SEARCH · Search NASA
Results for “DCC”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC
Utilities and grid operators worldwide are under significant pressure to incorporate intermittent renewable sources while strategizing on how to maintain the necessary stability and reliability of the grid. The development of a power plant which will be capable of flexible operation to meet the needs of the grid as more intermittent sources like wind and solar energy are incorporated is key to maintain the reliability of the grid. Through the use of innovative and cutting-edge technologies that improve efficiency and reduce carbon emissions, and being small compared to today's conventional utility-scale power plants, the modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. Specifically, the process offers: 1) a modular plant design that allows for better operational flexibility; 2) the utilization of fuel-staging and pressurized oxy-combustion, resulting in smaller plant size, improved plant efficiency, and reduced costs for pollutant and CO2 removal compared to traditional power plants with post-combustion capture technology; and 3) the use of small modular boilers and pollutant removal units that can be constructed off-site leading to reduced capital costs for the plant. WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustor-boiler system and the direct contact cooler. To demonstrate the boiler convective section and to obtain critical data for commercial-scale pressurized boiler design, a simulated convective heat transfer boiler test section was designed and integrated with the combustor (radiant section). A direct contact cooler (DCC) was integrated with the combustor-boiler to demonstrate the dynamic operation of the integrated system and the performance of the DCC, including the efficiency for simultaneous removal of NOx and SOx. This talk will present an update on the evaluation of the critical components for system integration, including heat transfer data from the simulated boiler, scrubbing efficiency for the DCC under different operating conditions, and CFD modeling and validation for burner and boiler development.
Density Effects on Lock Exchange Flow During a DCC
The High Temperature Test Facility (HTTF) is a scaled, electric model at Oregon State University (OSU) of the Modular High Temperature Gas Reactor (MHTGR) by General Atomics. There are a few major differences between the design and the OSU facility. In the HTTF the reactor pressure vessel and the reactor cavity are in two separate tanks connected by a crossover duct similar to the crossover duct that would be seen between the reactor core and the steam generator in the MHTGR. This feature allows for the facility to open two main break valves simulating a Double-Ended Guillotine Break (DEGB) of the cross over duct, synonymous to a crossover duct break in the MHTGR. The density gradient driven flow phenomena in the HTTF duct can then be studied further. This break would cause a depressurization of the reactor and a loss of flow. It is called the Depressurized Loss of Forced Convection Accident (D-LOFC), also known as the Depressurized Conduction Cool-Down Event for High Temperature Gas Reactors (HTGRs) because heat removal is by conduction through the core and radiation out of the vessel. The HTTF was built and scaled to maintain the highest accuracy for the DCC. Prototypical temperatures with an inlet temperature of 259 deg. C and an outlet temperature of 687 deg. C are maintained in the HTTF. The temperature profile is also maintained in the smaller volume by using a ceramic core. The HTTF uses graphite heaters because the resistive heat produced does not change significantly with temperature . In order to produce a facility of similar temperatures within the allotted budget, sacrifices had to be made in other areas. The HTTF is scaled one-fourth in diameter, one-fourth in height and one-eighth in pressure of the MHTGR. There are also a few limitations for the HTTF. While in the MHTGR, the cavity is filled with air, the HTTF uses highly pure Nitrogen and does not have the ability to simulate a full depressurization. The DCC event is traditionally comprised of multiple stages: depressurization, molecular diffusion and natural circulation. However, this traditional interpretation ignores lock exchange flow which will occur immediately following depressurization and could have significant consequences in the reactor. It was found that the traditional model underestimates the amount of air ingress by at least 660 times according to Oh and Kim in their theoretical research of air ingress. Molecular diffusion also decreases with stratification. Any model that specifies the gases are stratified has further underestimated the air ingress of the DCC event. In addition, molecular diffusion is a much slower process, allowing the reactor to shut down and cool off considerably from operating temperatures. Thus, understanding lock exchange flow, the air ingress concentrations and the time scale is critical to MHTGR research and licensing. (authors)
RESRAD for Radiological Risk Assessment. Comparison with EPA CERCLA Tools - PRG and DCC Calculators
The purpose of this report is two-fold. First, the risk assessment methodology for both RESRAD and the EPA’s tools is reviewed. This includes a review of the EPA’s justification for 2 using a dose-to-risk conversion factor to reduce the dose-based protective ARAR from 15 to 12 mrem/yr. Second, the models and parameters used in RESRAD and the EPA PRG and DCC Calculators are compared in detail, and the results are summarized and discussed. Although there are suites of software tools in the RESRAD family of codes and the EPA Calculators, the scope of this report is limited to the RESRAD (onsite) code for soil contamination and the EPA’s PRG and DCC Calculators also for soil contamination.
