Search NASA⌕ Search

SEARCH · Search NASA

Results for “DC arc flash”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

DC Arc-Flash Safety for 1,500VDC: Methodology, Verification, and Codifying

This project aimed to address critical gaps in understanding arc flash phenomena in commercially operating photovoltaic (PV) plants. Motivated by the global growth of PV systems and the associated safety risks, the research sought to enhance knowledge, improve incident energy prediction models, and contribute to the overall safety and reliability of PV installations.

14 SOLAR ENERGY↗

Methods for Evaluating DC Arc Incident Energy in PV Systems: Preprint

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This paper focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of DC arc flash incident energy evaluation. Because of the fast proliferation of PV systems and the lack of formal equivalent calculation guidelines such as IEEE 1584 for AC systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This paper discusses the behavior of PV systems under arc conditions and presents the results of available methods to estimate the dc arc flash incident energy. This paper provides a comparative analysis of a proposed arc-flash incident energy calculation method against different laboratory tests including those performed by NREL. Detailed explanations are provided regarding the effect of PV module I-V and P-V curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of DC Arc-Flash Incident Energy in Large-Scale Photovoltaic Plants: A Basis for Standardization

The deployment of high-power dc equipment is increasing in solar photovoltaic (PV) plants, but very few studies have quantified dc arc-flash risks. Currently, PV plant owners and operators rely on theoretical, simplified models, such as those in NFPA-70E and other publications, for the assessment of risk associated with dc arc-flash. Here, this article presents an overview of arc-flash risks in a PV system based on a series of field experiments based on IEEE-1584 in two large-scale ground-mounted PV plants. The experiments include various high-power dc equipment of a PV plant, such as central inverters, combiner boxes, recombiner boxes, string inverters, and multiple configurations of electrodes in a 20-in calibration cube. The study reveals that none of the available dc arc-flash models are applicable for a PV plant. This work is an important first step toward developing an improved model that more accurately assesses dc arc-flash risk in a PV plant.

14 SOLAR ENERGY↗

Evaluating the Incident Energy of Arcs in Photovoltaic DC Systems: Comparison Between Calculated and Experimental Data

Solar Photovoltaic (PV) systems have permeated the energy generation world at a very high rate, some of the safety codes and standards are still lagging in accurately assessing the hazards and risks associated with PV array arcing energies. Safety professionals and maintenance workers using NFPA 70E have utilized the Doan, Stokes & Oppenlander or Enrique models, meant to determine arc energies in DC power systems using the maximum power method. These methods may lead to an overestimate of energy available in PV systems during a fault. Since PV modules/arrays are non-linear, current limited DC devices, some of these calculation methods may not accurately predict fault energy. This paper will validate current arc energy models for PV systems by comparing experimental and calculated data. Additionally, this data will help modify the current NFPA 70E models related to smaller solar arrays. Understanding where the real safety threshold for DC arc flash in PV systems exists will help maintenance and safety professionals better prepare for a variety of work related activities. This paper will analyze real arc data taken for PV systems <1000VDC and <60amps and compare this to the calculated incident energy models, to include 70E. Thus, using these comparisons, it may be possible to reduce the safety hazard severity and thus relax the PPE requirements for installation and maintenance crews.

14 SOLAR ENERGY↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

Solar/Photovoltaic DC Systems: Information for Electrical Workers and Firefighters

Solar photovoltaic (PV) systems are common and continue to gain popularity. This article helps electrical workers and firefighters understand basic operating principles and hazards of PV dc arrays. The effects of solar radiation and temperature on power output are discussed including; PV-module testing standards; methods for calculating the number of modules in a PV string; some National Electrical Code (NEC) guidelines that are aimed toward improving array safety; dc-array commissioning, periodic maintenance, and testing; arc-flash-hazard potential ways firefighters can work safely around PV arrays; potential risks posed by moonlight and other light sources; some unique dc-system hazards. We also present statistics on PV dc-array electrical incidents and injuries.

14 SOLAR ENERGY↗

SiC-Based Wireless Power Transformation for Data Centers & Medium Voltage Applications

Data centers have grown in physical size and their electrical power consumption has grown to levels of several 100kW and approaching 1 GW in large installations. The low voltage electrical distribution inside of Data Centers consists of several conversion stages and a lot of wiring to bring the power from medium voltage (MV) levels outside of the building to the low voltage levels that the servers and racks require. Energy losses during distribution and conversion and high incident arc flash energy levels at the point of use are significant. The electrical distribution system is complex and costly.

24 POWER TRANSMISSION AND DISTRIBUTION↗