Search NASA⌕ Search

SEARCH · Search NASA

Results for “DC incident energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Methods for Evaluating DC Arc Incident Energy in PV Systems: Preprint

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This paper focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of DC arc flash incident energy evaluation. Because of the fast proliferation of PV systems and the lack of formal equivalent calculation guidelines such as IEEE 1584 for AC systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This paper discusses the behavior of PV systems under arc conditions and presents the results of available methods to estimate the dc arc flash incident energy. This paper provides a comparative analysis of a proposed arc-flash incident energy calculation method against different laboratory tests including those performed by NREL. Detailed explanations are provided regarding the effect of PV module I-V and P-V curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

Measurement of DC Arc-Flash Incident Energy in Large-Scale Photovoltaic Plants: A Basis for Standardization

The deployment of high-power dc equipment is increasing in solar photovoltaic (PV) plants, but very few studies have quantified dc arc-flash risks. Currently, PV plant owners and operators rely on theoretical, simplified models, such as those in NFPA-70E and other publications, for the assessment of risk associated with dc arc-flash. Here, this article presents an overview of arc-flash risks in a PV system based on a series of field experiments based on IEEE-1584 in two large-scale ground-mounted PV plants. The experiments include various high-power dc equipment of a PV plant, such as central inverters, combiner boxes, recombiner boxes, string inverters, and multiple configurations of electrodes in a 20-in calibration cube. The study reveals that none of the available dc arc-flash models are applicable for a PV plant. This work is an important first step toward developing an improved model that more accurately assesses dc arc-flash risk in a PV plant.

14 SOLAR ENERGY↗

Evaluating the Incident Energy of Arcs in Photovoltaic DC Systems: Comparison Between Calculated and Experimental Data

Solar Photovoltaic (PV) systems have permeated the energy generation world at a very high rate, some of the safety codes and standards are still lagging in accurately assessing the hazards and risks associated with PV array arcing energies. Safety professionals and maintenance workers using NFPA 70E have utilized the Doan, Stokes & Oppenlander or Enrique models, meant to determine arc energies in DC power systems using the maximum power method. These methods may lead to an overestimate of energy available in PV systems during a fault. Since PV modules/arrays are non-linear, current limited DC devices, some of these calculation methods may not accurately predict fault energy. This paper will validate current arc energy models for PV systems by comparing experimental and calculated data. Additionally, this data will help modify the current NFPA 70E models related to smaller solar arrays. Understanding where the real safety threshold for DC arc flash in PV systems exists will help maintenance and safety professionals better prepare for a variety of work related activities. This paper will analyze real arc data taken for PV systems <1000VDC and <60amps and compare this to the calculated incident energy models, to include 70E. Thus, using these comparisons, it may be possible to reduce the safety hazard severity and thus relax the PPE requirements for installation and maintenance crews.

14 SOLAR ENERGY↗

DC Arc-Flash Safety for 1,500VDC: Methodology, Verification, and Codifying

This project aimed to address critical gaps in understanding arc flash phenomena in commercially operating photovoltaic (PV) plants. Motivated by the global growth of PV systems and the associated safety risks, the research sought to enhance knowledge, improve incident energy prediction models, and contribute to the overall safety and reliability of PV installations.

14 SOLAR ENERGY↗

Microscopic study of the fusion reactions 40,48 Ca+ 78 Ni and the effect of the tensor force

In this work, we provide a microscopic description of the fusion reactions between 40,48 Ca and 78 Ni. The internuclear potentials are obtained using the density-constrained (DC) time-dependent Hartree-Fock (TDHF) approach and fusion cross sections are calculated via the incoming wave boundary condition method. By performing DC-TDHF calculations at several selected incident energies, the internuclear potentials for both systems are obtained and the energy-dependence of fusion barrier are revealed. The influence of tensor force on internuclear potentials of 48 Ca+ 78 Ni is more obvious than those of 40 Ca+ 78 Ni. By comparing the calculated fusion cross sections between 40 Ca+ 78 Ni and 48 Ca+ 78 Ni, an interesting enhancement of subbarrier fusion cross sections for the former system is found, which can be explained by the narrow width of internuclear potential for 40 Ca+ 78 Ni while the barrier heights and positions are very close to each other. The tensor force suppresses the subbarrier fusion cross sections of both two systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear light bulb propellant heating simulation using a tungsten/argon aerosol and radiation from a dc arc surrounded by a segmented mirror cavity

