National Space Science Data Center data archive and distribution service (NDADS) automated retrieval mail system user's guide

The National Space Science Data Center (NSSDC) has developed an automated data retrieval request service utilizing our Data Archive and Distribution Service (NDADS) computer system. NDADS currently has selected project data written to optical disk platters with the disks residing in a robotic 'jukebox' near-line environment. This allows for rapid and automated access to the data with no staff intervention required. There are also automated help information and user services available that can be accessed. The request system permits an average-size data request to be completed within minutes of the request being sent to NSSDC. A mail message, in the format described in this document, retrieves the data and can send it to a remote site. Also listed in this document are the data currently available.

Perry, Charleen M.↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of hydrogen infrastructure for the feasibility, economics, and sustainability of a fuel cell powered data center

Data centers used for internet data services, cloud computing, and/or data storage consume vast amounts of electricity and are increasing rapidly in capacity. Consequently, their power consumption has raised concerns about energy sustainability and environmental impacts. Large-scale, on-site renewable energy could help reduce data centers’ carbon footprint; however, wind and solar power alone cannot provide an uninterrupted power supply to computer servers due to their natural variability. Instead, reliable power integration can be achieved by using fuel cells powered by hydrogen from sustainable resources (e.g., wind and solar energy). Establishing a hydrogen infrastructure will be critical for realizing these benefits and establishing fuel cells as a viable power source for data centers. Here, to facilitate the development of novel carbon-free fuel cell data enters, this paper presents renewable power integrated with hydrogen infrastructures in four scenarios to provide reliable hydrogen supply from production to storage. Various paths were analyzed toward a hydrogen supply infrastructure by determining the proper component sizes and calculating the cost of meeting the server load. We used a microgrid modeling software, Hybrid Optimization of Multiple Energy Resources (HOMER), and studied the feasibility of fuel cell powered data centers employing renewable hydrogen. The modeling results show various renewable integration configurations to meet reliable and sustainable power requirement under four scenarios for a carbon-free data center.

08 HYDROGEN↗

Wireless Sensor Network for Improving the Energy Efficiency of Data Centers

Data centers occupy less than 2% of the federally owned portfolio under the jurisdiction, custody or control of the U.S. General Services Administration (GSA), but represent nearly 5% of the agency’s overall energy budget. Assuming that energy use in GSA’s data centers tracks with industry averages, GSA can anticipate that data center energy use will grow at an annual rate of 15%, a doubling of energy use every five years.1 In fact, energy is the single largest operating expense for most data centers. Improving the energy performance of data center systems supports progress toward meeting federally mandated greenhouse gas emission-­reduction goals, while reducing operating and energy costs and allowing for greater flexibility in future expansion by eliminating the need to provide additional power and cooling. Studies sponsored by the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA) have shown that energy use can be reduced by 25% through implementation of best practices and commercially available technologies. The present study evaluated the effectiveness of a strategy to cost- effectively improve the efficiency of data center cooling, which is the single largest non-­IT load. The technology that was evaluated consists of a network of wireless sensors—including branch circuit power monitors, temperature sensors, humidity sensors, and pressure sensors, along with an integrated software product to help analyze the collected data. The technology itself does not save energy; however, its information collection and analysis features enable users to understand operating conditions and identify problem areas. In addition, data obtained by this technology can be input into assessment tools that can identify additional best practice measures. Energy savings result from the implementation of the best practices. The study was conducted to validate the premise that providing data center operators with detailed, real- time measurement of environmental parameters and power consumption enables them to establish baseline performance, discover areas of sub-optimal performance, and identify concrete opportunities for improvement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sustainability, Feasibility, and Economics of a Fuel Cell-Powered Data Center

Data centers, used for cloud computing or data storage, consume huge amounts of power and are increasing rapidly in number, and consequently, this increase in power consumption has raised concerns with green and sustainable energy supplies to minimize carbon emissions. Significant renewable power can be a carbon-free energy source to reduce the carbon footprint of a data center; however, direct integration of wind and solar power with data center causes concern of the power quality for uninterrupted power supply to computer servers. The reliable power supply can be accomplished by using power produced from fuel cells fueled by hydrogen. If fed with hydrogen derived from renewable sources, fuel cells will realize carbon-free data centers. This presentation shows various renewable-integration scenarios to meet reliable and sustainable power requirements for a data center.

25 ENERGY STORAGE↗

Energy 101: Energy Efficient Data Centers

Data centers provide mission-critical computing functions vital to the daily operation of top U.S. economic, scientific, and technological organizations. These data centers consume large amounts of energy to run and maintain their computer systems, servers, and associated high-performance components—up to 3% of all U.S. electricity powers data centers. And as more information comes online, data centers will consume even more energy. Data centers can become more energy efficient by incorporating features like power-saving "stand-by" modes, energy monitoring software, and efficient cooling systems instead of energy-intensive air conditioners. These and other efficiency improvements to data centers can produce significant energy savings, reduce the load on the electric grid, and help protect the nation by increasing the reliability of critical computer operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Psychrometric Bin Analysis for Alternative Cooling Strategies in Data Centers

