Search NASA⌕ Search

SEARCH · Search NASA

Results for “DC-DC power converters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Duty-Cycle Predictive Control of Quasi-Z-Source Modular Cascaded Converter Based Photovoltaic Power System

A duty-cycle predictive control is proposed for dc grid integration of front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The post-stage qZS half-bridge dc-dc converter deals with PV maximum power point tracking, dc grid integration, and dc-link voltage balance; whereas, the front-end isolation converters operate at a constant duty cycle of 50%. Thus, it saves control hardware resources while overcoming challenges from PV-panel voltage variations and dc-bus voltage limit. The proposed control uses the derived circuit model to predict the global active-state duty cycle for grid-connected current control and predict the shoot-through duty cycles for dc-link voltage balance, achieving a fast and accurate tracking target. The proposed control method has advantages of: i) eliminating weighting factors that exist in conventional model predictive control (MPC), ii) no sophisticated loop parameters design that exists in proportional-integral (PI) control, iii) operating at constant switching frequency that is different from the conventional MPC with variable switching frequency. Simulation and experimental tests are carried out to verify the effectiveness of the proposed control method and compare with the PI-based control system.

42 ENGINEERING↗

Thermal Design Consideration of Medium Voltage High Frequency Transformers

This paper describes a thermal design using epoxy potting for high frequency transformer (HFT) for medium voltage high power electronic applications, namely emerging solid-state transformers. To address HFT’s thermal stress problem, thermal performance of the HFT with air and epoxy potting cooling method are both simulated by magnetothermal-fluid coupling method (MTFCM). The effectiveness of the simulation analysis is verified in a 100 kW DC-DC resonant converter. Influencing factors including distance between the high frequency transformer and the metal enclosure, epoxy thermal conductivity and heat sink placements are simulated and analyzed. Finally, an optimal cooling structure is proposed for future high power HFTs.

Wang, Haoming↗

Soft Switching Over the Entire Line Cycle for a Quadruple Active Bridge DCX in a DC to Three-Phase AC Module

This paper is focused on a transformer-isolated quadruple active bridge (QAB) dc-dc converter loaded by three full-bridge dc-ac inverters. The QAB functions as a "DC trans-former" (DCX) in the dc-to-three-phase ac module. The QAB outputs provide time-varying power at twice the line frequency, which presents challenges in maintaining zero voltage switching (ZVS) on the secondary sides during low-power portions of the line cycle. It is shown how ZVS can be achieved in a phase, even at zero-power transfer, using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. The approach is particularly effective in high-voltage applications using SiC MOSFETs, where reductions in switching loss outweigh additional conduction losses due to the circulating currents. A detailed analysis of ZVS switching waveforms at the zero power transfer is presented, including effects of nonlinear device capacitances. Analytical expressions are given for the optimal values of the magnetizing inductance and dead times of the QAB primary and secondary bridges. The approach is verified by experimental results on a 600 V, 4 kW prototype, demonstrating greater than 98.5% efficiency from 1 kW to 4 kW, with a peak efficiency of 99.0%. Compared to conventionally operated prototype, a 54% reduction in total loss is achieved at rated power.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Novel Decentralized PWM Interleaving Technique for Ripple Minimization in Series-Stacked DC-DC Converters

Cascaded dc-dc converters are commonly used in applications where distributed energy sources or loads are connected to elevated voltage levels for power transfer. In such systems, it is advantageous to minimize the ripple on the bus current and voltage by proper phase shifting of the pulse-width modulation (PWM) pulses among the converters via a method known as interleaving. Existing approaches use either a centralized controller or separate communication lines among the stacked converters to control their relative PWM switch transitions. The key drawbacks are that these methods entail significant wiring, the central controller acts as a single point of failure, and implementation on very large numbers of units is impractical. In this paper, we introduce a decentralized interleaving control (DIC) strategy that acts on local current measurements at every converter and achieves communication-free PWM interleaving among the series-stacked converters. The proposed controller is simple in structure and is shown to converge asymptotically to the interleaved state irrespective of clock drifts among the digital signal processors. Experimental results are provided for a system of five series-connected converters showing a 10× reduction in the current ripple compared to normal operation.

