Search NASA⌕ Search

SEARCH · Search NASA

Results for “DATA LOGGERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-Mileage Courier Fleet Vehicle On-Road Logger Data

This dataset describes the performance and fuel efficiency of AVTA test vehicles operating in commercial courier fleets the Phoenix, AZ metro area between 2010 and 2016. Aftermarket data loggers were installed in two to four vehicles of each of 30+ distinct year/make/models (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Loggers recorded vehicle operation as they were driven up to 160,000 miles in up to three years of fleet testing. Parameters were logged at 1-second intervals, including - vehicle speed, - engine and/or electric motor speed, - fuel and/or electricity consumption, and - ambient temperature. This dataset includes both raw second-by-second data and trip-level metrics. This dataset is shared by API; a small sample of the vehicle and logger data has been extracted and is also available for download.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Mileage Courier Fleet Vehicle On-road Logger Data

This dataset describes the performance and fuel efficiency of AVTA test vehicles operating in commercial courier fleets the Phoenix, AZ metro area between 2010 and 2016. Aftermarket data loggers were installed in two to four vehicles of each of 30+ distinct year/make/models (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Loggers recorded vehicle operation as they were driven up to 160,000 miles in up to three years of fleet testing. Parameters were logged at 1-second intervals, including - vehicle speed, - engine and/or electric motor speed, - fuel and/or electricity consumption, and - ambient temperature. This dataset includes both raw second-by-second data and trip-level metrics. (This dataset will be shared by API; a small sample of the vehicle and logger data has been extracted and is available for download while the API is being developed.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operating manual for the RRL 8 channel data logger

A data collection device which takes measurements from external sensors at user specified time intervals is described. Three sensor ports are dedicated to temperature, air pressure, and dew point. Five general purpose sensor ports are provided. The user specifies when the measurements are recorded as well as when the information is read or stored in a minicomputer or a paper tape.

Paluch, E. J.↗

Data-Logger Interface And Test Controller

Data-logger interface and test controller developed to enable automation of tests in conjunction with data-acquisition functions performed by data loggers that have output-switching capabilities. Includes relay logic circuits that remain deenergized until out-of-tolerance condition on any data channel discovered. Designed to be connected to Fluke model 2286A (or equivalent) data-logger system, which features 3 control channels with 6 data inputs per channel. Includes elapsed-time counter that keeps track of power outages.

Burch, Donnie R.↗

Cryo-Temp Data Logger

Biological experiments on the ISS are frequently frozen at ultra-low temperatures on orbit prior to return to Earth for analysis. Recording temperatures during the freezing process, and subsequent handling to the point of post-flight processing, can provide important information of sample integrity to the scientist. The MadgeTech Cryo-Temp Data Logger has been modified for space flight applications by the Payload Development Team at Kennedy Space Center. This ultra-low temperature data logger is rated for temperatures from -86 C to +35 C with 0.1 C resolution and +/-1 C accuracy, but has been successfully tested at Kennedy Space Centers Cryogenic Lab down to -100 C. The logger provides date and time stamped temperature recordings and can be set with logging intervals from 5 seconds up to 30 minutes using the MadgeTech Data Logger Software. Data can be recorded, depending on logging interval, for greater than 90 days. The Cryo-Temp Data logger will first be flown on Space X-12 in the BRIC-Petri Dish Fixation Unit (PDFU) canister hardware, recording temperature data for a Space Life and Physical Sciences (SLPS) flight experiment. The modified Cryo-Temp Data Logger is small in size (Figure 1) and is the ideal temperature monitoring solution for any application involving independent temperature data logging.

Logger↗

Portable Data Logger for Photovoltaic Panels

Instrument measures rapidly changing knee of V-I curve with extra care. Portable data logger runs on own batteries. Includes microcomputer, which controls voltage-, current-measurement increment, and solid state memory, which stores data until transferred to EPROM module. Data logger is light, compact and easily caried to remote field locations.