EBAC-DCC Analysis of World Data of pi N, gamma N, and N(e,e') Reactions
The development, results, and prospect of the Dynamical Coupled-Channels analysis at Excited Baryon Analysis Center (EBAC-DCC) are reported. In this contribution, we report on the development, results, and prospect of EBAC. The EBAC project has three components, as illustrated in Fig. 1. The first task is to perform a dynamical coupled-channels analysis of the world data of {pi}N, {gamma}*N {yields} {pi}N, {eta}N, {pi}{pi}N, K{Lambda}, K{Sigma}, {omega}N, {hor_ellipsis} to determine the meson-baryon partial-wave amplitudes. The second step is to develop a procedure to extract the N* parameters from the determined partial-wave amplitudes. The third step is to investigate the interpretations of the extracted N* properties in terms of the available hadron models and Lattice QCD.
Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC
Critical to the future of power generation is the development of a power plant that will be capable of flexible operation to meet the needs of the modern grid, providing resilient, low-emissions power to a grid that is increasingly seeing a large penetration of intermittent wind and solar. The modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. The process offers: 1) a modular plant design for improved operational flexibility; 2) fuel-staging combined with pressurized oxy-combustion, which leads to smaller plant size, higher plant efficiency, and lower cost for pollutant and greenhouse gas removal compared with traditional carbon-capture equipped coal power plants; and 3) small modular boilers and pollutant removal units that can be fabricated in shop and assembled on site, further reducing plant capital costs. Under DOE's support (DE-FE0031925), WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustion system and the direct contact cooler (DCC) from Technology Readiness Level (TRL) 4 to TRL-5, which would allow these technologies to be subsequently incorporated into a pilot plant. This talk will present an overview of the SPOC technology, CFD modeling and validation for burner and boiler development, and recent results to evaluate critical components for system integration needed to advance its TRL.
ICRF DCC Solid State Transmitter
Explore the source record for details and available documents.
The binding of DCC-P3 motif and FAK-FAT domain mediates the initial step of netrin-1/DCC signaling for axon attraction
Abstract not provided
*-DCC: A platform to collect, annotate, and explore a large variety of sequencing experiments
Background: Over the past few years the variety of experimental designs and protocols for sequencing experiments increased greatly. To ensure the wide usability of the produced data beyond an individual project, rich and systematic annotation of the underlying experiments is crucial. Findings: We first developed an annotation structure that captures the overall experimental design as well as the relevant details of the steps from the biological sample to the library preparation, the sequencing procedure, and the sequencing and processed files. Through various design features, such as controlled vocabularies and different field requirements, we ensured a high annotation quality, comparability, and ease of annotation. The structure can be easily adapted to a large variety of species. We then implemented the annotation strategy in a user-hosted web platform with data import, query, and export functionality. Conclusions: We present here an annotation structure and user-hosted platform for sequencing experiment data, suitable for lab-internal documentation, collaborations, and large-scale annotation efforts.
Nucleon Resonances From EBAC-DCC Analysis for Investigating Confinement Physics
Explore the source record for details and available documents.
ICRF DCC Solid State Transmitter
Explore the source record for details and available documents.
Lifecycle of updrafts and mass flux in isolated deep convection over the Amazon rainforest: insights from cell tracking
Long-term observations of deep convective cloud (DCC) vertical velocity and mass flux were collected during the Observations and Modelling of the Green Ocean Amazon (GoAmazon2014/5) experiment. Precipitation echoes from a surveillance weather radar near Manaus, Brazil, are tracked to identify and evaluate the isolated DCC lifecycle evolution during the dry and wet seasons. A radar wind profiler (RWP) provides precipitation and air motion profiles to estimate the vertical velocity, mass flux, and mass transport rates within overpassing DCC cores as a function of the tracked cell lifecycle stage. The average radar reflectivity factor (Z), DCC area (A), and surface rainfall rate (R) increased with DCC lifetime as convective cells were developing, reached a peak as the cells matured, and decreased thereafter as cells dissipated. As the convective cells mature, cumulative DCC properties exhibit stronger updraft behaviors with higher upward mass flux and transport rates above the melting layer (compared with initial and later lifecycle stages). In comparison, developing DCCs have the lowest Z associated with weak updrafts, as well as negative mass flux and transport rates above the melting layer. Over the DCC lifetime, the height of the maximum downward mass flux decreased, whereas the height of the maximum net mass flux increased. During the dry season, the tracked DCCs had higher Z, propagation speed, and DCC area, and were more isolated spatially compared with the wet season. Dry season DCCs exhibit higher Z, mass flux, and mass transport rate while developing, whereas wet season DCCs exhibit higher Z, mass flux, and mass transport rates at later stages.
