Search NASA⌕ Search

SEARCH · Search NASA

Results for “DHI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Monthly Mean DNI and GTI Derived from Monthly Mean GHI and DHI Using Two Methods: Comparisons with the BSRN Data and the Results Derived from the CERES Hourly Data

Monthly mean Global Horizontal Irradiances (GHI) and Diffuse Horizontal Irradiances (DHI) are more widely available than monthly mean Direct Normal Irradiances (DNI) and Global Tilted Irradiances (GTI). Empirical methods have been developed to derive monthly mean DNI and GTI from monthly mean GHI or from GHI and DHI. In this paper, we evaluate two such methods. The first one was the Whitlock Method developed by Charles H. Whitlock (2005) for the NASA POWER project by means of regression of the BSRN data. The method expresses the monthly mean DHI-to-GHI ratio as polynomial functions of monthly mean clearness index, sunset hour angle and noon solar elevation angle on the monthly-average-day. The monthly mean DNI is calculated by dividing the monthly mean GHI-DHI difference, or DirHI, by the cosine of the solar zenith angle at the mid-time between sunrise and solar noon on the monthly-average-day. The second method is the LJCR Method developed by Liu and Jorden (1960) and Collares-Pereira and Rabl (1979), and this method empirically splits monthly mean GHI and DHI into hourly means on the monthly-average-day, and the resulting hourly mean GHI and DHI and their difference, DirHI, can then be used to compute the monthly mean DNI, GTI and the global solar tracker irradiance (GTrI). This method is also used by RETScreen. We recently produced a set of hourly DNI and DHI by bias-correcting the CERES hourly DNI and DHI, and computed hourly GTI and GTrI as well. The data span twenty plus years from March 2000 to near present on a 1 by 1 grid system. The monthly mean CERES GHI and the corrected DHI are used as inputs to the above two methods to compute monthly mean DNI, GTI and GTrI. Through comparisons with the BSRN data, it is found that the Whitlock Method, with slight modification, and the LJCR Method can produce results that are nearly as good as the results derived from the CERES hourly data.

Taiping Zhang↗

The Use of the BSRN Data as A Benchmark for the POWER Hourly DHI and DNI and In Validating Derived Hourly GTI

The satellite-based CERES SYN1deg hourly data is the source data of the POWER GIS solar data that covers 2001 to near present. The SYN1deg(Ed4.1) hourly GHI agrees well with the BSRN data, but the hourly DHI and DirHI (Direct Horizontal Irradiance) are positively and negatively, respectively, biased with appreciable magnitudes. The hourly DNI, derived by dividing the DirHI by cos(SZA), or the cosine of the solar zenith angle, is therefore negatively biased. Based on the statistics of comparisons with the BSRN data, we performed bias corrections on the hourly DHI and DNI. The corrections were executed in the 3-D phase space of latitude, cos(SZA), and cloud fraction (CLFR). The isotropic model is then used to derive the hourly global tilted irradiance (GTI). For validation purpose, we applied the isotropic model to the BSRN data at the original 1-, 2-, 3- or 5-minute interval. The satellite-based hourly GTI shows good agreement with their BSRN counterpart. We also examined two monthly-mean-based methods that empirically derive monthly mean GTI and DNI from monthly mean GHI and from both monthly mean GHI and DHI. The monthly-mean-based results compare favorably with the hourly-mean-based results. The GEWEX SRB (V4-IP) provides POWER with daily mean GHI for the years before the CERES era, and the data were corrected using quantile mapping by referencing the CERES SYN1deg data. We used the Kolmogorov -Smirnov test (K-S test) and Cramer-von Mises test to examine how well the results agree with the BSRN data. We found that if we set the lower limit for the daily mean GHI to 30 W m-2, the data can pass the K-S test at 0.01 significance level and the Cramer-von Mises test at 0.001 significance level. If no lower limit is set on the daily means, the data fail both tests. The satellite-based CERES SYN1deg hourly data is the source data of the POWER GIS solar data that covers 2001 to near present. The SYN1deg(Ed4.1) hourly GHI agrees well with the BSRN data, but the hourly DHI and DirHI (Direct Horizontal Irradiance) are positively and negatively, respectively, biased with appreciable magnitudes. The hourly DNI, derived by dividing the DirHI by cos(SZA), or the cosine of the solar zenith angle, is therefore negatively biased. Based on the statistics of comparisons with the BSRN data, we performed bias corrections on the hourly DHI and DNI. The corrections were executed in the 3-D phase space of latitude, cos(SZA), and cloud fraction (CLFR). The isotropic model is then used to derive the hourly global tilted irradiance (GTI). For validation purpose, we applied the isotropic model to the BSRN data at the original 1-, 2-, 3- or 5-minute interval. The satellite-based hourly GTI shows good agreement with their BSRN counterpart. We also examined two monthly-mean-based methods that empirically derive monthly mean GTI and DNI from monthly mean GHI and from both monthly mean GHI and DHI. The monthly-mean-based results compare favorably with the hourly-mean-based results. The GEWEX SRB (V4-IP) provides POWER with daily mean GHI for the years before the CERES era, and the data were corrected using quantile mapping by referencing the CERES SYN1deg data. We used the Kolmogorov -Smirnov test (K-S test) and Cramer-von Mises test to examine how well the results agree with the BSRN data. We found that if we set the lower limit for the daily mean GHI to 30 W m-2, the data can pass the K-S test at 0.01 significance level and the Cramer-von Mises test at 0.001 significance level. If no lower limit is set on the daily means, the data fail both tests.