cascaded converter↗

Medium Voltage Solid State Transformer for Extreme Fast Charging Applications

A modular and scalable solid state transformer (SST) with direct medium voltage (MV) AC connectivity is proposed to enable DC extreme fast charging (XFC) of electric vehicles. Single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration. The modular hardware is co-designed with decentralized control of the DC-DC stages where voltage and power balancing are achieved by each SPM using only its local sensor feedback; a centralized controller (CC) regulates the low voltage (LV) DC bus through the AFE stages without any sensor feedback form the SPMs. The controller architecture contrasts sharply with the prior art for MV AC to LV DC SSTs where high-speed bidirectional communication among SPMs and a CC are required for module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power units. Detailed small-signal analysis and controller design guidelines are developed. Furthermore, a soft start-up strategy is presented. The proposed converter and control structure are validated through simulation and experimental results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Evaluation of the Single-Phase Shift and Extended-Phase Shift Control for Isolated DC-DC Converter

Abstract: This paper presents a comparative evaluation of the Single-Phase Shift (SPS) and Extended-Phase Shift (EPS) controls for the isolated DC-DC Converter. The analysis is based on the power regulation range, flexibility of operation, current stress on power devices, system efficiency while focusing on the issue of backflow power, control complexity, design and implementation overhead, and stability of the entire system. It is also examined how the backflow influences power circulation and increases current stress. Here, the Dual Active Bridge (DAB) Converter is employed to assess the performance of the control methods. Compared to SPS control, EPS offers a wider power regulation range, greater flexibility, lower current stress, and better system efficiency. However, EPS has increased control complexity, design and implementation overhead, and often requires sophisticated feedback control loops. The comparison is made through mathematical modeling of power transfer, backflow, and current stress. Simulation results validate the comparative analysis presented.

Amir, Aamir [The University of Alabama (UA)]↗

An Active Detection Scheme for Sensor Spoofing in Grid-tied PV Systems

In this paper an active detection scheme for sensor spoofing (manipulated externally via a cyber attack) in grid-tied PV systems is discussed. The core of the proposed active detection scheme is to introduce a private (secret) watermarking signal into the control inputs of the DC-DC converter and DC-AC inverter stages to detect any malicious spoofing (manipulation) of voltage/current sensor measurements controlling both the DC-DC converter maximum power point tracking (MPPT) stage and the DC-AC inverter of the grid-tied PV system. Several types of possible spoofing mechanisms (attack models) are discussed. The proposed sensor spoofing attack detector system consists of injecting a small magnitude of digital watermarking signal (DWS) and conduct three statistical watermark tests on the reported sensor measurements to determine if a) the proposed system is healthy and operating as expected b) if sensor signals were spoofed (manipulated) externally or c) if a particular sensor is malfunctioning due to a faulty hardware. It is shown via extensive simulations that the proposed DWS approach is robust in detecting malicious external manipulation of sensors controlling the grid tied PV system. A testing platform is currently under development and the experimental results will be discussed in the conference presentation.

Ibrahim, Hasan↗

3.5 kW/in3 Planar Coupled Inductor Design and Optimization for a 50 kW 3-level Four-Switch Buck-Boost (3L-FSBB) Converter

Planar magnetics design has been widely used in power electronics field because of the low profile, ease of manufacturability, and high power density. This paper first proposes a 3-level four-switch buck-boost (3L-FSBB) converter for the dc-dc applications where the zero common-mode (CM) voltage emissions, step-up and step-down are all required. With the consideration of power density, efficiency, and cost, a 15oz heavy copper coupled inductor for 3-level FSBB converter was designed and optimized with the low-cost commercial core and planar windings. According to the soft-switching quadrangle modulation for 3-L FSBB, the turns number and stacked core number are optimized first. And then, a two-board design is proposed to reduce the fringing effect and improve the thermal performance. Finally, a 75 kVA two-stage ac-dc-dc converter including a 3-level FSBB converter was built to verify the electrical design.

