Search NASA⌕ Search

SEARCH · Search NASA

Results for “DBD plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

DBD Plasma Actuators for Flow Control in Air Vehicles and Jet Engines - Simulation of Flight Conditions in Test Chambers by Density Matching

Dielectric Barrier Discharge (DBD) Plasma actuators for active flow control in aircraft and jet engines need to be tested in the laboratory to characterize their performance at flight operating conditions. DBD plasma actuators generate a wall-jet electronically by creating weakly ionized plasma, therefore their performance is affected by gas discharge properties, which, in turn, depend on the pressure and temperature at the actuator placement location. Characterization of actuators is initially performed in a laboratory chamber without external flow. The pressure and temperature at the actuator flight operation conditions need to be simultaneously set in the chamber. A simplified approach is desired. It is assumed that the plasma discharge depends only on the gas density, while other temperature effects are assumed to be negligible. Therefore, tests can be performed at room temperature with chamber pressure set to yield the same density as in operating flight conditions. The needed chamber pressures are shown for altitude flight of an air vehicle and for jet engines at sea-level takeoff and altitude cruise conditions. Atmospheric flight conditions are calculated from standard atmosphere with and without shock waves. The engine data was obtained from four generic engine models; 300-, 150-, and 50-passenger (PAX) aircraft engines, and a military jet-fighter engine. The static and total pressure, temperature, and density distributions along the engine were calculated for sea-level takeoff and for altitude cruise conditions. The corresponding chamber pressures needed to test the actuators were calculated. The results show that, to simulate engine component flows at in-flight conditions, plasma actuator should be tested over a wide range of pressures. For the four model engines the range is from 12.4 to 0.03 atm, depending on the placement of the actuator in the engine. For example, if a DBD plasma actuator is to be placed at the compressor exit of a 300 PAX engine, it has to be tested at 12.4 atm for takeoff, and 6 atm for cruise conditions. If it is to be placed at the low-pressure turbine, it has to be tested at 0.5 and 0.2 atm, respectively. These results have implications for the feasibility and design of DBD plasma actuators for jet engine flow control applications. In addition, the distributions of unit Reynolds number, Mach number, and velocity along the engine are provided. The engine models are non-proprietary and this information can be used for evaluation of other types of actuators and for other purposes.

Ashpis, David E.↗

Comprehensive process and environmental impact analysis of integrated DBD plasma steam methane reforming

Utilization of electricity generated from renewable sources to obtain hydrogen, H 2 , is of critical importance to decrease the overall carbon footprint. Here in this work, integration of a dielectric discharge barrier (DBD) plasma reactor to convert low calorific value gas, such as landfill gas or coal mine gas into hydrogen, into the existing steam methane reforming (SMR) technology was evaluated using process design considerations. In particular, a DBD-enhanced catalytic SMR reactor was modeled to operate at near atmospheric pressure and 500 °C sequentially with the conventional reformer to obtain ~ 65 kmol/hr H2 for distributed production. This allowed decreasing the size of the conventional reformer albeit at the increased overall electricity consumption. Calculated process economics showed that only at an electricity cost of less than $0.004/kWh does the hybrid DBD plasma process derived H 2 price become competitive with that of the conventional SMR. A Life Cycle Assessment framework was used to compare environmental impacts from the conventional SMR, hybrid DBD SMR and hybrid DBD SMR utilizing only onshore wind-derived electricity. Larger environmental impacts in the plasma reformer were obtained due to the use of electricity for the plasma reforming operation, which was modeled as coming from the typical U.S. grid mix. Utilizing only 100% wind-derived electricity provided certain environmental benefits, except for the ecotoxicity impact where the wind power scenario modeled here only reduced ecotoxicity impacts associated with electricity by 30%.