Taiping Zhang↗

The Hourly GHI, DHI and DNI: Intercomparison of the CERES-Based Data and the NSRDB Data through Comparison with the Ground-Based BSRN Data

The NASA Clouds and the Earth’s Radiant Energy System (CERES) SYN1deg(Ed4.1) provides hourly global horizontal irradiance (GHI), diffuse horizontal irradiance (DHI) and direct horizontal irradiance (DirHI) at 1-degree latitude by 1-degree longitude resolution, and the time span is from March 2000 to near present. While the GHI agrees well with the ground-based Baseline Surface Radiation Network (BSRN) data, the DHI and DirHI are, respectively, positively and negatively biased against the BSRN data, and so is the direct normal irradiance (DNI) derived simply by dividing the DirHI by the cosine of the hourly solar zenith angle (SZA). We found that the biases tend to be well-defined functions of cos(SZA) and the cloud fraction (CLFR). We thus performed a bias-correction on the hourly DHI and DNI in the latitude-cos(SZA)-CLFR phase space, and therefrom, we derived the hourly global tilted irradiance (GTI) at a number of tilt angles using the isotropic diffuse irradiance model, and the results agree well with the GTI derived from the original BSRN near-instantaneous records. Meanwhile, the National Renewable Energy Laboratory (NREL) has produced the National Solar Radiation Database (NSRDB) with finer spatiotemporal resolution using its Physical Solar Model (PSM) and surface-based measured data, model results and satellite-based data as inputs. Now the NSRDB data covers not only the United States and its neighboring regions, but Europe, Africa, Asia and Oceania. The available temporal resolutions are 5, 10, 15, 30 and 60 minutes and the spatial resolutions are 2, 4 and 10 km, depending on the selected region. In this presentation, we compare both the CERES-based and NSRDB GHI, DHI and DNI with their BSRN counterparts and show how finer spatial resolution may give us an advantage in data accuracy and usability.

Taiping Zhang↗

Use of Physics to Improve Solar Forecast: Physics-Informed Persistence Models for Simultaneously Forecasting GHI, DNI, and DHI

Observation-based statistical models have been widely used in forecasting solar energy; however, existing models often lack a clear relation to physics and are limited largely to global horizontal irradiance (GHI) forecasts over relatively short time horizons (< 1 hour). Incorporating physics into observation-based models, increasing forecast time horizons and developing a model system for forecasting not only GHI but also direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI) remain challenging, especially under cloudy conditions because of complex cloud-radiation interactions. This work attempts to address these challenges by developing a hierarchy of four new physics-informed persistence models that can be used to simultaneously forecast GHI, DNI and DHI. The decade-long measurements (1998 to 2014) at the U.S. Department of Energy's Atmospheric Radiation Measurement (ARM)'s Southern Great Plains (SGP) Central Facility site are used to evaluate the performance of the new models. Overall, the results show that the new physics-informed forecast models generally outperform the simple and smart persistence models, and improve the forecast accuracy at lead times from 1.25 hours up to 6 hours. Further analysis reveals that the forecast error is highly related to the error and temporal variability of the assumed cloud predictor. The best model for forecasting different radiative components can be explained by the relationship between solar irradiances and cloud properties.