Experiments were conducted to simulate radiant heating of the propellant stream of a nuclear light bulb engine to obtain high bulk exit temperatures in the flowing simulated propellant stream by absorption of large fractions of the incident thermal radiation. A high-power, vortex-stabilized dc arc within an uncooled fused silica tube was used as the radiant energy source. It was surrounded by a mirror system to increase the radiation incident on the simulated propellant. The 12.7-cm-long by 2.3-cm-wide, diverging-duct test section had a transparent front wall and a reflecting rear wall. The central stream of seeded gas, a tungsten-particle/argon aerosol, had unseeded argon buffer layers on both sides to prevent coating of the duct walls. Arc operating times were approximately 0.5 sec with power levels up to 780 kW. Bulk exit temperatures were measured using a calorimeter downstream of the duct. The maximum simulated propellant bulk exit temperature obtained was 4515 K, compared with 3860 K in previous tests, 3300 to 3700 K expected in in-reactor tests in the Nuclear Furnace, and 6660 K in the reference nuclear light bulb engine. The maximum temperature in these tests was limited primarily by the amount of radiation incident on the test section (determined by the arc operating characteristics and the effectiveness of the mirror cavity).

Klein, J. F.↗

Development of a Tunable Electromechanical Acoustic Liner for Engine Nacelles

This report describes the development of a tunable electromechanical Helmholtz resonator (EMHR) for engine nacelles using smart materials technology. This effort addresses both near-term and long-term goals for tunable electromechanical acoustic liner technology for the Quiet Aircraft Technology (QAT) Program. Analytical models, i.e. lumped element model (LEM) and transfer matrix (TM) representation of the EMHR, have been developed to predict the acoustic behavior of the EMHR. The models have been implemented in a MATLAB program and used to compare with measurement results. Moreover, the prediction performance of models is further improved with the aid of parameter extraction of the piezoelectric backplate. The EMHR has been experimentally investigated using standard two-microphone method (TMM). The measurement results validated both the LEM and TM models of the EMHR. Good agreement between predicted and measured impedance is obtained. Short- and open circuit loads define the limits of the tuning range using resistive and capacitive loads. There is approximately a 9% tuning limit under these conditions for the non-optimized resonator configuration studied. Inductive shunt loads result in a 3 degree-of-freedom DOF) system and an enhanced tuning range of over 20% that is not restricted by the short- and open-circuit limits. Damping coefficient ' measurements for piezoelectric backplates in a vacuum chamber are also performed and indicate that the damping is dominated by the structural damping losses, such as compliant boundaries, and other intrinsic loss mechanisms. Based on models of the EMHR, a Pareto optimization design of the EMHR has been performed for the EMHR with non-inductive loads. The EMHR with non-inductive loads is a 2DOF system with two resonant fiequencies. The tuning ranges of the two resonant frequencies of the EMHR with non-inductive loads cannot be optimized simultaneously; a trade-off (i.e., a Pareto solution) must be reached. The Pareto solution provides the information for a designer that shows how design trade-offs can be used to satisfy specific design requirements. The optimization design of the EMHR with inductive loads aims at optimal tuning of these three resonant fiequencies. The results indicate that it is possible to keep the acoustic reactance of the resonator close to a constant over a given frequency range. An effort to mimic the second layer of the NASA 2DOF liner using a piezoelectric composite diaphragm has been made. The optimal acoustic reactance of the second layer of the NASA 2DOF liner is achieved using a thin PVDF composite diaphragm, but matching the acoustic resistance requires further investigation. Acoustic energy harvesting is achieved by connecting the EMHR to an energy reclamation circuit that converts the ac voltage signal across the piezoceramic to a conditioned dc signal. Energy harvesting experiment yields 16 m W continuous power for an incident SPL of 153 dB. Such a level is sufficient to power a variety of low power electronic devices. Finally, technology transfer has been achieved by converting the original NASA ZKTL FORTRAN code to a MATLAB code while incorporating the models of the EMHR. Initial studies indicate that the EMHR is a promising technology that may enable lowpower, light weight, tunable engine nacelle liners. This technology, however, is very immature, and additional developments are required. Recommendations for future work include testing of sample EMHR liner designs in NASA Langley s normal incidence dual-waveguide and the grazing-incidence flow facility to evaluating both the impedance characteristics as well as the energy reclamation abilities. Additional design work is required for more complex tuning circuits with greater performance. Poor electromechanical coupling limited the electromechanical tuning capabilities of the proof of concept EMHR. Different materials than those studies and perhaps novel composite material systems may dramatically improvehe electromechanical coupling. Such improvements are essential to improved mimicking of existing double layer liners.