Cole, S. W.↗

Soil Temperature Sensor Data, 2025, Five sites in Knoxville, Tennessee

This dataset contains surface soil temperature measurements from five urban parks in Knoxville, Tennessee: Cumberland Estates Park (CE), Socially Equal Energy Efficient Development (SD), West View Park (WV), Victor Ashe Park (VA), and West Hills Park (WH). The dataset includes 16 CSV files documenting soil temperature measurements recorded by HOBO Pendant MX Water Temperature Data Loggers. Data collection for all sites began on January 1, 2025. The end time for each sensor is provided in the End Time_2025.csv file. Each logger was installed at a depth of 10 inches and positioned approximately 3 to 6 feet from the weather station at each site. This dataset is part of a broader study examining the effects of soil moisture and plant evapotranspiration on ambient temperature and relative humidity across multiple urban parks in Knoxville.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

System and method for measuring sun-induced chlorophyll fluorescence

A chlorophyll fluorescence measuring system having at least one spectrometer coupled to a data logger. The data logger provides direct control of the spectrometer and includes on-board memory for storage of target and reference spectrum data obtained by the spectrometer. The data logger may be coupled to an external computer that receives and analyzes target and reference spectrum data to determine SIF using a spectral fitting algorithm. The system may include a spectrometer aiming system coupled to and controlled by the data logger. The system may also include one or more environmental sensors configured to measure environment variables. The environmental sensors may be coupled to the data logger for control and data storage. The environmental data may be communicated to the external computer for use in the spectral fitting algorithm. The data logger may be connected to a network for remote monitoring and control.

Gu, Lianhong↗

Snow ALbedo eVOlution (SALVO) Campaign Broadband Albedo from April - June, 2024 in Utqiagivk, AK level a1

A field-portable broadband (285 – 2800 nm) albedometer was used to make spatially distributed albedo measurements on tundra and sea ice surfaces. The albedometer consists of paired upward-looking and downward-looking pyranometers, which were both connected to a data logger. The instrument was mounted approximately 1 m above the surface using a tripod and was placed on a 1.4 m-long boom to minimize the impacts of shading from the operator and to observe surfaces undisturbed by footprints (see Appendix for photos of measurement setup and uncertainty assessment). Albedo measurements were taken parallel to the 200-m albedo lines at 5-m increments (41 measurements) ~1.2 m south of the line. On the operator’s end of the boom, there was a bubble level that was aligned with the bubble level on the upward-looking pyranometer. To take a measurement, the operator first relocated the tripod to the measurement location, then leveled the instrument and held it level for at least twice the pyranometers’ response time (5 or 15 seconds, see below), and finally depressed a trigger on the data logger. The data logger recorded the instantaneous voltage on both pyranometers, the measurement number, and the time. The data logger also converted the voltages to irradiances, and from these computed the ratio (outgoing/incoming) for albedo, which could be checked in the field. The operator recorded in a field notebook the measurement number that corresponded with the locations on the line and any pertinent notes (e.g., invalid measurements). With this setup, a trained operator could measure a 200-m albedo line (41 measurements) in approximately 30 minutes. Measurements were made within 3 hours of solar noon. The data logger had sufficient storage capacity to record all measurements from the campaign, but data were downloaded to a computer after each measurement day.

54 ENVIRONMENTAL SCIENCES↗

Sap flow data from San Lorenzo, Panama (PA-SLZ), 2019

This data package contains sap flow data from the NGEE Tropics site in San Lorenzo, Panama (PA-SLZ) from 22 January 2019 to 31 December 2019. Sap flow measurements quantify plant-level transpiration, which varies across spatial and temporal scales. It is a key trait in understanding plant hydraulic functioning. Here sap flow was measured using ‘Granier-type’ thermal dissipation probes. Raw data downloaded from each data logger are in the 'Raw data' folder as CSV files, along with the Campbell data logger programs which can be read when opened with a text editor. The data was processed using the AquaFlux package in R. R code for preparing the data for use in AquaFlux is in the 'R code for pre-processing data folder'; it is saved as a text file that can be copy and pasted into R. The processed data for each data logger is in the 'Processed data' folder as CSV files. Documentation for the Granier sensors and AquaFlux package is in the ‘Manuals’ folder as PDF files.

54 ENVIRONMENTAL SCIENCES↗

Low cost environmental sensors for Spaceflight : NMP Space Environmental Monitor (SEM) requirements

An outstanding problem in spaceflight is the lack of adequate sensors for monitoring the space environment and its effects on engineering systems. By adequate, we mean low cost in terms of mission impact (e.g., low price, low mass/size, low power, low data rate, and low design impact). The New Millennium Program (NMP) is investigating the development of such a low-cost Space Environmental Monitor (SEM) package for inclusion on its technology validation flights. This effort follows from the need by NMP to characterize the space environment during testing so that potential users can extrapolate the test results to end-use conditions. The immediate objective of this effort is to develop a small diagnostic sensor package that could be obtained from commercial sources. Environments being considered are: contamination, atomic oxygen, ionizing radiation, cosmic radiation, EMI, and temperature. This talk describes the requirements and rational for selecting these environments and reviews a preliminary design that includes a micro-controller data logger with data storage and interfaces to the sensors and spacecraft. If successful, such a sensor package could be the basis of a unique, long term program for monitoring the effects of the space environment on spacecraft systems.