54 ENVIRONMENTAL SCIENCES↗

Model for Deriving the Direct Normal and Diffuse Horizontal Irradiance from the Global Tilted Irradiance

We developed a separation model for deriving the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the global tilted irradiance (GTI). The model is based on the DIRINT model, but substitutes the use of the GTI in place of the global horizontal irradiance (GHI) for determining the global clearness index (Kt). Additionally, an iterative method is used to adjust Kt to improve the derived values of the DNI and the DHI. The model is referred to as the GTI-DIRINT model. When using for model input the GTI measured with a pyranometer tilted at a small angle from the horizontal (10°), the deviations between the measured DNI and DHI and the GTI-DIRINT-modeled DNI and DHI were essentially the same as those for the DIRINT model when using the GHI for model input. Increasing the tilt angle from horizontal (as great as 44° for Eugene, Oregon) increased the deviations between the modeled and measured DNI and DHI, but our results were still reasonable. The GTI-DIRINT model provides reasonable values of DNI and DHI from the GTI, and if they are subsequently used with the Perez tilted surface model to model the GTI for orientations within 30° of the azimuth and tilt of the GTI used for model input, the result is as good or better than may be obtained when using a measured DNI and DHI, and without their significant instrumentation cost.

14 SOLAR ENERGY↗

Worldwide benchmarking of cost-effective radiometers for direct and diffuse irradiance

Solar energy projects can benefit from direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI) measurements during all project phases. Several commercial measurement systems for DNI and DHI are available. Sun trackers with pyranometers and pyrheliometers can provide highly accurate measurements but are often impractical in solar energy applications. For less expensive and more robust sensors, it is often unclear which accuracy can be expected under a project site's specific atmospheric conditions. We address this challenge through our dedicated experimental comparison of relevant sensor systems (rotating shadowband irradiometer [short RSI], Delta-T SPN1, EKO MS-90, PyranoCam, Sunto CaptPro, Kipp & Zonen CSD3) at up to six sites worldwide. The RSI systems (rRMSD 3 to 8.6%, DNI; 4.8 to 7.6%, DHI) and PyranoCam (rRMSD 2.6 to 5.2%, DNI; 4.4 to 5.8%, DHI) exhibit similar error metrics and are the most accurate systems in the test. Delta-T SPN1 and EKO MS-90 (rRMSD 6.8 to 15%, DNI; 10.6 to 20.1%, DHI) but especially Kipp & Zonen CSD3 and Sunto CaptPro show significant deviations (rRMSD 17.7 to 20%, DNI; 33 to 58%, DHI). We evaluate the influence of relevant atmospheric parameters on the sensors' accuracies by a rather unique measurement setup. MS-90's DNI errors depend on DNI itself, with overestimations for low reference DNI. The deviations of SPN1's DHI and DNI measurements increase sharply in situations with high circumsolar irradiance. Also CaptPro and CSD3's increased measurement errors are related to circumsolar irradiance. For RSI and PyranoCam, only moderate influences on the measurements are identified, indicating a general applicability of these instruments.

14 SOLAR ENERGY↗

Influences of Cloud Microphysics on the Components of Solar Irradiance in the WRF-Solar Model

An accurate forecast of Global Horizontal solar Irradiance (GHI) and Direct Normal Irradiance (DNI) in cloudy conditions remains a major challenge in the solar energy industry. This study focuses on the impact of cloud microphysics on GHI and its partition into DNI and Diffuse Horizontal Irradiance (DHI) using the Weather Research and Forecasting model specifically designed for solar radiation applications (WRF-Solar) and seven microphysical schemes. Three stratocumulus (Sc) and five shallow cumulus (Cu) cases are simulated and evaluated against measurements at the US Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility, Southern Great Plains (SGP) site. Results show that different microphysical schemes lead to spreads in simulated solar irradiance components up to 75% and 350% from their ensemble means in the Cu and Sc cases, respectively. The Cu cases have smaller microphysical sensitivity due to a limited cloud fraction and smaller domain-averaged cloud water mixing ratio compared to Sc cases. Cloud properties also influence the partition of GHI into DNI and DHI, and the model simulates better GHI than DNI and DHI due to a non-physical error compensation between DNI and DHI. The microphysical schemes that produce more accurate liquid water paths and effective radii of cloud droplets have a better overall performance.