08 HYDROGEN↗

Shock Generation and Control Using DBD Plasma Actuators

This report is the final report of a NASA Phase I SBIR contract, with some revisions to remove company proprietary data. The Shock Boundary Layer Interaction (SBLI) phenomena in a supersonic inlet involve mutual interaction of oblique shocks with boundary layers, forcing the boundary layer to separate from the inlet wall. To improve the inlet efficiency, it is desired to prevent or delay shock-induced boundary layer separation. In this effort, Innovative Technology Applications Company (ITAC), LLC and the University of Notre Dame (UND) jointly investigated the use of dielectric-barrier-discharge (DBD) plasma actuators for control of SBLI in a supersonic inlet. The research investigated the potential for DBD plasma actuators to suppress flow separation caused by a shock in a turbulent boundary layer. The research involved both numerical and experimental investigations of plasma flow control for a few different SBLI configurations: (a) a 12 wedge flow test case at Mach 1.5 (numerical and experimental), (b) an impinging shock test case at Mach 1.5 using an airfoil as a shock generator (numerical and experimental), and (c) a Mach 2.0 nozzle flow case in a simulated 15 X 15 cm wind tunnel with a shock generator (numerical). Numerical studies were performed for all three test cases to examine the feasibility of plasma flow control concepts. These results were used to guide the wind tunnel experiments conducted on the Mach 1.5 12 degree wedge flow (case a) and the Mach 1.5 impinging shock test case (case b) which were at similar flow conditions as the corresponding numerical studies to obtain experimental evidence of plasma control effects for SBLI control. The experiments also generated data that were used in validating the numerical studies for the baseline cases (without plasma actuators). The experiments were conducted in a Mach 1.5 test section in the University of Notre Dame Hessert Laboratory. The simulation results from cases a and b indicated that multiple spanwise actuators in series and at a voltage of 75 kVp-p could fully suppress the flow separation downstream of the shock. The simulation results from case c showed that the streamwise plasma actuators are highly effective in creating pairs of counter-rotating vortices, much like the mechanical vortex generators, and could also potentially have beneficial effects for SBLI control. However, to achieve these effects, the positioning and the quantity of the DBD actuators used must be optimized. The wind tunnel experiments mapped the baseline flow with good agreement to the numerical simulations. The experimental results were conducted with spanwise actuators for cases a and b, but were limited by the inability to generate a sufficiently high voltage due to arcing in the wind-tunnel test-section. The static pressure in the tunnel was lower than the static pressure in an inlet at flight conditions, promoting arching and degrading the actuator performance.

Patel, Mehul P.↗

Progress Toward Accurate Measurements of Power Consumptions of DBD Plasma Actuators

The accurate measurement of power consumption by Dielectric Barrier Discharge (DBD) plasma actuators is a challenge due to the characteristics of the actuator current signal. Micro-discharges generate high-amplitude, high-frequency current spike transients superimposed on a low-amplitude, low-frequency current. We have used a high-speed digital oscilloscope to measure the actuator power consumption using the Shunt Resistor method and the Monitor Capacitor method. The measurements were performed simultaneously and compared to each other in a time-accurate manner. It was found that low signal-to-noise ratios of the oscilloscopes used, in combination with the high dynamic range of the current spikes, make the Shunt Resistor method inaccurate. An innovative, nonlinear signal compression circuit was applied to the actuator current signal and yielded excellent agreement between the two methods. The paper describes the issues and challenges associated with performing accurate power measurements. It provides insights into the two methods including new insight into the Lissajous curve of the Monitor Capacitor method. Extension to a broad range of parameters and further development of the compression hardware will be performed in future work.

Ashpis, David E.↗

Evaluating the carbon footprint of the integrated DBD‐plasma bi‐reforming unit via laboratory scale experiments and scaled‐up process modeling

Catalytic dielectric barrier discharge (DBD) plasma reactor experiments were performed in a tubular glass reactor with a 2 mm gap at 550°C to facilitate the reaction kinetics of steam added dry reforming or bireforming. The best specific energy input obtained was 11.2 eV/molecule feed at CO 2 :CH 4 :H 2 O of 4.5:1:4.5 ratio and gas hour space velocity (GHSV) = 432 h −1 . This value was used to design a conceptual process and assess the environmental impact of methane steam reforming-based H 2 production 18.4 kmol/h CO 2 emission processing into H 2 :CO = 2 syngas, with an emphasis on the carbon footprint.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dielectric Barrier Discharge (DBD) Plasma Actuators Thrust-Measurement Methodology Incorporating New Anti-Thrust Hypothesis

We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a large diameter, grounded, metal sleeve.

Ashpis, David E.↗

Thrust Measurement of Dielectric Barrier Discharge (DBD) Plasma Actuators: New Anti-Thrust Hypothesis, Frequency Sweeps Methodology, Humidity and Enclosure Effects

We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust, or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a grounded large-diameter metal sleeve. Strong dependence on humidity is also shown; the thrust significantly increased with decreasing humidity, e.g., 44 percent increase as relative humidity changed from 18 percent and dew point 33 degF to 50 percent and dew point of 57 degF.

Ashpis, David E.↗

Characterization of DBD Plasma Actuators Performance Without External Flow - Part I: Thrust-Voltage Quadratic Relationship in Logarithmic Space for Sinusoidal Excitation

Results of characterization of Dielectric Barrier Discharge (DBD) plasma actuators without external flow are presented. The results include aerodynamic and electric performance of the actuators without external flow for different geometrical parameters, dielectric materials and applied voltage level and wave form.

