Search NASA⌕ Search

SEARCH · Search NASA

Results for “DAYLIGHTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Achieving Integrated Daylighting and Electric Lighting Systems: Current State of the Art and Needed Research

This paper presents the results of a multi-disciplinary scoping study, the goals of which were to see the seamless integration and application of light in buildings, regardless of source, that is purposely modulated to illuminate surfaces and designed in a way that is comfortable, healthy, pleasing, cost effective, and energy efficient. The scoping study was performed in order to set the stage for transforming the design and realization of lighting systems integration (daylight and electric). This, in turn, will support achieving the the U.S. Department of Energy’s (DOE) Building Technologies Office (BTO) long-term energy savings goals. Holistic lighting systems of the future should include components that are adaptable to change, resilient to disruption, and robust. The system of codes, standards, guidelines, and contracts employed to design and implement lighting systems should be structured to help them to flourish, rather than being barriers to realization. Finally, the research thrusts and mechanisms should be engaged with these goals in mind. While integrated lighting systems may reduce lighting energy use in buildings, a broader web of non-energy impacts affecting occupant’s overall health, comfort, and satisfaction may also guide technology investment goals when the entire lighting systems lifecycle is considered. Daylighting systems are separated from electric lighting systems, and both are characteristically detached from other systems such as safety, security, communications, and information systems. Being disconnected from the inputs and outputs of other building systems precludes the ability to acquire and utilize information about occupation, status of systems, and interior and exterior environmental conditions. The outcome of this separation is that the standard building is not fulfilling the potential for creating dynamic and holistic lighting for building occupants.

Davis, Robert G.↗

Potential annual daylighting performance of a high-efficiency daylight redirecting slat system

While the primary role of window attachments is often to moderate glare and solar heat gains, they are also able to provide additional daylight to interior spaces. For this purpose, a variety of daylight-redirecting window systems have been developed over the past 150 years. Fixed reflective systems (slats/light shelves) or prismatic systems that rely on total internal reflection work well under specific solar conditions, but generally sacrifice performance over a much wider range of incident solar angles and sky conditions. Dynamic systems - typically reflective slats - are more responsive to sun angles but have not been able to achieve optimal performance for glare and daylight redirection efficiency. A previous investigation into an adjustable, reflective blind concept first conceived of in the late 1970s showed promise but was not reduced to practice due to lack of adequate simulation and analysis tools. In this paper, this concept is further developed and its energy and visual comfort performance evaluated for four mid-latitude, temperate climates using ray-tracing simulation techniques. Overall, results indicate significant potential lighting energy savings when compared with conventional automated reflective blinds (2.1–4.9 kWh/(m 2 ·a), or 14%–42%, depending on climate and orientation) or, especially, manually-operated matte white venetian blinds (1.4–7.9 kWh/(m 2 ·a), or 9%–54%, depending on climate and orientation), while maintaining acceptable or better visual comfort conditions throughout the interior space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the Use of Integrated Daylighting and Energy Simulations to Drive the Design of a Large Net-Zero Energy Office Building: Preprint

This paper illustrates the challenges of integrating rigorous daylight and electric lighting simulation data with whole-building energy models, and defends the need for such integration to achieve aggressive energy savings. Through a case study example, we examine the ways daylighting -- and daylighting simulation -- drove the design of a large net-zero energy project. We give a detailed review of the daylighting and electric lighting design process for the National Renewable Energy Laboratory's Research Support Facility (RSF), a 220,000 ft2 net-zero energy project the author worked on as a daylighting consultant. A review of the issues involved in simulating and validating the daylighting performance of the RSF will be detailed, including daylighting simulation, electric lighting control response, and integration of Radiance simulation data into the building energy model. Daylighting was a key strategy in reaching the contractual energy use goals for the RSF project; the building's program, layout, orientation and interior/furniture design were all influenced by the daylighting design, and simulation was critical in ensuring these many design components worked together in an integrated fashion, and would perform as required to meet a very aggressive energy performance goal, as expressed in a target energy use intensity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large-Scale Daylighting Analysis for Buildings, Products, and Policy