54 ENVIRONMENTAL SCIENCES↗

Digital holographic interferometry employing Fresnel transform reconstruction for the study of flow shear stabilized Z-pinch plasmas

The ZaP-HD Flow Z-Pinch project provides a platform to explore how shear flow stabilized Z-pinches could scale to high-energy-density plasma (HEDP) and fusion reactor conditions. ZaP-HD generates shear stabilized, axisymmetric Z-pinches with stable lifetimes approaching $60$$\mu$s. The goal of the project is to increase the plasma density and temperature compared to the previous ZaP project by compressing the plasma to smaller radii ($\approx 1$ mm). Radial and axial plasma electron density structure is measured using digital holographic interferometry (DHI), which provides the necessary fine spatial resolution. ZaP-HD's DHI system uses a 2 ns Nd:YAG laser pulse with a second harmonic generator ($\lambda = 532$ nm) to produce holograms recorded by a Nikon D3200 digital camera. The holograms are numerically reconstructed with the Fresnel transform reconstruction method to obtain the phase shift caused by the interaction of the laser beam with the plasma. This provides a two-dimensional map of line-integrated electron density, which can be Abel inverted to determine the local number density. The DHI resolves line-integrated densities down to $3\times 10^{20}$ m$^{-2}$ with spatial resolution near $10 \mu$m. This work presents the first application of Fresnel transform reconstruction as an analysis technique for a plasma diagnostic, and it analyzes the method's accuracy through study of synthetic data. It then presents an Abel inversion procedure that utilizes data on both sides of a Z-pinch local number density profile to maximize profile symmetry. Error estimation and Abel inversion are applied to measured data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-P-46: Comparative Study Between Two Normalization Prescriptions for Accelerated Partial Breast Irradiation: A Dosimetric Study

Purpose: To compare the Accelerated Partial Breast Irradiation (APBI) plan with the normalized basal dose points and 5mm box prescription. Methods: Five patients of APBI were planned twice in Oncentra Master planning TPS (Version 4.3) using TG-43 algorithm. The number of catheters for all the patients was 10 to 16 and implant plane 2 to 3. For planning all catheters were reconstructed. Source loading was done as per HR-CTV contoured. The HR-CTV volume range was from 75cc to 182cc. Plans were normalized in two methods. First all plans were normalized on Basal dose points (PlanA) and second all the plan were normalized on 5mm box (PlanB). The prescription dose (PD) was 35Gy in 10 fractions. All the plans were completely based on normalization and without optimization. Plan evaluation was based on certain parameters coverage Index (CI), dose homogeneity index (DHI), conformity index (COIN), over dose volume index (OI). Results: The average and median of CI for planA was 0.835 and 0.8154, for planB 0.82 and 0.799 respectively. The median and average of DHI for planA was 0.66 and 0.6062, for planB 0.67 and 0.62 respectively. The range of COIN for planA and planB was from 0.58 to 0.65 respectively. The range of OI was from 0.083 to 0.169 for planA and planB. The treatment time in planA was in average 1.13 times more than planB as V150% of HR-CTV in planA was 4–6% more. The ipsilateral lung was getting 30% of PD which was 0.6% to 3.5%. Conclusion: Treatment Planning should be individualized based on implants characteristics. Planning with prescription to basal dose points should be preferred to 5mm box prescription, in order to achieve better DHI and less treatment time.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-01: A Simulation Study to Investigate Maximum Allowable Deformations of Implant Geometry Before Plan Objectives Are Violated in Prostate HDR Brachytherapy