Integrated Flue Gas Purification and Latent Heat Recovery for Pressurized Oxy-Combustion (Final Scientific/Technical Report)
Pressurized oxy-combustion has been identified by DOE as a transformational technology for coal power with carbon capture due to the advantages that are realized when the combustion process is pressurized. The staged pressurized oxy-combustion (SPOC) process is particularly attractive as the efficiency of the process is almost 6 percentage points greater than that of first generation oxy-combustion. A critical component of the SPOC process, and potentially other pressurized combustion processes, is the Direct Contact Cooler (DCC) where the latent heat of the flue gas moisture is recovery to improve plant efficiency while simultaneously removing SO x and NO x from the flue gas, so that the FGD and de-NO x processes can be eliminated, and the cost of electricity minimized. The objective of this R&D effort was to advance the TRL of the DCC technology, which included performance testing at a 100 kW scale to validate the process and obtain key engineering data for scale-up. A collateral objective was to study the gas- and liquid-phase kinetics, and the development of a systematic chemical mechanism validated by experimental data. Experiments in a bench-scale stirred reactor provided an updated understanding of the liquid chemistry and the effects of temperature and pH. This information was used to develop a reduced reaction mechanism, which was subsequently incorporated in an ASPENbased process model, to allow for evaluation of the DCC at full scale. A small-pilot DCC column was designed, constructed and tested using simulated flue gas at the pressurized oxy-combustion test facility at Washington University in St. Louis. In the majority of tests, the SO 2 capture approached 100%, making the NO x capture the primary metric of capture efficiency. An NO x capture efficiency of 90% was achieved when the gas residence time was 95 seconds, demonstrating that high capture rates can be attained with reasonable reactor size. At higher temperatures (up to 200°C inlet gas temperature) the total NO x scrubbing efficiency was reduced by approximately 10% (compared to room temp.) and this was attributed to a reduced NO oxidation rate. A significant amount of SO 2 was present in the gas outlet (10%) only when the temperature was high and the N:S ratio was low (N/S < 1), which highlights the necessity of controlling the NOx concentration in the flue gas for complete sulfur scrubbing. After incorporated our optimized chemical mechanism into an ASPEN process model, various full-scale configurations of the DCC were evaluate, and the results indicate that the proposed DCC can accomplish its intended goals at full scale and at a modest size. Thus, the results of this project indicate that the DCC is a promising technology for recovery of the latent heat of the moisture in the flue gas while simultaneously scrubbing the nitrogen and sulfur oxides, thus enabling pressurized oxy-combustion, in general, and the SPOC process, in particular.
RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26
The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.
Modeling of HTTF test PG-26 using RELAP5-3D and SAM
The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors (HTGR) with prismatic fuel and reflector blocks [1]. Several tests have been completed at the HTTF including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This summary reports on the analysis of test PG-26 using the INL system code REALP5-3D [2] as well as the ANL system code SAM [3]. Test PG-26 is a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC [4]. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heater banks. The DCC transient was initiated during the 50th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test.
DC-Saturated Continuously Variable Series Reactors (CVSRs) for Power Flow Control in Power Transmission Systems
This paper proposes a novel continuously variable series reactor (CVSR) based on a dc current controller (DCC) to manage power flow in transmission systems. There are three major contributions. First, the three-dimensional electromagnetic interaction has been comprehensively analyzed to extend the understanding beyond the conventional 2D relationship. Second, a high-fidelity reluctance model of the CVSR with an improved DCC model is proposed and implemented. To overcome the fundamental concern for the system modeling, the DCC has been modeled as an ideal current source in parallel with an output impedance. Additionally, the induced back-EMF can be precisely projected which provides critical design guidelines for the DCC. Third, inspired by the theoretical analysis and modeling, a reliable high power DCC converter is designed accordingly to interface with kV-level back-EMF and supply kA-level dc current for a 115 kV/1500 A CVSR. Experiments are conducted in a practical transmission demonstration system. When the ac current in the transmission system varies from zero to 1500 A, experimental results show that the proposed CVSR can continuously regulate the reactance from 1.6 Ω to 5 Ω, validating the effectiveness of the proposed system design and modeling methodology.
Monochromatic wavelength dispersive x-ray fluorescence providing sensitive and selective detection of uranium
Monochromatic wavelength dispersive X-ray fluorescence (MWDXRF) is a sensitive and selective method for elemental compositional analyses. The basis for this instrumental advance is the doubly curved crystal (DCC) optic. Previous work has demonstrated the feasibility of sensitive trace element detection for yttrium as a surrogate for curium in aqueous solutions. Additional measurements have demonstrated similar sensitivity in several different matrix environments which attests to the selectivity of the DCC optic as well as the capabilities of the MWDXRF concept. The objective of this effort is to develop an improved Pu characterization method for nuclear fuel reprocessing plants. The MWDXRF prototype instrument is the second step in a multi-year effort to achieve an improved Pu assay. This work will describe a prototype MWDXRF instrument designed for uranium detection and characterization. The prototype consists of an X-ray tube with a rhodium anode and a DCC excitation optic incorporated into the source. The DCC optic passes the RhK{alpha} line at 20.214 keV for monochromatic excitation of the sample. The source is capable of 50 W power at 50 kV and 1.0 mA operation. The x-ray emission from the sample is collected by a DCC optic set at the UL{alpha} line of 13.613 keV. The collection optic transmits the UL{alpha} x-rays to the silicon drift detector. The x-ray source, sample, collection optic and detector are all mounted on motion controlled stages for the critical alignment of these components. The sensitivity and selectivity of the instrument is obtained through the monochromatic excitation and the monochromatic detection. The prototype instrument performance has a demonstrated for sensitivity for uranium detection of around 2 ppm at the current state of development. Further improvement in sensitivity is expected with more detailed alignment.