Daylighting in buildings has come under increased scorn in the wake of ubiquitous solid-state lighting (SSL), as installed lighting power densities in buildings have been reduced to the point where designers and owners question the benefits of properly-designed daylighting and electric lighting control. At the same time the very process of demonstrating well-executed daylighting to satisfy new building rating systems has become burdensome. This paper demonstrates the utility of illuminance as an input to simple, existing qualitative and quantitative metrics for daylighting performance in buildings, at scale. This assertion is supported by sensitivity analysis of a large-scale daylighting simulation dataset. Uses of this data for quantifying non-energy benefits (NEBs) of daylighting are also explored. We do not eschew the use of newer, more detailed daylight metrics in design, but we do encourage the use of simple daylight metrics for a broader range of new and retrofit building projects toward a net-zero future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office testbed

Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Microstructured prismatic window films can be manufactured using low-cost, roll-to-roll fabrication methods and adhered to the inside surface of existing windows as a retrofit measure or installed as a replacement insulating glass unit in the clerestory portion of the window wall. A clear film patterned with linear, 50-250 micrometer high, four-sided asymmetrical prisms was fabricated and installed in the south-facing, clerestory low-e, clear glazed windows of a full-scale testbed facility. Views through the film were distorted. The film was evaluated in a sunny climate over a two-year period to gauge daylighting and visual comfort performance. The daylighting aperture was small (window-towall ratio of 0.18) and the lower windows were blocked off to isolate the evaluation to the window film. Workplane illuminance measurements were made in the 4.6 m (15 ft) deep room furnished as a private office. Analysis of discomfort glare was conducted using high dynamic range imaging coupled with the evalglare software tool, which computes the daylight glare probability and other metrics used to evaluate visual discomfort. The window film was found to result in perceptible levels of discomfort glare on clear sunny days from the most conservative view point in the rear of the room looking toward the window. Daylight illuminance levels at the rear of the room were significantly increased above the reference window condition, which was defined as the same glazed clerestory window but with an interior Venetian blind (slat angle set to the cut-off angle), for the equinox to winter solstice period on clear sunny days. For partly cloudy and overcast sky conditions, daylight levels were improved slightly. To reduce glare, the daylighting film was coupled with a diffusing film in an insulating glazing unit. The diffusing film retained the directionality of the redirected light spreading it within a small range of outgoing angles. This solution was found to reduce glare to imperceptible levels while retaining for the most part the illuminance levels achieved solely by the daylighting film.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental demonstration and performance evaluation of a complex fenestration system for daylighting and thermal harvesting

Two significant design strategies for mitigating building energy consumption are daylight redirection and solar energy harvesting. Effective daylighting implementation enhances the amount of useful natural light within a space and offsets the need for electric lighting. Solar energy harvesting systems can mitigate energy costs from mechanical systems by managing incoming thermal loads or capturing solar energy that can be used to supplement thermal systems in the building. While there are many available façade-based technologies that can perform daylighting or solar thermal energy harvesting, there remains a limitation in available systems that can perform both of them simultaneously. This paper, describes the design and experimental demonstration of a Liquid Filled Prismatic Louver (LFPL) system, which combines both energy-saving strategies. The LFPL system was installed in a south-facing room in New York City and evaluated for indoor daylight penetration and potential for thermal energy harvesting. Daylight redirection is achieved through the prismatic louver geometry and proper orientation, whereas thermal energy harvesting is achieved through IR absorption from the liquid (e.g., water) within the prisms. Daylighting performance was evaluated by illuminance measurements at key locations within the space, whereas thermal harvesting performance was evaluated through temperature measurements and thermal imaging analysis. We show that the LFPL system, with all prismatic elements oriented at the same angle, achieve a 2-fold and 8-fold enhancement in daylight redirection to the ceiling, for prism orientations of 10° and 20°, respectively. We also demonstrate the system’s capability to adjust to specific lighting needs, within the space, through the dynamic individual orientation of prismatic elements; thus, achieving a concentrated ceiling illuminance enhancement of ~100 times and ~200 times at 2.5 and 4.3 m away from the window sill, providing workplane illuminance enhancement of 6 and 2 times more than in the case of the control room with regular windows. Furthermore, we illustrate a reduction of potential heating loads at locations close to the window from the combination of infrared absorption in the water volume and the redirection of the incoming solar radiation, leading to a reduction of the workplane temperature by an average of 7–10 °C.