Purpose: In prostate HDR brachytherapy dose distributions are highly sensitive to changes in prostate volume and catheter displacements. We investigate the maximum deformations in implant geometry before planning objectives are violated. Methods: A typical prostate Ir-192 HDR brachytherapy reference plan was calculated on the Oncentra planning system, which used CT images from a tissue equivalent prostate phantom (CIRS Model 053S) embedded inside a pelvis wax phantom. The prostate was deformed and catheters were displaced in simulations using a code written in MATLAB. For each deformation dose distributions were calculated, based on TG43 methods, using the MATLAB code. The calculations were validated through comparison with Oncentra calculations for the reference plan, and agreed within 0.12%SD and 0.3%SD for dose and volume, respectively. Isotropic prostate volume deformations of up to +34% to −27% relative to its original volume, and longitudinal catheter displacements of 7.5 mm in superior and inferior directions were simulated. Planning objectives were based on American Brachytherapy Society guidelines for prostate and urethra volumes. A plan violated the planning objectives when less than 90% of the prostate volume received the prescribed dose or higher (V{sub 100}), or the urethral volume receiving 125% of prescribed dose or higher was more than 1 cc (U{sub 125}). Lastly, the dose homogeneity index (DHI=1-V{sub 150}/V{sub 100}) was evaluated; a plan was considered sub-optimal when the DHI fell below 0.62. Results and Conclusion: Planning objectives were violated when the prostate expanded by 10.7±0.5% or contracted by 11.0±0.2%; objectives were also violated when catheters were displaced by 4.15±0.15 mm and 3.70±0.15 mm in the superior and inferior directions, respectively. The DHI changes did not affect the plan optimality, except in the case of prostate compression. In general, catheter displacements have a significantly larger impact on plan optimality than prostate volume changes.

60 APPLIED LIFE SCIENCES↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗

A Break In the Size-Stellar Mass Relation: Evidence for Quenching and Feedback in Dwarf Galaxies

Mapping stars and gas in nearby galaxies is fundamental for understanding their growth and the impact of their environment. This issue is addressed by comparing the stellar ‘edges’ of galaxies D stellar, defined as the outermost diameter where in situ star formation significantly drops, with the gaseous distribution parameterized by the neutral atomic hydrogen diameter measured at 1M⊙/pc2,DHI. By sampling a broad HI mass range 105M⊙< MHI<1011M⊙, we find several dwarf galaxies withMHI<109M⊙from the field and Fornax Cluster which are distinguished by D stellar>> DHI. For the cluster dwarfs, the average HI surface density near D stellar is∼0.3M⊙/pc2, reflecting the impact of quenching and outside-in gas removal from ram pressure and tidal interactions. In comparison, D stellar/DHI ranges between 0.5–2 in dwarf field galaxies, consistent with the expectations from stellar feedback. Only more massive disk galaxies in the field can thus be characterized by the common assumption that D stellar≲DHI. We discover a break in the D stellar−M⋆relation atm break∼4×108M⊙that potentially differentiates the low mass regime where the influence of stellar feedback and environmental processes more prominently regulates the sizes of nearby galaxies. Our results highlight the importance of combining deep optical and HI imaging for understanding galaxy evolution.

Scaling relations↗

Transplantation of dedifferentiation fat cells promotes intervertebral disc regeneration in a rat intervertebral disc degeneration model

Our group has reported that mature adipocyte-derived dedifferentiated fat (DFAT) cells show multilineage differentiation potential similar to that observed in mesenchymal stem cells. In the present study, we examined whether DFAT cell transplantation could contribute to intervertebral disc regeneration using a rat intervertebral disc degeneration (IDD) model. The IDD was created in Sprague-Dawley rats by puncturing at level of caudal intervertebral disc under fluoroscopy. One week after injury, rat DFAT cells (5 × 10{sup 4}, DFAT group, n = 13) or phosphate-buffered saline (PBS, control group, n = 13) were injected into the intervertebral disc. Percent disc height index (%DHI) was measured every week and histology of injured disc was evaluated at 8 weeks after transplantation. Radiographic analysis revealed that the %DHI in the DFAT group significantly higher than that in the control group at 2–3 weeks after transplantation. Histological analysis revealed that ectopic formation of nucleus pulposus (NP)-like tissue at the outer layer of annulus fibrosus was frequently observed in the DFAT group but not in the control group. Transplantation experiments using green fluorescent protein (GFP)-labeled DFAT cells revealed that the ectopic NP-like tissue was positive for GFP, suggesting direct differentiation of DFAT cells into NP-like cells. In conclusion, DFAT cell transplantation promoted the regeneration of intervertebral disc and improved intervertebral disc height in the rat IDD model. Because adipose tissue is abundant and easily accessible, DFAT cell transplantation may be an attractive therapeutic strategy against IDD. - Highlights: • Dedifferentiated fat cells (DFATs) are adipocyte-derived mesenchymal stem-like cells. • DFAT injection increases disc height in a rat intervertebral disc degeneration model. • Transplanted DFATs directly differentiate into the nucleus pulposus-like tissue. • DFATs may be an attractive cell source for intervertebral disc degeneration.

