Search NASA⌕ Search

SEARCH · Search NASA

Results for “DC Arc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

In situ studies of a molten metal anode ablation in a nearly atmospheric pressure DC arc

A DC arc with a meltable metal anode in a near-atmospheric pressure hydrocarbon gas is an emerging method for producing single-walled carbon nanotubes (SWCNTs). In these systems, evaporation of the molten metal anode determines the formation of catalyst seed particles needed for SWCNT growth, and therefore, should be monitored, controlled, and optimized. Evaluating the anode ablation rate by weighing the anode before and after a synthesis run is unfeasible due to anode carburization in the hydrocarbon atmosphere. To overcome this, we implemented a high-speed, 2D, 2-color pyrometry for reliable temperature measurements of the molten anode in a DC arc. The obtained temperature fields were used to calculate the anode ablation rates. Results showed the importance of resolving the arc and molten pool dynamics, as well as addressing the issue of reflections. Furthermore, significant changes in ablation rates were revealed upon addition of CH 4 , which must be considered when scaling up the production of SWCNTs.

Marangoni↗

Nature of convection-stabilized dc arcs in dual-flow nozzle geometry. I - The cold flow field and dc arc characteristics. II - Optical diagnostics and theory

Steady-state low-current air arcs in a dual-flow nozzle system are studied experimentally. The cold flow field with no arc is investigated using a 12.7-mm diameter dual-flow nozzle in a steady-flow facility. Mach number and mass flux distributions are determined for various nozzle-pressure ratios and nozzle-gap spacing. It is found that the shock waves in the converging-diverging nozzles result in a decrease in overal resistance by about 15 percent. Also, Schlieren and differential interferometry techniques are used to visualize the density gradients within the arc plasma and thermal mantle. Both optical techniques reveal a laminar arc structure for a reservoir pressure of 1 atm at various current levels. Experimentally determined axial static pressure and cold-flow mass flux rate distributions and a channel-flow model with constant arc temperatre are used to solve the energy integral for the arc radius as a function of axial distance. The arc electric field strength, voltage, resistance, and power are determined with Ohm's law and the total heat transfer is related to arc power.

Serbetci, Ilter↗

Methods for Evaluating DC Arc Incident Energy in PV Systems: Preprint

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This paper focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of DC arc flash incident energy evaluation. Because of the fast proliferation of PV systems and the lack of formal equivalent calculation guidelines such as IEEE 1584 for AC systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This paper discusses the behavior of PV systems under arc conditions and presents the results of available methods to estimate the dc arc flash incident energy. This paper provides a comparative analysis of a proposed arc-flash incident energy calculation method against different laboratory tests including those performed by NREL. Detailed explanations are provided regarding the effect of PV module I-V and P-V curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

Nuclear light bulb propellant heating simulation using a tungsten/argon aerosol and radiation from a dc arc surrounded by a segmented mirror cavity

Experiments were conducted to simulate radiant heating of the propellant stream of a nuclear light bulb engine to obtain high bulk exit temperatures in the flowing simulated propellant stream by absorption of large fractions of the incident thermal radiation. A high-power, vortex-stabilized dc arc within an uncooled fused silica tube was used as the radiant energy source. It was surrounded by a mirror system to increase the radiation incident on the simulated propellant. The 12.7-cm-long by 2.3-cm-wide, diverging-duct test section had a transparent front wall and a reflecting rear wall. The central stream of seeded gas, a tungsten-particle/argon aerosol, had unseeded argon buffer layers on both sides to prevent coating of the duct walls. Arc operating times were approximately 0.5 sec with power levels up to 780 kW. Bulk exit temperatures were measured using a calorimeter downstream of the duct. The maximum simulated propellant bulk exit temperature obtained was 4515 K, compared with 3860 K in previous tests, 3300 to 3700 K expected in in-reactor tests in the Nuclear Furnace, and 6660 K in the reference nuclear light bulb engine. The maximum temperature in these tests was limited primarily by the amount of radiation incident on the test section (determined by the arc operating characteristics and the effectiveness of the mirror cavity).

Klein, J. F.↗

Nitriding of titanium and its alloys by N2, NH3 or mixtures of N2 + H2 in a dc arc plasma at low pressures ( or = to torr)

The dc glow discharges in different gas mixtures of Ar + N2, Ar + NH3 or Ar + N2 + H2 result in the surface nitriding of Ti metal and its alloy (Ti6Al4V). Various gas mixtures were used in order to establish the main active species governing the nitriding process, i.e., N, N2, NH, or NH2 as excited or ionized particles. The dc discharge was sampled and analyzed by quadruple mass spectrometry (QPMS) and optical emission spectroscopy (OES), and the nitrided samples were analyzed by scanning electron microscopy (SEM) with an EDAX attachment, microhardness, and Fourier transform infrared reflectance spectrometry (FTIR). It was found that the excited and ionized nitrogen and hydrogen atoms are the main species responsible for the nitriding process in a dc glow discharge.

Avni, R.↗

Experimental investigation of megawatt dc arc heating of nitrogen

Four types of arc heaters, each with the capability of providing arc power levels in excess of 1 megawatt in nitrogen, were tested over a range of power levels and nitrogen flow rates to determine their value as heaters for hypersonic tunnels. The data derived should be useful in the design of high energy heaters for various industrial processes.

Boldman, D. R.↗

The dc arc characteristics in subsonic orifice nozzle flow

The cold air flow field for a 1/27 cm orifice nozzle was determined for subsonic flow velocities. In addition, d.c. arc voltage, current, and diameter measurements were made for a range of velocities and arc gaps. Average voltage gradients increased rapidly as an arc extinguishing velocity was approached. Measured values of current and diameter were used as an input for relaxation solution of an energy balance equation to compute radial temperature profiles. Calculated arc voltage gradients compare favorably with measured average voltage gradients.

Nagamatsu, H. T.↗

DC Arc-Flash Safety for 1,500VDC: Methodology, Verification, and Codifying

This project aimed to address critical gaps in understanding arc flash phenomena in commercially operating photovoltaic (PV) plants. Motivated by the global growth of PV systems and the associated safety risks, the research sought to enhance knowledge, improve incident energy prediction models, and contribute to the overall safety and reliability of PV installations.

14 SOLAR ENERGY↗

Arcing on dc power systems

Unexpected and undesirable arcing on dc power systems can produce hazardous situations aboard space flights. The potential for fire and shock might exist in a situation where there is a broken conductor, a loose power connection, or a break in the insulation of the power cable. Such arcing has been found to be reproducible in a laboratory environment. Arcing tests show that the phenomena can last for several seconds and yet be undetectable by present protection schemes used in classical power relaying and remote power controller applications. This paper characterizes the arcing phenomena and suggests future research that is needed.

Moores, Greg↗

Algorithm For Detecting dc Series Arcs

Algorithm developed for use in automatic detection of dc series arcs in power cables, cable terminations, and junction boxes. (Sometimes detects arcs inside electrical loads.) System in which algorithm utilized is one receiving power from microprocessor-based remote power controller that includes load-current sensor. Algorithm analyzes digitized load-current readings for fluctuations characteristic of dc series arcs.

Moores, Greg L.↗