14 SOLAR ENERGY↗

Simulative Prediction of Solar Illuminance and Application of the Du-Sharples Model in Estimating Adapted Daylighting Metrics for an Urban Environment

The practice of daylighting in indoor spaces can significantly reduce electricity consumption and carbon emissions, improve human productivity, and enhance mood and cognitive perception. This work discussed the recent developments in daylighting science and practice, computed the periodic variations in average diurnal daylight levels for each month, quantified in terms of global horizontal illuminance and diffuse horizontal illuminance, for Kolkata, India, a city with tropical wet and dry climate, with two empirical luminous efficacy models of estimating solar illuminance, and assessed daylighting metrics with the Du-Sharples model. A program was formulated that could compute and generate daylight data with monthly-hourly solar irradiation data and the Du-Sharples model was utilized to predict dirt-corrected daylighting metrics for three glazing transmittance values and five elemental carbon deposition levels on glazing material. The highest monthly average global horizontal illuminance is recorded in April (64.05 klx for Littlefair model and 66.82 klx for Muneer-Kinghorn model) and the highest monthly average diffuse horizontal illuminance is recorded in July (33.23 klx for Littlefair model and 30.63 klx for Muneer-Kinghorn model). Further, the computed yearly average global and diffuse horizontal illuminance levels agree well with a previous study that applied the Perez model. Yearly average horizontal work surface illuminance level remained >1.5 klx for window-towall area ratio >30 %. The approach adopted in this work and the temporal variation charts of computed exterior daylight level data may assist building service engineers, architects, and indoor lighting practitioners in making informed policy decisions at different stages of building planning.

Engineering↗

Performance of Anidolic Daylighting Systems in tropical climates - Parametric studies for identification of main influencing factors

Making daylight more available in buildings is highly desirable, not only for reasons of energy-efficiency, but also for improvement of occupants' health and well-being. Core-daylighting, that is daylight provision in areas situated at considerable distances from facades and windows, is currently one of the main challenges in sustainable building design. Anidolic Daylighting Systems (ADSs) are one very promising technology in the field of core-daylighting, but commercial solutions that are not only well-performing but also financially competitive are not yet widely available. This article presents results of parametric studies on Anidolic Integrated Ceilings (AICs), a special type of ADS, for identification of main influencing factors. The article describes a reliable method for simulating ADS and AIC performance under given sky conditions. Various simulation results for the example location Singapore are discussed in detail, it is concluded that the main influencing factors are coating material, system dimensions and external obstruction, and those influencing factors' potential impacts are quantified. It is shown that AIC overall efficiencies can reach up to almost 50% in Singapore. The essentially new results presented in this article can be of great help to architects, engineers and scientists in the future, when it comes to precisely dimensioning ADS for various buildings and daylight conditions. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of Integrated Systems of Automated Roller Shade Systems and Daylight Responsive Dimming Systems

Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane illuminance according to roller shade height and sky conditions for improvement of the system accuracy. In this study, the performance of the integrated systems with two improved closed-loop proportional control algorithms was compared with that of the current (modified) closed-loop proportional control algorithm. In the results, the average maintenance percentage and the average discrepancies of the target illuminance, as well as the average time under 90percent of target illuminance for the integrated systems significantly improved in comparison with the current closed-loop proportional control algorithm for daylight responsive dimming systems as a single system.

30 DIRECT ENERGY CONVERSION↗

Daylight simulation workflows incorporating measured bidirectional scattering distribution functions

Daylight predictions of architectural spaces depend on good estimates of light transfer through skylights, windows and other fenestration systems. For clear glazing and painted surfaces, parametric transmission and reflection models have proven adequate, but there are many cases where light-scattering, semi-specular shading and daylighting materials defy simple characterization. Something as commonplace as fabric roller shades and venetian blinds may turn daylight prediction into guesswork, and numerous advanced systems on the market tuned specifically to enhance daylight are not sufficiently characterized to distinguish their performance. In this paper, we describe new tools available to handle novel and specialized fabrics, materials, and devices using data-driven modelling of bi-directional scattering distribution functions (BSDFs). These representations are usually tabulated at constant or adjustable angular resolution for efficient point-in-time and annual daylight simulations. We describe a variety of BSDF simulation workflows, including some of the tools and methods that make advanced analysis possible, and highlight some of the current challenges. We conclude with a discussion of future work and how such data might be created and shared worldwide.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of integrated daylighting and electric lighting design projects: Lessons learned from international case studies