Dielectric Barrier Discharge↗

Characterization of DBD Plasma Actuators Performance without External Flow : Thrust-Voltage Quadratic Relationship in Logarithmic Space for Sinusoidal Excitation - Part I

We present results of thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators. We have used a test setup, measurement, and data processing methodology that we developed in prior work. The tests were conducted with High Density Polyethylene (HDPE) actuators of three thicknesses. The applied voltage driving the actuators was a pure sinusoidal waveform. The test setup was suspended actuators with a partial liquid interface. The tests were conducted at low ambient humidity. The thrust was measured with an analytical balance and the results were corrected for anti-thrust to isolate the plasma generated thrust. Applying this approach resulted in smooth and repeatable data. It also enabled curve fitting that yielded quadratic relations between the plasma thrust and voltage in log-log space at constant frequencies. The results contrast power law relationships developed in literature that appear to be a rough approximation over a limited voltage range.

Dielectric Barrier Discharge↗

Investigation of Reaction Pathways and Temperature Inhibition in Methane DBD Plasmas at the Princeton Collaborative Research Facility (PCRF)

The overarching goal of this research is to advance the fundamental understanding of plasma-driven chemical conversion of light hydrocarbons using dielectric barrier discharges (DBDs). Using methane (CH 4 ) as a model system, the primary focus is to elucidate the influence of DBD plasma properties and environmental temperature on CH 4 plasma chemistry by studying decomposition products of the gas effluent across a broad range of conditions using experimental instrumentation at the Princeton Collaborative Research Facility (PCRF) located at the Princeton Plasma Physics Laboratory (PPPL). The insights obtained from this study are expected to form the mechanistic foundation for the design and optimization of plasma-catalytic reactions of light hydrocarbons for practical applications such as the recycling of production flare gas by transforming the uncaptured waste into value-added resources at the source of extraction, presenting a sustainable solution to a longstanding environmental challenge.

03 NATURAL GAS↗

Bubbling Water–Treating DBD Plasma Device Optimization Using Experimental and Computational Methods

A dry air atmospheric pressure volume dielectric barrier discharge is employed to fix nitrogen in water. Producing nitrate for use as nitrogen fertilizer is the primary motivation. A 0D chemistry model is developed and informed by the electrical, and geometric characteristics of the device and the plasma gas temperature. Modeled ozone and nitrate densities are compared to those measured experimentally in the plasma effluent and treated liquid for a range of gas temperatures. Modeled and measured ozone densities are in good agreement; however, the model lacks the liquid chemistry to properly represent the measured nitrate density. A gas temperature-based shift from ozone to NO x producing regimes is observed in both experiment and model, and the reactions responsible are evaluated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-Oxidative Ethane Dehydrogenation in a Packed-Bed DBD Plasma Reactor

Abstract Plasma-assisted conversion of ethane (C 2 H 6 ) can produce value-added chemical building blocks using green electricity. Here we employ a simple packed-bed coaxial dielectric barrier discharge (DBD) reactor to convert C 2 H 6 at mild operating conditions unattainable by conventional thermocatalysis. Ethylene (C 2 H 4 ), acetylene (C 2 H 2 ), and methane (CH 4 ) are the main products along with small fractions of C 3 and C 4 hydrocarbons. Interestingly, the C 2 H 4 selectivity is primarily correlated to C 2 H 6 conversion, dominated by electron dissociation and recombination reactions irrespective of the dielectric properties of the packed bed material (SiO 2 , Al 2 O 3 , ZrO 2 , TiO 2 , and BaTiO 3 ), packing material size, supplied power, and C 2 H 6 concentration. While a distortion of the electric field and discharge propagation results in varying dissipated power as materials change, the C 2 H 4 energy yield remains constant. The particle size appears to affect conversion mainly due to pressure alterations. Pd/SiO 2 catalyst can change the selectivity, favoring saturated species by expending hydrogen.

Engineering↗

Comparisons of Force Measurement Methods for DBD Plasma Actuators in Quiescent Air

We have performed measurements of the force induced by both single (one electrode insulated) and double (both electrodes insulated) dielectric barrier discharge plasma actuators in quiescent air. We have shown that, for single barrier actuators with cylindrical exposed electrodes, as the electrode diameter decrease the force efficiencies increase much faster than a previously reported linear trend. This behavior has been experimentally verified using two different measurement techniques: stagnation probe measurements of the induced flow velocity and direct measurement of the force using an electronic balance. Actuators with rectangular cross-section exposed electrodes do not show the same rapid increase at small thicknesses. We have also shown that the induced force is independent of the material used for the exposed electrode. The same techniques have shown that the induced force of a double barrier actuator increases with decreasing narrow electrode diameter.