Liu, Fei↗

Record performance in intrinsic, impurity-free lateral diamond photoconductive semiconductor switches

Photoconductive semiconductor switches (PCSSs) are fabricated on type IIa diamond substrates with varying boron and nitrogen impurity levels (<10 14 –10 16 cm –3 ). The photoresponse of lateral PCSS is reported over the incident laser wavelength range (212–240 nm), energy per pulse (5–65 μJ), and DC bias (–1.2 to +1.2 kV). The PCSS device with the lowest boron and nitrogen impurity concentration achieves the highest normalized responsivity of 9.1 × 10 –8 A-cm/W-V, peak photocurrent of 8.0 A, and on/off ratio of 2.3 × 10 11 at a DC bias of +1.2 kV with the potential for even higher currents at increased DC bias. All PCSS display fast rise times (<3 ns), limited by the laser's rise time. However, photoresponse measurements reveal that higher impurity levels reduce the photocurrent and decrease the on/off ratio. Furthermore, these results highlight the performance advantages of using low background concentration type IIa diamond substrates for PCSS fabrication and present a promising route toward advanced high-power, high-speed diamond-based switches.

42 ENGINEERING↗

Solar/Photovoltaic DC Systems: Information for Electrical Workers and Firefighters

Solar photovoltaic (PV) systems are common and continue to gain popularity. This article helps electrical workers and firefighters understand basic operating principles and hazards of PV dc arrays. The effects of solar radiation and temperature on power output are discussed including; PV-module testing standards; methods for calculating the number of modules in a PV string; some National Electrical Code (NEC) guidelines that are aimed toward improving array safety; dc-array commissioning, periodic maintenance, and testing; arc-flash-hazard potential ways firefighters can work safely around PV arrays; potential risks posed by moonlight and other light sources; some unique dc-system hazards. We also present statistics on PV dc-array electrical incidents and injuries.

14 SOLAR ENERGY↗

Artificial ground reflector size and position effects on energy yield and economics of single‐axis‐tracked bifacial photovoltaics