This article presents and discusses the lessons learned from the monitoring of 25 integrated daylighting and electric lighting international case study projects. The case studies consist of real occupied buildings that have been monitored as part of the International Energy Agency (IEA) SHC Task 61/EBC Annex 77 Programme. The general goal of the case studies was to balance lighting energy use with occupants’ visual and non-visual requirements. This was achieved using innovative solutions for daylighting and electric lighting with advanced controls, but also implementing simple and out-of-the-box strategies. The findings suggest that energy demands for lighting can significantly be reduced by combining sensible daylight provision, efficient lighting sources, and advances in controls. Yet, the effective achievement of project goals requires adequate monitoring, fine-tuning, and verification. The findings also suggest that the adoption of “integrative” lighting – that is, lighting systems that address both visual and non-visual responses – is getting increasingly popular. Catering to non-visual requirements will likely drive further innovation in lighting technology. Currently, there is limited investment available for developing daylighting systems for integrative lighting, and the current related electric strategies often come at the risk of energy rebound effects. Overall, providing daylighting and understanding user requirements are fundamental steps towards achieving quality projects, with potential benefits beyond saving energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Daylighting performance evaluation of a bottom-up motorized roller shade

This paper presents an experimental and simulation study for quantifying the daylighting performance of bottom-up roller shades installed in office spaces. The bottom-up shade is a motorized roller shade that opens from top to bottom operating in the opposite direction of a conventional roller shade, so as to cover the bottom part of the window, while allowing daylight to enter from the top part of the window, reaching deeper into the room. A daylighting simulation model, validated with full-scale experiments, was developed in order to establish correlations between the shade position, outdoor illuminance and work plane illuminance for different outdoor conditions. Then, a shading control algorithm was developed for application in any location and orientation. The validated model was employed for a sensitivity analysis of the impact of shade optical properties and control on the potential energy savings due to the use of daylighting. The results showed that Daylight Autonomy for the bottom-up shade is 8-58% higher compared to a conventional roller shade, with a difference of 46% further away from the facade, where the use of electric lighting is needed most of the time. The potential reduction in energy consumption for lighting is 21-41%. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advocating for view and daylight in buildings: Next steps

With the exponential growth in population and commensurate increased density in urban cities, access to daylight and views to nature is being severely curtailed in buildings. In parallel, increasingly urgent demands to sharply reduce building energy use and associated greenhouse gas emissions are being made to mitigate climate change. There are many challenges and performance tradeoffs associated with the building facade (i.e., daylight and view versus solar and glare control); increased prioritization of health and well-being as a fundamental human requirement could adversely affect building energy-efficiency. Given the current state of knowledge on the effects of daylight and view on health and well-being in buildings, we identify critical needs in research, tools and technologies that if satisfied may enable more effective use of daylight and view in buildings within the constraints of climate change. Lack of knowledge regarding the complex causal mechanisms of window views on human factors is a severely limiting factor in forward progress. Current models and methods to derive bidirectional scattering distribution functions (BSDFs) will need to be modified. Developers of energy-efficient window technologies will need more guidance to shape product development. Advanced window technologies and integrated design can enable attainment of both health and well-being and net zero energy goals, but considerable work will be needed to make such options turnkey and broadly available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing lighting power density in office rooms equipped with Anidolic Daylighting Systems

Electric lighting is responsible for up to one third of an office building's electricity needs. Making daylight more available in office buildings can not only contribute to significant energy savings but also enhance the occupants' performance and wellbeing. Anidolic Daylighting Systems (ADS) are one type of very effective facade-integrated daylighting systems. All south-facing office rooms within the LESO solar experimental building in Lausanne (Switzerland) are equipped with a given type of ADS. A recent study has shown that these offices' occupants are highly satisfied with their lighting environment. The most energy-efficient south-facing offices have a lighting power density of less than 5W/m{sup 2}. The lighting situation within these ''best practice''-offices has been assessed using the lighting simulation software RELUX Vision. Because this lighting situation is very much appreciated by the occupants, it was used as a starting point for developing even more energy-efficient office lighting designs. Two new lighting designs, leading to lighting power densities of 3.9W/m{sup 2} and 3W/m{sup 2}, respectively, have been suggested and simulated with RELUX Vision. Simulation results have shown that the expected performances of these new systems are comparable to that of the current lighting installation within the ''best practice''-offices or even better. These simulation results have been confirmed during experiments on 20 human subjects in a test office room recently set up within the LESO building. This article gives engineers, architects and light planers valuable information and ideas on how to design energy-efficient and comfortable electric lighting systems in office rooms with abundant access to daylight. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acceleration of the matrix multiplication of Radiance three phase daylighting simulations with parallel computing on heterogeneous hardware of personal computer