60 APPLIED LIFE SCIENCES↗

Photovoltaic system derived data for determining the solar resource and for modeling the performance of other photovoltaic systems

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. Here, a method was developed to back-solve for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the measured ac power of south-facing PV module/micro-inverter systems. The method was validated using one year of irradiance and PV performance measurements for five PV systems, each with a different tilt/azimuth orientation, and located in Golden, Colorado. Compared to using a measured global horizontal irradiance for PV performance model input, using the back-solved values of DNI and DHI only increased the range of mean bias deviations from measured values by 0.6% for the modeled annual averages of the global tilt irradiance and ac power for the five PV systems. Correcting for angle-of-incidence effects is an important feature of the method to prevent underestimating the solar resource and for modeling the performance of PV systems with more dissimilar PV module orientations. The results for the method were also shown more favorable than the results when using an existing power projection method for estimating the ac power.

14 SOLAR ENERGY↗

The Holy Grail of Resource Assessment: Low Cost Ground-Based Measurements with Good Accuracy

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within +/-4%, and only 1% greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis shows the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.

14 SOLAR ENERGY↗

SU-F-T-87: Comparison of Advanced Radiotherapy Techniques for Post- Mastectomy Breast Cancer Patients

Purpose: To determine if bolus electron conformal therapy (Bolus-ECT) combined with intensity modulated x-ray therapy (IMXT) and flattening filter free volumetric modulated arc therapy (FFF-VMAT (6x and 10x)) can maintain equal or better dose coverage than standard volumetric modulated arc therapy (Std-VMAT) while reducing doses to organs at risk (OARs). Methods: Bolus-ECT with IMXT, FFF-VMAT, and Std-VMAT treatment plans were produced for ten post-mastectomy radiotherapy (PMRT) patients previously treated at our clinic. The treatment plans were created on commercially available treatment planning system (TPS) and all completed treatment plans were reviewed and approved by a radiation oncologist. The plans were evaluated based on planning target volume (PTV) coverage, tumor control probability (TCP), dose homogeneity index (DHI), conformity index (CI), and dose to organs at risk (OAR). Results: All techniques produced clinically acceptable PMRT plans. Overall, Bolus-ECT with IMXT exhibited higher maximum dose compared to all VMAT techniques. Bolus-ECT with IMXT and FFF-VMAT10x had slightly improved TCP over FFF-VMAT6x and Std-VMAT. However, all VMAT techniques showed improved CI and DHI over Bolus-ECT with IMXT. All techniques showed very similar mean lung dose. Bolus-ECT with IMXT exhibited a reduced mean heart dose over Std-VMAT. Both FFF-VMAT techniques had higher mean heart dose compared to Std-VMAT. In addition, Bolus-ECT with IMXT was able to reduce mean dose to the contralateral breast compared to Std-VMAT and both FFF-VMAT techniques had comparable but slightly reduced dose compared to Std-VMAT. Conclusion: This work has shown that Bolus-ECT with IMXT produces clinically acceptable plans while reducing OAR doses. Both FFF-VMAT techniques are comparable to Std-VMAT with slight improvements. Even though all VMAT techniques produce more homogenous and conformal dose distributions, Bolus-ECT with IMXT is a viable option for treating post-mastectomy patients possibly leading to reduced risks of normal tissue complications.

60 APPLIED LIFE SCIENCES↗