Cao, Yuliang↗

A 75 kVA Intelligent Power Stages (IPS) Unit Design for Future Grid-interface Application

The demand for grid-interface converter with flexible dc bus is driven by the fast development of energy storage system (ESS), electric vehicle (EV) charging system, and versatile residential load. This paper first proposes a two-stage intelligent power stage (IPS) unit for future grid-interface applications. To achieve zero common-mode (CM) voltage emissions, step-up and step-down voltage gain, a 3-level four-switch buck-boost (3-L FSBB) dc-dc converter is adopted with fully zero voltage switching (ZVS). In one IPS unit, an advanced fiberoptic communication with sub-nanosecond synchronization is developed for different enhanced gate drivers. Moreover, an enhanced gate driver integrated current and voltage sensors is designed for monitoring and diagnostics. To achieve a whole low-profile design, three 12 oz heavy copper planar ac inductors are designed and implemented. Finally, a 75 kVA IPS unit was built to verify both the thermal and electrical design.

Cao, Yuliang↗

A Self-Organizing Nano Grid (SONG) for Energy Access Clusters

In this paper, a bottom-up dc Self-Organizing Nano Grid (SONG) for rural electrification at ultra-low-cost through a flexible and scalable topology is presented. The proposed nano grid requires no communication and uses dc-bus signaling to convey excess energy in the system through the bus voltage, allowing independent agents to conduct energy transactions based on their needs in a decentralized manner. Moreover, this article proposes a concept that uses a novel multi-source, multi-segment droop control strategy with demand coordination, allowing for dynamic self-balancing of the system under fluctuating operating conditions. The unique use of a surplus photovoltaic (PV) power droop mode precisely estimates energy availability to minimize load chattering that helps in stabilizing the dc-bus. In addition, this architecture uses standard dc/dc converters for a low-cost, modular, Plug and Play ( PnP ) solution with highly automated operation, enabling local assembly, operation, and maintenance by non-technical personnel. The proposed SONG concept was validated in simulation and with a 700W, laboratory-scale, custom made nano grid system. The simulation and experimental test cases show the feasibility of the SONG system by demonstrating the proposed multi-source, multi-segment droop control strategy without load chattering under varying operating conditions.

dc-dc converter↗

Traction Inverter Integrated On-Board DC Fast Charging through Partial Power Processing

This paper introduces an innovative on-board integrated DC charging approach through partial power processing (PPP) in a traction inverter system. The proposed system, incorporating a series-connected partial power dual-active-bridge (DAB) converter, efficiently regulates the DC link voltage to achieve an optimal bus voltage for traction operation across a wide speed and torque range. Leveraging partial and bidirectional power processing, the battery current during charging is precisely regulated without the need for external DC-DC charging equipment, ensuring seamless integration to a DC hub with different voltage levels. This advanced integration also endows the system with bidirectional power exchange capability to/from the external DC hub, i.e., vehicle-to-DC (V2DC).

DAB↗

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter↗

Analysis and Comparison of Different Metrics of DC-DC Converters to Determine Fuel Cell Stack Architectures in Heavy Duty Fuel Cell Vehicle Applications

This paper presents a comparative study of the DC-DC converters used in heavy-duty fuel cell electric vehicles for different input fuel cell stack configurations and voltages in terms of various important metrics including efficiency, cost, weight and power density. Contrary to conventional use of an interleaved boost topology, the analysis presented in this paper demonstrates that improved converter metrics can be achieved for an interleaved buck topology that uses a different input fuel cell stack. An insight to the optimal choice of number of interleaved phases for each metric is also presented. Results presented in the tables and plots convey the findings.