Building designers are increasingly relying on complex fenestration systems to reduce energy consumed for lighting and HVAC in low energy buildings. Radiance, a lighting simulation program, has been used to conduct daylighting simulations for complex fenestration systems. Depending on the configurations, the simulation can take hours or even days using a personal computer. This paper describes how to accelerate the matrix multiplication portion of a Radiance three-phase daylight simulation by conducting parallel computing on heterogeneous hardware of a personal computer. The algorithm was optimized and the computational part was implemented in parallel using OpenCL. The speed of new approach was evaluated using various daylighting simulation cases on a multicore central processing unit and a graphics processing unit. Based on the measurements and analysis of the time usage for the Radiance daylighting simulation, further speedups can be achieved by using fast I/O devices and storing the data in a binary format.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Daylighting Requirements within ASHRAE Standard 90.1

Pacific Northwest National Laboratory (PNNL), under the Building Energy Codes Program (BECP) funded by U.S. Department of Energy (DOE), provides support to the ASHRAE/IES/IESNA Standard 90.1(Standard 90.1) Standing Standards Project Committee (SSPC 90.1) and its subcommittees. In an effort to provide the ASHRAE SSPC 90.1 with data that will improve the daylighting and fenestration requirements in the Standard, PNNL collaborated with Heschong Mahone Group (HMG), now part of TRC Solutions. Combining EnergyPlus, a whole-building energy simulation software developed by DOE, with Radiance, a highly accurate illumination modeling software (Ward 1994), the daylighting requirements within Standard 90.1 were analyzed in greater detail. The initial scope of the study was to evaluate the impact of the fraction of window area compared to exterior wall area (window-to-wall ratio (WWR)) on energy consumption when daylighting controls are implemented. This scope was expanded to study the impact of fenestration visible transmittance (VT), electric lighting controls and daylighted area on building energy consumption.

90.1↗

A Framework for Daylighting Optimization in Whole Buildings with OpenStudio

We present a toolkit and workflow for leveraging the OpenStudio (Guglielmetti et al. 2010) platform to perform daylighting analysis and optimization in a whole building energy modeling (BEM) context. We have re-implemented OpenStudio's integrated Radiance and EnergyPlus functionality as an OpenStudio Measure. The OpenStudio Radiance Measure works within the OpenStudio Application and Parametric Analysis Tool, as well as the OpenStudio Server large scale analysis framework, allowing a rigorous daylighting simulation to be performed on a single building model or potentially an entire population of programmatically generated models. The Radiance simulation results can automatically inform the broader building energy model, and provide dynamic daylight metrics as a basis for decision. Through introduction and example, this paper illustrates the utility of the OpenStudio building energy modeling platform to leverage existing simulation tools for integrated building energy performance simulation, daylighting analysis, and reportage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Daylight-Mediated, Passive, and Sustained Release of the Glaucoma Drug Timolol from a Contact Lens

Timolol, a potent inhibitor of β-adrenergic receptors (βARs), is a first-line drug for decreasing the intraocular pressure (IOP) of patients with glaucoma. Timolol is administered using 0.5% eye-drop solutions at >3 × 10 7 times the inhibitory concentration ( k i ) for βARs. This high dose is wasteful and triggers off-target effects that increase medication noncompliance. Here, we introduce contact lenses that release timolol to the eye throughout the day during passive exposures to natural daylight at a more therapeutically relevant concentration (>3000 k i ). Timolol is coupled to the polymer of the contact lens via a photocleavable caged cross-linker and is released exclusively to the surrounding fluid after the 400-430 nm mediated cleavage of the cross-linking group. Studies conducted in a preclinical mouse model of glaucoma show photoreleased timolol is effective as authentic timolol in reducing IOP. Our studies highlight several advantages of daylight-mediated release of timolol from lenses compared to eye-drops. First, fitted contact lenses exposed to natural daylight release sufficient timolol to sustain the inhibition of βARs over a 10 h period. Second, the contact lenses inhibit βARs in the eye using only 5.7% of the timolol within a single eye-drop. Third, the lenses allow the patient to passively control the amount of timolol released from the lens-for example, early morning exposure to outdoor sunlight would release enough timolol to maximally reduce the IOP, whereas subsequent periodic exposures to indoor daylight would release sufficient timolol to overcome the effects of its spontaneous dissociation from βARs. Fourth, our lenses are disposable, designed for single day use, and manufactured at a low cost.

60 APPLIED LIFE SCIENCES↗