal gradient and at a global scale for different biome types. The results showed that daily SIF had a stronger linear correlation with daily GPP than instantaneous SIF at the seasonal scale, with an instantaneous to daily SIF conversion factor following the latitudinal and seasonal pattern driven by PAR. Our study highlights the necessity to take the latitudinal and diurnal factors into consideration for SIF-GPP relationship analyses or for physiological phenology analyses based on SIF.

photosynthesis model↗