Mukherjee, Subho↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

A Novel Low-Profile High-Efficiency Three-Phase Matrix Transformer

High step-down isolated DC-DC conversion from an 800 V DC bus to low-voltage, high-current outputs is required in automotive auxiliary converters and data center power supplies. In such applications, conventional transformer-based converters require large turns ratios, which increase winding resistance, leakage inductance, and magnetic height. This paper proposes a novel low-profile three-phase matrix transformer that realizes a large effective voltage ratio through flux division among multiple secondary legs, without increasing the physical turns count of each winding. As a result, the proposed structure reduces copper usage and transformer height while preserving the voltage conversion capability of a conventional three-phase transformer. Finite element analysis shows that the proposed design reduces magnetic height by 27%, ferrite volume by 34%, and copper volume by 28%. Circuit-level simulations of an 800 V/12 V,3 kW CLLLC dual-active-bridge converter further show that the lower winding resistance reduces total system loss by 91% and increases DC-DC efficiency from 82.6% to 97.6% at 3 kW output.

Inoue, Shuntaro [ORNL] (ORCID:0000000262637627)↗

Hierarchical Control and Stability Analysis for a Nonisolated Grid-Tied DC Energy Router Integrating Energy Storage and Partial Distributed Generation

This article proposes a nonisolated dc converter-based energy router (dc-ER) and its operating strategy. Here, the intent is to integrate energy storage (ES), distributed generation (DG), local load, and dc power grid in an autonomous and more efficient way. The ES/DG power ports are coupled with each other in partial-type connections, which obtains higher voltage supply gain and direct input–output power transmission. High-voltage supply gain allows a wide solar power tracking range and the possibility of optimal battery charging/discharging. Direct input–output power transmission improves the energy conversion efficiency. In this article, the operating modes of dc-ER are first analyzed, followed by the optimal hardware design counting the DG current ripple minimization and the limitation caused by the power flow direction. Second, the mathematical model of dc-ER is deduced. The hierarchical control is then proposed to manage port energy in a flexible manner. The stability is analyzed by using impedance modeling. Finally, experimental and simulation results verify the superiorities of the proposed topology in terms of flexible operating mode transition and high-power conversion efficiency.

25 ENERGY STORAGE↗

Frequency Response Improvement in a Standalone Small Hydropower Plant Using Battery Storage

This paper proposes a control architecture for frequency, current, and voltage control that facilitates using battery storage to improve the response of standalone small hydropower plants. The frequency controller uses rate-of-change of frequency and frequency-Watt-based generations to produce active power commands. The distinctive feature of the controller design is that it nicely integrates response to frequency change with constraints on frequency and state of battery to enable power injections. The current and voltage control scheme allows incorporating the frequency controller. The distinctive feature of this controller is that it incorporates a bounded integral control strategy that guarantees stability. Results on the stability of the hydropower plant with proposed scheme are presented and robust ways to choose the controller gains are investigated via root locus analysis. In conclusion, simulations performed show that: the hydropower plant response is significantly improved with battery storage using the proposed scheme; the load carrying capability of the hydropower plant is significantly improved with battery storage; the proposed scheme has the capability to recharge the battery; and the proposed control scheme gives improved performance.

13 HYDRO ENERGY↗

Novel Quadratic High Gain Boost Converter With Adaptive Soft-Switching Scheme and Reduced Conduction Loss

In this article, an improved soft-switching quadratic boost converter is proposed. Instead of inserting an additional active clamp or auxiliary zero-voltage transition circuit at the switching node, the proposed topology connects the high-voltage switching node to the input diode node by replacing one of the input diodes with a low-rated switch. The proposed topology can attain soft-switching condition for all the switches and input diode turns- off under zero-current switching (ZCS). The operation of input-side switch not only aids zero-voltage switching (ZVS) turn- on for the main switch but also helps in reducing the conduction loss. Also, the input-side switch operates under ZCS turn- on and ZVS turn- off , making it a loss economical solution. An adaptive timing scheme for driving the input switch is proposed, which can ensure soft-switching condition under varying gain and load range. The detailed operational modes, analysis, and design considerations of the proposed topology are presented. A 250 W hardware prototype is built to validate the performance of the proposed converter operating at 100 kHz switching frequency. Results with adaptive soft-switching scheme shows that the converter is modulated to achieve its best efficiency condition under various system conditions. Furthermore, a peak efficiency of 96.1% at 155 W and efficiencies above 95.75% over a wide load range are achieved using all Si devices.

14 SOLAR ENERGY↗