Data centers are significant energy users and require continuous cooling to maintain high levels of computing performance. The majority of data centers have direct-expansion cooling which typically accounts for approximately 50% of the energy usage of data centers. However, using typical meteorological year 3 (TMY3) weather data and a simple psychometric bin analysis, alternative cooling strategies using a combination of economizer, evaporative, and supplemental DX cooling have been shown to be applicable in all climate zones in the United States. Average data center cooling energy savings across the U.S. was approximately 80%. Analysis of cooling energy savings is presented for various ASHRAE climate zones. The psychometric bin analysis is conducted for the ASHRAE recommended and allowable operating environment zones, as well as, a modified allowable operating environment. Control strategies are discussed. Finally, examples of energy efficient data centers using alternative cooling strategies are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Space Science Data Center and World Data Center A for Rockets and Satellites - Ionospheric data holdings and services

The activities and services of the National Space Science data Center (NSSDC) and the World Data Center A for Rockets and Satellites (WDC-A-R and S) are described with special emphasis on ionospheric physics. The present catalog/archive system is explained and future developments are indicated. In addition to the basic data acquisition, archiving, and dissemination functions, ongoing activities include the Central Online Data Directory (CODD), the Coordinated Data Analysis Workshopps (CDAW), the Space Physics Analysis Network (SPAN), advanced data management systems (CD/DIS, NCDS, PLDS), and publication of the NSSDC News, the SPACEWARN Bulletin, and several NSSD reports.

Bilitza, D.↗

Big Federal Data Centers Implementing FAIR Data Principles: ARM Data Center Example

Atmospheric Radiation Measurement (ARM) is a multi-laboratory/multi-institutional, US Department of Energy Office of Science National User Facility. ARM’s data is currently hosted at the ARM Data Center (ADC) in Oak Ridge, Tennessee. The ADC holds more than 12,000 data products, with a total holding of more than 1.8 PB of data that dates back to 1992. This includes data from instruments, value-added products, model outputs, field campaigns, and principle investigator contributed data. In this paper, we discuss how big federal scientific data centers, such as ARM, that use modern and scalable architecture apply findable, accessible, interoperable, and reusable (FAIR) data principles to improve overall efficiency. These principles mainly emphasize machine-to-machine interactions that are directly applicable to ARM because of its data volume.

Devarakonda, Ranjeet↗

National Space Science Data Center (NSSDC) Data Listing

Satellite and nonsatellite data available from the National Space Science Data Center are listed. The Satellite Data listing includes the spacecraft name, launch date, and an alphabetical list of experiments. The Non-Satellite Data listing contains ground based data, models, computer routines, and composite spacecraft data. The data set name, data form code, quantity of data, and the time space covered are included in the data sets of both listings where appropriate. Geodetic tracking data sets are also included.

Source record↗

Implementing the Data Center Energy Productivity Metric in a High Performance Computing Data Center

As data centers proliferate in size and number, the improvement of their energy efficiency and productivity has become an economic and environmental imperative. Making these improvements requires metrics that are robust, interpretable, and practical. We discuss the properties of a number of the proposed metrics of energy efficiency and productivity. In particular, we focus on the Data Center Energy Productivity (DCeP) metric, which is the ratio of useful work produced by the data center to the energy consumed performing that work. We describe our approach for using DCeP as the principal outcome of a designed experiment using a highly instrumented, high-performance computing data center. We found that DCeP was successful in clearly distinguishing different operational states in the data center, thereby validating its utility as a metric for identifying configurations of hardware and software that would improve energy productivity. We also discuss some of the challenges and benefits associated with implementing the DCeP metric, and we examine the efficacy of the metric in making comparisons within a data center and between data centers.

Sego, Landon H.↗

Efficiency and Reliability Analyses of AC and 380V DC Distribution in Data Centers

Modern data centers consume large amounts of electricity, resulting in high operational costs. The efficiency of a data center power distribution system can be increased, and the operational cost reduced, if the number of power conversion stages can be minimized and more efficient converters, such as wide bandgap (WBG) converters, are used. This can be achieved by using DC distribution voltage at the rack level by eliminating extra conversion stages. In this paper, benchmarks for both AC and 380V DC data centers were developed and efficiency analyses were performed for an entire year. The impact of integrating photovoltaic (PV) systems into the data centers has also been analyzed in both cases in terms of efficiency. The results show that 380V DC data centers are more efficient than AC data centers with and without PV integration. Furthermore, the reliability of an AC system was compared to a 380V DC architecture with Tier-IV standard. Monte-Carlo simulations were used to perform reliability analyses for different levels of redundancy in the Uninterruptible Power Supply (UPS) system for both cases. In conclusion, the simulation results showed that the 380V DC distribution system had a higher level of reliability than the AC distribution system in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers

There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical distributions of copper and silver corrosion rates in the sampled data centers(3) To what extent are copper and silver corrosion measurements related (4) What is the relationship of corrosion rate measurements between outside-air cooled data centers compared to closed data centers (5) How do corrosivity measurements relate to IT equipment failure rates The data from our limited sample size suggests that most United States data center operators should not be concerned with environmental gaseous contamination causing high IT equipment failure rates even when using outside-air cooling. The research team recommends additional basic research on how environmental conditions, specifically gaseous contamination, affect electronic equipment reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Goddard Atmospheric Composition Data Center: Aura Data and Services in One Place

The Goddard Atmospheric Composition Data and Information Services Center (AC-DISC) is a portal to the Atmospheric Composition specific, user driven, multi-sensor, on-line, easy access archive and distribution system employing data analysis and visualization, data mining, and other user requested techniques for the better science data usage. It provides convenient access to Atmospheric Composition data and information from various remote-sensing missions, from TOMS, UARS, MODIS, and AIRS, to the most recent data from Aura OMI, MLS, HIRDLS (once these datasets are released to the public), as well as Atmospheric Composition datasets residing at other remote archive site.

Leptoukh, G.↗