Hoskinson, Alan R.↗

Force Measurements of Single and Double Barrier DBD Plasma Actuators in Quiescent Air

We have performed measurements of the force induced by both single (one electrode insulated) and double (both electrodes insulated) dielectric barrier discharge plasma actuators in quiescent air. We have shown that, for single barrier actuators, as the electrode diameter decreased below those values previously studied the induced Force increases exponentially rather than linearly. This behavior has been experimentally verified using two different measurement techniques: stagnation probe measurements of the induced flow velocity and direct measurement of the force using an electronic balance. In addition, we have shown the the induced force is independent of the material used for the exposed electrode. The same techniques have shown that the induced force of a double barrier actuator increases with decreasing narrow electrode diameter.

Hoskinson, Alan R.↗

Simulation Tool for Dielectric Barrier Discharge Plasma Actuators

Traditional approaches for active flow separation control using dielectric barrier discharge (DBD) plasma actuators are limited to relatively low speed flows and atmospheric conditions. This results in low feasibility of the DBDs for aerospace applications. For active flow control at turbine blades, fixed wings, and rotary wings and on hypersonic vehicles, DBD plasma actuators must perform at a wide range of conditions, including rarified flows and combustion mixtures. An efficient, comprehensive, physically based DBD simulation tool can optimize DBD plasma actuators for different operation conditions. Researchers are developing a DBD plasma actuator simulation tool for a wide range of ambient gas pressures. The tool will treat DBD using either kinetic, fluid, or hybrid models, depending on the DBD operational condition.

Likhanskii, Alexander↗

DBD plasma-assisted ethanol steam reforming for green H 2 production: Process optimization through response surface methodology (RSM)

Herein this work investigates ethanol steam reforming (ESR) to produce hydrogen (H 2 ) in a dielectric barrier discharge (DBD) plasma reactor. A five-level, three-factor experiment design was performed using a response surface methodology (RSM) to evaluate the combined effects of the three process parameters, including discharge power, total flow rate, and ethanol-to-water (EtOH/H 2 O) molar ratio on the plasma-assisted ESR reaction. Quadratic regression models were employed in RSM to fit the experimental results and present the correlation between process parameters and targeted responses (EtOH conversion, H 2 yield, H 2 selectivity, and specific energy requirement (SER) for H 2 production). The results suggested that the EtOH/H 2 O molar ratio is considered to have the most significant effect on the EtOH conversion and H 2 , H 2 selectivity, while the total flow rate is the most significant parameter determining SER for H 2 production. Process optimization demonstrated the optimal process conditions, including a discharge power of 55.9 W, a total flow rate of 26.7 ml/min, and an EtOH/H 2 O molar ratio equal to 0.34. A validation test was performed and confirmed the feasibility of the optimization process.

08 HYDROGEN↗

Contrasting the characteristics of atmospheric pressure plasma jets operated with single and double dielectric material: physicochemical characteristics and application to bacterial killing

Abstract This study reports an experimental comparison of two types of atmospheric pressure plasma jets in terms of their fundamental plasma characteristics and efficacy in bacterial sterilization. The plasma jets are fabricated by inserting a high voltage electrode inside a one-end closed (double DBD plasma jet) or both ends open (single DBD plasma jet) quartz tubes which are further enclosed inside a second quartz tube containing a ground electrode. Both plasma jets are operated in contact with water surface by using a unipolar pulsed DC power supply with helium as the working gas. Results from electrical and time-resolved imaging show that the single DBD configuration induces 3–4 times higher accumulation of charges onto the water surface with significantly faster propagation of plasma bullets. These results are accompanied by the higher discharge intensity as well as stronger emissions from short-lived reactive species which were analyzed through optical emission spectroscopy at the plasma-water interface. The rotational temperature for the single DBD configuration was observed to be higher making it unsafe for direct treatments of sensitive biological targets. These characteristics of the single DBD configuration result in the production of more than two times higher concentration of H 2 O 2 in plasma activated water. Shielding of the HV electrode reduces the plasma potential which in turn reduces the electric field & electron energy at the plasma-water interface. The reduced electric field for the double DBD configuration was lower by ≈463 Td than the single DBD configuration. The bactericidal efficacy of the two configurations of the plasma jets were tested against Escherichia coli , a well studied Gram-negative bacterium that can be commensal and pathogenic in human body. Our results demonstrate that although single DBD plasma jet result in stronger antibacterial effects, the double DBD configuration could be safer.

Physics↗