Abstract Artificial ground reflectors improve bifacial energy yield by increasing both front and rear‐incident irradiance. Studies have demonstrated an increase in energy yield due to the addition of artificial reflectors; however, they have not addressed the effect of varying reflector dimensions and placement on system performance and the impact of these parameters on the reflectors' financial viability. We studied the effect of high albedo (70% reflective) artificial reflectors on single‐axis‐tracked bifacial photovoltaic systems through ray‐trace modeling and field measurements. In the field, we tested a range of reflector configurations by varying reflector size and placement and demonstrated that reflectors increased daily energy yield up to 6.2% relative to natural albedo for PERC modules. To confirm the accuracy of our model, we compared modeled and measured power and found a root mean square error (RMSE) of 5.4% on an hourly basis. We modeled a typical meteorological year in Golden, Colorado, to demonstrate the effects of artificial reflectors under a wide range of operating conditions. Seventy percent reflective material can increase total incident irradiance by 1.9%–8.6% and total energy yield by 0.9%–4.5% annually after clipping is considered with a DC–AC ratio of 1.2. Clipping has a significant effect on reflector impact and must be included when assessing reflector viability because it reduces reflector energy gain. We calculated a maximum viable cost for these improvements of up to $2.50–4.60/m 2 , including both material and installation, in Golden. We expanded our analysis to cover a latitude range of 32–48°N and demonstrated that higher‐latitude installations with lower energy yield and higher diffuse irradiance content can support higher reflector costs. In both modeling and field tests, and for all locations, the ideal placement of the reflectors was found to be directly underneath the module due to the optimized rear irradiance increase.

14 SOLAR ENERGY↗

Preliminary comparison of material charging properties using single-energy and multienergy electron beams

Results of tests designed to compare the charging properties of spacecraft material under a monoenergetic beam and under a continuously distributed beam are summarized. In the test setup the electron source was mounted in the top of a cylindrical vacuum chamber. A sheet of 5-mil-thick Kapton was placed on an insulated metal substrate at the bottom of the vacuum chamber. The dc current arriving on the substrate was measured and a field meter measured the potential of the test sample. A retarding potential analyzer measured the energy spectrum of the incident electron beam. With the monoenergetic beam, the sample charged to 12 kV and electrical discharges occurred. With the multi-energy spectra the samples charged to only 6 kV and 4 kV, and no discharger were observed. In these experiments, no effort was made to duplicate the spectra occurring in space. The tests were intended to simply to compare spacecraft material charging properties using monoenergetic and continuous multi-energy beams.

Adamo, R. C.↗

Design and Analysis of an Integral MPPT Control Law for Wave Energy Conversion Systems

In this paper, we propose an integral-based maximum power point tracking (MPPT) algorithm for point absorber wave energy conversion (WEC) systems. A permanent magnet synchronous generator (PMSG) is coupled to the point absorber and its drive implements the proposed MPPT control. While the rotating frame of reference of the PMSG implements power control, the slower mechanical frequency of the incident waves are processed with an additional transformation that yields another set of dc dynamics. The computed dc power in the new reference frame, which is focused on slow wave dynamics, is input to the MPPT control law that tunes the emulated resistance of the machine drive to extract peak power from the wave absorber device. We derive a stability condition for the proposed controller and validate our control design on a simulated 10kW system.

wave energy, maximum power point tracking (MPPT), ↗

A transportronic solution to the problem of interorbital transportation

An all-electronic transportation system described by the term 'transportronics' is examined as a means of solving the current problem of the high cost of transporting material from low-Earth orbit (LEO) to geostationary orbit (GEO). In this transportation system, low cost electric energy at the surface of the Earth is efficiently converted into microwave power which is then efficiently formed into a narrow beam which is kept incident upon the orbital transfer vehicles (OTV's) by electronic tracking. The incident beam is efficiently captured and converted into DC power by a device which has a very high ratio of DC power output to its mass. Because the mass of the electric thruster is also low, the resulting acceleration is unprecedented for electric-propelled vehicles. However, the performance of the system in terms of transit times from LEO to GEO is penalized by the short time of contact between the beam and the vehicle in low-Earth orbits. This makes it necessary to place the Earth based transmitters and the vehicles in the equatorial plane thus introducing many geopolitical factors. Technically, however, such a system as described in the report may out-perform any other approach to transportation in the LEO to GEO regime. The report describes and analyzes all portions of the beamed microwave power transmission system in considerable detail. An economic analysis of the operating and capital costs is made with the aid of a reference system capable of placing about 130,000 kilograms of payload into GEO each year. More mature states of the system are then examined, to a level in which 60,000 metric tons per year could be placed into GEO.