Galileo↗

Low Cost Environmental Sensors for Spaceflight: NMP Space Environmental Monitor (SEM) Requirements

An outstanding problem in spaceflight is the lack of adequate sensors for monitoring the space environment and its effects on engineering systems. By adequate, we mean low cost in terms of mission impact (e.g., low price, low mass/size, low power, low data rate, and low design impact). The New Millennium Program (NMP) is investigating the development of such a low-cost Space Environmental Monitor (SEM) package for inclusion on its technology validation flights. This effort follows from the need by NMP to characterize the space environment during testing so that potential users can extrapolate the test results to end-use conditions. The immediate objective of this effort is to develop a small diagnostic sensor package that could be obtained from commercial sources. Environments being considered are: contamination, atomic oxygen, ionizing radiation, cosmic radiation, EMI, and temperature. This talk describes the requirements and rational for selecting these environments and reviews a preliminary design that includes a micro-controller data logger with data storage and interfaces to the sensors and spacecraft. If successful, such a sensor package could be the basis of a unique, long term program for monitoring the effects of the space environment on spacecraft systems.

New Millennium Program (NMP)↗

Flight experience with lightweight, low-power miniaturized instrumentation systems

Engineers at the NASA Dryden Flight Research Facility (NASA-Dryden) have conducted two flight research programs with lightweight, low-power miniaturized instrumentation systems built around commercial data loggers. One program quantified the performance of a radio-controlled model airplane. The other program was a laminar boundary-layer transition experiment on a manned sailplane. The purpose of this article is to report NASA-Dryden personnel's flight experience with the miniaturized instrumentation systems used on these two programs. This article will describe the data loggers, the sensors, and the hardware and software developed to complete the systems. It also describes how the systems were used and covers the challenges encountered to make them work. Examples of raw data and derived results will be shown as well. For some flight research applications where miniaturized instrumentation is a requirement, the authors conclude that commercially available data loggers and sensors are viable alternatives. In fact, the data loggers and sensors make it possible to gather research-quality data in a timely and cost-effective manner.

LOW POWER MINIATURIZED INSTRUM↗

Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?

Variation in the electrical conductivity (EC) of water can reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. Broader application of open source (OS) EC sensors could provide an inexpensive method to measure water quality. While studies show that other water quality parameters can be robustly measured with sensors, a similar effort is needed to evaluate the performance of OS EC sensors. To address this need, we evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. We found a significant difference between OS sensor mean accuracy (3.08%) and all other sensors combined (9.23%). Our study also found that EC sensor precision decreased across all sensor configurations with increasing calibration standard EC. There was also a significant difference between OS sensor mean precision (2.85 μS/cm) and the mean precision of all other sensors combined (9.12 μS/cm). Cable length did not affect OS sensor precision. Furthermore, our results suggest that future research should include evaluating how performance is impacted by combining OS sensors with commercial data loggers as this study found significantly decreased performance in OS/commercial-hybrid sensor configurations. To increase confidence in the reliability of OS sensor data, more studies such as ours are needed to further quantify OS sensor performance in terms of accuracy and precision across different settings and OS sensor and data collection platform configurations.

54 ENVIRONMENTAL SCIENCES↗

MISSE 1 and 2 Tray Temperature Measurements

The Materials International Space Station Experiment (MISSE 1 & 2) was deployed August 10,2001 and retrieved July 30,2005. This experiment is a co-operative endeavor by NASA-LaRC. NASA-GRC, NASA-MSFC, NASA-JSC, the Materials Laboratory at the Air Force Research Laboratory, and the Boeing Phantom Works. The objective of the experiment is to evaluate performance, stability, and long term survivability of materials and components planned for use by NASA and DOD on future LEO, synchronous orbit, and interplanetary space missions. Temperature is an important parameter in the evaluation of space environmental effects on materials. The MISSE 1 & 2 had autonomous temperature data loggers to measure the temperature of each of the four experiment trays. The MISSE tray-temperature data loggers have one external thermistor data channel, and a 12 bit digital converter. The MISSE experiment trays were exposed to the ISS space environment for nearly four times the nominal design lifetime for this experiment. Nevertheless, all of the data loggers provided useful temperature measurements of MISSE. The temperature measurement system has been discussed in a previous paper. This paper presents temperature measurements of MISSE payload experiment carriers (PECs) 1 and 2 experiment trays.

Harvey, Gale A.↗