Brown, William C.↗

SiC-Based Wireless Power Transformation for Data Centers & Medium Voltage Applications

Data centers have grown in physical size and their electrical power consumption has grown to levels of several 100kW and approaching 1 GW in large installations. The low voltage electrical distribution inside of Data Centers consists of several conversion stages and a lot of wiring to bring the power from medium voltage (MV) levels outside of the building to the low voltage levels that the servers and racks require. Energy losses during distribution and conversion and high incident arc flash energy levels at the point of use are significant. The electrical distribution system is complex and costly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HZETRN: neutron and proton production in quasi-elastic scattering of GCR heavy-ions

The development of transport models for radiation shielding design and evaluation has provided a series of deterministic computer codes that describe galactic cosmic radiation (GCR), solar particle events, and experimental beams at particle accelerators. These codes continue to be modified to accommodate new theory and improvements to the particle interaction database (Cucinotta et al., 1994, NASA Technical Paper 3472, US Government Printing Office, Washington DC). The solution employed by the heavy-ion transport code HZETRN was derived with the assumption that nuclear fragments are emitted with the same velocity as the incident ion through velocity conserving nuclear interactions. This paper presents a version of the HZETRN transport code that provides a more realistic distribution of the energy of protons and neutrons emitted from GCR interactions in shields. This study shows that the expected GCR dose equivalent is lower than previously calculated for water shields that are less than 110 g cm-2 thick. Calculations of neutron energy spectra in low Earth orbit indicate substantial contributions from relativistic neutrons. c2001 Elsevier Science Ltd. All rights reseved.

NASA Center LaRC↗

Phase composition of polycrystalline HfNx (0.45 ≤ x ≤ 1.60) and effects of low-energy ion irradiation on microstructure, texture, and physical properties

We have investigated the phase composition of HfNx as a function of x and the effects of low-energy ion irradiation on the microstructure and physical properties of polycrystalline layers grown on SiO2 at 350 °C by ultrahigh vacuum reactive dc magnetron sputtering of Hf in mixed N2/Ar discharges. X-ray diffraction and Rutherford backscattering spectrometry results show that the phases obtained in polycrystalline HfNx layers with increasing x are hcp-structure α-Hf:N (x ≲ 0.6); multiphase mixtures consisting of α-Hf, NaCl-structure δ-HfN, rhombohedral ɛ-Hf3N2, and/or ζ-Hf4N3 (0.6 ≲ x ≲ 0.9); δ-HfN single phase (0.9 ≲ x ≲ 1.3); and mixtures of δ-HfN and higher nitrides (x ≳ 1.3). HfNx layers with 0.9 ≲ x ≲ 1.2 grown under mild ion irradiation (incident ion energy Ei ≃ 7 eV and ion-to-Hf flux ratios Ji/JHf = 1−3) are underdense with mixed orientation, low in-plane stress, and rough surface morphology due to limited adatom mobilities resulting in kinetic roughening and atomic shadowing during film growth. However, the use of intense ion irradiation (Ei = 25 eV and Ji/JHf = 4−20) results in HfNx layers, which are fully dense with strongly 111-oriented texture, compressive in-plane stress, and smooth surfaces due to ion irradiation enhanced adatom surface mobilities. In addition, the latter films have lower resistivity and higher hardness. For stoichiometric δ-HfN layers, ρ decreases from 69.7 to 35.2 μΩ cm and H increases from 22.1 to 27.4 GPa, with increasing ion-irradiation intensity. However, for HfNx layers with 1.2 ≲ x ≲ 1.6, the correspondingly higher steady state atomic N surface coverages during deposition alter growth kinetics in favor of 001 texture with a fully dense structure and compressive in-plane stress.

Materials Science↗

A Safe Response to Renewable Energy Hazards

The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